<?xml version="1.0" encoding="utf-8" ?>

<rss version="2.0"
     xmlns:content="http://purl.org/rss/1.0/modules/content/"
     xmlns:dcterms="http://purl.org/dc/terms/"
     xmlns:atom="http://www.w3.org/2005/Atom">

  <channel>
    <title>DEIF &#x8F6F;&#x4EF6;&#x4E0B;&#x8F7D;</title>
    <link>https://www.deif.cn/documentationfeed.xml</link>
    <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
    <description>DEIF&#x4EA7;&#x54C1;&#x5404;&#x7248;&#x672C;&#x8F6F;&#x4EF6;&#x4E0B;&#x8F7D;</description>
    <language>en</language>
    <lastBuildDate>Wed, 22 Apr 2026 10:16:51 GMT</lastBuildDate>


      <item>
        <title>AGI 300/400 SW Pack for BSP ver. 1.0 &#x2013; v4.0.0.140</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-300400-&#x8F6F;&#x4EF6;&#x5305;/4-0-0-140/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">571a2296-c120-45ee-b9ad-9e1eef413bd9</guid>
        <pubDate>2020-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 300/400 SW Pack for BSP ver. 1.0</category>
        <category domain="version">4.0.0.140</category>
          <category domain="product">AGI 400</category>
          <category domain="product">AGI 300</category>
        <content:encoded><![CDATA[
<p>The main changes implemented since the last version are as follows:</p>
<h3>New features:</h3>
<ul>
<li>MQTT gateway for standard cloud services (Amazon, Azure, others)</li>
<li>Unified project design </li>
<li>Unified design: Project Validator </li>
<li>Project View refactor </li>
<li>Regional settings as project properties </li>
<li>Live Tag for labels, message, alarm description </li>
<li>TargetZoomFactor with an option to work as Fit to screen size </li>
<li>Table group widget sorting </li>
<li>Added "Dynamic" path for all macros related to Dump or Restore </li>
<li>Alarm Export - Include multilanguage support for Custom Fields </li>
<li>Float Tag data into alarm description, visualization management  </li>
<li>Added support for reading panel serial number using SysTarget Library command </li>
<li>Support for audit table format in print reports</li>
<li>Support of graphs trends in print reports </li>
<li>Trends table support in print reports </li>
<li>XY Graph support in print reports </li>
<li>Support for new Active Alarms table format in print reports </li>
<li>Support for new History Alarms table format in print reports </li>
<li>Support for generic tables in print reports </li>
<li>Import of dbc file into the Tags (CAN Direct or J1939) </li>
<li>[BACN] BACnet server </li>
<li>[ETIP] Added Omron NX series to EtherNet/IP PLC models </li>
<li>Added ARCSIN, ARCCOS, ARCTAN to the default functions for Formula feature </li>
<li>Password Parameter includes the option to have lower and upper case </li>
<li>Option to make users inactive </li>
<li>Protection of Tags in R/W based on user management configuration </li>
<li>Increased number of active users from 50 to 200/500 </li>
<li>Increased sampling rate up to 0.1s for trends and datalogs </li>
<li>Provided an option to play video from USB Memory or SD Card - Case ID: 201404845 </li>
<li>End of AGI Creator support Windows XP</li>
</ul>
<h3>Improvements:</h3>
<ul>
<li>Keyboard buttons long pressure execute action, configured into onRelease event </li>
<li>Corrected wrong dialogs position on show dialog action </li>
<li>Action "CloseDialog" executed in ScreenSaver onStart restart the ScreenSaver timer </li>
<li>Alarm/Event Archive saves a copy in .csv file when buffer is full </li>
<li>Corrected Alarm Editor Index of Array Tag from disappearing when project is converted </li>
<li>Corrected AGI Client not activating Tags when connecting from remote via VPN </li>
<li>Correcetd tag deletion leading to an inability to select any AGI Creator part when the properties pane is floating </li>
<li>Corrected AGI Runtime crashes when using BACnet application</li>
<li>Corrected AGI Runtime crashes when loading a project with many pages in pre-cache </li>
<li>Corrected sending multiple mails with empty text causing bad chars to be displayed in HMI </li>
<li>Corrected crash of the panel caused by dialogs </li>
<li>Corrected AGI Runtime crash with when broken context in the formula</li>
<li>Language to use inside the .csv file generated from the DumpEventArchive macro</li>
<li>Corrected security settings are not applied for OnDataUpdate programmed actions</li>
<li>Corrected accessing a remote folder using a password with uppercase is not working</li>
<li>Corrected consumption meter not scaling a value in graph  </li>
<li>Corrected wrong dump file name after enabling scheduler from widget</li>
<li>Corrected Dump Trend including quality information if not required when launched from Scheduler </li>
<li>Corrected license activation return error message if BIOS ID is empty</li>
<li>Corrected content of csv exported file being inconsistent with what displayed into Multilanguage editor for custom widgets labels</li>
<li>Corrected AGI Creator crashing when undoing the customized widget with a specific project</li>
<li>Corrected Tags Cross Reference showing system variables as invalid if project has been converted from previous versions</li>
<li>Corrected panel reporting "Flash memory does not have enough space to save project data..." when recipes are defined and erased in the project</li>
<li>Corrected BACnet alarms and scheduler not working correctly in AGI Creator Client </li>
<li>Corrected gestures in trend widget that were not working well in portrait mode</li>
<li>Corrected AGI Creator not detecting if a Tag/parameter is used more times in a formula </li>
<li>Corrected NOT Formula not working if applied to bit of Short tag </li>
<li>Corrected security not supported by inner objects of table widget </li>
<li>Corrected security settings not being applied for OnDataUpdate programmed actions </li>
<li>Corrected it not being possible to execute action after signature dialog is closed</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 300/400 SW Pack for BSP ver. 1.0 &#x2013; v4.0.1.502</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-300400-&#x8F6F;&#x4EF6;&#x5305;/4-0-1-502/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">eb19374b-6ac8-4749-808f-adb17d036f13</guid>
        <pubDate>2021-06-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 300/400 SW Pack for BSP ver. 1.0</category>
        <category domain="version">4.0.1.502</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
          <category domain="product">AGI 300</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>CODESYS R14 package</li>
</ul>
<h3>Improvements:</h3>
<ul>
<li>Corrected Tag scaling issues</li>
<li>Corrected project crashing when upgrading from previous version</li>
<li>Corrected errors in Custom field 1 when exporting Alarm lists </li>
<li>Corrected missing Webkit plugin</li>
<li>Corrected accept NTP request settings</li>
<li>Corrected white color (255,255,255) not working on shape line widget</li>
<li>Corrected the ability to delete multiple tags in Tag editor without crashing</li>
<li>Corrected the functionality to Write of IDs and IP in Beckhoff ADS protocol in Runtime</li>
<li>Corrected the ability to open page in an uploaded project before saving</li>
<li>Numerous minor corrections</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 300/400 SW Pack for BSP ver. 1.0 &#x2013; v2.8.0.380</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-300400-&#x8F6F;&#x4EF6;&#x5305;/2-8-0-380/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2c66c1eb-219b-47ee-8ebe-c1f3aa5744dd</guid>
        <pubDate>2019-01-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 300/400 SW Pack for BSP ver. 1.0</category>
        <category domain="version">2.8.0.380</category>
          <category domain="product">AGI 400</category>
          <category domain="product">AGI 300</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Extend gesture area widget with the possibility to execute one-shot actions on new events.</li>
<li>Background colour for alarm widgets.</li>
<li>Table Alarm widget optimization.</li>
<li>CODESYS fastboot.</li>
<li>Logging of the license status of all CODESYS modules.</li>
<li>Provide the "attach to tag" to buzzer properties inside project widget.</li>
<li>Fit to screen size.</li>
<li>Add Keyboard functionalities also in Dialog pages.</li>
<li>Add JavaScript debugger support for custom widget modules.</li>
<li>Add project.log (message) API to write into runtime console log.</li>
<li>Web: Possibility to change alarms font.</li>
<li>Web: Add SetTrendView (Xmin, Xmax, Ymin, Ymax).</li>
<li>Web: Password ageing/expire functionality.</li>
<li>Web: Possibility to define the range of values in ColorPalette.</li>
<li>Possibility to cleanup Unused Tags.</li>
<li>Add cross reference for all type of data sources (via System variable, Recipes, Alias).</li>
<li>Save HMI IP address as part of project files.</li>
<li>HMI Client for panels (Linux HMIs only).</li>
<li>Password ageing/expire functionality.</li>
<li>Add specific user permissions for Web access and Windows Client access.</li>
<li>Allow attach to tag for custom widget parameters.</li>
<li>Table widget support for Alarm history.</li>
<li>Convert pages from web to native and back.</li>
<li>Expose VNC server start/stop/state in system variables/services.</li>
<li>Tags find and replace.</li>
<li>Tags find and rename.</li>
<li>Extend trends to save a copy when full in csv format.</li>
<li>Table widget support for Trends - Case ID.</li>
<li>Video player support for Linux platforms.</li>
<li>HTTPs support for browser widget.</li>
</ul>
<h3>Improvements:</h3>
<ul>
<li>Alarm history widget does not show correct groups.</li>
<li>Wrong ack notify tag on alarm setting after delete alarms.bin file.</li>
<li>Unable to activate iPLC3  if panel is connected to the network with Ethernet interface different from eth0.</li>
<li>[iPLC3] HMI reboot when CODESYS project stays in stop for some time.</li>
<li>Decimal values are not written if Index tag is a float.</li>
<li>Manage Data Transfer between tags with different data types.</li>
<li>Tag read when set as destination tag of Data Transfer executed on trigger.</li>
<li>Retentive memory behavior differs between Ethernet download and use of update package.</li>
<li>Parameter does not maintain name if it starts with number.</li>
<li>Live Tags in alarm description is updated once when triggered and not again.</li>
<li>Panel CPU stuck at 100% when a dialog page is opened, causing very slow reaction of the system.</li>
<li>Some buttons defined in template page are not working in customer projects.</li>
<li>Touch events are not working on system windows opened from AGI Runtime PC running on Windows 10.</li>
<li>Customer projects show missing images and then reboots after VNC connection.</li>
<li>Panel Pc numeric keyboard on a dialog page writes numbers twice.</li>
<li>Fixed widget gallery behavior if using two monitors with specific settings.</li>
<li>Searching text in JavaScript, delete last text modify.</li>
<li>Support also UTF-8 in JavaScript instruction "fs.readFile".</li>
<li>Fixed behavior of generic Tag import/export.</li>
<li>Fixed Studio behavior in Real Time Trend, attach a Date Time combo widget to the Page Duration property.</li>
<li>Improve gestures on PDF viewer.</li>
<li>Missing columns in Alarms Report widget.</li>
<li>[OPCU] Tag import is not working with Matrikon OPC UA Gateway using security.</li>
<li>[J193] DataTransfer from retentive system variable to J1939 variable is not executed on startup.</li>
<li>[ETIP] Tag importer does not create string array element tag for boolean array. </li>
<li>[CDS3] Slowness of first access to CODESYS variables.</li>
<li>[OPCU] Tags browse becomes progressively slow when there is a big amount of tags to be imported.</li>
<li>[iPLC3] [CDS3] When Enabling or Disabling PLCM09 network, CODESYS v3 gets a communication error.</li>
<li>[BEAD] Communication problem if array tag is used instead of single array element.</li>
<li>ChangePassword User Management page error message not cleared after wrong inserted password.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware version 1.0.x &#x2013; v1.0.535</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-&#x8F6F;&#x4EF6;/1-0-535/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e3a3c2b0-9aac-47ea-91d9-2fc548833e74</guid>
        <pubDate>2020-09-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware version 1.0.x</category>
        <category domain="version">1.0.535</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Firewall support</li>
<li>NAT/Forward service support</li>
<li>Zero dimming enhancement AGI 410 </li>
<li>Enable NTP local time reference clock</li>
</ul>
<h3>Corrections/Improvements</h3>
<ul>
<li>Improved event behavior when touchscreen is disabled</li>
<li>Cursor may not appear at boot with some mouse devices</li>
<li>800Kbit CAN baudrate support</li>
<li>Improved Ethernet messages in case of high network traffic </li>
<li>Software bridge not working via API</li>
<li>Screen remains black after toggling external timeout variable</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware version 1.0.x &#x2013; v1.0.741</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-&#x8F6F;&#x4EF6;/1-0-741/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">862729aa-9a81-408c-89b5-098b53a794a4</guid>
        <pubDate>2021-12-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware version 1.0.x</category>
        <category domain="version">1.0.741</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Add support for DCC, Device Compatibility Code as improvement of BSP upgrade/downgrade process (DCC is stored in devices at manufacturing time)</li>
<li>Streamline BSP upgrade/downgrade with the use of DCC, Device Compatibility Code</li>
<li>Support new eMMC second source AGI 415/AGI 421</li>
<li>Support new USB HUB second source AGI 407/AGI 410/AGI 415/AGI 421</li>
<li>Enable autocalibration for touch screen</li>
<li>Application management in System Settings</li>
<li>Add support for forwarding rules on VPN, PPP and bridge interfaces</li>
<li>Add Spanish, Portuguese/Brazilian, Russian language</li>
<li>Added option to execute script autoexec.sh when SD is inserted</li>
<li>Add Korean and Traditional Chinese languages</li>
<li>Fixing support for projects larger than 240MB with Manage Target</li>
<li>Add access to OSS license information on BSP components in system settings</li>
<li>Add Japanese language</li>
<li>Add custom font management to System Settings for apps (Chromium, CODESYS)</li>
<li>Add mapping of USB to Serial interfaces to ttyS for use with CODESYS</li>
<li>Chromium - Minor issues in dialogs with small screens</li>
</ul>
<h3>Corrections/Improvements</h3>
<ul>
<li>BSP update occasionally fails updating mainos and configos</li>
<li>Local and Browser randomly reload System Settings pages also while user is editing</li>
<li>“Restore settings” will reset default values of fast boot, HW switch</li>
<li>Error uploading OpenVPN file config from browser</li>
<li>Error appearing during configuration via browser while connecting directly HMI to PC</li>
<li>NTP client and NTP server can be activated separately</li>
<li>CODESYS applications should be launched with read-write data partition in fast boot mode</li>
<li>Tap-tap not working when we enable fast boot</li>
<li>MAC address not returned correctly on bridged interfaces</li>
</ul>
<h3>Security Updates</h3>
<ul>
<li>Missing charset in Content-Type Fix to avoid potential attack by UTF-7 XSS</li>
<li>Update OpenVPN version for security reasons</li>
<li>Added https CA-certificates for Chromium app</li>
<li>Disable incoming NTP mode 6 queries</li>
<li>Cybersecurity fix CVE</li>
<li>Avoid DHCP spoofing vulnerability by not listening on TAP interface</li>
<li>Cyber Security: Web Server Error Page Information Disclosure</li>
<li>VNC Server crashes if malformed packets are sent</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware version 1.0.x &#x2013; v1.0.741U25</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-&#x8F6F;&#x4EF6;/1-0-741u25/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">80ffaed1-469f-4236-a122-ae11e2e08c28</guid>
        <pubDate>2022-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware version 1.0.x</category>
        <category domain="version">1.0.741U25</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Add support for DCC, Device Compatibility Code as improvement of BSP upgrade/downgrade process (DCC is stored in devices at manufacturing time)</li>
<li>Streamline BSP upgrade/downgrade with the use of DCC, Device Compatibility Code</li>
<li>Support new eMMC second source AGI 415/AGI 421</li>
<li>Support new USB HUB second source AGI 407/AGI 410/AGI 415/AGI 421</li>
<li>Enable autocalibration for touch screen</li>
<li>Application management in System Settings</li>
<li>Add support for forwarding rules on VPN, PPP and bridge interfaces</li>
<li>Add Spanish, Portuguese/Brazilian, Russian language</li>
<li>Added option to execute script autoexec.sh when SD is inserted</li>
<li>Add Korean and Traditional Chinese languages</li>
<li>Fixing support for projects larger than 240MB with Manage Target</li>
<li>Add access to OSS license information on BSP components in system settings</li>
<li>Add Japanese language</li>
<li>Add custom font management to System Settings for apps (Chromium, CODESYS)</li>
<li>Add mapping of USB to Serial interfaces to ttyS for use with CODESYS</li>
<li>Chromium - Minor issues in dialogs with small screens</li>
</ul>
<h3>Corrections/Improvements</h3>
<ul>
<li>BSP update occasionally fails updating mainos and configos</li>
<li>Local and Browser randomly reload System Settings pages also while user is editing</li>
<li>“Restore settings” will reset default values of fast boot, HW switch</li>
<li>Error uploading OpenVPN file config from browser</li>
<li>Error appearing during configuration via browser while connecting directly HMI to PC</li>
<li>NTP client and NTP server can be activated separately</li>
<li>CODESYS applications should be launched with read-write data partition in fast boot mode</li>
<li>Tap-tap not working when we enable fast boot</li>
<li>MAC address not returned correctly on bridged interfaces</li>
</ul>
<h3>Security Updates</h3>
<ul>
<li>Missing charset in Content-Type Fix to avoid potential attack by UTF-7 XSS</li>
<li>Update OpenVPN version for security reasons</li>
<li>Added https CA-certificates for Chromium app</li>
<li>Disable incoming NTP mode 6 queries</li>
<li>Cybersecurity fix CVE</li>
<li>Avoid DHCP spoofing vulnerability by not listening on TAP interface</li>
<li>Cyber Security: Web Server Error Page Information Disclosure</li>
<li>VNC Server crashes if malformed packets are sent</li>
<li>Update u-boot to version 25 to prevent display to be blank after sw reboot</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware version 1.0.x &#x2013; v1.0.756</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-&#x8F6F;&#x4EF6;/1-0-756/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">09a267d5-2bf4-41bf-bfae-e7a4a82e1e1e</guid>
        <pubDate>2022-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware version 1.0.x</category>
        <category domain="version">1.0.756</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Supports new Ethernet second source AGI407/AGI410/AGI415/AGI421.</li>
<li>Removed FPGA configuration in system settings for products with new Ethernet component.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware version 1.0.x &#x2013; v1.0.829</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-&#x8F6F;&#x4EF6;/1-0-829/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e759e34-17df-43ed-b09d-fe54ce743bb9</guid>
        <pubDate>2022-12-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware version 1.0.x</category>
        <category domain="version">1.0.829</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Support for hardware changes.</li>
<li>Bug fixes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware version 1.0.x &#x2013; v1.0.888</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-&#x8F6F;&#x4EF6;/1-0-888/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">505b0151-2d21-4063-85f7-38a8768843c2</guid>
        <pubDate>2025-07-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware version 1.0.x</category>
        <category domain="version">1.0.888</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Added support for new display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.0.x &#x2013; v1.0.535</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-&#x8F6F;&#x4EF6;/1-0-535/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">85db3d4a-6db2-452c-8973-58f5d5782a8a</guid>
        <pubDate>2020-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.0.x</category>
        <category domain="version">1.0.535</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Firewall support</li>
<li>NAT/Forward service support</li>
<li>Update PWM frequency backlight for 21.5” displays</li>
<li>Enable NTP local time reference clock</li>
</ul>
<h3>Corrections/Improvements</h3>
<ul>
<li>Improved event behavior when touchscreen is disabled</li>
<li>Cursor may not appear at boot with some mouse devices</li>
<li>800Kbit CAN baudrate support</li>
<li>Improved Ethernet messages in case of high network traffic </li>
<li>Software bridge not working via API</li>
<li>Screen remains black after toggling external timeout variable</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.0.x &#x2013; v1.0.535U22</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-&#x8F6F;&#x4EF6;/1-0-535u22/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">abe0ebf7-edd6-49bb-9c93-49b470deeb0a</guid>
        <pubDate>2021-06-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.0.x</category>
        <category domain="version">1.0.535U22</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p>UBOOT changed to U22 from U18 to simplify production - no customer functionality changes from previous version!</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.0.x &#x2013; v1.0.741</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-&#x8F6F;&#x4EF6;/1-0-741/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">979dddb8-0cda-426c-8cac-11b3fc0dfe46</guid>
        <pubDate>2021-12-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.0.x</category>
        <category domain="version">1.0.741</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Add support for DCC, Device Compatibility Code as improvement of BSP upgrade/downgrade process (DCC is stored in devices at manufacturing time)</li>
<li>Streamline BSP upgrade/downgrade with the use of DCC, Device Compatibility Code</li>
<li>Support new eMMC second source AGI 415/AGI 421</li>
<li>Support new USB HUB second source AGI 407/AGI 410/AGI 415/AGI 421</li>
<li>Enable autocalibration for touch screen</li>
<li>Application management in System Settings</li>
<li>Add support for forwarding rules on VPN, PPP and bridge interfaces</li>
<li>Add Spanish, Portuguese/Brazilian, Russian language</li>
<li>Added option to execute script autoexec.sh when SD is inserted</li>
<li>Add Korean and Traditional Chinese languages</li>
<li>Fixing support for projects larger than 240MB with Manage Target</li>
<li>Add access to OSS license information on BSP components in system settings</li>
<li>Add Japanese language</li>
<li>Add custom font management to System Settings for apps (Chromium, CODESYS)</li>
<li>Add mapping of USB to Serial interfaces to ttyS for use with CODESYS</li>
<li>Chromium - Minor issues in dialogs with small screens</li>
</ul>
<h3>Corrections/Improvements</h3>
<ul>
<li>BSP update occasionally fails updating mainos and configos</li>
<li>Local and Browser randomly reload System Settings pages also while user is editing</li>
<li>“Restore settings” will reset default values of fast boot, HW switch</li>
<li>Error uploading OpenVPN file config from browser</li>
<li>Error appearing during configuration via browser while connecting directly HMI to PC</li>
<li>NTP client and NTP server can be activated separately</li>
<li>CODESYS applications should be launched with read-write data partition in fast boot mode</li>
<li>Tap-tap not working when we enable fast boot</li>
<li>MAC address not returned correctly on bridged interfaces</li>
</ul>
<h3>Security Updates</h3>
<ul>
<li>Missing charset in Content-Type Fix to avoid potential attack by UTF-7 XSS</li>
<li>Update OpenVPN version for security reasons</li>
<li>Added https CA-certificates for Chromium app</li>
<li>Disable incoming NTP mode 6 queries</li>
<li>Cybersecurity fix CVE</li>
<li>Avoid DHCP spoofing vulnerability by not listening on TAP interface</li>
<li>Cyber Security: Web Server Error Page Information Disclosure</li>
<li>VNC Server crashes if malformed packets are sent</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.0.x &#x2013; v1.0.756</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-&#x8F6F;&#x4EF6;/1-0-756/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">939824f3-9106-4a8a-b9cc-74233f004195</guid>
        <pubDate>2022-02-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.0.x</category>
        <category domain="version">1.0.756</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Supports new Ethernet second source AGI407/AGI410/AGI415/AGI421</li>
<li>Removed FPGA configuration in system settings for products with new Ethernet component</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.0.x &#x2013; v1.0.829</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-&#x8F6F;&#x4EF6;/1-0-829/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a227ba13-c8fc-4909-afaf-39c899e3cf17</guid>
        <pubDate>2023-05-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.0.x</category>
        <category domain="version">1.0.829</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p>• Support for hardware changes<br />• Bug fixes</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.0.x &#x2013; v1.0.888</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-&#x8F6F;&#x4EF6;/1-0-888/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e86441e-3f0d-4a89-a0b5-82e82c9c464d</guid>
        <pubDate>2025-07-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.0.x</category>
        <category domain="version">1.0.888</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Added support for new display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp/1300/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d6a54111-872d-45cf-bded-96658e179234</guid>
        <pubDate>2021-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.0</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p>Contains related target hardware device description files, EtherCAT I/O device descriptions files and hardware related libraries.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp/1304/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b5a09e7e-4560-47c0-b191-445aeebd100a</guid>
        <pubDate>2022-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.4</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p>Release for second AMC 300 prototype test sw<br />#Added<br />Missing IFM51 devdesc versions<br />Missing IFM52 devdesc versions<br />Missing GPM51 devdesc versions</p>
<p>#Fixed<br />Increased log size for CODESYS<br />Fixed DIO6.1 module can not show the DO status #48</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0bc1c39d-e872-477a-9c66-3ec6936717bd</guid>
        <pubDate>2023-04-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20) &#x2013; v4.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-pcm31-&#x4EE3;&#x7801;&#x5305;/4-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c73b6583-8876-4ed6-8459-087723e4e8c8</guid>
        <pubDate>2021-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20)</category>
        <category domain="version">4.0.1.0</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h3>New:</h3>
<ul>
<li>Support for ACM3.2 and EIM3.1.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>- IOM firmware updates.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20) &#x2013; v4.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-pcm31-&#x4EE3;&#x7801;&#x5305;/4-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">889c9389-3dec-4fbf-8e90-4407eab9a715</guid>
        <pubDate>2021-06-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20)</category>
        <category domain="version">4.0.2.0</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h3>New:</h3>
<ul>
<li>Ports and Protocols in Firewall are opened to allow CODESYS PLC handler communication (for example, for interface with AGI4xx).</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Support for GAM 3.1 modules is added.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20) &#x2013; v4.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-pcm31-&#x4EE3;&#x7801;&#x5305;/4-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8bf77409-321b-4e87-b5bc-8e06308219ff</guid>
        <pubDate>2021-09-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20)</category>
        <category domain="version">4.0.3.0</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Change in firewall to allow CODESYS PLC handler communication (for example, for interface with AGI4xx).</li>
<li>Support for GAM 3.1 modules is added.</li>
<li>Network configuration improved to only show "save to startup" if there is a change pending, and IP is routable.</li>
