Multi-line 2 AGC-4 Mk II Application Software
您即将下载 Multi-line 2 AGC-4 Mk II Application Software
您已选择下载我们的软件。
几秒钟内,您将收到一封包含下载链接的电子邮件。
如果使用软件有问题,请联系support@deif.cn.
诚挚的祝福,
DEIF A/S
本软件受DEIF A/S版权保护。请点击上述链接可查阅DEIF A/S版权和许可协议(EULA)。
本软件适用于以下DEIF产品
您即将下载 6.21.0
与上一版本相比,主要更新如下:
- USW version required: 3.62.0
- TDU version required: 1.4.5.0
PM compatibility: 1.41.0
New features
- EIC: Added many new SPN texts for DM1 log.
- EIC: Added fuel rate alarm based on active power.
- GENSET: Added counter for number of successful generator starts.
- EIC: Added Guascor GCS-e ECU protocol.
Changes
- M-Logic: Renamed 'Virtual toggle' to 'Virtual event' and 'Virtual switch' to 'Virtual toggle'.
- Virtual events work the same on Modbus and M-Logic. The output of the virtual event will follow the input of the virtual event.
- Virtual toggles work the same on Modbus and M-Logic. If the input of the virtual toggle goes high, the output changes state once.
- Added parameter 7075, "Mains Fail Assumption", which enables the Mains controller to assume that the mains have just recovered at start-up, allowing it to run the OK timers.
- EIC: Keyswitch (#15050) is available for J1939 protocols.
- Updated EODev H2G fuel cell transmission rate has been to 20 ms for I, P and Q measurements.
- EIC: Added TSC1 to YC-ECU-A.
- EIC: Changed crankcase pressure (SPN 101) to kPa unit in delta alarms.
Corrections
- GENSET: The frequency/voltage regulation mode is no longer dependent on the frequency detection level when running with the GB closed.
- GENSET: Gen stop + GB Off M-Logic command can now stop the genset during the start sequence.
- If breaker is not used, the associated position feedback are cleared so they can be used for something else. Also added protection against overwriting position feedback assignment when the associated breaker is setup.
- M-Logic virtual toggles (previously named switches) can now be read over Modbus.
- GENSET: If idle run was active, RMI oil pressure alarms would be active before it was detected that the engine was running. This has been changed so that the engine must be running before the alarms can be active.
- Droop curve 2 configured with power factor output now works properly again.
- GENSET: Regulation mode will correctly be set to fixed power P/Q control when PMS isochronous master is active in power management.
版本号 | 发布日期 | 描述 |
---|---|---|
6.21.0 |
19/05/2025 |
PM compatibility: 1.41.0 New features
Changes
Corrections
|
6.20.0 |
10/03/2025 |
PM compatibility: 1.40.0 New features
Changes
Corrections
|
6.15.1 |
07/02/2025 |
PM compatibility: 1.35.1 Corrections
|
6.15.0 |
03/12/2024 |
USW version required: 3.61.0 PM compatibility: 1.35.1 New features
Changes
Corrections
|
6.14.0 |
27/09/2024 |
IMPORTANT: This software requires USW-3 version 3.60.2 with PDB revision 10901 or higher. PM compatibility: 1.35.1 New features:
Changes:
Corrections:
|
6.13.1 |
15/07/2024 |
PM compatibility: 1.34.0 Corrections1- Corrected unit restarting if Profibus option is selected. |
6.13.0 |
18/06/2024 |
PM compatibility: 1.34.0 New features 1- Fuel optimisation further optimised in more applications, including PV and battery. Changes 1- Spinning reserve stop hysteresis calculation is now based on the nominal power on busbar after next DG to stop.
