您即将下载 1.0.20.0

与上一版本相比,主要更新如下:

New features:

  • Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.

 

版本号 发布日期 描述

1.0.20.0

20/07/2022

New features:

  • Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.

 

1.0.19.0

01/07/2022

New features:

  • Identification of controllers in Pairing page.
    • Added the ability to send the "Identify" command from the "Pair" page.
    • This command creates a blinking pattern of the power LED of the PSM3.1 card.
    • This allows users working in an environment with multiple controllers to easily confirm the controller they wish to pair the display with.
  • Support for CODESYS custom info pop-up and status text.
    • This allows CODESYS designers to provide better user experience by delivering messaging and status information of the CODESYS application.

Changes:

  • Synchroscope page label
    • Added a label to identify the breaker that is being synchronised.
    • This improves the recognition of the controller being synchronised.

1.0.18.0

23/04/2022

New features:

  • DU300 button management.
    • Added the ability to disable (and enable) the buttons of the DU300 by parameters.
    • The buttons are disabled in blocks related to their functionality.
    • This provides more possibilities to configure the controller to the application's requirements.

Corrections:

  • Fixed an issue with the differentiation of two synchroscopes with the same measurements, like an EDG.
  • Fixed an issue related to ANSI codes shown on the alarm popup.

1.0.17.0

25/01/2022

Changes:

  • Improved navigation and look of the Parameters page.

Corrections:

  • Solved an issue that would cause the DU 300 to crash when downgrading DU software.

1.0.16.0

11/10/2021

New features:

  • Support for Tags:
    • New menu for options to display the tags set in parameters.
    • Options for tag visualisation include: Alarm pop-up, alarm list, logs page and parameter page.

Changes:

  • Update to languages
  • Connection improvements

Corrections:

  • Solves an issue where the display could enter a manual loop after returning from synchroscope.

1.0.15.1

14/07/2021

Changes:

  • Font size and duration of error message increased in the virtual keyboard.
  • New counters icon for alignment with PICUS.

Corrections:

  • "Missing" counters removed from the display.
  • Units shown for the I/O terminals.
  • Counters are now limited based on the counter type.
  • Display restarts on I/O pages when fieldbus configuration is updated.
  • LED's no longer light up before the screens become active.
  • Passwords with special characters can now be used from the display.

1.0.15.0

24/02/2021

New features:

  • Synchroscope view.

Changes:

  • Local display configurations (for example, brightness and units) will now be kept when new application software is installed.

Corrections:

  • Bar graphs and gauges animations performance is increased.
  • Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.
  • Fixed an issue in Parameters where up/down buttons would not be shown.

1.0.14.0

28/01/2021

New features:

  • Custom alarm action suppression: It is now possible to enable alarm suppression for custom alarms from the display.
  • Fast data interface: Faster update rate of gauges, counters, status texts, and live data views.
  • Engine communication:
    • J1939 alarms and historical events.
    • Fieldbus, configuration, supervision and CANbus error handling.

Corrections:

  • Fixed translation of texts in the View designer.
  • Fixed translation of message box popup breadcrumb.
  • Fixed DU300 live data subheader text cutting lower case p, g, j, q, y letters.
  • Fixed DU300 showing negative ampere.
  • Fixed conversion between C and F not having effect on scaling (View design).

1.0.13.1

03/08/2020

Changes:

  •  Change default DU300 font to Noto sans

Corrections:

  • Not converting set point and hysteresis to F on custom alarms
  • Memory leak during PPU 300 long term test

1-0-13-0

09/06/2020

New features:

  • Support of IOM3.2 and IOM3.3.

1.0.11.1

15/04/2020

This software package consist of:

  • DU 300 SW version 1.0.11.1

Changes:

  • New Chinese font.

Corrections:

  • Fixed that DU 300 was not showing the correct prefix according to the scale.
  • Fixed that DU 300 was showing "undefined" entry in the value list for SYSTEM events.
  • Fixed a missing retranslation of IO card info in DU 300.
  • Fixed a memory leak in the display.
  • Fixed a missing translation of texts in units and in the user permission screen.

1.0.11.0

17/12/2019

This software package consist of:

  • DU 300 SW version 1.0.10.1

New features:

  • Extended alarm information.
  • Support of ACM3.2 V.1.0.0.0.
  • Support of Trip breaker outputs.
  • Support of /IO extension unit.

Changes:

  • Version page layout.
  • Backup and restore information.

Corrections:

  • Text bug in live views.
  • DU shows random info message.
  • Display showing wrong version number.
  • ApplState not updating text.
  • Backup from the display shows undefined text in information window.
  • Missing text for View design.
  • Restore info page: Not all cards is shown.
  • Display does not update alarm and event texts, when the custom text is changed on external breaker.
  • Backup status should handle error status.
  • Possible to enter alarm sub-menus with an empty alarms list.
  • Parameter settings are shown on the display, when setting up digital outputs.

1.0.10.1

23/10/2019

This software package consist of:

  • DU 300 SW version 1.0.10.1

Changes:

  • Support for BSP 3.0.0.1 

1.0.10.0

04/03/2019

This software package consist of:

  • DU 300 SW version 1.0.10.0

New features:

  • Support for multiple menu levels.
  • Display shows a pop-up window for the user before going into service mode.
  • Informs the user about development of the software.

Changes:

  • Support for PlantSupervision ver 1.0.5.0.

Corrections:

  • IOM3.4: DO's are not shown on display and in PICUS.
  • Display is not loading min. and max. from parameters when they are changed.
  • Power derate temperature is not shown on DU until power cycle.
  • When changing type, DU sometimes freezes until it restarts.
  • DU300 reboot in view designer.
  • Not able to close alarm pop-up.
  • Alarm "trigger value" is not updated if the alarm is already in the alarm list.
  • DU300 does not check versions for individual REST resources.
  • View designer cannot add counters to counters template.

在此页面,您可以下载产品的更新软件,并使用各种实用工具和附加组件设置、检测故障和配置产品。

请注意,用户无法更新我们的所有产品。同时也不是所有产品都配有实用工具。因此,本页的软件列表不能视为DEIF产品的概述。

DEIF将登记您注册的下载邮箱地址,以便在未来需要时发送有关的更新信息。

DEIF不对产品更新失败或使用实用工具造成的任何后果负责。DEIF A/S也不对软件升级导致的产品行为变化的后果负责。用户始终有责任在调试前确保正确的设置和配置。请在更新产品之前查阅软件的更新日志。

www.deif.cn软件下载许可协议

下载的软件仍是DEIF的财产。本软件不得用于商业目的分发, 不得全部或部分更改或重复使用,也不得出售给任何第三方。

最新版本,功能齐全

我们始终建议您安装最新版本的软件,以充分利用您的DEIF产品。

所有更新的软件都可以从www.deif.cn->支持->下载->软件栏目下下载。

如果您在查找产品的相关软件时有任何疑问或问题,请随时致电丹控电气(上海)有限公司,电话: +86 21 68796200,或者发送电子邮件至support@deif.cn, 我们随时为您服务。