<li>Reset and factory reset added to web app. Permission limited to admin only. </li>
<li>IOM 3.4 module outputs now working as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20) &#x2013; v4.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-pcm31-&#x4EE3;&#x7801;&#x5305;/4040/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e5e0224-83be-4863-b1a5-e900ef86d7fa</guid>
        <pubDate>2021-11-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 PCM3.1 Code package (CODESYS SP15 Patch 20)</category>
        <category domain="version">4.0.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Enabled SCP and SFTP from customer services/application</li>
<li>Firewall extended to allow CODESYS PLC handler communication</li>
<li>Support for GAM 3.1 modules is added</li>
<li>Network configuration improved to only show "save to startup" if there is a change pending, and IP is routable</li>
<li>Reset and factory reset added to web app. Permission limited to admin only.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>CIO xxx Application Software &#x2013; v1.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/cio-xxx-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ef171127-0080-44e9-8170-3860d6057ca9</guid>
        <pubDate>2016-10-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CIO xxx Application Software</category>
        <category domain="version">1.10.0</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>CIO 116</li>
<li>CIO 208</li>
<li>CIO 308 <br><strong>​</strong></li>
</ul>
<h3>New features:</h3>
<ul>
<li>Support for CIO308.</li>
<li>Duplicate CAN ID detection</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>CIO xxx Application Software &#x2013; v1.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/cio-xxx-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8ea263ec-0d10-4cde-9a60-e98dafddf111</guid>
        <pubDate>2018-04-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CIO xxx Application Software</category>
        <category domain="version">1.10.1</category>
          <category domain="release-status">current</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>CIO 308 improved limit check.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350/550 EasyReg Advanced Utility Software &#x2013; v1.1.3.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/deif-easyreg-&#x9AD8;&#x7EA7;&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-1-3-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c432de7f-a5f3-4a5e-9d06-50369d341b7c</guid>
        <pubDate>2020-10-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 350/550 EasyReg Advanced Utility Software</category>
        <category domain="version">1.1.3.2</category>
          <category domain="product">DVC 350</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<p>Trending issue now solved.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350/550 EasyReg Advanced Utility Software &#x2013; v1.2.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/deif-easyreg-&#x9AD8;&#x7EA7;&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-2-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c50fc401-2f94-460a-8083-1b80d0facb62</guid>
        <pubDate>2021-05-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 350/550 EasyReg Advanced Utility Software</category>
        <category domain="version">1.2.1.0</category>
          <category domain="product">DVC 350</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>PSS function in DVC550 is now supported.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected an issue, where during the generation of the Easylog configuration file, the software could crash in function of the setting.</li>
<li>Corrected an issue, where the limits for analogue inputs used for for the voltage set point were not updated when a machine was selected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350/550 EasyReg Advanced Utility Software &#x2013; v1.1.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/deif-easyreg-&#x9AD8;&#x7EA7;&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-1-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dabb33ed-1e2e-4137-8b80-f66778fabcab</guid>
        <pubDate>2020-11-02T16:22:04&#x2B;00:00</pubDate>
        <category domain="software">DVC 350/550 EasyReg Advanced Utility Software</category>
        <category domain="version">1.1.3.1</category>
          <category domain="product">DVC 350</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<p>Minor graphical changes</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350/550 EasyReg Advanced Utility Software &#x2013; v1.2.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/deif-easyreg-&#x9AD8;&#x7EA7;&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-2-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8adc802d-88fb-45b5-a4f9-580c64645d2b</guid>
        <pubDate>2022-09-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 350/550 EasyReg Advanced Utility Software</category>
        <category domain="version">1.2.5.0</category>
          <category domain="product">DVC 350</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>DVC 350 support added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Translations added.</li>
<li>The memorisation of the inversion of the inputs of the logic gates did not work.</li>
<li>Inaccessibility to the setting of the faster slower on the CosPhi network.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350/550 EasyReg Advanced Utility Software &#x2013; v1.2.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/deif-easyreg-&#x9AD8;&#x7EA7;&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-2-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9a3a9cf0-0c74-4dba-9311-ff0c9419b5d2</guid>
        <pubDate>2023-12-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 350/550 EasyReg Advanced Utility Software</category>
        <category domain="version">1.2.6.0</category>
          <category domain="product">DVC 350</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Activation new analogue input mode for DVC 350.</li>
</ul>
<p>&nbsp;</p>
<h3>Corrections:</h3>
<ul>
<li>Translations corrections for DVC 550.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350/550 EasyReg Advanced Utility Software &#x2013; v2.1.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/deif-easyreg-&#x9AD8;&#x7EA7;&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-1-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">69d59df1-265e-4de5-ae77-7583c36bbb29</guid>
        <pubDate>2025-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 350/550 EasyReg Advanced Utility Software</category>
        <category domain="version">2.1.8.0</category>
          <category domain="release-status">current</category>
          <category domain="product">DVC 350</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<h3>General updates</h3>
<ul>
<li>Improved user interface and communication security.</li>
<li>It is now possible to connect to more than one automatic voltage regulator (AVR) at a time.</li>
<li>Optimised execution time.</li>
<li>Added checks and error handling to improve system robustness.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Delomatic 4 Utility Software &#x2013; v1.03.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/delomatic-4-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-03-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b2ddb342-0068-407d-be49-036c0af97657</guid>
        <pubDate>2016-06-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Delomatic 4 Utility Software</category>
        <category domain="version">1.03.4</category>
          <category domain="product">DM-4 marine</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Extented log with trigger value.</li>
<li>Added support for min. and sec</li>
<li>Changed application allways starts up on pos. 0,0.<br /><br /></li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bug: Some timers can not be changed.</li>
<li>Bug: Connection problem with USW after save all DGUs file.</li>
<li>Bug: Printed parameter report dosen't write appl version correct.</li>
<li>Bug: Sometimes reads and saves to many failclass texts.</li>
<li>Bug: SaveAllParams sequence is not stopped on cancel.</li>
<li>Minor change to appl. ver. in print handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Delomatic 4 Utility Software &#x2013; v1.03.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/delomatic-4-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-03-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">61366a21-0da8-42f0-8da6-df0d973333b4</guid>
        <pubDate>2020-05-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Delomatic 4 Utility Software</category>
        <category domain="version">1.03.5</category>
          <category domain="release-status">current</category>
          <category domain="product">DM-4 marine</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Disable ID select when IP is selected</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bug: Open and save dpm-file changes DM45 format to DM41 format</li>
<li>Bug: Locked parameters not displayed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 310 Application Software &#x2013; v2.30</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/dvc-310-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/2-30/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a59af0cd-498e-420d-a9aa-19915e61bb10</guid>
        <pubDate>2017-05-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 310 Application Software</category>
        <category domain="version">2.30</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<p>Easyreg compatibility: 2.60<br /><br />New features: <br />        Restart of DVC 310 from Easyreg<br />Adjustable Soft start reset timer<br />Adjustable Manual mode Soft start timer<br /><br />Changes: <br />        +/-10 V DC input has been changed to 0 to 10V DC<br />Maximum primary side CT setting changed to 5000 A<br /><br />Corrections:<br />Bumpless transfer during start-up<br />Handling of over-voltage alarm during stop of genset has been improved<br />Improved handling of current measuring at low levels</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 550 Application Software &#x2013; v1.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/dvc-550-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2231e483-4396-449a-aac9-567a3f0d9b34</guid>
        <pubDate>2021-05-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 550 Application Software</category>
        <category domain="version">1.2</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<p>DEIF EasyReg Advanced compatibility: 1.2.1.</p>
<h3>New features:</h3>
<ul>
<li>PSS function.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Factory setting function is optimized.</li>
<li>Excitation chain fault detection is improved.</li>
<li>Loss of sensing fault detection is improved.</li>
<li>Unbalance fault detection is improved.</li>
<li>FFT on excitation current measurement is improved.</li>
<li>CAN bus general communication is improved.</li>
<li>Overheating limitation management</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 550 Application Software &#x2013; v1.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/dvc-550-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4846ce37-92b0-4f4a-b0ac-70e483ece1e2</guid>
        <pubDate>2020-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 550 Application Software</category>
        <category domain="version">1.1</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<p>DVC 550 EasyReg Advanced compatibility:1.1.3.0</p>
<p>Initial release</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 550 Application Software &#x2013; v1.2.17</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/dvc-550-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-2-17/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ec311742-3b20-423d-9452-fd2eec7797e5</guid>
        <pubDate>2025-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 550 Application Software</category>
        <category domain="version">1.2.17</category>
          <category domain="release-status">current</category>
          <category domain="product">DVC 550</category>
        <content:encoded><![CDATA[
<h4>1.2.17 based on 1.2</h4>
<h3>&nbsp;Corrections:</h3>
<ul>
<li>Creation of an offset on the EEPROM addresses of all parameters, in order to recover product that runs out of EEPROM.</li>
<li>Add a parameter to store RAM in EEPROM every X minutes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 310 EasyReg Utility Software &#x2013; v2.50.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/easyreg-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-50-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e6e415a2-f93a-4648-8d2d-5ba3eef22742</guid>
        <pubDate>2015-09-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 310 EasyReg Utility Software</category>
        <category domain="version">2.50.0</category>
          <category domain="product">DVC 310</category>
        <content:encoded><![CDATA[
<p>Initial release</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 310 EasyReg Utility Software &#x2013; v2.60.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/easyreg-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-60-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b5978307-e148-40e3-8154-f410718fbe0a</guid>
        <pubDate>2017-05-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 310 EasyReg Utility Software</category>
        <category domain="version">2.60.0</category>
          <category domain="release-status">current</category>
          <category domain="product">DVC 310</category>
        <content:encoded><![CDATA[
<p>New features: <br />        Restart of DVC 310 from Easyreg<br />Adjustable soft start reset timer<br />Adjustable manual mode soft start timer<br /><br />Changes: <br />        +-10 VDC input has been removed<br />Maximum primary side CT setting changed to 5000 A<br /><br />Corrections:<br />Bumpless transfer during start-up<br />Handling of overvoltage alarm during stop of genset has <br />        been improved<br />Improved handling of current measuring at low levels</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>FX30 driver package &#x2013; v1.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/fx30-&#x9A71;&#x52A8;&#x5305;/1-0-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dc7765e3-649b-42de-9c5e-15d753c8623f</guid>
        <pubDate>2017-10-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">FX30 driver package</category>
        <category domain="version">1.0.0.0</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<p>Initial version of Windows driver for FX30 module</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>KNX Application file &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/knx-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6e11deeb-8685-424a-862d-1390b1bf5e28</guid>
        <pubDate>2011-03-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">KNX Application file</category>
        <category domain="version">1.00.0</category>
          <category domain="product">AEM 380 &amp; 305</category>
          <category domain="product">APM 380 &amp; 305</category>
        <content:encoded><![CDATA[
<p>Initial release</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>KNX Application file &#x2013; v1.01.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/knx-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-01-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a43fb80f-3b5c-408d-9aee-b51566398640</guid>
        <pubDate>2012-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">KNX Application file</category>
        <category domain="version">1.01.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AEM 380 &amp; 305</category>
          <category domain="product">APM 380 &amp; 305</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<p>Added V, A, kVA, PF and Hz support</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Link to MIC datalogging Software &#x2013; v1.00.13</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-&#x8FDE;&#x63A5;&#x6570;&#x636E;&#x8BB0;&#x5F55;&#x8F6F;&#x4EF6;&#x5305;/1-00-13/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6f2fcf72-f9ef-4138-a5ba-772c38f214bb</guid>
        <pubDate>2007-03-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Link to MIC datalogging Software</category>
        <category domain="version">1.00.13</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<p>1.00.13 11-10-2007 - Help file updated.<br />1.00.13 03-07-2007 - Initial version<br />1.00.13 03-07-2007 - Initial version</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>M-SET MIQ MTR Utility Software &#x2013; v2.1.0.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/m-set-miq-mtr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-1-0-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c466441e-7982-454a-a778-7361204bf018</guid>
        <pubDate>2017-10-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">M-SET MIQ MTR Utility Software</category>
        <category domain="version">2.1.0.5</category>
          <category domain="product">MTR-4</category>
          <category domain="product">MTR-4P</category>
          <category domain="product">MIQ96-2</category>
          <category domain="product">MIQ96-3</category>
          <category domain="product">MTR-2</category>
          <category domain="product">MTR-3</category>
        <content:encoded><![CDATA[
<p>Support for MTR-4P variants added.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>M-SET MIQ MTR Utility Software &#x2013; v2.1.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/m-set-miq-mtr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-1-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e72e7a18-97f6-413d-aa58-59300fceb58e</guid>
        <pubDate>2018-06-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">M-SET MIQ MTR Utility Software</category>
        <category domain="version">2.1.0.8</category>
          <category domain="product">MTR-4</category>
          <category domain="product">MTR-4P</category>
          <category domain="product">MIQ96-2</category>
          <category domain="product">MIQ96-3</category>
          <category domain="product">MTR-2</category>
          <category domain="product">MTR-3</category>
        <content:encoded><![CDATA[
<p>Improvements and corrections</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>M-SET MIQ MTR Utility Software &#x2013; v2.1.0.9</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/m-set-miq-mtr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-1-0-9/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d4d48996-040d-4350-985f-99c25294db23</guid>
        <pubDate>2023-07-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">M-SET MIQ MTR Utility Software</category>
        <category domain="version">2.1.0.9</category>
          <category domain="product">MTR-4</category>
          <category domain="product">MTR-4P</category>
          <category domain="product">MIQ96-2</category>
          <category domain="product">MIQ96-3</category>
          <category domain="product">MTR-2</category>
          <category domain="product">MTR-3</category>
        <content:encoded><![CDATA[
<p><strong>Changes</strong></p>
<ul>
<li>Support for MTR-4 2RO, 1AO (2962390110.09) added</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>M-SET MIQ MTR Utility Software &#x2013; v2.1.0.13</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/m-set-miq-mtr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-1-0-13/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ec8672a6-25bf-40d8-a19c-8f946006533e</guid>
        <pubDate>2025-10-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">M-SET MIQ MTR Utility Software</category>
        <category domain="version">2.1.0.13</category>
          <category domain="product">MTR-4</category>
          <category domain="product">MTR-4P</category>
          <category domain="product">MIQ96-2</category>
          <category domain="product">MIQ96-3</category>
          <category domain="product">MTR-2</category>
          <category domain="product">MTR-3</category>
        <content:encoded><![CDATA[
<p><strong>Changes</strong></p>
<ul>
<li>Firmware upgrade option added to M-set USW for MTR.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>M-SET MIQ MTR Utility Software &#x2013; v2.1.0.14</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/m-set-miq-mtr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-1-0-14/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">32e87733-a00a-43f5-bd2a-d3c11121c2aa</guid>
        <pubDate>2026-02-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">M-SET MIQ MTR Utility Software</category>
        <category domain="version">2.1.0.14</category>
          <category domain="release-status">current</category>
          <category domain="product">MTR-4</category>
          <category domain="product">MTR-4P</category>
          <category domain="product">MIQ96-2</category>
          <category domain="product">MIQ96-3</category>
          <category domain="product">MTR-2</category>
          <category domain="product">MTR-3</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue that prevented users from entering decimal values other than .0 or .5.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MBus Master Utility Software &#x2013; v2.51.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mbus-master-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-51-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d12e9a0e-509b-4fae-8556-2119d01762ce</guid>
        <pubDate>2012-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MBus Master Utility Software</category>
        <category domain="version">2.51.0</category>
          <category domain="product">AEM 380 &amp; 305</category>
          <category domain="product">APM 380 &amp; 305</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Added V, A, kVA, PF and Hz values support</li>
<li>Technical Reference updated</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MBus Master Utility Software &#x2013; v2.52.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mbus-master-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-52-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9e481a09-6bab-4782-a897-cc59098f84ef</guid>
        <pubDate>2014-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MBus Master Utility Software</category>
        <category domain="version">2.52.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AEM 380 &amp; 305</category>
          <category domain="product">APM 380 &amp; 305</category>
        <content:encoded><![CDATA[
<h3>Change:</h3>
<ul>
<li>Change of data resolution on the MBus readout.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIB 7000C utility software &#x2013; v2.30.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mib-7000c-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-30-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9e399355-bee4-4429-8c60-20f4caae8111</guid>
        <pubDate>2009-03-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIB 7000C utility software</category>
        <category domain="version">2.30.0</category>
          <category domain="release-status">current</category>
          <category domain="product">MIB 7000</category>
        <content:encoded><![CDATA[
<p>First release</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC Utility Software &#x2013; v1.2.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-2-14-0-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d1fd10f8-4d7e-44f3-b645-08b4c18c79fd</guid>
        <pubDate>2007-10-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC Utility Software</category>
        <category domain="version">1.2.14.0</category>
          <category domain="release-status">current</category>
          <category domain="product">MIC</category>
        <content:encoded><![CDATA[
<p>Error in zip file.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC-2 Profi-Bus GSD-file &#x2013; v2.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-2-profi-bus-gsd-&#x6587;&#x4EF6;/2-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3854da42-0b2b-4828-b135-b83d7ebb7b27</guid>
        <pubDate>2010-09-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC-2 Profi-Bus GSD-file</category>
        <category domain="version">2.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">MIC-2</category>
        <content:encoded><![CDATA[
<p>Initial release</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC-2 Utility Software - DEIF View &#x2013; v3.40.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-deif-view/3-40-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">47bcfdf6-cbf9-4369-9313-9bf38a2588a2</guid>
        <pubDate>2015-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC-2 Utility Software - DEIF View</category>
        <category domain="version">3.40.7</category>
          <category domain="product">MIB 8000C</category>
          <category domain="product">MIC-2 MKII</category>
          <category domain="product">MIC-2 MKII DIN</category>
          <category domain="product">MIC-2 MKII FCT</category>
          <category domain="product">MIC-2 MKII FCT DIN</category>
          <category domain="product">MIB 8000</category>
          <category domain="product">MIC-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support for MIC-2 MKII, MIC-2 MKII DIN</li>
<li>Pulse constant calculator tool added (separate tool)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC-2 Utility Software - DEIF View &#x2013; v3.40.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-deif-view/3-40-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a2b70b88-cc48-42d1-8bf5-2a17e8d91d33</guid>
        <pubDate>2018-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC-2 Utility Software - DEIF View</category>
        <category domain="version">3.40.8</category>
          <category domain="product">MIB 8000C</category>
          <category domain="product">MIC-2 MKII</category>
          <category domain="product">MIC-2 MKII DIN</category>
          <category domain="product">MIC-2 MKII FCT</category>
          <category domain="product">MIC-2 MKII FCT DIN</category>
          <category domain="product">MIB 8000</category>
          <category domain="product">MIC-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support for new MIC-2 MKII FCT with mV input for flexible current transformers.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC-2 Utility Software - DEIF View &#x2013; v3.70.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-deif-view/3-70-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">100ae858-9576-48eb-bf4c-92a72653ce5a</guid>
        <pubDate>2023-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC-2 Utility Software - DEIF View</category>
        <category domain="version">3.70.4</category>
          <category domain="product">MIB 8000C</category>
          <category domain="product">MIC-2 MKII</category>
          <category domain="product">MIC-2 MKII DIN</category>
          <category domain="product">MIC-2 MKII FCT</category>
          <category domain="product">MIC-2 MKII FCT DIN</category>
          <category domain="product">MIB 8000</category>
          <category domain="product">MIC-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support for MIB-8000 added</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC-2 Utility Software - DEIF View &#x2013; v3.71.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-deif-view/3-71-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">186baf6c-25d2-49dd-943b-ad904a3a18f7</guid>
        <pubDate>2024-07-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC-2 Utility Software - DEIF View</category>
        <category domain="version">3.71.0</category>
          <category domain="product">MIB 8000C</category>
          <category domain="product">MIC-2 MKII</category>
          <category domain="product">MIC-2 MKII DIN</category>
          <category domain="product">MIC-2 MKII FCT</category>
          <category domain="product">MIC-2 MKII FCT DIN</category>
          <category domain="product">MIB 8000</category>
          <category domain="product">MIC-2</category>
        <content:encoded><![CDATA[
<h4><strong>This software applies to the following DEIF products:</strong><br><strong>MIC-2 MKII</strong><br><strong>MIB-8000C</strong></h4>
<h3>New features:</h3>
<ul>
<li>Support for MIB-8000C added</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MIC-2 Utility Software - DEIF View &#x2013; v3.71.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mic-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-deif-view/3-71-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">406da6b1-e80e-46b6-9d93-12fa152db0e3</guid>
        <pubDate>2025-10-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MIC-2 Utility Software - DEIF View</category>
        <category domain="version">3.71.4</category>
          <category domain="release-status">current</category>
          <category domain="product">MIB 8000C</category>
          <category domain="product">MIC-2 MKII</category>
          <category domain="product">MIC-2 MKII DIN</category>
