iE 250 Application Software

您即将下载 iE 250 Application Software

您已选择下载我们的软件。

几秒钟内,您将收到一封包含下载链接的电子邮件。

如果使用软件有问题,请联系support@deif.cn.

诚挚的祝福,

DEIF A/S

本软件受DEIF A/S版权保护。请点击上述链接可查阅DEIF A/S版权和许可协议(EULA)。

本软件适用于以下DEIF产品

您即将下载 2.0.7.2

与上一版本相比,主要更新如下:

Minimum required version of PICUS: 1.0.23.0

Corrections

  • EIC start/stop now works on all protocols. Small fixes made to CAT7.1.
  • Fixed issue where display preferences were not stored during power cycle.
  • Fixed issue where display did not exit dimmed state.
  • Fixed issue where Web.config was not bundled correctly in the RAUC bundle.
  • Implemented Yanmar Stage V regeneration acknowledge lamp.
版本号 发布日期 描述

2.0.7.2

02/12/2024

Minimum required version of PICUS: 1.0.23.0

Corrections

  • EIC start/stop now works on all protocols. Small fixes made to CAT7.1.
  • Fixed issue where display preferences were not stored during power cycle.
  • Fixed issue where display did not exit dimmed state.
  • Fixed issue where Web.config was not bundled correctly in the RAUC bundle.
  • Implemented Yanmar Stage V regeneration acknowledge lamp.

2.0.7.1

07/11/2024

Minimum required version of PICUS: 1.0.22.0

New features

  • EIC: Added a parameter to configure TSC1 destination address.
  • Added EIC protocol Yanmar Stage V.
  • Added EIC protocol Jichai JC15T JG.

Corrections

  • TSC1 corrected for Caterpillar, Perkins, Iveco Vector8 and John Deere. VP70 source address corrected for Volvo Penta EMS2 and EMS2.3.
  • EIC: Ash load percentage is available on Modbus and the display.
  • Fixed issue where screen was white on startup.
  • EIC: Corrected frequency selection for Volvo Penta EMS 2.4.

2.0.4.1

11/07/2024

Minimum required version of PICUS: 1.0.22.0

New features

  • An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Security Log Management requirements.
  • Updated Volvo EMS2.4 to support ACM module.
  • EIC: Added support for CAT C7.1.
  • EIC: Added support for Kohler KDI3404.

Corrections

  • Fixed default value for the regulator status text.
  • Added support for adjusting the brightness level on the controller.
  • Fixed visibility of ECU and CAN parameters.
  • Fixed issue where Custom Logic was missing.
  • Fixed issue where the licence error alarm could occur after a restore from a backup.
  • Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.
  • Fixed issue where disclaimer was incorrectly shown.

2.0.1.0

03/04/2024

This software package consist of:

  • One single file which contains the entire application SW for the controller

 

To be used with at the least PICUS version 1.0.21.0

 

New features:

• Added a navigation item linked to CODESYS Webvisu allowing a seamless transfer to the WebVisualization page.

 

Corrections:

• Corrected issue where the "Communication settings changed" alarm was incorrectly triggered.
• Corrected the menu structures in the display menu.
• Corrected inconsistent configuration of network and port settings in the browser configuration tool.

2.0.0.1

23/02/2024

This software package consist of:

  • One single file which contains the entire application SW for the controller

 

To be used with at the least PICUS version 1.0.21.0

 

Changes:

Changed SSH service to OFF by default.

 

Corrections:

-Corrected an issue in emulation causing the controller to restart.
-Corrected the naming of the action choices for the "CAN fail mode alarm".
-Corrected reactive energy unit from kvar to kvarh.
-Corrected an issue causing the DEF level to not be shown by default on the Exhaust after-treatment dashboard.
-Corrected an issue causing the auto-jump to the Exhaust after-treatment dashboard not to work.
-Corrected an issue on the Exhaust after-treatment dashboard where the engine lamps would not appear when transitioning directly from N/A to ON.

 

2.0.0.0

06/02/2024

This software package consist of:

  • One single file which contains the entire application SW for the controller

 

To be used with at the least PICUS version 1.0.21.0

 

New features:

• Initial release

 

 

在此页面,您可以下载产品的更新软件,并使用各种实用工具和附加组件设置、检测故障和配置产品。

请注意,用户无法更新我们的所有产品。同时也不是所有产品都配有实用工具。因此,本页的软件列表不能视为DEIF产品的概述。

DEIF将登记您注册的下载邮箱地址,以便在未来需要时发送有关的更新信息。

DEIF不对产品更新失败或使用实用工具造成的任何后果负责。DEIF A/S也不对软件升级导致的产品行为变化的后果负责。用户始终有责任在调试前确保正确的设置和配置。请在更新产品之前查阅软件的更新日志。

www.deif.cn软件下载许可协议

下载的软件仍是DEIF的财产。本软件不得用于商业目的分发, 不得全部或部分更改或重复使用,也不得出售给任何第三方。

最新版本,功能齐全

我们始终建议您安装最新版本的软件,以充分利用您的DEIF产品。

所有更新的软件都可以从www.deif.cn->支持->下载->软件栏目下下载。

如果您在查找产品的相关软件时有任何疑问或问题,请随时致电丹控电气(上海)有限公司,电话: +86 21 68796200,或者发送电子邮件至support@deif.cn, 我们随时为您服务。