Multi-line 2 ASC Application Software series 4.x 4.24.0
您即将下载 Multi-line 2 ASC Application Software series 4.x 4.24.0
您已选择下载我们的软件。
几秒钟内,您将收到一封包含下载链接的电子邮件。
如果使用软件有问题,请联系support@deif.cn.
诚挚的祝福,
DEIF A/S
本软件受DEIF A/S版权保护。请点击上述链接可查阅DEIF A/S版权和许可协议(EULA)。
本软件适用于以下DEIF产品
- ASC-4 储能控制器 - 自动可持续能源控制器
- ASC-4 太阳能控制器 - 自动可持续能源控制器
- ASC-4 储能单机控制器 - 全自动可持续储能控制器
- ASC-4 太阳能单机控制器 - 自动可持续能源控制器
您即将下载 4.24.0
与上一版本相比,主要更新如下:
PM compatibility version 1.28.0
New features:
- Support for Matter Energy PV protocol added.
- PMS Mode update feature added to ASC-4 Solar and Battery.
- A battery will now automatically charge to keep connected gensets at the min. DG load set point in island operation as long DG charging is enabled and SOC is below SOC maximum.
- Batteries can now automatically charge to assist the plant in reaching required mains set points if enabled by parameter 8025 and mains charging is also enabled.
- Support for Matter Energy PCS protocol added.
- Support for INVT XG Series PV protocol added.
- Inverter and busbar V/f measurements from inverter communication supported on all protocols on ASC-4 Solar and ASC-4 Battery.
- Support for SolarEdge PPC PV protocol added.
- New display view line for displaying ESS Power mode added.
Changes:
- Updated Allspark BMS protocol to use the read DC output voltage for calculating maximum charge capacity.
- Updated Schneider CL 30/33/50/60 PV protocol to only read 6 DC string current values to be compatible with the newest Schneider firmware.
- Updated Huawei V.3 PV Protocol to send a start/stop command to the inverter based on the ASC status.
Corrections:
- Corrected issue where multiple batteries operating in island with PVs could cause the PVs to overproduce power compared to what the batteries was asked to charge.
- Corrected issue where parameter 2741 for delaying regulation after start signal did not work for charging set points.
版本号 | 发布日期 | 描述 |
---|---|---|
4.24.0 |
24/11/2022 |
PM compatibility version 1.28.0 New features:
Changes:
Corrections:
|
版本号 | 发布日期 | 描述 |
---|---|---|
4.29.0 |
10/01/2025 |
PM compatibility version 1.35.1 New features
Changes
Corrections
|
4.28.0 |
22/05/2024 |
PM compatibility version 1.33.0 New features 1- Added support for the Acrel ADL power meter protocol. Changes 1- Updated the sequence of grid mode switching in the Sinexcel PWS1 ESS protocol. It will now always use the VSG modes as intermediate modes, in between the required grid modes, to prevent the PCS from stopping. Corrections: 1- Corrected issue where the Megarevo MPS ESS protocol would reinitialize the start sequence of the PCS in a loop. |
4.27.2 |
01/03/2024 |
PM compatibility version 1.33.0 Corrections:
|
4.27.0 |
19/12/2023 |
PM compatibility version 1.33.0 New features:• Added support for using CAT EMCP 4 controllers directly as power meter.
Changes:• Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.
Corrections.• Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue. |
4.26.1 |
26/10/2023 |
PM compatibility version 1.30.0
Corrections
|
4.26.0 |
10/07/2023 |
PM compatibility version 1.30.0 New features
Changes
Corrections
|
4.25.0 |
09/02/2023 |
PM compatibility version 1.29.0 New features:
Changes:
Corrections:
|
4.24.0 |
24/11/2022 |
PM compatibility version 1.28.0 New features:
Changes:
Corrections:
|
4.23.1 |
15/09/2022 |
PM compatibility version 1.25.0 Corrections:
|
4.23.0 |
31/08/2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.22.0 |
03/05/2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.21.0 |
18/02/2022 |
PM compatibility version 1.25.0 New features: Changes: |
4.20.0 |
09/12/2021 |
PM compatibility version 1.24.2 New features:1- Sungrow LC100 BCU protocol added. Changes:1- Renamed "Ginlong Solis" PV protocol to "Solis (Ginlong)". |
4.19.0 |
22/11/2021 |
PM compatibility version 1.24.2 New features:
Changes:
Corrections:
|
4.18.0 |
20/09/2021 |
PM compatibility version 1.24.1 New features:
Changes:
Corrections:
|
4.17.1 |
16/07/2021 |
PM compatibility version 1.24.1. Corrections:1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter. |
4.17.0 |
28/06/2021 |
PM compatibility version 1.24.1. New features:
Changes:
Corrections:
|
4.16.0 |
08/04/2021 |
PM compatibility version 1.23.0. New features:
Changes:
Corrections:
|
4.15.1 |
25/02/2021 |
PM compatibility version 1.22.0. Corrections:
|
4.15.0 |
30/11/2020 |
PM compatibility version 1.22.0. New features:
|
4-14-2 |
29/10/2020 |
PM compatibility version 1.20.0 Corrections:
|
4.12.0 |
19/03/2020 |
PM compatibility version 1.16.0. New features:
|
4.11.3 |
28/01/2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.2 |
24/01/2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.1 |
31/10/2019 |
PM compatibility version 1.16.0. Corrections:
|
4.11.0 |
11/12/2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.10.1 |
16/04/2018 |
Corrections:
|
4.10.0 |
20/03/2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.05.2 |
12/01/2018 |
Corrections:
|
4.05.1 |
02/01/2018 |
PM compatibility version 1.15.0
|
4.05.0 |
30/11/2017 |
PM compatibility version 1.15.0 New features:
Corrections:
Changes:
|
4.04.0 |
05/10/2017 |
PM compatibility version 1.15.0 New features:1- Support of HiQ inverter. |
4.03.1 |
09/05/2017 |
PM compatibility version 1.15.0 Corrections:
|
4.03.0 |
03/04/2017 |
Version 4.03.0 New features:
Changes:
Corrections:
|
4.02.0 |
21/12/2016 |
PM compatibility version 1.15.0 New features:
Changes:
Corrections:
|