          <category domain="product">MIC-2 MKII FCT</category>
          <category domain="product">MIC-2 MKII FCT DIN</category>
          <category domain="product">MIB 8000</category>
          <category domain="product">MIC-2</category>
        <content:encoded><![CDATA[
<h4><strong>This software applies to the following DEIF products:</strong><br><strong>MIC-2 MKII</strong><br><strong>MIB-8000C</strong></h4>
<h3>Major changes</h3>
<ul>
<li>Improvements to PROFI module information in the Device information page.</li>
</ul>
<h3>Minor changes</h3>
<ul>
<li>Improved the stability of the Time-of-Use (TOU) function.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Modbus Master Utility Software &#x2013; v1.01.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/modbus-master-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-01-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a43a3bc8-c861-4077-927e-ce7048ea00ce</guid>
        <pubDate>2012-03-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Modbus Master Utility Software</category>
        <category domain="version">1.01.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AEM 380 &amp; 305</category>
          <category domain="product">APM 380 &amp; 305</category>
        <content:encoded><![CDATA[
<p>Changes made to support new updated Modbus Interface</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AFC PM Application Software series 5.x. &#x2013; v5.00.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-afc-pm-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-5x-&#x7CFB;&#x5217;/5-00-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9013eab1-9962-4261-a31a-ed3b77984cc5</guid>
        <pubDate>2015-09-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AFC PM Application Software series 5.x.</category>
        <category domain="version">5.00.2</category>
          <category domain="release-status">current</category>
          <category domain="product">AFC plant management</category>
        <content:encoded><![CDATA[
<p>FM version 2.00.0</p>
<h3>Corrections:</h3>
<ul>
<li>Reliability data was not kept past a power cycle.</li>
<li>Update of self-check functionality.</li>
<li>Unit would reset in case left button was pushed whilst being on left submenu in menu 9000.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 100 Application Software series 4.xx &#x2013; v4.55.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-100-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4xx-&#x7CFB;&#x5217;/4-55-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d129a9ba-67fe-4e94-9624-a00af222d1fc</guid>
        <pubDate>2017-04-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 100 Application Software series 4.xx</category>
        <category domain="version">4.55.0</category>
          <category domain="product">Remote Access Support</category>
          <category domain="product">AGC 100</category>
        <content:encoded><![CDATA[
<p>Changes:<br />1- Sleep mode can no longer be disabled.<br />2- The sleep mode timer will now start running even though an unacknowledged alarm is present.<br /><br />Corrections:<br />1- When a mains is instructed to switch to a DG supply, it first checks if there is an available DG supply before opening the MB.<br />2- Fixed issue with GSM modem communication.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 100 Application Software series 4.xx &#x2013; v4.55.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-100-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4xx-&#x7CFB;&#x5217;/4-55-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">346e0a98-022e-4d7d-b7d3-4c2f98d5a416</guid>
        <pubDate>2017-09-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 100 Application Software series 4.xx</category>
        <category domain="version">4.55.1</category>
          <category domain="release-status">current</category>
          <category domain="product">Remote Access Support</category>
          <category domain="product">AGC 100</category>
        <content:encoded><![CDATA[
<p><br />Corrections:<br />1- Corrected a bug that caused Beckhoff digital outputs to flicker.<br />2- Corrected a bug that prevented multi-inputs configured as binary inputs and Beckhoff digital inputs from being used with virtual inputs.<br />3- Support of checksum in TSC1 telegram added for Volvo-Penta EMS 2.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.05.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-05-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0c1cc7b5-3a80-4bc3-8f0c-db0ef110b2fe</guid>
        <pubDate>2021-01-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.05.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.</p>
<h3>Corrections:</h3>
<ul>
<li> Support is added for Volvo engine with 60 Hz as primary speed when Volvo proprietary engine speed is used.</li>
<li> Generator under-frequency and under-voltage alarms are now inhibited during idle run.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.05.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-05-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2fd6ca1d-75f5-4033-bd53-d5060458f194</guid>
        <pubDate>2021-04-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.05.4</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.</p>
<h3>Corrections:</h3>
<ul>
<li>HYBRID: When reconfiguration of the RS-485 ports, power cycle of the unit is no longer needed.</li>
<li>HYBRID: The unit is now able to automatically switch between Sunspec addresses (40000, 50000 and 0). If Sunspec initialization is not compatible, reinitialization starts in 20 seconds.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.09.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-09-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">36536114-b619-48d9-a098-961412e3a8c9</guid>
        <pubDate>2021-12-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.09.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<h3>New features:</h3>
<ul>
<li>DG HYBRID: Added GoodWe HT Series PV protocol.</li>
<li>DG HYBRID: Huawei V.3 PV protocol added. This protocol replaces all older Huawei protocols for newer inverter firmware versions.</li>
<li>M-Logic input events for auto start command from any DG, any MAINS or any BATTERY in Plant.</li>
<li>RPM based on calculation from the AC frequency reading.</li>
<li>DG HYBRID: Added Havells 1-40kw PV protocol.</li>
<li>DG HYBRID: Added Havells 50-70kw PV protocol.</li>
<li>DG HYBRID: Added Sofar Solar 1-40kw PV protocol.</li>
<li>DG HYBRID: Added Sofar Solar 50-70kw PV protocol.</li>
<li>DG HYBRID: Added Chint (CPS) Boost 100-250kW PV protocol.</li>
<li>M-Logic command for turning display backlight and all LEDs OFF added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>PM-id added to lower info line together with page-number and PM-prio.</li>
<li>Multi-input wire-break setup: Delay, Auto acknowledge and Inhibit added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>No ASC-4 PV irradiance sensor could make AGC DG's provide inadequate power for mains power export.</li>
<li>Cosphi superior set points now work with only PV or Battery units on the busbar together with a AGC 150 mains.</li>
<li>EIC and CIO communication can run at the same time again.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.06.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-06-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4f5331ce-b4c1-4ba2-abd0-6fb8e803240d</guid>
        <pubDate>2021-05-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.06.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>Version 1.06.1 based on 1.06.0.</p>
<p>PM compatibility: 1.23.0.</p>
<h3>Corrections:</h3>
<ul>
<li>Limit events is added in M-Logic for Extended M-Logic Alarms.</li>
<li>DVC 550/D550 now works with the EIC protocol Volvo Penta EMS 2.4.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.04.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-04-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">619f8c26-4f18-415c-afa8-3d7db6145360</guid>
        <pubDate>2020-09-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.04.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.17.2.</p>
<h3>Corrections:</h3>
<ul>
<li>&nbsp; &nbsp;TEST type in StandAlone (option S1) is limited to SIMPLE TEST.</li>
<li>&nbsp; &nbsp;Limit evaluation of multi-input 23 alarm for use in M-Logic is now working.</li>
<li>&nbsp; &nbsp;Included CAN Start/Stop in the Hatz proprietary CM1 telegram.</li>
<li>&nbsp; &nbsp;Current handling of TIER 4 icons for the Hatz protocol.</li>
<li>&nbsp; &nbsp;Read Aftertreatment 1 Intake Gas telegram for the Hatz protocol.</li>
<li>&nbsp; &nbsp;Necessary to force a regeneration until current feedback is received from ECU.</li>
<li>&nbsp; &nbsp;Fuel optimization + running hours does not swap DG's at fixed load.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.06.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-06-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7253e62c-f44d-4eb9-8b22-24804299bc43</guid>
        <pubDate>2021-04-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.06.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.23.0.</p>
<h3>New features:</h3>
<ul>
<li>DG HYBRID: Added new parameter #17132 "Curtail threshold".</li>
<li>Added support for John Deere Stage V EIC protocol.</li>
<li>Added support for Isuzu EIC protocol.</li>
<li>Added new parameter #6176 "Not running delay". Can be used as a hysteresis if the running feedback unexpectedly falls under the running detection level.</li>
<li>Added support for Kohler EIC protocol.</li>
<li>Added support for FPT + Iveco Stage V EIC protocol.</li>
<li>Added four new M-Logic alarms with extended delay in menu 3620-3650.</li>
<li>Added Event log entry when the application setup changes.</li>
<li>DG HYBRID: Added monitoring tool for Modbus master communication within the service view under communication analysis.</li>
<li>Added new GOV and AVR step test in parameter group #2970.</li>
<li>DG HYBRID: Added support for Sungrow Logger 1000 PV protocol.</li>
<li>DG HYBRID: Added support for Growatt PV protocol.</li>
<li>Added keyswitch for Diesel engine.</li>
<li>Added new controller type 'Engine Drive'.<br />• Added MPU and EIC speed as PID1 input.<br />• Added EIC as PID1 output.<br />• Added digital input functions to control PID1 output (Semi manual mode).<br />• Added ramp functionality for PID1.<br />• Added new shortcut menu (Engine shortcuts).</li>
<li>DG HYBRID: Added support of PV breaker.</li>
<li>EIC speed (SPN 190) and MPU speed added to delta alarms.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Default views for DG are changed.</li>
<li>Engine I/F list is reorganized in alphabetical order.</li>
<li>Fuel pump logic is available for Stand-alone and Core software versions.</li>
<li>The SunSpec identifying information shown in the display is improved.</li>
<li>PV protocols are listed in alphabetic order in the display and the USW.</li>
<li>DG HYBRID: Added fallback timer for power limit on SunSpec (Parameter 17180).</li>
<li>Minimum timer for AC busbar alarms is decreased from 0.1 to 0.04 seconds.</li>
<li>Text is changed in the shortcut menu.</li>
<li>Engine emission system failure Tier4 icon now follows FMI levels and SPN3349 set to 7 for protocols with 10 ms transmission rate.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Menu 6231 for GB close delay is no longer available when the application is power management.</li>
<li>Corrected that strange texts sometimes were shown in the USW log.</li>
<li>"L-L and P total" view now shows the correct value.</li>
<li>Power factor set point on Modbus is now correctly initialized after power-up.</li>
<li>General improvements to the D550/DVC 550 integration module.</li>
<li>Ph-ph voltage will not saturate before the hardware limit is reached.</li>
<li>Correct behavior of dfdt is now ensured when the number of periods are set above 12.</li>
<li>The variable needed for angle check in Q dep U&lt; alarm is updated.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.08.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-08-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">795baddf-a470-4664-8d15-46030939c8a3</guid>
        <pubDate>2021-12-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.08.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<h3>Corrections:</h3>
<ul>
<li>Minimum load was not respected when using droop curve 1.</li>
<li>'Guided view with genset' now shows start/stop buttons equal on all DG's in an ISLAND PMS setup.</li>
<li>DG HYBRID: Added correct scaling for P/Q reference and changed the Broadcast ID to be 0xFF in the Polycab 50-60kW PV protocol.</li>
<li>EIC generic J1939: Missing data readings (SPN 1119 and 1180) added to protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.05.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-05-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cc957300-9dce-4446-9115-dba0e99a8088</guid>
        <pubDate>2021-03-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.05.3</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.</p>
<h3>Corrections:</h3>
<ul>
<li>Secured mode now works when Fuel optimisation is in use.</li>
<li>Priority update now works when more than 16 gensets or more than 16 mains are present in a plant configuration.</li>
<li>PMS priority data is properly maintained internally in all genset controllers.</li>
<li>When digital input 50 is not used as feedback, it is no longer disturbing the check of breaker status.</li>
<li>Breaker feedbacks are properly updated on the I/O status and the I/O setup page.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.08.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-08-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ce63fb1e-3d41-4b8c-a274-4c70b32f4909</guid>
        <pubDate>2021-11-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.08.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<h3>New features:</h3>
<ul>
<li>PMS redundancy via Ethernet added.</li>
<li>DG HYBRID: Added Modbus TCP/IP master communication support for PV and weather Modbus interfaces.</li>
<li>DG HYBRID: New weather protocol for POA and BOM reading: Kipp &amp; Zonen - RT1 Smart Rooftop Monitoring System.</li>
<li>Added support of Cummins KTA19 EIC protocol.</li>
<li>Added electrical load telegram to Caterpillar engine I/F.</li>
<li>DG HYBRID: Havells 80-136kW PV protocol added.</li>
<li>DG HYBRID: Polycab 50-60kW PV protocol added.</li>
<li>DG HYBRID: FIMER PVS980 PV protocol added.</li>
<li>Power ramp improved.</li>
<li>Added support of Jichai EIC protocol.</li>
<li>Added supported ECU types.</li>
<li>Added Preheat functionality for Perkins Stage V.</li>
<li>NTP Support added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Maximum timer extended to 3200.0 s on a number of protections (AC, digital inputs, MPU, EIC).</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>QSPI communication speed corrected.</li>
<li>Self-check error 49 during read of log.</li>
<li>DG HYBRID: EVVO PV active power control corrected.</li>
<li>ISLAND deload of last GB now works as expected, so the GB opens when the frequency has dropped 0.5 Hz below nominal.</li>
<li>Deload TB before GB opens function works correctly in PEAK SHAVING.</li>
<li>FULL TEST available again. Was taken out in 1.04.2.</li>
<li>DG HYBRID: POA and other weather-station values can now be written with DEIF OPEN communication.</li>
<li>Analogue output limits for transducer output corrected, so min/max on input is reflected directly to output limits.</li>
<li>PMS priority change via M-Logic or Modbus now works correctly.</li>
<li>Fast OverCurrent max set point reduced from 350 % to 300 % due to alignment with data sheet. Backward compatibility compromised.</li>
<li>If the ground relay was enabled and the application configuration was a non-PMS single DG, the GB would not open when deloaded.</li>
<li>df/dt now operates on the mains side measurements.</li>
<li>Configuration of outputs 15-18 is now correct after power cycle.</li>
<li>Alarm texts are shown when the alarm is reviewed from CAT EMCP.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.04.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-04-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e607d129-cb3d-4cdb-b845-29143c07438c</guid>
        <pubDate>2020-07-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.04.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>Version 1.04.1 based on 1.04.0<br><br>PM compatibility: 1.17.2</p>
<h3>Corrections:</h3>
<ul>
<li>Errors regarding powermanagement applications with PV, ASC and battery controller corrected.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.05.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-05-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f18bfb2f-9854-4812-865a-63dce6c2b94c</guid>
        <pubDate>2020-12-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.05.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.</p>
<h3>Corrections:</h3>
<ul>
<li> AGC 150 Hybrid controller got stuck in Sunspec initialize, due to a previously unknown Modbus model in the ABB PVS175 PV inverter.</li>
<li> Transmitting DVC 550/D550 parameters over the CAN was irregular. This is corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.07.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-07-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fac2cf3e-b63f-4186-a9ad-1098406cc2a5</guid>
        <pubDate>2021-06-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.07.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.1.</p>
<h3>New features:</h3>
<ul>
<li>Multiple busbars on CANshare is implemented, and 64 BTBs are available.</li>
<li>Remote display functionality is added. This includes a new controller type.</li>
<li>Reverse power: 3 AC protections are added.</li>
<li>Support of Perkins Stage V EIC protocol is added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>MAINS connection are now allowed in the STAND ALONE variant and none GB or external GB.</li>
<li>DG HYBRID: PV semi start/stop commands are added to M-Logic and to the Modbus commands.</li>
<li>Weichai gas EIC protocol is updated with new data readings.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>"Fuel optimization" and "Fuel optimization + running hours" are now working with percent values.</li>
<li>EIC transmission rate stability is improved.</li>
<li>DG HYBRID: It is no longer possible for the unit to send negative P-ref set points to a PV inverter.</li>
<li>Power emulation for AGC 150 with Option S1 is now calculated and shown correctly.</li>
<li>DG HYBRID: Corrected an issue where Emulation PV was not able to start with PV protocol set to OFF.</li>
<li>DG HYBRID: Corrected an issue where Goodwe DT and MT protocols would show negative ACP at values above 32768 W.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.09.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-09-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a1231e1b-6357-43e9-b1d8-1b1548fe61e6</guid>
        <pubDate>2022-02-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.09.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<h3>Corrections:</h3>
<ul>
<li>Logs stored correctly to work after a power cycle.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c7b076e9-95a6-4f26-949e-c2d30a59f9e8</guid>
        <pubDate>2022-02-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.10.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>New features:</h3>
<ul>
<li>Controller types 'Genset Marine' and 'Engine Drive Marine' added.</li>
<li>DG HYBRID: Growatt CP100-CP250 &amp; Growatt CP500-CP2250 PV protocols added.</li>
<li>DG HYBRID: Growatt Mac, Max &amp; Mid series PV protocol added.</li>
<li>RMI Water temperature extended ranges.</li>
<li>DG HYBRID: SMA Data Manager PV protocol added.</li>
<li>Support of Perkins Stage V 120xJ (SU, VM) EIC protocol added.</li>
<li>Support of Deutz EMR5 Stage V EIC protocol added.</li>
<li>Activate/deactivate spinning reserve via M-Logic added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>DG HYBRID: Renamed "Growatt" PV protocol to "Growatt UE-series".</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>DG HYBRID: Q share and DG cosphi limits now works correctly compared to the cosphi of the DG.</li>
<li>Increased measurement inaccuracy at changing frequency could be seen infrequently.</li>
<li>AMF Overlap is now working when modeshift is used with two or more MAINS units in power management.</li>
<li>Numbers of view pages is updated correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0cb35681-7ff9-4355-b057-436b7545b39b</guid>
        <pubDate>2022-03-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.10.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>Corrections:</h3>
<ul>
<li>EIC autoviews is not deleted doing power up.</li>
<li>EIC Deutz EMR Stage V: DEF level is shown and SPN5246 is mapped to m-logic eic derate active.</li>
<li>MARINE EDG: GB stays closed in SEMI mode even though the STOP button is pressed.</li>
<li>Translation issue seen when loading multiple languages is corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.10.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">57a132bc-337d-418f-8231-71aa99318709</guid>
        <pubDate>2022-04-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.10.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>Corrections:</h3>
<ul>
<li>GOV output was sometimes raising to 100% when GB was closed with static sync. This has been fixed.</li>
<li>Deutz EMR Stage V stop telegram corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.10.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6af54495-3ac4-41a0-8f28-5781073cb269</guid>
        <pubDate>2022-06-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.10.3</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>Corrections:</h3>
<ul>
<li>Engine Drive Marine, Marine DG ISLAND: Remote Start and Remote Stop working.</li>
<li>MARINE: Status text updates.</li>
<li>MARINE: TEST function now stops the engine when TEST is finalised.</li>
<li>MARINE: Idle run stops engine correct when using Low speed or timer.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.10.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-10-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">05194d11-289d-47f8-9414-8969d7cbae98</guid>
        <pubDate>2022-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.10.4</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>Corrections:</h3>
<ul>
<li>Corrected an issue where two or more DGs could end up with the same priority.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">71745e20-a28b-454c-b355-c51083397f09</guid>
        <pubDate>2022-07-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.11.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>New features:</h3>
<ul>
<li>JC15D Weifu alarm texts added to DM1 log.</li>
<li>Added support of JC15D WYS EIC protocol.</li>
<li>Added support of JC190 EIC protocol.</li>
<li>Added support of Bosch EDC17CV54TMTL EIC protocol.</li>
<li>Added configurable TSC1 transmission rate and checksum/counter for Generic J1939.</li>
<li>Added support of Xichai EIC protocol.</li>
<li>Enable/disable alarm ack. via J1939 (DM11).</li>
<li>Added support of Kubota EIC protocol.</li>
<li>Extended RMI 20 Points in multi-inputs.</li>
<li>Extended mA 17 Points in multi-inputs.</li>
<li>Hybrid Supervision view on controller display added.</li>
<li>Parameter to block nominal settings changed.</li>
<li>Extended EIC wait to start (preheat) support. Introduced M-Logic command to inhibit wait to start.</li>
<li>View line: Added kW per phase (L1, L2, L3).</li>
<li>View line: Added kW per phase in percent (L1, L2, L3).</li>
<li>View line: Added Power factor per phase (L1, L2, L3).</li>
<li>EIC: Added support of Scania EMS2 S8 HC Evaporation Status in M-logic and view.</li>
<li>View line: Added Charge Alternator Voltage - D plus voltage.</li>
<li>Automatic speed detection view line.</li>
<li>Automatic oil pressure view line.</li>
<li>Automatic water temperature view line.</li>
<li>Automatic fuel level detection view line.</li>
<li>Multi-input view lines change text with RMI selected.</li>
<li>Added RMI Custom to multi-input input type.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>J1939 protocol "Jichai" renamed to "JC15D Weifu".</li>
<li>FPT/Iveco Stage V updated.</li>
<li>Default views updated.</li>
<li>Default values for multi-input.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>N + X ON/OFF via digital input or M-Logic corrected.</li>
<li>Busbar measurement working correct in single and split phase with BB set to 3W3.</li>
<li>A genset will now charge a battery with the correct amount during negative PMS set points.</li>
<li>A genset will now calculate the correct power reference if a battery operating as a energy source is charging from excess PV power.</li>
<li>A running DG with its GB closed could react to invalid power management data when changing from a single DG application to a standard application.</li>
<li>DVC 550/D550: Stator current limitation events in M-Logic did not work.</li>
<li>A mains could issue a start signal to DGs based on invalid power management data when a BTB was power cycled.</li>
<li>AOP-2 button emulation from USW-3 working.</li>
<li>Fault in PDB. Alarm Relay ND and NE text swap. I/O setup is wrong; parameter is correct.</li>
<li>External generator breaker configuration on DGs corrected so GB relays are configurable.</li>
<li>Configuration of running detection timer is now working from display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ff8f0e5b-7b8b-461c-8b62-fc54d1b4784d</guid>
        <pubDate>2022-09-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.12.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>New features:</h3>
<ul>
<li>New device type ASC 150 Storage added.</li>
<li>External controlled MB available on stand-alone (option S1) generator variants (LAND, MARINE, HYBRID).</li>
<li>CAN B protocol changed with M-Logic to PM and CanShare.</li>
<li>Oneshot logic in M-Logic.</li>
<li>Current alarms for 4th CT measurement added. Menu 7420 and 7430.</li>
<li>CBE re-run failure alarm added. Menu 2230.</li>
<li>Text tree structure in USW translation added.</li>
<li>List with common names for digital inputs.</li>
<li>EIC: Added FPT Stage V SPN/FMI fault codes.</li>
<li>EIC: Added support of KWG ISO5 isolation monitor.</li>
<li>EIC: Added support of QiYao Gas.</li>
<li>EIC: Added support of Doosan stage V protocol.</li>
<li>HYBRID: Added support for Thea PV protocol.</li>
<li>HYBRID: Added support for Deye SUN 30-50K-G03 PV protocol (Unicast only).</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>I/O status added to trending in USW.</li>
<li>Busbar block handling in PMS now allowed to let the system (DG, MAINS etc) run even though any breaker has position failure.</li>
<li>EIC: Scania S8 is now showing regeneration active symbol when manual regeneration is active.</li>
<li>Reduced number of languages to 10.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>#7804 DAVR bias range now works correctly for DVC 550 and D550 DAVRs.</li>
<li>Update of modes on all controllers in a PMS application has been made more robust.</li>
<li>PMS island load sharing would not work correctly when #9030 Scaling was set to something other than default. This has been corrected. PMS asymmetrical load sharing in island also corrected when using a different scaling than default.</li>
<li>In rare cases connected DGs could trip and stop, when units disconnected from PM reconnects.</li>
<li>Diagnostics timer (#6701) is now working.</li>
<li>Channel numbers 7720+7730+7731 in USW aligned with channel numbers in display, so all is 7721+7731+7732 to avoid confusion.</li>
<li>CBE re-run no longer closes generator breaker directly on black busbar with cooldown control set to excitation ON.</li>
<li>Static synchronising works in 3W3 coupling.</li>
<li>Shutdown override did not work correctly when the failclass of an alarm was set to GB trip, GB trip + stop or shutdown. This has been fixed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.12.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-12-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d313e51b-fe1b-4de3-822f-23f35fe4a1c0</guid>
        <pubDate>2022-09-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.12.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>Corrections:</h3>
<ul>
<li>Modbus broadcast telegrams now works again when communicating with multiple PV inverters on the DGHYBRID controller.</li>
<li>Corrected issue where an external Modbus RTU master sending telegrams into a RTU port also configured as a master on the AGC150 DGHYBRID controller could cause a restart.</li>
<li>Corrected the Modbus addresses used for P/Q ref. and ACP/ACQ reading for the SMA Data Manager PV protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8a519e16-7a6a-4e27-9ecd-67b4e8261d61</guid>
        <pubDate>2022-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.13.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.26.0</p>
<h3>New features:</h3>
