Multi-line 2 AGC Application Software series 2.x. 2.40.8

您即将下载 Multi-line 2 AGC Application Software series 2.x. 2.40.8

您已选择下载我们的软件。

几秒钟内,您将收到一封包含下载链接的电子邮件。

如果使用软件有问题,请联系support@deif.cn.

诚挚的祝福,

DEIF A/S

本软件受DEIF A/S版权保护。请点击上述链接可查阅DEIF A/S版权和许可协议(EULA)。

本软件适用于以下DEIF产品

您即将下载 2.40.8

与上一版本相比,主要更新如下:

Corrections:

  • Update of self-check functionality
  • Vector jump calculation improved
  • Zero sequence alarms improved
版本号 发布日期 描述

2.40.8

16/03/2015

Corrections:

  • Update of self-check functionality
  • Vector jump calculation improved
  • Zero sequence alarms improved
版本号 发布日期 描述

2.40.9

01/07/2015

Corrections:

  • Update of self-check functionality

2.40.8

16/03/2015

Corrections:

  • Update of self-check functionality
  • Vector jump calculation improved
  • Zero sequence alarms improved

2.40.7

11/03/2011

  • Improved handling of Running hour counter.

2.40.6

10/03/2009

  • Support of reverse vdo input 104
  • Modified power indication in display

2.40.5

05/11/2008

ModeShift handling updated

2.40.4

14/05/2007

Changes:

  • Updates made in Engine communication.
  • Updates made in power ramp functionality.

2.40.3

16/03/2007

Updates made in Island mode.

2.40.2

21/12/2006

Updates made in TB handling.

2.40.1

29/11/2006

Updates made in Variable Multi Start functionality.

2.40.0

12/10/2006

Changes:

  • EF5 option implemented.

2.34.3

02/10/2006

Changes:

  • C2 and A4 functionality updated.

2.34.2

06/06/2006

Changes:

  • Mode shift handling in LTO updated.
  • Simple test in AMF updated.
  • Handling of priorities improved.

2.34.1

08/05/2006

Changes:

  • Improvements made for handling MB/TB synchronization.
  • Improvement made in fuel optimization priority routine.
  • Breaker spring load timer functionality added.

2.33.3

27/03/2006

Changes:

  • Enable/Disable of "Short time parallel" accessable via MLogic.
  • Improvement made in single appl. AMF sequence when using "Start engine".
  • Improvement made in G5 appl. for handling different nominal voltage level between DG's and Mains unit.

2.32.2

08/03/2006

Changes:

  • 4-20mA analogue inputs on M1, M2 and M15 now supported in a mains unit.

2.33.1

02/02/2006

Changes:

  • Updates made in "Close before excitation" functionality.
  • MPE mode can now also be set up to import a fixed power.
  • MLogic updated to apply to rules for boolean algebra.
  • Updates made in single DG ramping functionality.
  • Improvements made for handling switching between a parallel operation and ISLAND mode.

2.32.0

29/11/2005

Changes:

  • Ramp up/down improved in G5 to obtain ramping after backsync of MB.
  • SoftSync functyionality opened up.
  • Updates made regarding LTO together with SoftSync.
  • 2nd set of nominal settings implemetet.
  • Manual control of gov/AVR increasing/decreasing added in MLogic.
  • Possibility if using a start enable input added.

2.30.1

06/10/2005

Changes:

  • load group handling added.
  • Relay configuration updated.
  • Transistor outputs for kWh and kVArh counter made configurable.
  • Auto acknowledge added.
  • Custom alarm inhibit added.
  • Seperate synchronisation functionality implemented.
  • Ramp up/down implemented in G5. Meaning whenever running parallel to mains and the power set point is altered
    Tge DG(s) will ramp to new set point.