Corrections 1- Auto calculation multistarts with fuel optimisation, now works before the TB is closed. |
6.12.1 |
26/02/2024 |
PM compatibility: 1.34.0 Corrections
|
6.12.0 |
30/10/2023 |
PM compatibility: 1.32.0 New features• EIC: Added support of Weichai E6. Changes• EIC: Added GTACP (0xFE05, SPN2452/2460) to Caterpillar generic and Perkins generic. Corrections• PMS priority update in 32DG application now working correctly. |
6.11.3 |
21/09/2023 |
PM compatibility: 1.30.1 Corrections
|
6.11.2 |
14/09/2023 |
PM compatibility: 1.30.1 Corrections
|
6.11.1 |
21/07/2023 |
PM compatibility: 1.30.0 Corrections
|
6.11.0 |
11/07/2023 |
PM compatibility: 1.30.0 New features
Changes
Corrections
|
6.10.2 |
25/05/2023 |
PM compatibility: 1.29.0 Corrections
|
6.10.1 |
23/03/2023 |
PM compatibility: 1.29.0 Corrections
|
6.10.0 |
06/03/2023 |
PM compatibility: 1.29.0 New features
Changes
Corrections
|
6.09.1 |
20/01/2023 |
PM compatibility: 1.29.0 Corrections
|
6.09.0 |
23/12/2022 |
PM compatibility: 1.28.0 New features:
Changes:
Corrections:
|
6.08.1 |
13/12/2022 |
PM compatibility: 1.28.0 Corrections:
|
6.08.0 |
17/11/2022 |
PM compatibility: 1.28.0 New features:
Changes:
Corrections:
|
6.07.0 |
11/07/2022 |
PM compatibility: 1.25.0 New features:
Corrections:
|
6.06.0 |
18/02/2022 |
PMS compatibility: 1.25.0 New features: Finetuning: |
6.05.0 |
01/02/2022 |
PM compatibility: 1.24.2 New features:
Changes:
Corrections:
|
6.04.3 |
16/11/2021 |
PM compatibility: 1.24.1 Corrections:
|
6.04.2 |
10/11/2021 |
PM compatibility: 1.24.1 Corrections:
|
6.04.1 |
22/10/2021 |
Not UL approved version PM compatibility: 1.24.1 Corrections:
|
6.04.0 |
07/10/2021 |
Not UL approved version PM compatibility: 1.24.1 New features:
Changes:
Corrections:
|
6.03.1 |
13/09/2021 |
Not UL approved version PM compatibility: 1.24.1
|
6.03.0 |
15/07/2021 |
Not UL approved version PM compatibility: 1.24.1 New features:
Changes:
Corrections:
|
6.02.1 |
06/05/2021 |
UL approved version PM compatibility: 1.23.0 Corrections:
|
6.02.0 |
06/04/2021 |
Not UL approved version PM compatibility: 1.23.0 New features:
Changes:
Corrections:
|
6.01.2 |
15/03/2021 |
Not UL approved version PM compatibility: 1.22.0 Corrections:
|
6.01.1 |
12/02/2021 |
Not UL approved version PM compatibility: 1.22.0 Corrections:
|
6.01.0 |
11/01/2021 |
UL approved version PM compatibility: 1.22.0 New features:
|
6-00-0 |
07/01/2021 |
Not UL approved version PM compatibility: 1.22.0 |
在此页面,您可以下载产品的更新软件,并使用各种实用工具和附加组件设置、检测故障和配置产品。
请注意,用户无法更新我们的所有产品。同时也不是所有产品都配有实用工具。因此,本页的软件列表不能视为DEIF产品的概述。
DEIF将登记您注册的下载邮箱地址,以便在未来需要时发送有关的更新信息。
DEIF不对产品更新失败或使用实用工具造成的任何后果负责。DEIF A/S也不对软件升级导致的产品行为变化的后果负责。用户始终有责任在调试前确保正确的设置和配置。请在更新产品之前查阅软件的更新日志。
www.deif.cn软件下载许可协议
下载的软件仍是DEIF的财产。本软件不得用于商业目的分发, 不得全部或部分更改或重复使用,也不得出售给任何第三方。
最新版本,功能齐全
我们始终建议您安装最新版本的软件,以充分利用您的DEIF产品。
所有更新的软件都可以从www.deif.cn->支持->下载->软件栏目下下载。
如果您在查找产品的相关软件时有任何疑问或问题,请随时致电丹控电气(上海)有限公司,电话: +86 21 68796200,或者发送电子邮件至support@deif.cn, 我们随时为您服务。