<p>1- New device type AGC 150 ATS added.<br />2- Support for DEIF DVC 350.<br />3- Automatic adblue refill and a generic fluid refill.<br />4- Automatic adblue refill: System for monitoring and start/stop filling a diesel exhaust fluid tank. <br />5- Fluid fill: System for monitoring and start/stop filling a fluid tank. <br />6- PMS mode update from ASC supported.<br />7- Added average for multi-input and MPU on Modbus and display.<br />8- New parameter #6234 GB reclose attempts added.<br />9- Support for M-Logic shortcuts via shortcut menu.<br />10- Five new LED lamp view lines. <br />11- Added shortcut for engine regeneration.<br />12- Added shortcut for ECU diagnose.<br />13- Virtual event toggles when using Modbus. Created new virtual switch event that stays high when put high in Modbus and M-Logic. <br />14- EIC: Added support of Jichai JC15T JG protocol.<br />15- EIC: Added support of Cummins CM2850.<br />16- EIC: Added support of Cummins CM2350.<br />17- EIC: Added support of Cummins CM2880.<br />18- EIC: Added support of Weichai E6.<br />19- HYBRID: Support for INVT XG series PV protocol added.<br />20- HYBRID: Support for Matter Energy PV protocol added.<br />21- HYBRID: Support for external MB operation added to DG HYBRID (option S1) and ASC 150 added. Ext. MB feedback can also now be set through M-Logic.</p>
<h3>Changes:</h3>
<p>1- The low speed digital input and idle start/stop timers can now be used together.<br />2- Tier 4 icons view now display a frame where icons will be shown.<br />3- Changed overload alarm 5 (1490) to low load alarm. <br />4- In CANshare mode, ID and total number of gensets now shown on lower tiny line in measure views.<br />5- The default application configuration name has been updated.<br />6- Gov renamed to speed control in menu structure.<br />7- Common names in digital inputs (from 1.12.0) used in menu system on display.</p>
<h3>Corrections:</h3>
<p>1- PID force min/max is now working when offset is used.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf86dfd4-2aab-4717-8b0c-bd7d145008fc</guid>
        <pubDate>2022-11-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.14.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.27.0</p>
<h3>New features:</h3>
<ul>
<li>ASC 150 Storage, now with power management support.</li>
<li>AGC 150 DG Easy connect compatibility with ASC 150 Storage.</li>
<li>Added GOV and AVR outputs to trending.</li>
<li>Inverter and busbar V/f measurements from inverter communication supported on all protocols on ASC 150.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Updated Schneider CL 30/33/50/60 PV protocol to only read 6 DC string current values to be compatible with the newest Schneider firmware.</li>
<li>Configurable averaging of AC measurements for readout on display and Modbus in menu 9260.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected that top viewline was flickering when external power setpoint is active. This is also present when the system is on power management.</li>
<li>BTB dividing sections sequence is now working correctly in AMF situations.</li>
<li>Corrected issue with ext comm errors always high, when rs485 port is configured as master.</li>
<li>CANShare initialisation no longer requires a power cycle to act correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">91c66e68-017e-44a5-8cac-88a4fbb7e868</guid>
        <pubDate>2023-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.15.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>New features:</h3>
<ul>
<li>New device type ASC 150 Solar added, supporting both single controller and PMS applications.</li>
<li>Added a pop-up before changing controller type to inform the user that everything is being reset.</li>
<li>GENSET: Added I/O setup menu for configuring internal and external I/O (CIO), including multi inputs and CIO-308 from display.</li>
<li>HYBRID: Support for SolarEdge PPC PV protocol added.</li>
<li>STORAGE: Support for DEIF MIB8000 power meter added.</li>
<li>STORAGE: Support for Eastron Smart X96 power meter added.</li>
<li>STORAGE: Support for EPC Power PCS protocol added.</li>
<li>STORAGE: Added Jinko PCS protocol.</li>
<li>STORAGE: Parameter 2810 added to the ASC-4 Battery. This can be used to configure a timeout period after the last transmitted heartbeat signal before the PCS activates an error (only for supported ESS protocols).</li>
<li>STORAGE: Parameters 2805 &amp; 2806 have been added to support a user-adjustable offset to the droop curves used for delta frequency and delta voltage calculation when a genset or mains is connected.</li>
<li>STORAGE: When the S10 option is disabled and a user tries to change the controller type to ASC 150 storage, a pop-up is shown on the display to tell the user that the S10 option is disabled.</li>
<li>STORAGE: Added BMSer Technology BMS protocol.</li>
<li>STORAGE: Added Narada w Ctrl BMS protocol.</li>
<li>STORAGE: Support for Dynapower CPS-1500 PCS protocol added.</li>
<li>EIC: Added FPT Stage V Turbo heat protection M-Logic event.</li>
<li>EIC: Added Scania S8 safe regeneration signal M-Logic output</li>
<li>EIC: Added safe regeneration status M-Logic event.</li>
<li>EIC: Added support of Caterpillar ADEM6.</li>
<li>EIC: Updated Iveco Stage V with new alarms, M-Logic events and symbol handling.</li>
<li>EIC: Added a new view to check the status of a regeneration request from the ECU. Added new M-Logic events to Deutz EMR5 Stage V.</li>
<li>EIC: Added new view for engine icons. Added new icons for FPT Stage V.</li>
<li>STORAGE: Support for Ausar MAE version A04. ESS protocol added.</li>
<li>STORAGE: Added new M-Logic output and event to give the user the option to manually activate boost charging in supported systems.</li>
<li>STORAGE: Parameters 17201, 17202 and 17203 have been added to set a PDS spinning reserve value. This sets the percentage of the produced PDS power which should be reserved locally as extra available battery discharge capacity.</li>
<li>HYBRID: Support for using M-Logic for handling external GB, ESB and PVB added.</li>
<li>PLC-controlled PMS. When in auto mode and this mode is activated using M-Logic, a user can control the controller using a PLC (for example, digital inputs).</li>
<li>TEM analog transducer output added in menu 5750.</li>
<li>STORAGE: Added SICON PCS protocol.</li>
<li>EIC: Added support of Kohler KDI 3404 Stage V.</li>
<li>Added a new small text version of the synchroniser view.</li>
<li>STORAGE: Added support for Gold BMS protocol.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>HYBRID: Updated Huawei V.3 PV Protocol to send a start/stop command to the inverter based on the controller status.</li>
<li>Improved texts to PID regulator: Kp (Gain), Ti (Stability), Td (Derivative).</li>
<li>M-Logic event for "CBE excitation start level (rpm) reached" added.</li>
<li>M-Logic event for Load Dependent Start/Stop 2 ON/OFF status added.</li>
<li>M-Logic command for Load Dependent Start/Stop 2 ON/OFF control added.</li>
<li>Averaged P and Q (introduced in version 1.14.0) can now be used for load sharing (menu 9267).</li>
<li>STORAGE: Sungrow LC100 Utility LFP and STxxxCP50-HV ESS protocols will now use delta frequency and voltage regulation when operating in VSG on-grid mode.</li>
<li>Translations: Two languages were removed, and texts per translation (languages) were increased.</li>
<li>EIC: Added a new text on the Aftertreatment viewline when the ECU is not connected or responding.</li>
<li>EIC: Inhibit DM1 lamp alarm if engine is not running and no valid SPN is available.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>STORAGE: Corrected the issue where multiple batteries operating in island with PVs make the PVs overproduce power compared to what the batteries were asked to charge.</li>
<li>The power ramp module initiates its ramp faster.</li>
<li>AGC 150 renamed text "EIC configuration" to "ECU configuration".</li>
<li>AGC 150 EIC configuration moved from GOVC to Engine subfolder in USW and display.</li>
<li>MAINS unit power measured with open MB no longer added to available power in DG.</li>
<li>Hz/V OK alarm timer (4560) no longer started in CBE, when cooldown is active, and excitation is removed.</li>
<li>STORAGE: Corrected Modbus issue with DEIF MIC 4000 power meter protocol.</li>
<li>EIC: LiveLink is now working when used with PSI.</li>
<li>STORAGE: Corrected issue where parameter 2741 for delaying regulation after start signal did not work for charging set points.</li>
<li>Change of breaker feedback is remembered after a power cycle.</li>
<li>Corrected issue where specific PV spinning reserve values in a plant with a battery and DGs could cause genset start/stop looping.</li>
<li>Corrected issues where PV spinning reserve values in a plant with a battery, PV, Mains and DGs would not start and stop the gensets at the correct available power.</li>
<li>STORAGE: ASC 150 Storage was able to close the MB with an unsupported application alarm active.</li>
<li>Busbar emulation improved.</li>
<li>STORAGE: Corrected issue where a battery still would try to charge fully from a PV which was deloading to stop.</li>
<li>Mains failure hysteresis is now respected if one of the OK timers is running at the same time as the OK condition is reached.</li>
<li>HYBRID: It is now possible to choose P &amp; Q measurement values from Modbus communication when in emulation.</li>
<li>Measurements P-L2, S-L1, S-L2, S-L3 readout in display scaled correctly.</li>
<li>TB remains closed even though a PV is the only power source connected to the busbar.</li>
<li>STORAGE: Corrected the calculation of frequency set point for ESB sync and MB back sync.</li>
<li>STORAGE: Corrected issue where a battery would stop in a PMS auto application if the internal mode of the ASC was set to "No dispatch" instead of only offloading when other voltage sources were connected to the busbar.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.15.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-15-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ccb463b5-b5c4-4539-8ac4-3e1427852666</guid>
        <pubDate>2023-04-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.15.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>Corrections:</h3>
<ul>
<li>The breaker ext. tripped alarm is no longer triggered when reconfiguring a no breaker application to an application with a breaker.</li>
<li>STORAGE: Corrected issue where a Sinexcel PCS without VSG would switch from V/f mode to P/Q mode during ESB synchronisation resulting in sync failure.</li>
<li>MAINS: Corrected issue where PV did not produce the correct Q based on its capability curve and P/Q cap. limit in PMS applications.</li>
<li>STORAGE/SOLAR: Using M-Logic for external PVB/ESB feedback is now possible when emulation is active.</li>
<li>Power meters in application supervision are no longer shown on external BTB.</li>
<li>Multi-input scaling issue on custom curve. It now shows the correct value compared to the curve it should follow.</li>
<li>During a transfer of ground relay, a DG that was not suited for closing its ground relay, could briefly close it and then quickly open it again. This has been fixed.</li>
<li>STORAGE/SOLAR: Incorrect handling of digital input functions, "Remote start/stop" and "Remote PVB/ESB on/off" corrected.</li>
<li>When the energy counter "kvarh" was on a viewline on the controller, the corresponding viewlines on other pages showed the last variable incorrectly. With this the costumer got the wrong information on the controller. This has been fixed.</li>
<li>DG HYBRID: PV is no longer prevented from starting in applications where no GB is configured, as long as there is voltage on the busbar.</li>
<li>DG: Fixed menu for multi-input 20 failing to display viewing of curve set points.</li>
<li>Engine Drive/Engine Drive Marine: Support of PWM output using PID1 (engine speed).</li>
<li>DVC "controls OFF" only sent few initial data after loss of communication.</li>
<li>Power ramp 1 automatic shift to power ramp 2 working correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fdc2b776-32df-45ed-934b-41387b3e0a26</guid>
        <pubDate>2023-05-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.16.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>New features:</h3>
<ul>
<li>Added new device type, AGC 150 DG PMS lite.</li>
<li>EIC: Added support of Scania S8 Industrial.</li>
<li>EIC: Added support of ANGLE.</li>
<li>EIC: Added support of Jing Guan.</li>
<li>EIC: Added support of JCB 430/448 Stage V.</li>
<li>EIC: Added M-Logic outputs to inhibit DM1 protection, yellow, red and malfunction lamp alarms.</li>
<li>EIC: Added VTAs on EIC malfunction and protection alarms.</li>
<li>EIC: Added After treatment DPF Time since Last Regeneration to the display and Modbus.</li>
<li>SOLAR: Added support for Ingeteam 3Play ABS PV protocol.</li>
<li>SOLAR: Added support for Sofar -G3 PV protocol.</li>
<li>STORAGE: Added support for CATL liquid cooled BMS protocol.</li>
<li>STORAGE: Added support for Megarevo MPS protocol.</li>
<li>STORAGE: Added support for Polarium BMS protocol.</li>
<li>STORAGE: Added support for GTZKNE FX34 BMS protocol.</li>
<li>STORAGE: Added support for Yingbo PCS protocol.</li>
<li>STORAGE: Added support for Oztek OZpcs-RS40 PCS protocol.</li>
<li>STORAGE: Added support for SinExcel PWS2 30K PCS protocol.</li>
<li>STORAGE: Added Battery SOC active threshold levels in M-Logic.</li>
<li>MAINS: Added negative and zero sequence alarms.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>M-Logic and digital input function to allow safe regeneration.</li>
<li>Sinexcel PDS has been updated to read the power of a maximum of 8 DC strings.</li>
<li>EIC: FPT Stage V Low oil pressure alarm can only be triggered while running. Added new M-Logic event for DEF warnings.</li>
<li>EIC: Updated DM1 and DM2 headline log texts.</li>
<li>EIC: Stage V: Added the four AT regeneration states to the existing view-line.</li>
<li>EIC: Added auto acknowledge feature for engine comms alarm, channel 7570.</li>
<li>SOLAR: Changed the name of existing Ingeteam 3Play PV protocol to "Ingeteam 3Play ABI".</li>
<li>STORAGE: Changed the name of the existing CATL BMS protocol to "CATL air cooled BMS".</li>
<li>STORAGE: Changed the Atess protocol to only send start/stop commands when the run state has changed.</li>
<li>STORAGE: Changed the name of the existing SinExcel ESS protocol to "SinExcel PWS1".</li>
<li>Updated the alarm list to include alarm value, set point and fail class.</li>
<li>Added enable to the 3 inputs in the General PIDs (GPID) in the M-Logic commands.</li>
<li>Reference Set point, Min, Max and Offset added to all four General PIDs (GPIDs).</li>
<li>STORAGE: Added support for Yingbo VSG mode.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Corrected issue where PV did not produce the correct Q to meet the requested grid PF, when the plant operates with a voltage-based droop and the mains voltage changes.</li>
<li>STORAGE: Fixed Jinko protocol scaling of PQ and current limits. Start/stop cmd issue also fixed.</li>
<li>DG HYBRID/STORAGE/SOLAR: When using ext. GB/ESB/PVB and MB, if the functions of the default digital inputs for GB/PVB/ESB and MB feedbacks are set to "Not used", they do not influence the breaker position feedbacks.</li>
<li>Corrected issue where service view timers froze in certain circumstances.</li>
<li>Corrected issue where output 14, output 16 and output 18 (when the device is an AGC 150 ATS) would reset after a power cycle, when the breakers (MB, GB, BTB) are continuous breakers.</li>
<li>Added active/disable feature for Easy connect in the output tab in M-Logic.</li>
<li>STORAGE: Corrected issue where in a PMS plant with PV charging enabled and the PV running with Instant P-Max enabled and set to no sensor, changing the SOC from a value less than SOC max to a value above it, would lead to the battery discharging.</li>
<li>STORAGE: Corrected issue where, when optimal DG load is enabled the battery would not charge from the PV even though the PV was not fully loaded.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e68310f2-1845-4516-b996-39262821f40f</guid>
        <pubDate>2023-05-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.16.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>Corrections:</h3>
<ul>
<li>EIC: Aftertreatment 1 DPF Time since Last Active Regeneration (SPN 3721) has been corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">23257153-36be-4014-b5b5-efc4fbd420fd</guid>
        <pubDate>2023-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.17.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.0</p>
<h3>New features</h3>
<ul>
<li>Multi-start switch to minimum number to run right after first GB closes via configuration in menu 8360.</li>
<li>LD stop without delay available via configuration in menu 8350.</li>
<li>SOLAR/DGHYBRID: Added new Modbus TCP/IP extended setup of the ASC 150 Solar and AGC 150 DG HYRBID.</li>
<li>SOLAR/STORAGE: Added open PMS functionality.</li>
<li>SOLAR: Added support for Power One PV protocol.</li>
<li>STORAGE: Added Eastron SDM630CMT powermeter protocol.</li>
<li>Added new Modbus area for alarm list monitoring.</li>
<li>STORAGE: Added parameters 17161 and 17163. If the parameters are enabled, they will overwrite the value of the maximum charge voltage and minimum discharge voltage read from the BMS.</li>
<li>SOLAR/DGHYBRID: Added Solis logger NISE PV protocol.</li>
<li>Added option to ignore certain SPN rules from the USW.</li>
<li>DG/PMS Lite: Added supervision view-line for DG and PMS Lite.</li>
<li>SOLAR/DGHYBRID: Added Kehua SPI PV protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>SOLAR: Fixed Deye PV protocol issue.</li>
<li>STORAGE: Added max, min and avg. module temperature read-out for the Polarium BMS.</li>
<li>SOLAR: An ASC 150 SOLAR with the Premium option enabled now supports up to 32 PV inverters when using Modbus TCP/IP.</li>
<li>STORAGE: Changed the status reading of the Ausar MAE v4 ESS protocol to only cause a shutdown at critical faults and no longer minor faults.</li>
<li>STORAGE: The Ausar MAE v4 ESS protocol now supports the charging mode for low ripple current, which is turned on by the custom input to ESS in M-Logic.</li>
<li>Manual PMS priority update via digital input or M-Logic only occurs on one DG within 10 seconds.</li>
<li>SOLAR/STORAGE: Changed name of MTR protocol from MTR-3 to MTR-3/4.</li>
<li>STORAGE: RCCR inputs and outputs can now operate with negative P set points.</li>
<li>DG/PMS Lite: Updated the function list for digital outputs to include controller modes.</li>
<li>Possible to have special descriptions of specific SPN/FMI combinations for Volvo Penta EMS2 and EMS 2.4.</li>
<li>Possible to have a second ECU for Volvo Penta EMS2 and EMS 2.4.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>STORAGE: Fixed Yingbo Droop U/F protocol issue.</li>
<li>STORAGE: Corrected scaling issue with read current values from the GOLD BMS protocol.</li>
<li>HYBRID/SOLAR: Fixed broadcast write Modbus message for reactive power (Q) for the Matter PV protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.17.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-17-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c6105670-2ac0-4d22-9045-2171246fc9cc</guid>
        <pubDate>2023-07-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.17.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.0</p>
<h3>Corrections</h3>
<ul>
<li>Measure viewline 5 working again.</li>
<li>Battery log is now correctly updated when the relay output of the battery test function is set to 'limits'.</li>
<li>The load shedding and adding timers were not working as a time hysteresis. This has been fixed.</li>
<li>PMS lite: The available power alarm (menu 8540) was calculated incorrectly. This has been fixed.</li>
<li>PMS lite: The ID not available alarm (menu 8511) would be activated when changing from a manually chosen ID to a different but free ID. This has been fixed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.17.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-17-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">02dec60f-6ab1-498e-8275-b16fc5a032de</guid>
        <pubDate>2023-09-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.17.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.1</p>
<h3>Corrections</h3>
<p>• SOLAR/DGHYBRID: Corrected an issue where the extended Modbus TCP/IP, would use the control ID to initialise SunSpec, instead of the monitoring ID.<br />• SOLAR/DGHYBRID: Fixed an issue where a multiple write telegram together with only one monitoring telegram, would only send out the monitoring telegram.<br />• Fixed an issue where the display LED lamps would flash faster during breaker synchronisation.<br />• In a LTO multi-start setup, a number of multi-start gensets did not always start to synchronise at the same time. This has been fixed. PM compatibility version raised.<br />• Status text 'NOT IN MAN or SEMI' no longer shown in AUTO. V0108 activated.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">004c14db-c995-4aa8-afbb-fa2bf8426d31</guid>
        <pubDate>2023-12-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.18.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.33.0</p>
<h3>New features</h3>
<ul>
<li>GENSET: Fuel optimisation has been updated to support applications including PV and battery.</li>
<li>GENSET: SDU available for genset land (DG).</li>
<li>TDU support added. Requires TDU version 1.4.1.0 or higher. Supports genset land, mains, BTB, solar and storage.</li>
<li>Added new M-Logic and DI input commands for simulating keyboard buttons digitally.</li>
<li>M-Logic: Added M-Logic event counters to the counters tab. This includes: No timer, timer that resets the counters, and timer that resets each individual count per counter.</li>
<li>M-Logic: Added events for detecting when a button on the display has been pushed.</li>
<li>M-Logic: Added output evaluation to Modbus.</li>
<li>Added SPN 92, 512, and 513 to PID1 input and reference (Engine drive, Engine drive marine and DG marine). The SPNs are also added to delta alarm inputs.</li>
<li>Added support for the AGC 150 DG to control a Mainspring linear generator package.</li>
<li>Added idle run interrupt via start/stop in SEMI-AUTO for genset land, genset hybrid, genset marine, genset PMS lite, engine drive and engine drive marine.</li>
<li>Added 3 new RMI custom sensors for multi-inputs.</li>
<li>Added default sensor curves in I/O configuration.</li>
<li>ATS: Extended with new features, such as support of gensets and ATS breaker (2/3 positions).</li>
<li>EIC: Added support for Iveco Stage V NEF67.</li>
<li>EIC: Added support for Cummins CM2358.</li>
<li>SOLAR/DGHYBRID: Added support for Canadian CSI 3PH</li>
<li>SOLAR: Added support for Seven Sensor 3S weather station protocol.</li>
<li>SOLAR: Added support for Seven Sensor 3S-TP GHI-Thermopile Pyranometer Weather station protocol.</li>
<li>STORAGE: Added support for HoyCore HC01CUBE BMS protocol.</li>
<li>STORAGE: Added support for Ningbo Golden Shield BMS protocol</li>
<li>STORAGE: Added support for Pixii PowerShaper ESS protocol.</li>
<li>STORAGE: Added support for Kehua BCS-B-HUD Series protocol.</li>
<li>STORAGE: Added support for Sungrow Powerstack STxxxxkWh 250kW ESS protocol</li>
<li>STORAGE: Added support for Delta EPCS 1200/1500/1725 ESS protocol.</li>
<li>STORAGE: Added support for Sungrow LC200 ESS protocol.</li>
<li>STORAGE: Added support for SinExcel 30P PCS/PDS protocol.</li>
<li>STORAGE: Added new option in the drop-down menu for the Dynapower MPS-125. The functionality of the Dynapower CPS-1500 and the Dynapower MPS-125 is the same. </li>
<li>STORAGE: Added support for Northvolt VMS ESS protocol. </li>
<li>STORAGE: Added support for a battery to act as the isochronous source in grid-forming mode together with gensets in PMS.</li>
<li>STORAGE: Added support for Huasu BMS protocol. The TCPIP port number has been updated so it is possible to change the port number on a BMS, ESS and PDS. </li>
<li>STORAGE: Added support for HagalOcean PD-003V2 BMS protocol.</li>
<li>STORAGE: Added support for Sunwoda Main BCMU protocol.</li>
<li>STORAGE: Added support for Sunwoda BCMU protocol.</li>
<li>STORAGE: Added support for KGooer BMS protocol.</li>
<li>STORAGE/SOLAR: Added support for using CAT EMCP 4 controllers directly as power meter.</li>
<li>STORAGE/SOLAR: Updated openPMS and single controller plants to support deloading of external gensets in island applications, when the start/stop digital output functionality is used.</li>
<li>STORAGE/SOLAR: PV taking maximum load. Accept PV to increase the power and stop genset, even if loads are bigger than BESS nominal size.</li>
<li>STORAGE/SOLAR: Added parameters 2671 and 2672 (P ref. const. gain &amp; P ref. dyn. gain), which allows the user to add a local constant or dynamic gain to the power reference sent to the inverter.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Changed alarm list text from "Bool eval" to "Val" and values "0" / "1" to "low" / "high".</li>
<li>STORAGE: Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.</li>
<li>EIC: Added GTACP (0xFE05, SPN2452/2460) to Caterpillar generic and Perkins generic.</li>
<li>SOLAR/DGHYBRID: Changed control registers for Power One PV protocol.</li>
<li>DG: Digital inputs 47, 48, 49 and 50 are now always visible in the I/O setup menu.</li>
<li>Option S1 controllers can now be changed to the following controller types from the display: Standalone DG, Engine drive, ATS and Remote display.</li>
<li>The shutdown override inhibit is now configurable for the following alarms: #1130 I&gt;&gt; 1, #3490 Emergency STOP, #4510 Overspeed 1, #4520 Overspeed 2 and #7600 EIC overspeed.</li>
<li>STORAGE: Updated the Dynapower CPS/MPS ESS protocol to always be in off-grid mode if parameter 2801 is enabled. Also added droop curve adjustments to reach requested off-grid power set points.</li>
<li>The spinning reserve stop hysteresis is now calculated based on the nominal power on busbar after next DG to stop.</li>
<li>HYBRID: Internal AC, P, Q and S power values averaged for the display and Modbus. Can be used for plant logic by selection in menu 7021.</li>
<li>EIC: Added John Deere DPF stages as M-Logic events.</li>
<li>PMS lite control between ISLAND/CanB ON and SingleDg with Mains/CanB OFF added via I/O and M-Logic.</li>
<li>PMS Lite: Added genset DUTY in AUTO.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>PMS priority update in 32 DG applications now working correctly. </li>
<li>Even if the DAVR controls setting was OFF, connecting to a Nidec D550 without the S4 option would generate an 'Illegal DAVR' alarm. This has been fixed.</li>
<li>The start sequence could not be cancelled between start attempts in SEMI-AUTO. This has been fixed.</li>
<li>AGC 150 Remote display experienced occasional communication loss when it was in sync screen. This has been fixed.</li>
<li>SOLAR/STORAGE: Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue.</li>
<li>SOLAR/DGHYBRID: Inverted the reactive power set point in the Sofar G3 PV protocol.</li>
<li>Using a multi-input as an external reference for regulation no longer needs a power cycle of the controller to work.</li>
<li>If a DG in PMS has an "missing all units" alarm active, it will now shutdown if its auto start signal is deactivated.</li>
<li>STORAGE: Scaling of P/Q reference and charge/discharge capacity corrected in the Matter Energy PCS protocol.</li>
<li>SOLAR/STORAGE: Fixed an issue where it was not possible to switch to application drawing 4 through Modbus Or M-Logic.</li>
<li>Peak shaving working again. Compromised in version 1.17.0.</li>
<li>Alarms with the shutdown override inhibit are now shown in the display and recorded in the alarm log if the alarm becomes active, but the fail class is still inhibited.</li>
<li>STORAGE: VSG mode changed for Sungrow LC100. Now always send, for example, F=50 and U=400, and only use P and Q set point whether the PCS is running alone or paralleling with other sources.</li>
<li>Power capacity is now requested correctly in an AMF application to start the required number of DGs and close the tie breaker (TB).</li>
<li>STORAGE: VSG updated for Sungrow LC100, LC200, Powerstack and STXXXCP-50HP: P and Q set points are used whether the PCS is running alone or paralleling with other sources.</li>
<li>STORAGE: Updated the Danfoss Vacon NXP ESS protocol, so a sync of either ESB or MB is possible.</li>
<li>SOLAR/STORAGE: Fixed scaling of the ESS AC measurements in emulation when AC scales other than 100-25000 V are used and the ESB is open.</li>
<li>Auto calculation of multi-starts with fuel optimisation is now working before the TB is closed.</li>
<li>STORAGE: Corrected the start sequence of the Sicon PCS to only send a start command once.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.18.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-18-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f6be9c40-6b0f-4b67-8a84-a27ae3c157c5</guid>
        <pubDate>2024-02-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.18.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.33.0</p>
<h3>Corrections</h3>
<ul>
