Multi-line 300 GPC 300 ver. 1.x.x.
您即将下载 Multi-line 300 GPC 300 ver. 1.x.x.
您已选择下载我们的软件。
几秒钟内,您将收到一封包含下载链接的电子邮件。
如果使用软件有问题,请联系support@deif.cn.
诚挚的祝福,
DEIF A/S
本软件受DEIF A/S版权保护。请点击上述链接可查阅DEIF A/S版权和许可协议(EULA)。
本软件适用于以下DEIF产品
您即将下载 1.0.23.0
与上一版本相比,主要更新如下:
This software package consist of:
- Multi-line 300, GPC 300
- Bundled with DU 300 SW version 1.0.20.0
Minimum required version of PICUS: 1.0.20.0
GPC 300
New feature:
- New variant that has a mains with mains breaker and tie breaker.
- Added emulation for single gensets.
- Added the possibility to read dynamic section status in CODESYS.
- Added PMS power measurement data.
Changes:
- Changed the maximum value for breaker open failure delay to 60 seconds.
- Changed the maximum value for breaker close failure delay to 60 seconds.
- Added PMS power measurement data.
- Selection of "Phase-Phase" / "Phase-Neutral" on selected voltage protections are always shown.
Corrections:
- Emulation now works with fixed power, while mains is exporting (negative kW values on mains).
- Breaker operation counter now increments correctly in emulation.
- Fixed issue with no tags shown in HMI for AC setup parameter.
- Improved backup percentage count in PICUS.
- Missing texts have been added.
- It is now possible to access the DM2 log from PICUS.
- Fixed missing IOM3.4 support.
- Analogue AVR now works in emulation.
- Fixed an issue with external breaker feature in emulation.
- Fixed an issue with using the stop command from switchboard in emulation. This would not stop the engine when running in parallel.
- Mains variants have regulator control available in emulation.
- Close failure can now be emulated.
- The response time for the trip breaker output can exceed 100ms if the configuration has been done in a particular order and the controller has not been power cycled.
- Fixed issue where there could be Hz on the generator measurements in emulation when the engine was stopped.
- Fixed issue with MPU wire break. It is now working.
- Fixed issue where the states in emulation were preserved when emulation was not enabled.
DU 300
New features:
- Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.
版本号 | 发布日期 | 描述 |
---|---|---|
1.0.23.0 |
08/03/2023 |
This software package consist of:
Minimum required version of PICUS: 1.0.20.0 GPC 300New feature:
Changes:
Corrections:
DU 300New features:
|
1.0.21.0 |
07/10/2022 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 GPC 300New feature:
Corrections:
DU 300New features:
|
1.0.20.0 |
09/09/2022 |
This software package consist of:
Minimum required version of PICUS: 1.0.19.0 GPC 300First release DU 300New features:
|
在此页面,您可以下载产品的更新软件,并使用各种实用工具和附加组件设置、检测故障和配置产品。
请注意,用户无法更新我们的所有产品。同时也不是所有产品都配有实用工具。因此,本页的软件列表不能视为DEIF产品的概述。
DEIF将登记您注册的下载邮箱地址,以便在未来需要时发送有关的更新信息。
DEIF不对产品更新失败或使用实用工具造成的任何后果负责。DEIF A/S也不对软件升级导致的产品行为变化的后果负责。用户始终有责任在调试前确保正确的设置和配置。请在更新产品之前查阅软件的更新日志。
www.deif.cn软件下载许可协议
下载的软件仍是DEIF的财产。本软件不得用于商业目的分发, 不得全部或部分更改或重复使用,也不得出售给任何第三方。
最新版本,功能齐全
我们始终建议您安装最新版本的软件,以充分利用您的DEIF产品。
所有更新的软件都可以从www.deif.cn->支持->下载->软件栏目下下载。
如果您在查找产品的相关软件时有任何疑问或问题,请随时致电丹控电气(上海)有限公司,电话: +86 21 68796200,或者发送电子邮件至support@deif.cn, 我们随时为您服务。