2.30.0

05/10/2005

Changes:

  • Available power1&2 Menues added for adding load gruppes.
  • Relays can now be selected to either ALARM, LIMIT or HORN.
    Hereby the normal horn relay (relay11) can no be used as a
    LIMIT or HORN relay as well.
  • The transistors for kWh and kVArh counter can no be selected as continues.
    This means they can be selected as having normal relay functionality (relay12 and 13).
  • Auto acknowledge added. Via MLogic it is possible to set an alarm to autoacknowledge.
  • Custom alarm inhibit added. Via MLogic it is possible to set an alarm to be inhibited when
    the custom alarm input (configurable) is active.
  • Seperate synchronisation functionality implemented.

10.30.1

05/10/2005

Changes:

  • Ramp up/down implemented in G5. Meaning whenever running parallel to mains and the power set point is altered Tge DG(s) will ramp to new set point.

2.11.5

13/06/2005

Changes:

  • Use of Digital running feedback in regard to start sequence adjusted
  • Mode switched using remote control (M-Logic or configurable or modbus) adjusted

2.11.4

30/05/2005

Name of downloadable zip-file corrected - software is unchanged (the name of the zip-file is corrected to 2114 - before it was wrongly named 2113)

2.11.4

27/05/2005

Changes:

  • "Trip + Stop" alarm in G5 applications adjusted
  • Limit relay handling adjusted
  • Minor changes in menus (spelling)

2.11.3

25/05/2005

Changes:

  • Changes to avoid frequency drop during deload in island mode

2.11.2

29/03/2005

Changes:

  • Running detection functionality improved
  • Adjustment when using German display
  • Improvement of short time parallel performance
  • Mains failure detection when using phase/neutral measurements adjusted
  • Several minor adjustments of menus

2.11.1

04/03/2005

Changes:

  • RPM measurements optimised
  • Weekday manipulation is implemented
  • Reset of PWM output changed
  • The 'Year' indication in the log is corrected

2.11.0

21/01/2005

Changes:

  • Priority routine ”Fuel optimisation” updated
  • CAN alarm handling changed
  • Priority routine ”Running hour” updated
  • View lines updated
  • Delod routine updated in SEMI AUTO mode
  • Regulation reset updated
  • Start next DG in case of failure updated

2.10.2

14/12/2004

Changes:

  • AGC option G5: Start sequence regarding priority change adjusted

2.10.1

28/11/2004

New features:

  • New language structure similar to the BGC.
  • Phase - Neutral voltage trip similar to the PPU, GPU,GPC
  • Derate of Pnom (Described in Designers Ref. Handb.)
  • Idle run (Described in Designers Ref. Handb.)
  • Master Clock (Described in Designers Ref. Handb.)
  • Battery test (Described in Designers Ref. Handb.)
  • Wire break detection on analogue inputs (4- 20 mA, VDO, PT100)
  • External sync. start / close breaker
  • Support of AGC_GER display similar to BGC 0108 display.
  • New priority routine for option G5 (Fuel optimisation)
  • Support of ATS (Automatic Transfer Switch) applications in option G5
  • TB synchronises in LTO and AMF mode in option G5
  • Modbus updated to support new GDU features
  • M-Logic updated to support AOP setup

2.00.4

25/08/2004

Changes:

  • Menu handling in regard to Option C1 adjusted
  • The power calculation regarding loadsharing in PMS is optimised
  • Menu handling in regard to Governor control adjusted
  • Calculations used for scaling analogue input is optimised
  • Configurable texts are adjusted in length
  • Scaling of power-factor measurement in USW protocol changed
  • Factory settings for emergency modified.

2.00.3

27/07/2004

Changes:

  • Mains LED status improved
  • Offset possibility for number of GB and MB operations are added
  • Number of events in the Eventlog is increased
  • Fuel relay logic is improved
  • M-logic is improved regarding running detection
  • Modeshift functionality improved
  • Option M12 functionality improved
  • Option C2 functionality improved
  • GB sync function improved in ISLAND mode Single DG
  • Option EF4 menu handling improved

2.00.1

05/05/2004

Changes:

  • Some menus are adjusted
  • Frequency control for stand alone generator improved
  • Governor control when operating the breaker is improved
  • Improvement of low voltage BB-measurements

2.00.0

14/04/2004

New features:

  • PMS-functionality added
  • BLOCK-mode implemented
  • Support of GSM communication

Changes:

  • New menu-structure implemented
  • Mod-bus and Profi-bus protocols changed
  • Changed numbering of all inputs

END-USER LICENSE AGREEMENT (“EULA”) FOR DOWNLOADABLE SOFTWARE. (“the SOFTWARE PRODUCT”).