<li>STORAGE: Sungrow LC200 Powerstack. PF is now calculated based on ESS P and Q instead of S measurements.<br />• STORAGE: For parameter DCdU (channel 17150), the value has been fixed when either BMS output voltage or PCS input voltage are not valid.<br />• SOLAR: Corrected SMA Datamanager protocol of how NaN values are handled for P and Q. It now shows 0 kW and 0 kvar.<br />• STORAGE: Corrected an issue where a failing write telegram could stop read telegrams from being sent out in the Sungrow Power stack ESS protocol.<br />• STORAGE: Corrected Sungrow Powerstack ESS protocol to not send P mode and only send grid mode when stopped. This is to prevent the BESS initializing status from always showing.<br />• Password 00000 is no longer valid. The lowest value is set to 00001.<br />• A five-digit password is now available on the display.<br />• Change of ID to Run with Run one MAINS during active LTO is now working correctly. <br />• 'Auto detection' as an input for fluid pump has been removed as it was never supported. Output menu for fuel pump also removed as it is no longer used. Fuel pump, DEF pump and fluid pump outputs can now be set up for CIO 208 outputs.<br />• Mains failure hysteresis was overruled in situations where no emergency sources were available. This has been fixed. Furthermore, the precision of the hysteresis calculations has been improved.<br />• STORAGE/SOLAR: Corrected issue where any parameter write could reinitialise the Modbus communication if the power meter interface was set to use RTU port 1 instead of RTU port 2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.18.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-1-8-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d772041f-3c48-408b-ad11-148ebcbc6a05</guid>
        <pubDate>2024-02-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.18.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.33.0</p>
<h3>Corrections:</h3>
<p><br />• It is possible to change time from the service view menu.<br />• BTB deload could block a DG from executing a load-dependent stop sequence.<br />• SOLAR: Fixed an issue where PV protocol for Canadian CSI 3PH did not start correctly.<br />• STORAGE: Sync in AUTO now always work. Bug introduced in version 1.18.0.<br />• STORAGE: Corrected issue where multiple batteries would not share the allowed charging power when peak shaving charging limit is used.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.19.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-19-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">087d5bff-105b-469d-b2a1-24536dab28b3</guid>
        <pubDate>2024-05-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.19.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.34.0</p>
<p><strong>New features</strong><br>1- Added the flexibility to move breaker feedbacks to other internal digital inputs or multi-inputs.<br>2- Added "Any alarm active" digital output function and M-Logic event.<br>3- Added controller name (not translatable) to Modbus.<br>4- GENSET: Added first priority as M-Logic event and configurable output.<br>5- GENSET: Added oil pressure alarm as configurable digital input.<br>6- GENSET: Added water temperature alarm as configurable digital input.<br>7- GENSET: Added Gen Hz/V OK delay expired to configurable output.<br>8- GENSET: Added current transformer scaling for support of CTs with more than one configuration.<br>9- MAINS: Added static synchronisation feature.<br>10- PMS lite: Added digital input and M-Logic command to start all available DGs.<br>11- ATS: Gen/Gen mode, new I/O functions and other improvements.<br>12- EIC: Added EIC Fan speed (SPN 986) as PID output. Added fan speed feedback (SPN 1639/975) as input to PID.<br>13- EIC: Added support of SDEC F20/F45.<br>14- EIC: Added support of Caterpillar with C7.1 AT.<br>15- EIC: Added support of Deutz EMR4 Stage V.<br>16- EIC: Added support of Cummins CM570 Industrial, CM2350 Industrial, CM2880 Industrial, Generic Industrial and PGI.<br>17- EIC: Enable diagnostic available from M-Logic.<br>18- SOLAR: Added new PV protocol for Meteocontrol Bluelog XC.<br>19- SOLAR: Added new M-Logic output "External ESS on PV busbar". This allows an ASC Solar to operate in Fixed Power Mode with an external battery if no other voltage source are connected to the busbar.<br>20- SOLAR: Added new PV protocol for Solax X3-FORTH/X3-MEGA G2.<br>21- SOLAR: Added new PV protocol for Solax MIC-G2/Pro-G2.<br>22- SOLAR: Added new PV protocol for Sineng SP320K Series.<br>23- STORAGE: Added support for hybrid-specific general purpose PIDs which can be used to regulate either a frequency or voltage offset on top of the normal reference.<br>24- STORAGE: Added a new parameter 2663 "Uf origin" config. This gives the user access to set when U and f ref. origin parameters in 2661 and 2662 are active.<br>25- STORAGE: Added new parameter 7086 "Inhibit MB/TB open". This allows a PCS (if supported) to delay an opening of an MB, TB or ESB if the grid mode of the PCS is not ready for the switch. This is only for semi and LTO openings, Mains failures will ignore this setting.<br>26- STORAGE: Added support for Lithium Valley BMS protocol.<br>27- STORAGE: Created parameter 15180 "Ext. DG. break. open" to set the breaker open point for ext. DGs. If the last ext. DG is required to stop in an off-grid application, the start/stop digital output is kept high until the battery has deloaded the ext. DG below the breaker open point.<br>28- STORAGE: Added support for Enervenue BMS protocol.<br>29- STORAGE: Added support for Huawei SACU Smartlogger.<br>30- STORAGE: Added new choice for delta alarm parameters to allow use with larger batteries.<br>31- STORAGE: Added support for Alfen BCU.<br>32- STORAGE: Added new ESS protocol for KStar GSE 50-630 PCS.<br>33- STORAGE: Added new BMS protocol for Gotion BMS.<br>34- STORAGE: Added support for BYD Cube Pro BMS.<br>35- STORAGE: Added new ESS protocol for Delta PCS 100HV.<br>36- STORAGE: Added support for Huasu S02/03 BMS.<br>37- STORAGE: Added parameter 8042 to allow the user to select if the PMS isochronous master functionality should also be supported in droop operation or only V/f mode.<br>38- STORAGE: Added support for busbar measurements to be used as inputs or set points in the general purpose PIDs.<br>39- STORAGE: Added parameter 2664 to allow the user to set a custom voltage reference gain compared to the nominal parameter. This is useful for adjusting the voltage for internal transformers of the PCS.&nbsp;<br>40- STORAGE: Added new BMS protocol for BMSer Single Cluster.<br>41- STORAGE: Added new M-Logic line for lowest running ESS ID.<br>42- STORAGE: Added support for Sinosoar SP100H BCU protocol.<br>43- SOLAR/STORAGE: Added support for general purpose PIDs on ASC 150 with the PREMIUM option set.<br>44- SOLAR/STORAGE: Added support for the Acrel ADL power meter protocol.<br>45- SOLAR/STORAGE: Added support for hotel load. Another source drawing power from the system that is not the customer. This is subtracted from nonimal power and added to the power reference.&nbsp;<br>46- SOLAR/STORAGE: Added new power meter protocol for Eastron Smart X96 with digital input support.<br>47- SOLAR/STORAGE: Added configurable power meter. With this it is possible to set up and read activer power, reactive power and up to 4 digital inputs from a power meter via user inputs in the USW.<br>48- SOLAR/STORAGE: Added new power meter protocol for Kohler APM403 genset meter.<br>49- SOLAR/STORAGE: Added support for breaker feedback for DEIF MIC-2 power meter protocol.</p>
<p><strong>Changes</strong><br>1- EIC: Yanmar Stage V: Regeneration request sequence now configurable through the USW. The "Regeneration needed" and "Regeneration active" icons will now display if the states are active in the ECU. The "Regeneration inhibit" command has been inverted as per the specification.<br>2- STORAGE: Updated the sequence of grid mode switching in the Sinexcel PWS1 ESS protocol to always use the VSG modes as intermediate modes, in between the required grid modes to prevent the PCS from stopping.<br>3- GENSET: Extended analogue load share with separate parameter for Qset as DC level at 100 % kvar. New parameter in menu 6393.<br>4- STORAGE: Huasu BMS update: New offset for battery current, max charge current and max discharge current. The old offset is 1600 A. The new offset is 3000 A.<br>5- EIC: Added additional measurements for "Engine knocking" and "Spark-ignition" to Cummins.<br>6- STORAGE: Updated Dynapower CPS and MPS ESS protocols to also enable the anti-islanding register if P/Q mode is forced from M-Logic.<br>7- GENSET/MAINS: The block fail class now also blocks the MB on sequence. It is therefore aligned with how other breakers are handled in regards to the block fail class.<br>8- EIC: Updated Deutz Stage V to support EPA1/2/3 and DEF low level lamp.<br>9- STORAGE: Changed the name of the existing Huasu BMS to Huasu S04 BMS.<br>10- STORAGE: Huasu S04 BMS will no longer open the DC breaker when the BMS state is fault.<br>11- PMS Lite: Genset on DUTY can now also be activated from M-Logic.<br>12- PMS Lite: Genset on DUTY now requires Auto start signal before it is able to run.<br>13- STORAGE: Updated SinExcel PWS1 ESS protocol to use new voltage offset and rated voltage/frequency registers based on ESS software version 1517 and later versions.<br>14- EIC: Updated FPT Stage V/Iveco NEF67.<br>15- EIC: SPN ignore - Icons are not shown if SPN/FMI combination is ignored. But it is possible to get data about the fault in the DM1 log.<br>16- EIC: Kohler KDI3404 - Added Pedal Input Delay events to M-Logic.<br>17- Digital inputs no longer shown in the USW parameter list - only visible in the I/O page.<br>18- GENSET: EIC and DAVR are no longer shown in the USW parameter list - only visible in ECU &amp; DAVR page.<br>19- GENSET: Added new status text and info message making it more visible to the user when the GB open failure alarm is blocking a generator stop.</p>
<p><strong>Corrections</strong><br>1- GENSET: Q analogue load-share with Woodward SPM-D11 via IOM now works correctly.<br>2- SOLAR: Switch from AUTO to SEMI on another device could cause a breaker open and stop in rare cases.<br>3- Remote display: Unit type selection available for all software packages.<br>4- STORAGE: Corrected an issue where an ASC 150 Storage could not start/stop a power management plant running in island operation with start/stop parameter 8021 set to "local".<br>5- ATS: Open in-phase is working with 3-pos ATS breaker.<br>6- GENSET: P(U) droop curve deadband settings was used with a factor 10 too much. This has been corrected.<br>7- MAINS with Ext MB/ATS control working again. Bug introduced in version 1.13.0.<br>8- GENSET: Busbar frequency text was misplaced on supervision view. This has been corrected.<br>9- STORAGE: Corrected issue where the Megarevo MPS ESS protocol would reinitialise the start sequence of the PCS in a loop.<br>10- Fixed readout of CIO thermocouple set point on AGC 150 display.<br>11- SOLAR/STORAGE: If the voltage/frequency measurements were sourced from PV/ESS communication the phase sequence alarm would be activated. This has been corrected.<br>12- SOLAR: Power measurements from TCP/IP PV inverters not summarised unless RTU TX WriteType was set to broadcast. This has been corrected.<br>13- MAINS stand-alone with CAN bus OFF can now close MB after power cycle.<br>14- STORAGE: ESS auto started in OpenPMS when any external DG on BB and not when start signal was given. This has been corrected.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9cbfd81a-309b-45f4-aa6a-c6ab3e87c7da</guid>
        <pubDate>2024-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.20.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p><strong>IMPORTANT</strong>: This software requires USW-3 version 3.60.1 with PDB revision 10688 or higher.</p>
<p><br>PM compatibility: 1.35.0</p>
<p><strong>New features</strong><br>&nbsp; &nbsp;1- Added definite timer for I neutral and I earth fault. Menus 14210, 14220, 14230, and 14240.<br>&nbsp; &nbsp;2- Added selection for measurement type for 4th CT trip. Menu 14200.<br>&nbsp; &nbsp;3- GENSET: Added support for digital load sharing with DeepSea MSC7 in SEMI-AUTO mode.<br>&nbsp; &nbsp;4- GENSET: Added three-phase current transformer inverting.<br>&nbsp; &nbsp;5- EIC: Added support for Baudouin CPCB IV.<br>&nbsp; &nbsp;6- SOLAR: Added new PV protocol for LIVOLTEK SunSpec.<br>&nbsp; &nbsp;7- SOLAR: Added new PV protocol Eachenergy PV. Protocol also supports some Chisage PV inverters.<br>&nbsp; &nbsp;8- STORAGE: Added support for Sungrow LC200 Multi PCS BCU protocol.<br>&nbsp; &nbsp;9- STORAGE: Added new BMS protocol for HuaSu S06.<br>&nbsp; &nbsp;10- STORAGE: Added new parameter 7960 "DEIF Generic Offset". This allows you to select between higher and lower Modbus address spaces for the ESS protocol DEIF Generic.<br>&nbsp; &nbsp;11- STORAGE: Added new "Wait" status for the ESS protocol DEIF Generic. This status guarantees that the ASC controller does not send a start or stop signal over Modbus and triggers the "ESS NOT READY" status text in display.<br>&nbsp; &nbsp;12- STORAGE: Added new ESS protocol for Enjoy PCS.<br>&nbsp; &nbsp;13- STORAGE: Added new BMS protocol for EVE MBMU BMS.<br>&nbsp; &nbsp;14- STORAGE: Added ground relay PMS application. This feature allows automatic control of the grounding point between gensets and batteries in a greenfield plant.<br>&nbsp; &nbsp;15- STORAGE: Added new parameter 8152 "Gnd priority". This parameter controls whether gensets or batteries should have an active ground relay function when their nominal sizes are the same.<br>&nbsp; &nbsp;16- GENSET: Added new parameter 8154 "Gnd priority". This parameter controls whether gensets or batteries should have an active ground relay function when their nominal sizes are the same.<br>&nbsp; &nbsp;17- STORAGE: Updated the ESS protocol DEIF Generic to be able to write the current status of the ground relay.<br>&nbsp; &nbsp;18- STORAGE: Added new ESS protocol Sungrow LC100 Utility v1.12.</p>
<p><strong>Changes</strong><br>&nbsp; &nbsp;1- GENSET: Changed the stop sequence of the MSE package protocol to use a standby signal when no faults are present in AUTO mode instead of a full stop command.<br>&nbsp; &nbsp;2- Text handling updated to add two more languages to the controller. This requires the new USW-3 for connection.<br>&nbsp; &nbsp;3- EIC: Added M-Logic command flag to give control if preheat to Volvo EMS.<br>&nbsp; &nbsp;4- EIC: Kohler KDI3404. Added support for second ECU.<br>&nbsp; &nbsp;5- ATS: BTB close inhibit is aligned with BTB close failure.</p>
<p><strong>Corrections</strong><br>&nbsp; &nbsp;1- STORAGE: KStar GSE 50-630 PCS protocol can handle the transition from V/f to P/Q mode.<br>&nbsp; &nbsp;2- GENSET: Enter black busbar protection not working as intended in CANshare and PMS lite. This has been fixed.<br>&nbsp; &nbsp;3- SOLAR/STORAGE: Corrected issue where an Open PMS plant would not automatically give an auto start signal when the operation mode was peak shaving mode and the load was above the peak shaving set point.<br>&nbsp; &nbsp;4- MAINS controlled fixed for Imp/Exp with low mains breaker power caused unstable PF in GENSETs. This has been corrected.<br>&nbsp; &nbsp;5- STORAGE: Corrected issue where BMS protocol Ningbo BMS would not connect/disconnect BMS racks.<br>&nbsp; &nbsp;6- PMS lite: Digital output selection via display works again.<br>&nbsp; &nbsp;7- Menu 9100 works correctly in marine variants.<br>&nbsp; &nbsp;8- STORAGE: Fixed issue where Sinosoar SP100H was not able to read 112 registers in 1 telegram. The reactive power feedback and set point direction have also been corrected.&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.20.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-20-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bd78a3de-025d-48b9-81f1-22edd4f7549e</guid>
        <pubDate>2024-09-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.20.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.35.0</p>
<h3>Corrections:</h3>
<ul>
<li>ATS: Fixed an issue where BTB close inhibit could cause the CBs to become stuck in the open state when executing an AUTO operation.</li>
<li>SOLAR/STORAGE: Fixed an issue where M-Logic events for ESB/PVB fail alarms were never active even though the actual alarms were active and not acknowledged.</li>
<li>SOLAR: Fixed incorrect scaling of active and reactive power set points when writing to LIVOLTEK SunSpec PV.</li>
<li>SOLAR: Fixed an issue where the Solax MIC-G2/Pro-G2 PV protocol assumed the plant was ready to operate even though it had failed to unlock some inverters using the password.</li>
<li>ATS:Fixed issue where breaker could close automatically at blackout in application with gensets and parallel not allowed in SEMI.</li>
<li>SOLAR: Fixed an issue with Seven sensor 3S-TP and 3S-IS weather stations, where some addresses and data were missing or changed.</li>
<li>SOLAR: Fixed an issue where SunSpec Generic kept sending WMaxPct/VarMaxPct Enable even when parameter 2783 "P ref. Enable" or parameter 2784 "Q ref. Enable" was disabled.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">18c5aa59-c4e1-44c8-a309-7e88ec02cf33</guid>
        <pubDate>2024-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.21.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p><strong>IMPORTANT: This software requires USW-3 version 3.60.2 with PDB revision 10963 or higher.</strong></p>
<p>PM compatibility: 1.35.1</p>
<h3>New features</h3>
<ul>
<li>GENSET Stand Alone: Manual control of EIC speed added. Controller via digital inputs.</li>
<li>EIC: Added buzzer output for Baudouin CPCB IV.</li>
<li>EIC: Show CAN data on display and Modbus.</li>
<li>EIC: Added support of Caterpillar ADEM5.</li>
<li>BTB: BTB controllers can now be statically synchronised.</li>
<li>STORAGE: Added new BMS protocol for HuaSu Single Cluster.</li>
<li>STORAGE: Added new BCU protocol for BESS Nomad.</li>
<li>STORAGE: Added new parameter 17400 "Maintenance Charge". This allows charging based solely on maximum charge capacity from BMS instead of SOC. This feature can be used to fully charge battery systems when the SOC is not reliable.</li>
<li>STORAGE: Added new parameter 17401 "Charge capacity threshold". This sets a threshold in kW of the maximum charge capacity from the BMS when 17400 "Maintenance Charge" must adhere to stop charging.</li>
<li>STORAGE: Added new Command schedulers: 24 new schedulers that can run on specific days within a specific time period. The schedulers can now run functions such as operation modes with fixed power and reactive power setpoints and more. M-Logic command scheduler events can also be set and used.</li>
<li>STORAGE: Added new M-Logic event set to true if genset load sharing in power management system is currently in reverse power.</li>
<li>STORAGE: Added parameter set minimum genset cosphi in inductive range.</li>
<li>STORAGE: Added M-Logic lines to skip Q-Ramping for batteries.</li>
<li>STORAGE: SinExcel PWS2 30K ESS protocol now supports writing the status of ground relay for STS to open/close PE-N contactor.</li>
<li>SOLAR/STORAGE: Configurable power meter update: Offset for active and reactive power has been added.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>The save rate of some counters has been increased.</li>
<li>GENSET: Changed MSE package protocol to always read SunSpec model 703 with an interval of 5 seconds to prevent any mismatch of feedback between AGC 150 and MSE package.</li>
<li>GENSET Stand Alone: 40 M-Logic lines now available.</li>
<li>GENSET: Nominal set 5 and 6 added in menu 6800 and 6810.</li>
<li>GENSET-MAINS: Averaged P and Q introduced in version 1.14.0 can now be used for regulation and ramping. Use menu 9268.</li>
<li>GENSET-MAINS-BTB: Averaged P, Q and S introduced in version 1.14.0 can now be used for power management. Use menu 9269.</li>
<li>EIC: Implemented Yuchai faultcodes.</li>
<li>EIC: Event log now shows SPN/FMI in display.</li>
<li>EIC: New M-Logic events and AT texts added to John Deere Stage V.</li>
<li>STORAGE: Sinosoar SP100H now stops sending internal BMS telegrams when BMS protocol configured.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where language write fails.</li>
<li>M-Logic commands 'Inh. start button', 'Inh. stop button', 'Inh. GB/TB button' and 'Inh. MB button' can now be read by the TDU. This requires TDU version 1.4.3.0 or later.</li>
<li>GENSET: Soft voltage recovery and I stator limitation now works regardless of the configuration of the DVC 550/D550 and DVC 350.</li>
<li>GENSET: Corrected an issue with calculating the load impact for single DGs in emulation.</li>
<li>MAINS: 'Mains power' measurement in datatracer now properly scaled based on the #9030 Scaling parameter.</li>
<li>GENSET/MAINS/BTB: Fixed issue where emulated load from ASC variants was not added correctly.</li>
<li>STORAGE: SinExcel PWS2 30K ESS protocol now supports Droop mode but only if Droop mode is set through M-Logic.</li>
<li>SOLAR/STORAGE: Fixed an issue where ESB/PVB close fail alarm did not reset even when closing ES/PV breaker was not needed.</li>
<li>SOLAR/STORAGE: Fixed an issue where M-Logic events for ESB/PVB fail alarms were never active even though the actual alarms were active and not acknowledged.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.21.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-21-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8a81950b-8dbd-485c-9661-196fd7ca5844</guid>
        <pubDate>2024-11-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.21.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.35.1</p>
<h3>Corrections</h3>
<ul>
<li>Corrected an issue that caused parameter #2024 Sync. dUMin to be disregarded as a lower limit for dynamic synchronisation of the voltage if #2023 Sync. dUMax was numerically smaller.</li>
<li>ATS: CB1 and CB2 can now both close in SEMI if #19122 is enabled and BTB is open.</li>
<li>Fixed issue where assigning an analogue output parameter to an already assigned analogue output would fail. Now the newly assigned parameter will have the assigned analogue output, and the parameter where the output was previously assigned will be cleared.</li>
<li>STORAGE: Corrected an issue where parameter 2664 "U ref. gain" had no effect on voltage offsets for ESS protocols SinExcel PWS1, SinExcel PWS2 30K and SinExcel 30P.</li>
<li>Corrected an issue when Modbus telegrams were split into 2 telegrams on Ethernet.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.22.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-22-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f6175cd3-19d9-4738-8f56-be653c6b19d5</guid>
        <pubDate>2025-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.22.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.60.2 PDB rev 11101</li>
<li>TDU version required: 1.4.3.0</li>
</ul>
<p>PM compatibility: 1.35.1</p>
<h3>New features</h3>
<ul>
<li>Added M-Logic commands for enabling and disabling #7501 Comm. bus control P, #7502 Comm. bus control f, #7503 Comm. bus control U, #7504 Comm. bus control cosphi, and #7505 Comm. bus control Q.</li>
<li>CIO 308 inputs set as the binary type can now be used the same way as CIO 116 digital inputs.</li>
<li>EIC: Added support of Wise13.</li>
<li>EIC: Added support of YC-ECU-A including new delta alarms and views.</li>
<li>SOLAR: Added new PV protocol Solis Logger.</li>
<li>SOLAR: Added new PV protocol for Hypontech PV inverter.</li>
<li>SOLAR: Added new PV protocol for SAJ C6.</li>
<li>STORAGE: Ningbo BMS will now read register 284 to check if communication between BMS and Golden Shield controller has been lost.</li>
<li>STORAGE: Added new BMS protocol for WEG BMS.</li>
<li>STORAGE: Added new PCS protocol for WEG BIW610 PCS.</li>
<li>STORAGE: Added new BCU protocol for Kubank LEMS BCU.</li>
<li>STORAGE: Added new protocol for Sungrow LC200 Single PCS.</li>
<li>STORAGE: Added new protocol for Sungrow LC200 DPS.</li>
<li>STORAGE: Added new protocol for Moura BESS BCU.</li>
<li>STORAGE/SOLAR: Added new Modbus register with external DG breaker feedbacks on address 632 with function code 04h.</li>
<li>Added new 32-bit Modbus register with active power load information from addresses 765 to 766 with function code 04h.</li>
<li>STORAGE: Added active and reactive power set point control to GP PID for storage controllers.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>GENSET: Internal values for load dependent start/stop are no longer continuously stored in non-volatile memory to prevent 30 min data storage alarm potentially occurring frequently.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>SOLAR: Corrected an issue where Huawei Smartlogger PV protocol did not support monitoring of multiple Huawei Smartlogger inverters.</li>
<li>Corrected an issue where changing display views between synchroscope and supervision on the AGC 150 display would cause values to stop updating on the supervision view page.</li>
<li>GENSET: If a 4th CT was configured, its measurement was not displayed on the controller supervision view page. This has been fixed.</li>
<li>The synchronisation module now correctly determines when to close the breaker during dynamic synchronisation in configurations where the breaker close time (#2025 and #2026) is high.</li>
<li>Units for parameters 7610 to 7660 and 7690 to 7700 are updated on the display when the engineering unit (9158) is changed.</li>
<li>ATS: Skip source failure timers at startup if source is dead and one of the breakers is closed.</li>
<li>STORAGE/SOLAR: Added internal fix about region counters in operating system.</li>
<li>MAINS: In emulation, the busbar OK status is now purely based on emulated measurements and not the state of the mains breaker.</li>
<li>MAINS: M-Logic synchronisation events now update correctly.</li>
<li>STORAGE: Fixed issue for the Sinexcel 30p protocol where the start and stop commands were not sent correctly.</li>
<li>STORAGE: Added new timings to sinexcel PWS1 telegrams that should fix certain control problems.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.22.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-22-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e76a91f1-6fa9-4a98-94b3-dedf174e039e</guid>
        <pubDate>2025-01-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.22.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.60.2 PDB rev 11101</li>
<li>TDU version required: 1.4.3.0</li>
</ul>
<p>PM compatibility: 1.35.1</p>
<h3>Corrections</h3>
<ul>
<li>SOLAR: Corrected an issue where Q set point was always maxed out on the inductive side.</li>
<li>ENGINE DRIVE: Min/max RPM (2831/2832) are now used for PID actual calculation if engine speed is used as an input.</li>
<li>SOLAR/STORAGE: Corrected issue with the configurable power meter where Modbus addresses above a certain number did not work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.30.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-30-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fa2e00d6-ea3a-451d-b3e9-1c298d2616fe</guid>
        <pubDate>2025-02-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.30.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.61.0</li>
<li>TDU version required: 1.4.3.1</li>
</ul>
<p>PM compatibility: 1.40.0</p>
<h3>New features</h3>
<ul>
<li>Marine GENSET: Able to synchronise and able to be a part of a marine power management system.</li>
<li>Marine SHORE: New product variant for marine power management system.</li>
<li>Marine BTB: New product variant for marine power management system.</li>
<li>Marine STORAGE: New product variant for marine power management system.</li>
<li>Marine SOLAR: New product variant for marine power management system.</li>
<li>STORAGE: Added new PCS protocol for YUNT PCS</li>
<li>EIC: Added support of Yanmar gas 4G.</li>
<li>EIC: Added support of TSC1 destination address and CVT.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>SEMI renamed to MANUAL.</li>
<li>MANUAL renamed to NO REGULATION.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed unintended relay hazard causing certain functions not to be configured.</li>
<li>STORAGE: Fixed issues where ASC 150 Storage could not change the ESS TCP port number.</li>
<li>STORAGE: Fixed issues where the SOC counters on the ASC 150 showed incorrect values both in read and write in specific cases.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.31.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-31-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e0ef82b5-95b2-46e7-b824-03a3355b17d6</guid>
        <pubDate>2025-05-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.31.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.0</li>
<li>TDU version required: 1.4.3.1</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>New features</h3>
<ul>
<li>STORAGE: Added possibility of remote start over Modbus for DSE 8xxx, 7xxx, 6xxx, 4xxx power meter protocol.</li>
<li>STORAGE: Added global/local start of external genset(s) in open PMS.</li>
<li>STORAGE: Added possibility of remote start over Modbus for DEIF Genset control power meter protocol.</li>
<li>STORAGE: Added Lanli Tech BMS protocol.</li>
<li>STORAGE: Added Sicon VSG ESS protocol.</li>
<li>EIC: Added many new SPN texts for DM1 log.</li>
<li>STORAGE: Added Sungrow LC300 protocol support.</li>
<li>EIC: Added support for Scania S6 Industrial.</li>
<li>STORAGE: Added SYL Golden Shield Liquid-cooled (SYL G. S. Liq) BMS protocol.</li>
<li>STORAGE: Added new parameter 8043 "PMS Isochr. Q ctrl" which enables off-grid reactive power regulation in a PMS Isochronous master setup.</li>
<li>STORAGE: Added two new M-Logic outputs for skipping P ramp up and another for P ramp down.</li>
<li>STORAGE: Added three new parameters for following or skipping ramps.
<ul>
<li>Isochronous load share parameter: When the controller is isomaster and another storage controller is on the busbar it will no longer skip ramp if iso load share parameter is enabled.</li>
<li>Over-frequency and under-frequency ramp limit parameters: If measured frequency is above or below these limits the system will skip the ramp.</li>
</ul>
</li>
<li>STORAGE: Added new M-Logic events for when any other battery is charging and any other battery is not "Energy functionality OK" in power management.</li>
<li>STORAGE: Added ABB PCS100 ESS protocol.</li>
<li>STORAGE: ESS and BB nominal voltages are now selectable as set point to general purpose PID.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE: Renamed Ningbo BMS to SYL G. S. Air as it relates to the new protocol.</li>
<li>STORAGE MARINE/SOLAR MARINE: The auto start/stop signal as digital input or M-Logic is no longer needed for allowing hybrid marine variants to auto start.</li>
<li>GENSET: The M-Logic functionality for manual GOV/AVR pulse increase/decrease are now available in the shortcut menu under "Regulation shortcuts" but only works in NoReg mode.</li>
<li>GENSET MARINE: The M-Logic functionality for manual GOV/AVR pulse increase/decrease are now available in the shortcut menu under "Regulation shortcuts" for genset marine in PMS but only works in SWBD control.</li>
<li>M-Logic: 'Virtual toggle' renamed to 'Virtual event' and 'Virtual switch' renamed to 'Virtual toggle'.
<ul>
<li>Virtual events now works the same on Modbus and in M-Logic. The output of the virtual event will follow the input of the virtual event.</li>
<li>Virtual toggles work the same on Modbus and in M-Logic. If the input of the virtual toggle goes high, the output changes state once.</li>
</ul>
</li>
<li>STORAGE/SOLAR/DGHYBRID: Updated internal power ramps to be more precise and allow adjustment of internal delay between ramp updates in parameters 2681 and 2682.</li>
<li>Added parameter 7075, "Mains Fail Assumption", which enables the Mains controller to assume that the mains have just recovered at start-up, allowing it to run the OK timers.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>GENSET LAND &amp; MARINE: If idle run was active, RMI oil pressure alarms would be active before it was detected that the engine was running. This has been changed so that the engine must be running before the alarms can be active.</li>
<li>STORAGE: Fixed issue where the voltage set point does not take voltage transformer into account. Ratio between ESS Nom U (Ch 6004) and BB Nom U (Ch 6053) is now multiplied to take voltage transformer into account when calculating voltage set point to PCS.</li>
<li>STORAGE: Oztek OZpcs-rs40 protocol correction: P and Q set points are now sent in both on-grid and off-grid instead of only on-grid.</li>
<li>Gen stop and GB Off M-Logic command can now stop the genset during the start sequence.</li>
<li>Digital input texts are shown correctly in display menu.</li>
<li>GENSET: M-Logic output to change PMS priority selection (#8031) to fuel optimisation was missing.</li>
<li>Remote display: Supervision view should now work with a continuous display on the remote unit.</li>
<li>ATS: Fixed controller displaying engine symbols at start-up on supervision view page.</li>
<li>HYBRID: Empty parameters in display with parameter list setup is no longer shown.</li>
<li>EIC: Custom DM1 alarms was not triggered. This has been fixed.</li>
<li>Fixed an issue where unsupported application alarm values were incorrect for unsupported Open PMS applications.</li>
<li>GENSET MARINE: ISLAND setup with two gensets now automatically starts second genset based on LD start.</li>
<li>GENSET MARINE and SHORE: TEST function removed. Still available for EDG.</li>
<li>STORAGE: Fixed issue for ESS protocol Sungrow LC200 DPS where charge and discharge capacity scaling was incorrect.</li>
<li>STORAGE/STORAGE MARINE: Fixed an issue where controller could continuously start and stop in AUTO mode.</li>
<li>GENSET MARINE: GB open without deload corrected.</li>
<li>GENSET MARINE: Removed PID1 from shortcut menu when Genset Marine is not a single controller/EDG application.</li>
<li>In the USW parameter list, Mains and BTB controllers would show that an inhibit was applied, even though it was not. This has been fixed.</li>
<li>STORAGE: Kubank LEMS BCU - Fixed issue where DC current could not be shown as a negative value. Added 3 new measurement values for phase voltages.</li>
<li>STORAGE: Updated Nomad BCU protocol - Droop and grid mode logic changed, reading faults and warnings updated to new Modbus addresses and more.</li>
<li>STORAGE/SOLAR: Corrected wrong Modbus addresses like Active power in address 40034 to address 33 and other registers for Cummins PC3 x PCC3300 powermeter protocol.</li>
<li>GENSET: The frequency/voltage regulation mode is no longer dependent on the frequency detection level when running with the GB closed.</li>
<li>GENSET: Show DEF level on all measurement views.</li>
<li>STORAGE: SinExcel PWS2 30K and SinExcel 30P ESS protocols have been adjusted to comply with SinExcel Modbus communication requirements.</li>
<li>M-Logic virtual toggles (previously named switches) can now be read over Modbus.</li>
<li>STORAGE/SOLAR: Fixed an issue where analogue output measurements was not working when measurement origin was set to ESS/PV communication.</li>
<li>SOLAR: Fixed an issue where parameter 7553 "RTU broadcast ID" was not accessible in PV communication menu.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.32.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-32-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">084a9d54-b7d7-4646-b840-35ac0a4a077a</guid>
        <pubDate>2025-06-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.32.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.1</li>
<li>TDU version required: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>New features</h3>
<ul>
<li>STORAGE: Added new protocol, Kehua Tech Local Controller (KC541A)</li>
<li>STORAGE: Added Faro BCU protocol.</li>
<li>STORAGE: Added new BMS protocol "CATL EnerOne Plus"; renamed "CATL liquid cooled" to "CATL EnerOne".</li>
<li>STORAGE: Added a new parameter 17056 "SOC resolution" to allow changing the default resolution for SOC of 1% to 0.1% or 0.01%.</li>
<li>STORAGE: Added CubEnergy BCU and Lithion GB protocol.</li>
<li>EIC: Added fuel rate alarm based on active power.</li>
<li>EIC: Added Guascor GCS-e ECU protocol.</li>
<li>EIC: Added aftertreatment icons for ISUZU.</li>
<li>EIC: Added Volvo Penta D12 protocol.</li>
<li>GENSET: Added counter for a number of successful generator starts.</li>
<li>GENSET: Add support of digital load sharing with SmartGen in SEMI mode.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE: Renamed ESS protocol for Yingbo PCS to InPower PCS.</li>
<li>EIC: Added TSC1 to YC-ECU-A.</li>
<li>EIC: Updated crankcase pressure (SPN 101) to kPa unit in delta alarms.</li>
<li>EIC: Updated Cummins PGI to version 4.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>STORAGE: Fixed an issue where single controller in AMF would charge from Mains when energy functionality was OK and "SOC + plant assist charging" was used as Mains charging mode.</li>
<li>STORAGE: Fixed an issue for Sungrow LC300 where heartbeat was not working.</li>
<li>STORAGE: Fixed several issues for WEG BIW610 PCS and WEG BMS:
<ul>
<li>WEG BIW610 PCS registers which were interpreted as big endian are now interpreted as little endian byteswap.</li>
<li>WEG BIW610 PCS sends nominal voltage/frequency on registers 500 and 508.</li>
<li>WEG BIW610 PCS will only send start signal when PCS is in the "Waiting" state.</li>
<li>WEG BMS sends a pulse every 90 s to register 95 for connecting BMS clusters.</li>
<li>WEG BMS will trigger BMS warning on every 'minor' alarm register with function code 0x02 and BMS shutdown on every 'moderate' alarm register with function code 0x02.</li>
</ul>
</li>
<li>STORAGE/SOLAR: Fixed inaccessible menus in tree and parameter views on display.</li>
<li>STORAGE/SOLAR/DGHYBRID: Corrected scaling of active power set point with non-default parameter 9030.</li>
<li>Configured Droop curve 2 with power factor output, now functions correctly.</li>
<li>STORAGE/SOLAR: Prevented mix-up of readings when using multiple powermeter types.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.32.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-32-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">674c8fef-db15-4902-9fa8-ea967b091c76</guid>
        <pubDate>2025-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.32.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>Requirements</p>
<ul>
<li>USW version: 3.62.1</li>
<li>TDU version: 1.4.5.0</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>EIC: Added SPN 5579 to delta alarms</li>
<li>Updated the Megarevo MPS ESS protocol</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.33.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-33-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">64a932c2-22ea-46e2-abc2-231849ee11bf</guid>
        <pubDate>2025-07-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.33.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.1 PDB rev 11714</li>
<li>TDU version required: 1.4.5.0</li>
<li>PM compatibility: 1.41.0</li>
</ul>
<h3>New features</h3>
<ul>
<li>EIC: Added Mitsubishi protocol.</li>
<li>EIC: Added MTU ECU9 EMINOX protocol.</li>
<li>EIC: Added VECV E694 CPCB IV protocol.</li>
<li>STORAGE: Added new protocol - Qualtech BMS.</li>
<li>STORAGE: Added new ESS protocol - Sungiga SCU.</li>
<li>STORAGE: Added SinExcel PDS1-750K protocol.</li>
<li>STORAGE: Added Nari PCS 9567AN protocol.</li>
<li>SOLAR: Added new weather station protocol - Seven Sensor 3S-CWS.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>EIC: Updated Kubota Stage V to show alarms and texts for PCD/NCD and request PGN AT1S.</li>
<li>EIC: Added jump from alarm log to DM1 log.</li>
<li>GENSET: Added alarm to detect if primary starter has failed and the double starter is used instead (#6192).</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where Droop Curve 2 did not calculate cos phi droop correctly when leaving the deadband with a cos phi of less than 1.0.</li>
<li>Fixed an issue where the transfer of ground relay from deloaded genset to battery did not overlap.</li>
<li>Racked-out breaker can now be used when the controller is in BLOCK mode.</li>
<li>When DGs are forced to analogue load-share in a PMS setup, they can now back synchronise to the mains when directed to.</li>
<li>J1939-75 DM1 alarms now work again.</li>
<li>Fixed an issue where the scaling of values in the DG supervision view was incorrect.</li>
<li>STORAGE: Fixed an issue for FARO BCU where the active power set point would not be set. A new register, Enable active power set point, has been added to allow the active power set point to be set.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.34.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-34-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf4f647a-f96e-40e2-aa3c-58601d560b14</guid>
        <pubDate>2025-10-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.34.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.64.0 PDB rev. 11948</li>
<li>TDU version required: 1.4.5.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New features</h3>
<ul>
<li>GENSET: Added support for digital load sharing with ComAp in MAN mode.</li>
<li>EIC: Added protocol Wise18B.</li>
<li>EIC: Added protocol Kingbang.</li>
<li>EIC: Added protocol SDEC F31.</li>
<li>EIC: Added protocol SDEC F36.</li>
<li>EIC: Added protocol Yunnei.</li>
<li>EIC: Added protocol Yanmar X11.</li>
<li>EIC: Engine values now available in the shortcut menu.</li>
<li>STORAGE: Added new power management feature “SOC balancing”, which balances power between paralleling batteries.</li>
<li>STORAGE: Add two more PIDs to the system.</li>
<li>STORAGE: Added new BMS CAN protocol "Volvo Penta BE-C-03-GE".</li>
<li>STORAGE: Added new protocol Jinko JKP-1xxxHN-CA PCS.</li>
<li>STORAGE: Added Greatpower BMS protocol.</li>
<li>STORAGE: Added Jinko Utility BMS protocol.</li>
<li>STORAGE: Added Sungrow EMS300CP protocol.</li>
<li>STORAGE/SOLAR: Added new power meter protocol ComAp InteliGen 500 G2 for hybrid variants.</li>
<li>STORAGE: Added new protocol Delta PCS 1000.</li>
<li>STORAGE: Added new options in parameter 15016 “Opt. GEN load set” for dynamic start/stop of gensets.</li>
<li>In sync configurable relay output added, based on frequency (f), voltage (U), and phase angle (phi). Uses the same evaluation as the M-Logic flags.</li>
<li>PMS Lite: Added support for up to 254 controllers. Version increased to 5 and is not backwards compatible with earlier versions.</li>
<li>PMS Lite: Added support for BTB controllers in MANUAL mode.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE: ESS protocol “SinExcel PWS1” now uses protocol custom input to switch between new and old voltage offset regulation.</li>
<li>SOLAR: PV protocol "Deye SUN 30-50k-G03" is using protocol custom input to change between registers 40/41 for old P/Q regulation registers and registers 290/291 for new P/Q regulation registers.</li>
<li>EIC: Added coolant pressure (SPN 109) to delta alarms.</li>
<li>EIC: Seawater pump pressure added to view lines.</li>
<li>EIC: Water in fuel 2 (SPN 6301) added to view lines and M-Logic.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>STORAGE: Modbus registers 2975 and 2986 for ESS protocol “EPC Power” can now be forced to enable via “Set mode to Droop” M-Logic command.</li>
<li>STORAGE: Added missing DC voltage and current readings for ESS protocol Sicon VSG when used without a selected BMS protocol.</li>
<li>STORAGE: Added missing Modbus register timings for ESS protocol “SinExcel PWS2 30K”.</li>
<li>STORAGE: Fixed issue where contactor control was sent too frequently for BMS protocols “CATL EnerOne BMS” and “CATL EnerOne Plus BMS”.</li>
<li>SOLAR/STORAGE: Fixed issue where M-Logic output for “Inh. inverter start” had no effect.</li>
<li>STORAGE: Fixed issue where Q reference ramped instantly to 0 during stop.</li>
<li>SOLAR: Fixed issue where Solis PV read incorrect serial numbers.</li>
<li>SOLAR: Removed division by 2 of P setpoint in FIMER PVS980 inverter. This adjustment was originally made to compensate for an error in the FIMER inverter, which has now been resolved in the latest inverter firmware.</li>
<li>BTB: Fixed issue where active power measurement was incorrectly displayed as reactive power measurement in application supervision.</li>
<li>Display: Multi inputs now show the specifically configured measurement unit instead of defaulting to the unit of multi input 20.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.34.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-34-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">24b4367b-21db-4a67-a37b-24bf20391ec3</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.34.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.64.0 PDB rev. 11948</li>
<li>TDU version required: 1.4.5.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>MAINS: Fixed an issue where Mains OK Delay f and U timers were always overruled when only batteries in plant.</li>
<li>GENSET MARINE: Fixed an issue where a PMS CAN failure caused a blackout on the busbar and did not properly keep the controller in SWBD mode.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.35.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-35-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e723ca80-86b6-496a-9090-fbe8b2a4733a</guid>
        <pubDate>2025-10-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.35.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<p>Required versions and compatibility</p>
<ul>
<li>USW version required: 3.64.1 PDB rev. 12031</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New functions</h3>
<ul>
<li>EIC: Added Perkins CPCB IV.</li>
<li>EIC: Added Volvo Penta CPCB IV.</li>
<li>EIC: Added SPN 7831 to CM2358.</li>
<li>STORAGE: Added four M-Logic outputs for plant force discharging, plant force charging, plant freeze discharging, and plant freeze charging in SOC balancing mode.</li>
<li>STORAGE/SOLAR: Added new service view to check which individual power meter communication is active or inactive.</li>
<li>STORAGE: Added four new parameters for setting up droop/VSG deadband regions to be sent to ESS protocols. Added droop deadband registers 1249 and 1250 to be written for SinExcel PWS2 30K ESS protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE/SOLAR: Added timer to parameter 7730 "GEN meter err.", parameter 7740 "ESS meter err.", and parameter 7750 "Mains meter err.".</li>
<li>STORAGE/SOLAR: Power meter data for the power meter losing communication is now reset when the corresponding meter error alarm is triggered.</li>
<li>STORAGE: All write registers for SinExcel PWS2 30K have been set to a minimum interval of 5 s, except for 1024, 1025, and 1217 which are set to a 10 ms interval.</li>
<li>STORAGE: Added custom input to SinExcel PWS2 30K for whether Droop/VSG mode is available. Setting droop through M-Logic now writes 1 to register 1236; disabling droop through M-Logic writes 0 to register 1236.</li>
<li>STORAGE: Changed "iE 150 Storage" to "iE 150 Battery".</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>EIC: Engine values in short-cut menu texts now display correctly.</li>
<li>Compact breaker: Breaker off relay now closes only once and remains closed for spring charging.</li>
<li>GENSET: Controllers with S1 configured with DVC 350 no longer experience 'illegal data value' when using the USW.</li>
<li>STORAGE: Megarevo MPS correction – start/stop commands, active power, and reactive power set points now update correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.36.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-36-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6b95fdd2-4b96-40de-a6c9-19206a1928f6</guid>
        <pubDate>2026-01-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.36.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<h4>Version 1.36.0 (based on 1.35.0)</h4>
<ul>
<li>USW version required: 3.64.3 PDB rev. 12236</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New features</h3>
<ul>
<li>BATTERY: Added new ESS CAN protocol EODev.</li>
<li>BATTERY: Moved updates to ESS protocol EPC Power from SIPC 0655. Added ESS protocol custom inputs to EPC Power for controlling autoforming and reconnect delay.</li>
<li>GENSET HYBRID/SOLAR/BATTERY: Added M-Logic events for PV/ESS running, starting, stopping, ramping, and derated.</li>
<li>BATTERY: Added M-Logic events for selected SOC balancing mode and “SOC above or equal to plant SOC ...” events.</li>
<li>BATTERY: Added M-Logic events for external genset on busbar.</li>
<li>Added Command Schedulers (previously available in ASC 150 Battery) to the following controller types: GENSET, GENSET HYBRID, GENSET MARINE, ATS, and GENSET PMS lite.</li>
<li>EIC: Added ACU CPCB IV protocol.</li>
<li>SOLAR: Updated Solis and Polycab PV protocols. Added more string power and current measurements. It is now possible to read up to 10 power and current measurements.</li>
<li>Added new predefined multi-input RMI water temperature curve: “CAT sensor-temp”.</li>
<li>Added new predefined multi-input VDC pressure curve: “CAT sensor GP-pressure”.</li>
<li>MAINS: Now supports negative fixed power setpoints for fixed import power when operating in parallel with batteries.</li>
<li>EIC: Added Farizon protocol.</li>
<li>Added new 32-bit Modbus register for reactive power load information at addresses 767 to 768 using function code 04h.</li>
<li>SOLAR: Added new PV protocol “Kehua Logger KM-ACU50”.</li>
<li>BATTERY: Added new ESS protocol EOS energy block v2.</li>
<li>SOLAR: Added new PV protocols: WEG SIW610, WEG SIW400g, and FOXEss R/V.</li>
<li>EIC: Added Wise10 protocol.</li>
<li>SOLAR: Added Sineng SACU Datalogger protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>SOLAR: Changed read addresses for string power and voltage for Solis (Ginlong) and Polycab 50–60 kW.</li>
<li>Mult-input alarm setpoints are now converted upon change of parameter #9158 Engineering units, if the multi-input is of type RMI oil pressure or RMI water temperature.</li>
<li>When changing parameter 9158 "Engineering units", the predefined RMI water temperature, RMI oil pressure, and VDC pressure curves are converted to the configured engineering unit.</li>
<li>When changing parameter 9158 "Engineering units", the configurable curves for RMI water temperature and RMI oil pressure are converted to the configured engineering unit.</li>
<li>GENSET: Multi-inputs configured as mA or V can now be assigned a predefined use. These values are now shown in the supervision view.</li>
<li>BATTERY: AMF for single and PMS now supports plant assist charging. When SOC is below SOC threshold high and energy functionality is OK, the battery will charge according to the mains charging setpoint when the grid is normal and connected.</li>
<li>BATTERY: Parameter 17024 “PS charging limit” has been renamed to “Mains charging limit”, as it is now also supported for MPE and Fixed Power in both single and PMS configurations.</li>
<li>EIC: Added fault code texts for Yanmar x11.</li>
<li>EIC: Added pre-lube logic for Yanmar x11.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added new parameter 2750 “Frequency recovery” for handling frequency recovery specifically for Volvo Penta engines during 100 % active power load jumps.</li>
<li>GENSET MARINE: Fixed an issue where the busbar was not restored from blackout during CAN failure in AUTO mode.</li>
<li>Fixed an issue where “Service view” was incorrectly shown as the submenu text in the “Ethernet setup” and “PM Ethernet setup” menus.</li>
<li>Fixed an issue where parameter 8930 “Spinning reserve” was unintentionally enabled in a power management setup after power cycling a single unit.</li>
<li>BATTERY: Fixed an issue where batteries in the stopping state did not overlap ground relays with other batteries or gensets.</li>
<li>SDU: During power cycle, the iE 150 now sends a reset after 3 s and also sends a reset when the status alarms disappear.</li>
<li>BATTERY: Fixed an issue where batteries charged from MAINS when MAINS was connected but had MAINS failure.</li>
<li>BATTERY: Fixed an issue where batteries in parallel with gensets charged more from MAINS when using parameter 17024.</li>
<li>SOLAR: Parameter 7960 “DEIF Generic offset” is no longer visible on Solar controllers.</li>
<li>BATTERY: Volvo Penta BMS protocol now reads the correct telegram with PGN 0xFFB0 for DC current and DC voltage.</li>
<li>BATTERY: Fixed an issue where protocol custom inputs were reset after power cycle.</li>
<li>SOLAR: Fallback timer for power limit on parameter 17180 "SunSpec" is now also written to reactive power.</li>
<li>BATTERY: Fixed an issue where ASC150 was sending start to incorrect registers and where starting in PQ mode was not always allowed.</li>
<li>BATTERY: Corrected Sungrow EMS300CP telegrams.</li>
<li>HYBRID: P and Q ramp now acts correctly after back synchronising of MB – both PMS and single controller (bug introduced in version 1.31.0).</li>
<li>The unit for RMI custom multi-inputs is now displayed correctly in the display.</li>
<li>Test mode is no longer cancelled when mode is issued.</li>
<li>PMS lite: Fixed an issue where the AVR regulator used the wrong setpoint for Q loadshare regulation.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 150 Application Software &#x2013; v1.36.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-150-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-36-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d5abc5d2-f0d6-4c20-894d-bb23246f5699</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 150 Application Software</category>
        <category domain="version">1.36.1</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC 150 Remote Display</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
        <content:encoded><![CDATA[
<h3>Version 1.36.1 (based on 1.36.0)</h3>
<ul>
<li>USW version required: 3.64.3 PDB rev. 12236</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS lite compatibility: 5</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>EIC: Added fuel consumption to the requested PGN list for protocol Cummins PGI.</li>
<li>GENSET HYBRID/SOLAR: Fixed an issue where the controller restarted when Kehua SPI PV protocol was selected.</li>
<li>HYBRID: Fixed a Modbus client issue for hybrid protocols which required a restart of the controller after configuration.</li>
<li>GENSET MARINE: Fixed an issue where multi-start parameters were not taken into account for blackout recovery in AUTO.</li>
<li>PMS lite variants: Fixed an issue where menu 7050 was not available on PMS lite variants.</li>
<li>BTB: Fixed an issue where, if powered up with a breaker position failure, the controller could request gensets to start and close their breakers.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 200 Application Software &#x2013; v4.68.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-200-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/4-68-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">78c8c84f-9a16-4431-98d1-882f1a72edc0</guid>
        <pubDate>2020-08-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 200 Application Software</category>
        <category domain="version">4.68.4</category>
          <category domain="product">AGC 200</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.16.1<br />Includes version 1.02.0 + 1.15.2</p>
<h3>Corrections:</h3>
<ul>
<li>   Situations where multi start would not work correctly in island and AMF applications are corrected.</li>
<li>   In AMF situations where the mains had no TB and #7065 mains fail, ctrl was set to "Start engine" and the DGs had to connect through a BTB to supply the mains. The MB would not open because it did not have information about whether or not the DGs Hz/V OK timer had run out. The MB would not open and the BTB would not close, resulting in a deadlock. This has been corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 200 Application Software &#x2013; v4.68.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-200-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/4-68-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fe20d2b8-dd64-4242-a67f-0f22946cc0c2</guid>
        <pubDate>2021-07-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 200 Application Software</category>
        <category domain="version">4.68.5</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC 200</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.16.1.<br />Includes version 1.02.0 + 1.15.2.</p>
<h3>Corrections:</h3>
<ul>
<li>Corrected that PMS island load sharing and asymmetrical load sharing did not work correctly when #9030 Scaling was set to other than default.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC 200 Application Software &#x2013; v4.68.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-200-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/4-68-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5b9b1b0b-25f7-407f-86d6-58cc605a5f7e</guid>
        <pubDate>2020-04-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC 200 Application Software</category>
        <category domain="version">4.68.3</category>
          <category domain="product">AGC 200</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.16.1.<br />Includes version 1.02.0 + 1.15.2.</p>
<h3>Corrections:</h3>
<ul>
<li>   Modbus interface is corrected due to receiving USW paramter files.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 2.x. &#x2013; v2.40.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-40-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">413b4e3e-5217-42cf-b80c-e04235952587</guid>
        <pubDate>2015-03-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 2.x.</category>
        <category domain="version">2.40.8</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC-2</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Update of self-check functionality</li>
<li>Vector jump calculation improved</li>
<li>Zero sequence alarms improved</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 2.x. &#x2013; v2.40.9</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-40-9/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0bb35f44-663f-4e7d-ac43-5c4c922dbeda</guid>
        <pubDate>2015-07-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 2.x.</category>
        <category domain="version">2.40.9</category>