IMPORTANT: PLEASE READ THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT CAREFULLY BEFORE CONTINUING WITH THIS PROGRAM INSTALL:

 

DEIF A/S End-User License Agreement ("EULA") is a legal agreement between you (either an individual or a single entity) and DEIF A/S for the DEIF A/S software product(s) identified above which may include associated software components, media, printed materials, and "online" or electronic documentation. By installing, copying, or otherwise using the our product, you agree to be bound by the terms of this EULA. This license agreement represents the entire agreement concerning the program between you and DEIF A/S, (referred to as "licenser"), and it supersedes any prior proposal, representation, or understanding between the parties. If you do not agree to the terms of this EULA, do not install or use the SOFTWARE PRODUCT.

The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties, as well as other intellectual property laws and treaties. DEIF controllers are licensed, not sold.

1. GRANT OF LICENSE.

The SOFTWARE PRODUCT is licensed as follows:

(a) Installation and Use.
DEIF A/S grants you the right to install and use copies of the SOFTWARE PRODUCT on your computer running a validly licensed copy of the operating system for which the SOFTWARE PRODUCT was designed Windows 7, Windows 8, Windows 10.

(b) Backup Copies.
You may also make copies of the SOFTWARE PRODUCT as may be necessary for backup and archival purposes.

2. DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS.

(a) Maintenance of Copyright Notices.
You must not remove or alter any copyright notices on any and all copies of the SOFTWARE PRODUCT.

(b) Prohibition on Reverse Engineering, Decompilation, and Disassembly.
You may not reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT, except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation.

(c) Rental.
You may not rent, lease, or lend the SOFTWARE PRODUCT.

(d) Compliance with Applicable Laws.
You must comply with all applicable laws regarding use of the SOFTWARE PRODUCT.

3. TERMINATION

Without prejudice to any other rights, DEIF A/S may terminate this EULA if you fail to comply with the terms and conditions of this EULA. In such event, you must destroy all copies of the SOFTWARE PRODUCT in your possession.

4. COPYRIGHT

All title, including but not limited to copyrights, in and to the SOFTWARE PRODUCT and any copies thereof are owned by DEIF A/S or its suppliers. All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE PRODUCT is the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties. This EULA grants you no rights to use such content. All rights not expressly granted are reserved by DEIF A/S.

5. NO WARRANTIES

DEIF A/S expressly disclaims any warranty for the SOFTWARE PRODUCT. The SOFTWARE PRODUCT is provided 'As Is' without any express or implied warranty of any kind, including but not limited to any warranties of merchantability, noninfringement, or fitness of a particular purpose. DEIF A/S does not warrant or assume responsibility for the accuracy or completeness of any information, text, graphics, links or other items contained within the SOFTWARE PRODUCT. DEIF A/S makes no warranties respecting any harm that may be caused by the transmission of a computer virus, worm, time bomb, logic bomb, or other such computer program. DEIF A/S further expressly disclaims any warranty or representation to Authorized Users or to any third party.

6. LIMITATION OF LIABILITY

In no event shall DEIF A/S be liable for any damages (including, without limitation, lost profits, business interruption, or lost information) rising out of 'Authorized Users' use of or inability to use the SOFTWARE PRODUCT, even if DEIF A/S has been advised of the possibility of such damages. In no event will DEIF A/S be liable for loss of data or for indirect, special, incidental, consequential (including lost profit), or other damages based in contract, tort or otherwise. DEIF A/S shall have no liability with respect to the content of the SOFTWARE PRODUCT or any part thereof, including but not limited to errors or omissions contained therein, libel, infringements of rights of publicity, privacy, trademark rights, business interruption, personal injury, loss of privacy, moral rights or the disclosure of confidential information.