          <category domain="release-status">current</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC-2</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Update of self-check functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 3.x. &#x2013; v3.65.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-65-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a3b0c362-1cf8-40ca-9e22-66ad880f40fb</guid>
        <pubDate>2014-07-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 3.x.</category>
        <category domain="version">3.65.5</category>
          <category domain="product">AGC-3</category>
        <content:encoded><![CDATA[
<ul>
<li>AMF sequence was incorrect in some cases</li>
<li>TB could open inappropriately when switching from AMF to LTO</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 3.x. &#x2013; v3.66.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-66-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">32ac1e09-56c7-4275-b15d-d2e29762daa3</guid>
        <pubDate>2015-03-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 3.x.</category>
        <category domain="version">3.66.1</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC-3</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support of mainboard "uP 8 PCB".</li>
<li>Support of CAN bus hardware "Option H8.2 HW v2" requires mainboard "uP 8 PCB".</li>
<li>Support of CAN bus hardware "Option H5/H8.8 HW v2" requires mainboard "uP 8 PCB".</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Under AMF applications where a second mains fail occurs with at least one DG running, the remaining DGs are now started with a multi start.</li>
<li>Under AMF applications where a second mains fail occurs with at least one DG running and power cap overrule enabled, the timer is now reset (started over again) when DGs are ready and synchronised.</li>
<li>Start enable was required to be energised, if used, to activate the breakers - corrected.</li>
<li>Genset could start when SEMI button was pushed and no start signal had been given (occurred only with Option V0108 German display only).</li>
<li>Faulty situation where the AGC-3 could reboot unexpectedly has been prevented (occurred only with Option N).</li>
<li>AGC Mains MB opens unwantedly - corrected.</li>
<li>Parameter 3410 relay A setup corrected, so display shows correct value.</li>
<li>When LTO is activated with no Sync to mains; a delay is added to ensure that multimains status has been evaluated, before it is determined if MB should open.</li>
<li>After MTU has released a new software for the SMART CONNECT module, the alarm "AL Speed Demand Failure" was always present due to a change in timeout changed from ~40m[s] ==&gt; ~10m[s].</li>
<li>Multimains MB fail control of 'Start engine' selection now used in AMF sequences.</li>
<li>AGC-3 could reboot after CAN protocol change, if there was active CAN communication on the CAN line during the protocol change.</li>
<li>Ut13-If an LTO sequence was initiated while an auto switch was active, an MB could end up opening and closing in endless loop - corrected.</li>
<li>Attempting to stop during idle at start would ramp the engine to full speed and keep it running, if the running detection speed was reached during idle run.</li>
<li>GB could previously close onto a black busbar when another unit had GB position failure.</li>
<li>Update of self-check functionality.</li>
<li>MB was able to open even though it was excluded from the LTO sequence - corrected.</li>
<li>In LTO, if the TB was tripped by the TB Trip fail class, the MB was not able to close in all situations - corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4-80-0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-80-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0b80897c-0c64-4af8-8359-a13387428ca2</guid>
        <pubDate>2020-11-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4-80-0</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.<br /><br />Option N compatibility: Minimum SW version 2.00.3 is needed, because the limitation of 4000 text strings is exceeded.</p>
<h3>New features:</h3>
<ul>
<li>Configurable spinning reserve request using parameter 8930 (not supported in BTB applications).</li>
<li>The remote maintenance box (RMB) is now supported in an island Power Management configuration up to 32 DGs (requires option T4).</li>
<li>Blocking of nominal parameter set change when engine running is added. The new parameter 6016 in DG is only available from the USW.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Support of ASC-4 redundancy.</li>
<li>Shows Racked out breaker On/off in the log.</li>
<li>Shows Tier-4 symbol for Scania S8 inducement failures.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fuel optimization + running hours does not change at fixed load.</li>
<li>Corrected: Configurable amount of Fatal CAN error alarms could change when multiple units were powering up.</li>
<li>Corrected: Configuring a mains stand-alone application with the CAN bus set to OFF in the application configuration prevented the MB from closing.</li>
<li>Corrected: If a DG was running with its GB open and ground relay closed, and a mains then connected to the busbar, the ground relay would open.</li>
<li>Alarm texts from DVC550 are now shown correctly.</li>
<li>Added an alternative engine speed control for Volvo protocols including counter and checksum. Can be enabled with the new parameter 15110.</li>
<li>Added a Power derate calculation low limit for inverse proportional slope (only used for multi-inputs 102, 105 and 108 configured as mA measurement.</li>
</ul>
<div></div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.80.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-80-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1f1f7fa9-3e36-48e8-b51c-bc1c70fd09e6</guid>
        <pubDate>2021-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.80.2</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.</p>
<p>Option N compatibility: Minimum SW version 2.00.3 is needed, because the limitation of 4000 text strings has been exceeded.</p>
<h2>Corrections:</h2>
<ul>
<li>N + X now works when Fuel optimisation is in use.</li>
<li>QSK60G EIC auto view is now showing correct values.</li>
<li>Manual priority update now works when more than 16 gensets or mains controllers are present in the plant configuration.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.80.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-80-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">390ed1b8-6cd8-4eb7-ad52-783961822340</guid>
        <pubDate>2020-12-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.80.1</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0<br /><br />Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>Transmit of DVC 550/D550 parameters over the CAN was irregular.</li>
<li>Menu 6231 for GB close delay no longer available when application is power management.</li>
<li>Add support for Volvo engine with 60Hz as primary speed when Volvo proprietary engine speed is used.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4-79-3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-79-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6fdcf46d-5217-4165-9671-4e4dd8db8f77</guid>
        <pubDate>2020-09-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4-79-3</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.18.0.<br />Includes versions: 1.02.0 &amp; 1.17.2.<br /><br />Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>   New parameter #7746 DAVR AC config introduced when communicating with DVC550. This is used when split phase is needed and allows the DVC550 to follow the AC configuration on the AGC.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.81.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-81-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">99f1562d-73ff-4580-8ec4-6de5f5ec9733</guid>
        <pubDate>2021-05-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.81.1</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.0.</p>
<p>Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>Channel number 4800 is no longer duplicated when M15_8 or M16_8 is mounted. All channel numbers in relation to these options are increased by ten.</li>
<li>G7 redundant plant in ISLAND mode now starts and stops properly for groups not having the start/stop signal.</li>
<li>Limit events are added in M-Logic for Extended M-Logic Alarms.</li>
<li>TDU is now able to change to BLOCK-mode. Requires TDU version 1.3.7.0.</li>
<li>Short circuit supervision (option T1) now includes PV and battery units connected. Requires ASC-4 version supporting option T1.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.81.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-81-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f35b66b9-8417-4b07-a6db-4284e243659f</guid>
        <pubDate>2021-04-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.81.0</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.23.0.</p>
<p>Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.</p>
<h3>New features:</h3>
<ul>
<li>Four new M-Logic alarms with extended delay are added in menu 3620-3650.</li>
<li>Support of PSS module in DVC 550 is added.</li>
<li>New GOV and AVR step test is added in the parameter group #2970.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Event logging is added when the application setup changes.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Generator under-frequency and under-voltage alarms are now inhibited during idle run.</li>
<li>DVC 550/D550 communication would not work correctly when EIC and ext. modules DEIF protocols were selected on two CAN ports. This is corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.80.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-80-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f4bac9b3-a50c-4b81-94c1-1c5f543e092c</guid>
        <pubDate>2021-02-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.80.3</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.22.0.</p>
<p>Option N compatibility: Minimum SW version 2.00.3 is needed, because the limitation of 4000 text strings has been exceeded.</p>
<h2>Corrections:</h2>
<ul>
<li>Corrected an issue that caused a mains controller to not being able to control the PF setpoint (cos phi control) on genset controllers (introduced in v.4.80.0).</li>
<li>Manual PMS priority data is maintained correctly internal in all genset controllers (introduced in 4.75.0).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.81.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-81-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">99decb38-8196-46a8-871c-d3acc9427728</guid>
        <pubDate>2021-11-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.81.2</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<p>1- 'Fuel optimization' and 'Fuel optimization + running hours' is now working when using percent values.<br />2- Translation now works even though no DU-2 is mounted AND only new language is written.<br />3- Deload TB before GB opens function works correctly in PEAK SHAVING.<br />4- CBE sequence with 'Excitation OFF during cooldown' working again. Was compromised in version 4.80.0.<br />5- PMS priority change via M-Logic or Modbus now works correctly.<br />6- CIO 308 wirebreak detection now works correctly.<br />7- No ASC-4 PV irradiance sensor could make AGC DG's provide inadequate power for mains power export.<br />8- 'PM protocol error' alarm appears if 'protocol 2' is selected, and another unit is set to protocol 1.<br />'Unsupported application' alarm appears if 'protocol 1' is selected and ID higher than 16 is used in the entire plant.<br />9- Cos-phi superior set points now work with only PV or Battery units on the busbar together with an AGC mains.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.82.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-82-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0d11e990-458a-437c-8cd3-0633834410f2</guid>
        <pubDate>2022-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.82.0</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>New features:</h3>
<ul>
<li>M-Logic flags for Enable / Disable Ext power ref via Comm and Ext frequency ref via Comm added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Busbar block handling in PMS now allowed to let the system (DG, MAINS etc.) run even though any breaker has position failure.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>When setting parameter #1204 Freq trip type to 'L1 and L2 and L3', the busbar frequency alarms would end up using the generator measurement.</li>
<li>TDU can show the DEF level when Scania EMS2 S8 is used as engine I/F.</li>
<li>N + X ON/OFF via digital input or M-Logic corrected.</li>
<li>M4 multi-inputs mA scaling with AutoScale corrected.</li>
<li>Extended John Deere stage V engine protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.82.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-82-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ea7426e4-afcd-4865-884e-76c72941c3da</guid>
        <pubDate>2022-03-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.82.1</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>
<ul>Scania EMS2 S8 is now showing the correct regeneration symbols.</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.82.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-82-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d0e19b5f-5ec6-4b47-87f5-0a56f2961a01</guid>
        <pubDate>2022-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.82.2</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>A genset will now charge a battery with the correct amount during negative PMS setpoints.</li>
<li>A genset will now calculate the correct power reference if a battery operating as an energy source is charging from excess PV power.</li>
<li>A mains could issue a start signal to DGs based on invalid power management data when a BTB was power-cycled.</li>
<li>Idle run stops engine correctly when using Low speed input.</li>
<li>In rare cases connected DGs could trip and stop, when units disconnected from PM reconnects.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.82.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-82-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d857dcc1-9de8-4c48-bbb8-d3712d8fef0f</guid>
        <pubDate>2022-08-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.82.3</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>PMS island loadsharing would not work correctly when #9030 Scaling was set to something else than default. This has been corrected. PMS asymmetrical loadsharing in island also corrected when using a different scaling than default.</li>
<li>Corrected an issue where two or more DGs could end up with the same priority.</li>
<li>In a plant where a static island is composed of mains controllers with no TB and a DG can only connect through a BTB, backsynchronization of the MBs did not work as intended. This has been improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.82.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-82-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">78429801-49dc-4178-a961-94685fa9bdcb</guid>
        <pubDate>2022-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.82.4</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>FMS scaling corrected.</li>
<li>CBE re-run no longer closes generator breaker directly on black busbar with cooldown control set to excitation ON.</li>
<li>MAINS unit power measured with open MB no longer added to available power in DG.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0b5fbdc7-c590-4b62-bca6-a8e121a44e0d</guid>
        <pubDate>2023-03-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.0</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: SW version 2.00.3 needed as a minimum because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>Corrected issue where specific PV spinning reserve values in a plant with a battery and DGs could cause genset start/stop looping.</li>
<li>Corrected issues where PV spinning reserve values in a plant with a battery, PV, Mains and DGs would not start and stop the gensets at the correct available power.</li>
<li>The TB is closed even though a PV is the only power source connected to the busbar.</li>
<li>Corrected issue where PV did not produce the correct Q based on its capability curve and P/Q cap. limit in PMS applications.</li>
<li>Power meters in application supervision no longer shown on external BTB.</li>
<li>It is no longer possible to force CAN transmit on EIC line to stop in certain circumstances.</li>
<li>Corrected issue where PV did not produce the correct Q to meet the requested grid PF. This is when the plant operates with a voltage-based droop and the mains voltage changes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">880e10ac-8706-4d29-a351-4a51edc136f2</guid>
        <pubDate>2023-06-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.1</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<ul>
<li>CAN transmit on the EIC line can no longer be forced to stop in certain circumstances.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">86d407d8-4b70-4712-a4c4-65c04e9da244</guid>
        <pubDate>2023-09-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.2</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<p>• Manual PMS priority update via digital input or M-Logic secured to only take place on one DG within 10 seconds.<br />• Manual PMS priority update via digital input or M-Logic now works in 32DG applications.<br />• When writing a batch file, the correct language is not applied instantly in the USW when using Ethernet. This has been improved with a status text to show the user what happens.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">78bd983a-fd9d-45f7-bf7c-e091999cb602</guid>
        <pubDate>2023-09-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.3</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections:</h3>
<p>• RMB T4: When back synchronising to the mains, the display automatically shows the synchroscope. The buzzer in the RMB box also sounds when the static synchronisation check is fulfilled.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c365b179-3ffa-42c9-a4bf-6c5d7c1f3e2a</guid>
        <pubDate>2024-03-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.4</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p><strong>PM compatibility: 1.24.2</strong></p>
<p> </p>
<p><strong>Corrections:</strong><br />• Change of ID to Run with Run one MAINS during active LTO is now working correctly.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c8e8a8bf-bf99-47e0-8473-599dc78b79de</guid>
        <pubDate>2025-04-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.5</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.61.0</li>
<li>TDU version required: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.</p>
<h3>Corrections</h3>
<ul>
<li>MAINS controlled Fixed for Imp/Exp with low MB power caused unstable PF in GENSETs. This has been corrected.</li>
<li>The synchronisation module now correctly determines when to close the breaker during dynamic synchronisation in configurations where the breaker close time (#2025 and #2026) is high.</li>
<li>Fixed handling of PMS telegrams when only main processor is restarted.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC Application Software series 4.x. &#x2013; v4.83.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-83-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7c4cee09-368b-4400-ac43-c39ced6a0659</guid>
        <pubDate>2025-10-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC Application Software series 4.x.</category>
        <category domain="version">4.83.6</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version: 3.57.0</li>
<li>TDU version: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.24.2</p>
<p>Option N compatibility: Minimum software version 2.00.3 is required due to the limitation of 4000 text strings being exceeded.</p>
<h3>Corrections</h3>
<ul>
<li>Compact breaker types: The breaker OFF relay is now closed once and remains closed for the charge duration before opening.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.04.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-04-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1642365a-9ec4-4bdb-91e1-0168c5e22ef6</guid>
        <pubDate>2021-11-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.04.2</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.1</p>
<h3>Corrections:</h3>
<ul>
<li>Minimum load was not respected when using droop curve 1.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.01.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-01-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1813e405-9316-4f21-a7a1-890150696f46</guid>
        <pubDate>2021-01-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.01.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>UL approved version</p>
<p>PM compatibility: 1.22.0</p>
<h3>New features:</h3>
<ul>
<li>   Added support for Yuchai Diesel+Gas J1939 protocols.</li>
<li>   Addded support for Weichai Diesel+Gas J1939 protocols.</li>
<li>   Added support for MAN J1939 protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.01.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-01-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">37345709-11ff-4802-9ed6-44110a2d6187</guid>
        <pubDate>2021-03-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.01.2</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.22.0</p>
<h2>Corrections:</h2>
<ul>
<li>The 4-20 mA output of the option EF5 analogue card now works again.</li>
<li>Power factor set point on Modbus is now correctly initialized after a power-up.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.04.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-04-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5bbceac7-788d-4462-a587-aaad9dcc59c0</guid>
        <pubDate>2021-11-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.04.3</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.1</p>
<h3>Corrections:</h3>
<ul>
<li>Simulating grid frequency via multi-input for droop curve 1 was off by a factor of 10.</li>
<li>A change to a different configuration than application 1 using the USW would not persist past a powercycle of the controller.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.02.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-02-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6bd97419-54c0-41bf-a64a-b0d9ba490afb</guid>
        <pubDate>2021-04-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.02.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.23.0</p>
<h3>New features:</h3>
<ul>
<li>Support for FPT + Iveco Stage V EIC protocol is added.</li>
<li>Four new M-Logic alarms with extended delay are added in menu 3620-3650.</li>
<li>VDE 4110 support with MAINS unit in power management is added.</li>
<li>Event log entry is added when application setup changes.</li>
<li>Support of DVC 550 PSS is added.</li>
<li>New GOV and AVR step test are added in parameter group #2970.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>CIO alarms are added to Modbus.</li>
<li>Minimum set-point is lowered to 10% for low AC voltage alarms.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>QSK60G EIC auto view is showing correct values.</li>
<li>DVC 550/D550 communication when EIC and Ext. Modules DEIF protocols were selected on two CAN ports is corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.02.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-02-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">841eb1b3-9111-4457-80a0-4feeecc8f424</guid>
        <pubDate>2021-05-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.02.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>UL approved version</p>
<p>PM compatibility: 1.23.0</p>
<h3>Corrections:</h3>
<ul>
<li>Plant management Group Tie redundancy is improved in AUTO and ISLAND plants to secure groups without a start signal to start and stop properly when in need of a redundant unit.</li>
<li>Corrected the text for IP, subnet, gateway.</li>
<li>Corrected that alarm and battery logs where not shown correctly when the number of entries reached maximum.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.04.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-04-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8d92b4c0-1b2a-411e-a41e-a32a926d080d</guid>
        <pubDate>2021-10-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.04.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.24.1</p>
<h3>Corrections:</h3>
<ul>
<li>Island ramping when loadsharing over CAN or analogue line now works again.</li>
<li>Fixed an issue with the EEPROM storage layout.</li>
<li>Changing application configuration with jump menu #9160 would not be stored in longterm storage.</li>
<li>If the ground relay was enabled and the application configuration was a non PMS single DG, the GB would not open when deloaded.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6-00-0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9f51613a-cfbf-4c8a-9f8b-2e8f220f6648</guid>
        <pubDate>2021-01-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6-00-0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.22.0<br /><br />   - Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.01.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-01-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d4620a99-af69-4cec-b426-2f1ec99063d1</guid>
        <pubDate>2021-02-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.01.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.22.0</p>
<h2>Corrections:</h2>
<ul>
<li>Corrected an issue that caused a mains controller to not be able control the PF setpoint (superior cos phi) on genset controllers.</li>
<li>N+X now works when Fuel optimisation is in use.</li>
<li>Priority update now works when more than 16 gensets or more than 16 mains are present in a plant configuration.</li>
<li>PMS priority data is correct maintained internally in all genset controllers.</li>
<li>Breaker feedbacks are properly updated on the I/O status and the I/O setup page.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.04.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-04-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e6f9db51-4d7b-4d1e-a20d-2d09fa09da95</guid>
        <pubDate>2021-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.04.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.24.1</p>
<h3>New features:</h3>
<ul>
<li>New EIC measurement area included with data validation.</li>
<li>Support new J1939 priority for exhaust temperatures (CAT).</li>
<li>Extended #1230 G f&gt; 3 and #1260 G f&lt; 3 timers to 2000.0 [s].</li>
<li>Power ramps improved. 6- Feedforward control to suppress frequency and voltage disturbances in fixed power, reactive power control (in LFSM situations).</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>S nominal import/export set points are obsolete. Both are replaced by one S nominal per measurement area.</li>
<li>Maximum timer extended to 3200.0 s on a number of protections (AC, digital inputs, MPU, EIC).</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Translation now works even though no DU-2 is mounted AND only new language is written.</li>
<li>Deload TB before GB opens function works correctly in PEAK SHAVING.</li>
<li>PMS priority change via M-Logic or Modbus now works correctly.</li>
<li>df/dt now operates on the mains side measurements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.03.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e18c6791-aac8-4db3-9017-d788acce8dcf</guid>
        <pubDate>2021-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.03.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.24.1</p>
<h3>New features:</h3>
<ul>
<li>Two new General Purpose PID´s (GP-PID) 5 and 6 are added. Also added new parameters for all GPIDs (1 to 6) to configure the regulator set point.</li>
<li>Support of 3 x 2 A/Os on IOM 220/IOM 230 for GP-PID 1 to 6 is added.</li>
<li>Support for John Deere Stage V EIC protocol is added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>TCP/IP security update.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Limit events are added in M-Logic for Extended M-Logic Alarms.</li>
<li>"Fuel optimization" and "Fuel optimization + running hours" is now working when using percent values.</li>
<li>TDU is now able to change to BLOCK mode (requires TDU version 1.3.7.0).</li>
<li>Short circuit supervision (option T1) now includes PV and battery units connected (requires ASC-4 version 4.17.0).</li>
<li>EIC transmission rate stability is improved.</li>
<li>Default IP address is changed from 192.168.2.2 to 192.168.2.21 to match the TDU default address.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.03.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-03-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ef0f160e-72bf-4108-a839-056b50f1a6b8</guid>
        <pubDate>2021-09-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.03.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>Not UL approved version</p>
<p>PM compatibility: 1.24.1</p>
<h3><br />Corrections:</h3>
<ul>
<li>Freeze regulation during FRT now working correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.05.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-05-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">18789ab4-bccf-47d9-9a55-1f2bbcec4cfe</guid>
        <pubDate>2022-02-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.05.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.24.2</p>
<h3>New features:</h3>
<ul>
<li>Added supported ECU types.</li>
<li>NTP Support added.</li>
<li>Option A20: An external clearing time setting has been introduced in "Advanced Protection" under "Trip parameters".</li>
<li>Option A20: Sunspec model 707 and 708 now supported.</li>
<li>Option A20: Sunspec model 709 and 710 now supported.</li>
<li>Option A20: Sunspec model 703 now supported.</li>
<li>Option A20: Sunspec model 704 now supported.</li>
<li>Option A20: Sunspec model 705 now supported.</li>
<li>Option A20: Sunspec model 711 now supported.</li>
<li>Option A20: Q(U) VRef available in the DU-2, TDU and USW data tracer and trending.</li>
<li>Option A20: Sunspec model 702 now supported.</li>
<li>Option A20: Ability to disable option A20 functionality using menu 9101.</li>
<li>Option A20: Sunspec model 701 supported.</li>
<li>Option A20: Voltage ride through detection, regulation and protection (based on evaluation of cumulative time).</li>
<li>Option A20: Voltage ride through; Suspend regulation drop out time.</li>
<li>Option A20: Q(U): Autonomous adjusted VRef is now reset when the DG becomes parallel, when autonomous adjust is enabled, when Q(U) is enabled and when regulation mode is changed over to Q(U).</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Droop curve 1 now uses a more accurate busbar frequency measurement when configured for P(f) operation.</li>
<li>Option A20: Fixed cosphi setpoint resolution increased with a factor of 10. Backwards compatibility is not maintained.</li>
<li>Option A20: Q(U) open loop time response parameter can now be edited in 10th of a second.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>No ASC-4 PV irradiance sensor, could make AGC DG's provide inadequate power for mains power export.</li>
<li>Cosphi superior setpoints now work with only PV or Battery units on the busbar together with a AGC mains.</li>
<li>Volt var handling relative to Vref changed according to tech spec, esp. Autonomous Adj. Vref.</li>
<li>Time constant for Vref incorrectly interpreted as open loop time response.</li>
<li>When setting parameter #1204 Freq trip type to 'L1 and L2 and L3', the busbar frequency alarms would end up using the generator measurement.</li>
<li>Increased measurement inaccuracy at changing frequency could be seen infrequently.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.06.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-06-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">79447a56-11f7-4879-ab4d-6351520a3a01</guid>
        <pubDate>2022-02-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.06.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PMS compatibility: 1.25.0</p>
<p><strong>New features:</strong><br />1- Scania EMS2 S8 Urea/DEF level added to delta alarms.<br />2- PMS function: block breaker in closed position when one or two faults occur added (menu 8860 and 8870).</p>
<p><strong>Finetuning:</strong><br />1- TDU can now show the DEF level when Scania EMS2 S8 is used as engine I/F.<br />2- 32-bit EIC values is shown on new modbus (function 4, reg 26000).<br />3- IOM works with all supported engine protocols.<br />4- AMF Overlap is working when modeshift is used.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.07.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-07-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a69151fe-51d4-43fb-acf5-1dd21a4de336</guid>
        <pubDate>2022-07-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.07.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.25.0</p>
<h3>New features:</h3>
<ul>
<li>EIC: Added Cummins KTA19, Deutz EMR5 Stage V and Perkins Stage V.</li>
<li>EIC: Added configurable TSC1 transmission rate and checksum/counter for Generic J1939.</li>
<li>EIC: Enable/disable alarm ack. via J1939 (DM11).</li>
<li>Extended RMI 20 Points in multi-inputs.</li>
<li>Extended mA 17 Points in multi-inputs.</li>
<li>M-Logic flags for Enable / Disable for spinning reserve added.</li>
<li>Dynamic Frequency Response mode for controlling frequency in situations with excessive amounts of PV-power, added for single generator.</li>
<li>Extended EIC wait to start (preheat) support. Introduced M-logic command to inhibit wait to start.</li>
<li>EIC: Added support of Scania EMS2 S8 HC Evaporation Status in M-logic and view.</li>
<li>Selection of Gov reference for ECU added in menu 15100. Select between nominal frequency or nominal rpm.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>N + X ON/OFF via digital input or M-Logic corrected.</li>
<li>EIC autoviews is not deleted doing power up.</li>
<li>Q(U) U-shift regulation could assign a Q reference different than 0 to the AVR regulator when the voltage was inside the deadband. This has been fixed.</li>
<li>GOV output was sometimes raising to 100% when GB was closed with static sync. This has been fixed.</li>
<li>A genset will now charge a battery with the correct amount during negative PMS setpoints.</li>
<li>A genset will now calculate the correct power reference if a battery operating as a energy source is charging from excess PV power.</li>
<li>A running DG with its GB closed could react to invalid power management data when changing from a single DG application to a standard application.</li>
<li>A mains could issue a start signal to DGs based on invalid power management data when a BTB was powercycled.</li>
<li>Idle run stops engine correctly when using Low speed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.08.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-08-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">45227341-ff4e-499c-8ace-e1e6a7166ca2</guid>
        <pubDate>2022-11-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.08.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.28.0</p>
<h3>New features:</h3>
<ul>
<li>Support for DEIF DVC 350.</li>
<li>Support for ASC-4 SOLAR in plant management (G7) added.</li>
<li>Oneshot logic in M-Logic.</li>
<li>CBE re-run failure alarm added. Menu 2230.</li>
<li>PMS Mode update from ASC supported.</li>
<li>Automatic adblue refill: System for monitoring and start/stop filling a diesel exhaust fluid tank.</li>
<li>Fluid fill: System for monitoring and start/stop filling a fluid tank.</li>
<li>Virtual event toggles when using Modbus. Created new virtual switch events that stay high when configured high in Modbus and M-Logic.</li>
<li>Easy connect compatibility with ASC 150 Storage.</li>
<li>New relay types 'Modbus control relay ON' and 'Modbus control relay OFF' for all digital outputs.</li>
<li>Created more CIO 308 selections for external transducers: 2.14, 3.14, 2.17, 3.17, 2.20, 3.20.</li>
<li>Selection of Q calculation method added in JUMP menu 9132.</li>
<li>EIC: Added FPT Stage V SPN/FMI fault codes.</li>
<li>EIC: Added support of KWG ISO5 isolation monitor.</li>
<li>EIC: Added support of Cummins CM2850.</li>
<li>EIC: Added support of Cummins CM2350.</li>
<li>EIC: Added support of Cummins CM2880.</li>
<li>EIC: Added FPT Stage V Turbo heat protection as M-Logic event.</li>
<li>EIC: Added Scania S8 safe regeneration signal as M-Logic output.</li>
<li>EIC: Added safe regeneration status as M-Logic event.</li>
<li>EIC: Added EIC Fan speed (SPN 986) as PID output. Fan speed feedback (SPN 1639/975) added as input to delta alarms and PID.</li>
<li>Added support for 5 CIO 116, 208 and 308.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Busbar block handling in PMS now allowed to let the system (DG, MAINS etc) run even though any breaker has position failure.</li>
<li>EIC: Scania S8 is now showing regeneration active symbol when manual regeneration is active.</li>
<li>The low speed digital input and idle start/stop timers can now be used together.</li>
<li>Configurable averaging of AC measurements for read-out on display and Modbus in menu 9260.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected an issue where two or more DGs could end up with the same priority.</li>
<li>#7804 DAVR bias range now works correctly for DVC 550 and D550 DAVRs.</li>
<li>Update of modes on all controllers in a PMS application has been made more robust.</li>
<li>PMS island load sharing would not work correctly when #9030 Scaling was set to something other than default. This has been corrected. PMS asymmetric load sharing in island also corrected when using a different scaling than default.</li>
<li>In rare cases connected DGs could trip and stop, when units disconnected from PM reconnects.</li>
<li>Diagnostics timer (#6701) is now working.</li>
<li>FMS scalings corrected.</li>
<li>CBE re-run no longer closes generator breaker directly on black busbar with cooldown control set to excitation ON.</li>
<li>Configuration of outputs 8-14 is now set correctly after power cycle.</li>
<li>PID force min/max is now working when offsets are used.</li>
<li>Option A20: Permit service ramp with 0 ramp steps corrected.</li>
<li>Corrected that Viewline 3 was flickering when external power set point is active. This is also present when the system is on power management.</li>
<li>BTB dividing sections sequence is now working correctly in AMF situations.</li>
<li>The power ramp module will now initiate its ramp faster.</li>
<li>MAINS unit power measured with open MB no longer added to available power in DG.</li>
<li>With feedforward enabled, the regulator would go to maximum or minimum when opening the GB and thereby causing the busbar to be black.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.08.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-08-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">00953578-6363-42bf-9b8a-38134e902eba</guid>
        <pubDate>2022-12-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.08.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.28.0</p>
<h3>Corrections:</h3>
<ul>
<li>AGC-4 Mk II able to connect to TDU with software version 1.3.10.1-r2679.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.09.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-09-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">465ec76b-5db4-4829-b014-c322147532b4</guid>
        <pubDate>2022-12-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.09.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.28.0</p>
<h3>New features:</h3>
<ul>
<li>EIC: Add support of Caterpillar ADEM6.</li>
<li>Two new EIC aftertreatment alarms has been added: "High SOOT warning" and "High SOOT shutdown".</li>
<li>EIC: Update Iveco Stage V with new alarms, m-logic events and symbol handling.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>M-Logic Event for "CBE excitation start level (rpm) reached" added.</li>
<li>Changed overload alarm 5 (channel 1490) to low load alarm.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Hz/V OK alarm timer (4560) no longer started in CBE, when cooldown is active, and excitation is removed.</li>
<li>EIC: LiveLink is now working when used with PSI.</li>
<li>Sunspec model 701: LLV and LNV data points added for compliance.</li>
<li>Sunspec model 702: WChaRteMaxRtg and VAChaRteMaxRtg data points added for compliance.</li>
<li>Sunspec model 704: VarSetPri data point added for compliance.</li>
<li>Sunspec model 705: Crv.Pri data point added for compliance.</li>
<li>Sunspec model 707: Curve expanded from two to five data points for compliance.</li>
<li>Sunspec model 708: Curve expanded from two to five data points for compliance.</li>
<li>Sunspec model 709: Curve expanded from two to five data points for compliance.</li>
<li>Sunspec model 710: Curve expanded from two to five data points for compliance.</li>
<li>Sunspec model 711: Changes to values are now effectuated in the controller on curve adaptation.</li>
<li>The enter service ramp would activate when coming back inside the P(f) droop deadband. This has been corrected.</li>
<li>A change in the P(f) kOF and kUF parameters are now effectuated right away.</li>
<li>IEEE Volt-var is now limited by nameplate reactive ratings.</li>
<li>Legacy fixed cosphi(#7052) was not limited by the #2811 AVR limiting parameter when option A20 was active.</li>
<li>IEEE constant power factor parameter now limited to 0.700C ... 0.700I.</li>
<li>Corrected issue where specific PV spinning reserve values in a plant with a battery and DGs could cause genset start/stop looping.</li>
<li>Corrected issues where PV spinning reserve values in a plant with a battery, PV, Mains and DGs would not start and stop the gensets at the correct available power.</li>
<li>Busbar emulation improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.09.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-09-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d5d63ce0-1ec6-4af1-a76c-38a17becf1cf</guid>
        <pubDate>2023-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.09.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>Corrections</h3>
<ul>
<li>The mains failure hysteresis is now included in the response if one of the OK timers is running at the same time as the OK condition is reached.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ad2e2a55-8280-487e-9605-251721e9b3da</guid>
        <pubDate>2023-03-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.10.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>New features</h3>
<ul>
<li>EIC: Added new view to check status of regeneration request from ECU.</li>
<li>EIC: Added new M-Logic events to Deutz EMR5 Stage V.</li>
<li>EIC: Added support for Kohler KDI 3404 Stage V.</li>
<li>EIC: Added support for Yanmar Stage V.</li>
<li>EIC: Added support for Scania S8 Industrial.</li>
<li>Created Modbus addresses to read state of prioritised inputs for general purpose PIDs.</li>
<li>Added tree structure for translations.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>EIC: Updated FPT Stage V protocol to support new symbols.</li>
<li>EIC: Inhibit DM1 lamp alarm if engine is not running and not valid SPN is available.</li>
<li>M-Logic and digital input function for safe regeneration.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Changing between an A10 or A20 specific AVR regulation mode and a legacy AVR regulation mode is now handled correctly by the switching ramp timer.</li>
<li>The mains failure hysteresis is now included in the response if one of the OK timers is running at the same time as the OK condition is reached.</li>
<li>TB continues to be closed when a PV is the only power source connected to the busbar.</li>
<li>CAN transmit on EIC line cannot be provoked to stop in certain situations.</li>
<li>Corrected issue where PV did not produce the correct Q based on its capability curve and P/Q cap. limit in PMS applications.</li>
<li>Power meters in application supervision no longer shown on external BTB.</li>
<li>Corrected issue where PV did not produce the correct Q to achieve the requested grid PF when the plant operates with a voltage based droop and the mains voltage changes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">51f224cf-2c70-4b0e-9690-a8c8fe980864</guid>
        <pubDate>2023-03-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.10.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>Corrections</h3>
<ul>
<li>During a transfer of ground relay, a DG that was not suited for closing its ground relay, could briefly close it and then quickly open it again. This has been fixed.</li>
<li>"DVC controls" OFF only sent few initial data values after loss of communication.</li>
<li>Incorrect DAVR alarm is no longer active on a redundant unit.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.10.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-10-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">39132c55-7f41-4cf9-917b-5366aefa616b</guid>
        <pubDate>2023-05-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.10.2</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.29.0</p>
<h3>Corrections</h3>
<ul>
<li>#7293 f offset meas was off by a factor of 10 internally.</li>
<li>Power ramp 1 automatic shift to power ramp 2 is working again.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e3b095b0-b1c0-4d8a-aa0c-6d6e6ba5a837</guid>
        <pubDate>2023-07-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.11.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.0</p>
<h3>New features</h3>
<ul>
<li>M-Logic: added M-Logic event counters to the counters tab. This includes: no timer, a timer that resets the counters, and a timer that resets each individual count per counter.</li>
<li>Multi-start switch to minimum number to run right after first GB closes via configuration in menu 8360.</li>
<li>LD stop without delay available via configuration in menu 8350.</li>
<li>EIC: Added M-Logic outputs to inhibit DM1 protection, yellow, red and malfunction lamp alarms.</li>
<li>EIC: Added VTAs on EIC malfunction and protection alarms.</li>
<li>EIC: Added auto acknowledge feature for engine comms alarm, channel 7570.</li>
<li>Added auto acknowledge feature for channel 7520, Ext. comm. error.</li>
<li>Added new Modbus area for alarm list monitoring.</li>
<li>Added functionality to ignore certain SPN rules from USW.</li>
<li>Support of PMS lite added.</li>
<li>Support of CAN-Share added.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>EIC: FPT Stage V low oil pressure alarm can only be triggered while running. Added new M-Logic event for DEF warnings.</li>
<li>Manual PMS priority update via digital input or M-Logic is only allowed to occur on one DG within 10 seconds.</li>
<li>Possible to add special descriptions of specific SPN/FMI combinations for Volvo Penta EMS2 and EMS 2.4.</li>
<li>Possible to add second ECU for Volvo Penta EMS2 and EMS 2.4.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Power ramp 3 logic was not based on the droop curve 1 dead band settings.</li>
<li>When using droop curve 1 and frequency offset, power ramp 3 is activated instead of power ramp 2 if the frequency is more than or less than the dead band. This has been fixed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1c7ccec6-01d5-4dc6-9128-71c2a31613f2</guid>
        <pubDate>2023-07-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.11.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.0</p>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue that could cause a discontinuity in the reference for the AVR regulator when changing #2823 'Q ramp enable from any mode' to 'Time constant'.</li>
<li>Fixed an issue where ramp 4 would not be prioritised when the genset reconnected after being disconnected by the mains sync inhibit function. Added a variable delay for the activation of power ramp 3 when the grid frequency returns inside the frequency droop dead band (droop curve 1).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ed936715-e1f9-4c7f-aa3c-3ef403caad41</guid>
        <pubDate>2023-09-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.11.2</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.1</p>
<h3>Corrections</h3>
<ul>
<li>The Q ramp function now works for option A10 'Variant F: Superior' applications.</li>
<li>The battery log is now correctly updated when the relay output of the battery test function is set to 'limits'.</li>
<li>Even if the DAVR control parameter was set to OFF, connecting to a Nidec D550 without the T3 option would generate an 'Illegal DAVR' alarm. This has been fixed.</li>
<li>PMS lite: The #8540 'Available power' alarm was incorrectly calculated. This has been fixed.</li>
<li>PMS lite: The #8511 'ID not available' alarm was activated when changing from a manually chosen ID to a different but free ID. This has been fixed.</li>
<li>Unable to cancel the start sequence between start attempts in semi-auto mode. This has been fixed.</li>
<li>In a LTO multi-start setup, a number of multi-start gensets did not always start to synchronise at the same time. This has been fixed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.11.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-11-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0ff9f294-5cf4-4f18-a385-495bd8602f4f</guid>
        <pubDate>2023-09-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.11.3</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.30.1</p>
<h3>Corrections</h3>
<ul>
<li>RMB T4: When back-synchronising to the mains, the display automatically shows the synchroscope. The buzzer in the RMB box also sounds when the static synchronisation check is okay.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b199add9-1807-4c73-8928-420c1441974e</guid>
        <pubDate>2023-10-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.12.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.32.0</p>
<h3>New features</h3>
<p>• EIC: Added support of Weichai E6.<br />• EIC: Added support of Iveco Stage V NEF67.<br />• EIC: Added support of Cummins CM2358.<br />• Added fuel fill check alarm in M-Logic.<br />• Added new shutdown override inhibit. If shutdown override is active and an alarm with the inhibit is activated, the alarm is shown on the display, but the fail class is not used.<br />• Added H2G fuel cell control.</p>
<h3>Changes</h3>
<p>• EIC: Added GTACP (0xFE05, SPN2452/2460) to Caterpillar generic and Perkins generic.<br />• All alarms are now by default configured with the shutdown override inhibit except for #1130 I&gt;&gt; 1, #3490 Emergency STOP, #4510 Overspeed 1, #4520 Overspeed 2, and #7600 EIC overspeed.</p>
<h3>Corrections</h3>
<p>• PMS priority update in 32DG application now working correctly.<br />• If a DG in PMS has an active "missing all units" alarm, it will now shut down if its auto start signal is deactivated.<br />• Peak shaving working again. Compromised in version 1.17.0.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.12.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-12-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4d59c118-71b7-4608-b830-315a374290fa</guid>
        <pubDate>2024-02-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.12.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.34.0</p>
<h3>Corrections</h3>
<ul>
<li>BTB deload could block a DG from executing a load-dependent stop sequence.</li>
<li>Change of ID to Run with Run one MAINS during active LTO is now working correctly.</li>
<li>Power capacity is now requested correctly in an AMF application to the start required number of DGs and close the TB.</li>
<li>PMS lite: Baudrate can now be changed without power cycle or manual CAN interface reset (ON/OFF in CAN interface).</li>
<li>Mains failure hysteresis was overruled in situations where no emergency sources were available. This has been fixed. Furthermore, the precision of the hysteresis calculations has been improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c0efb8a6-86a6-4309-b5f3-17fa4dad7048</guid>
        <pubDate>2024-06-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.13.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.34.0</p>
<h3>New features</h3>
<p>&nbsp; &nbsp;1- Fuel optimisation further optimised in more applications, including PV and battery.<br>for applications including PV and battery.<br>&nbsp; &nbsp;2- Extended command timers with week options &nbsp;(parameters 6951-6954).<br>&nbsp; &nbsp;3- Regulation (GOV and AVR) and load-share (P and Q) now available via external CAN module IOM 2xx.<br>&nbsp; &nbsp;4- EIC: Added six new engine protocols.<br>&nbsp; &nbsp;5- Mains controller: Added static synchronisation.<br>&nbsp; &nbsp;6- GENSET: Added digital load sharing with third-party controllers in SEMI mode.<br>&nbsp;&nbsp;</p>
<h3>Changes</h3>
<p>&nbsp; &nbsp;1- Spinning reserve stop hysteresis calculation is now based on the nominal power on busbar after next DG to stop.<br>&nbsp; &nbsp;2- Yanmar Stage V: Regeneration request sequence now configurable in the USW. 'Regeneration needed' and 'Regeneration active' icons will now be displayed if the states are active in the ECU. The regeneration inhibit command has been inverted as per the specification.<br>&nbsp; &nbsp;3- Analogue loadshare extended with separate parameter for Qset as DC level at 100% kvar. New parameter in menu 6393. Menu 6390 moved to 6391 and menu 6380 moved to 6392.<br>&nbsp; &nbsp;4- EIC: Additional measurements for 'Engine knocking' and 'Spark-ignition' added to Cummins.<br>&nbsp; &nbsp;5- The block fail class now also blocks the MB on sequence. It is therefore aligned with how other breakers are handled in regards to the block fail class.<br>&nbsp; &nbsp;6- EIC: Updated Deutz Stage V to support EPA1/2/3.<br>&nbsp; &nbsp;7- EIC: Updated FPT Stage V/Iveco NEF67.<br>&nbsp; &nbsp;8- EIC: SPN ignore - Icons are not shown if SPN/FMI combi is ignored. However, it is possible to get data about the fault in DM1 log.<br>&nbsp; &nbsp;9- GENSET: Added new status text and infomessage, making it more visible to the user when the GB open failure alarm is blocking a generator stop.</p>
<p>&nbsp;</p>
<h3>Corrections</h3>
<p>&nbsp; &nbsp;1- Auto calculation multistarts with fuel optimisation, now works before the TB is closed.<br>&nbsp; &nbsp;2- Fuel pump and fluid pump can now use CIO 308 inputs. Fuel pump output menu has been removed as it is no longer used.<br>&nbsp; &nbsp;3- Fixed wrong values for temperature-based values on the display.<br>&nbsp; &nbsp;4- P(U) droop curve deadband settings was used with a factor 10 too much. This has been fixed.<br>&nbsp; &nbsp;5- MAINS with Ext MB/ATS control working again. Bug introduced in version 6.09.0.<br>&nbsp; &nbsp;6- MAINS stand-alone with CAN-bus OFF can now close MB after power cycle.<br>&nbsp; &nbsp;7- GENSET: Enter black busbar protection not working as intended in CanShare and PMS lite. This has been fixed.<br>&nbsp; &nbsp;8- Multiinput for VDC, PT100 and PT1000 is now scaled correctly in both display and USW.<br>&nbsp; &nbsp;9- ROCOF (df/dt) alarm available in M-Logic events.<br>&nbsp; &nbsp;10- MAINS-controlled Fixed for Imp/Exp with low MB power caused unstable PF in GENSETs. This has been corrected.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.13.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-13-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">db6a68d8-59c5-4a8a-b7f6-467a43841070</guid>
        <pubDate>2024-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.13.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.34.0</p>
<h3>Corrections</h3>
<p>&nbsp; &nbsp;1- Corrected unit restarting if Profibus option is selected.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f0a76eb-e21c-424a-8877-2fbdbbe21bf4</guid>
        <pubDate>2024-09-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.14.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p><strong>IMPORTANT:</strong> This software requires USW-3 version 3.60.2 with PDB revision 10901 or higher.</p>
<p>PM compatibility: 1.35.1</p>
<h3>New features:</h3>
<ul>
<li>Added new parameter 8154 "Gnd priority". This parameter controls whether gensets or batteries should have ground relay active when their nominal sizes are equal. This parameter only has an effect if there are ASC150 Storage controllers with ground relay functionality enabled.</li>
<li>EIC: Added buzzer output for Baudouin CPCB IV.</li>
<li>BTB controllers can now be statically synchronized.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Text handling updated (this requires new USW3 for connection).</li>
<li>EIC: Added M-Logic command flag to give control if preheat to Volvo EMS.</li>
<li>EIC: Kohler KDI3404 - Added support of second ECU.</li>
<li>EIC: Implemented Yuchai fault codes.</li>
<li>GENSET: Nominal set 5 and 6 added in menu 6800 and 6810.</li>
<li>GENSET: Averaged P and Q, which were introduced in version 6.08.0, can now be used for load-sharing. Use jump menu 9281.</li>
<li>GENSET-MAINS: Averaged P and Q, which were introduced in version 6.08.0, can now be used for regulation and ramping. Use jump menu 9282.</li>
<li>GENSET-MAINS-BTB: Averaged P, Q and S, which were introduced in version 6.08.0, can now be used for power management. Use jump menu 9283.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue of not starting unit when installing Profibus.</li>
<li>Fix emulated load from ASC variants not being added correctly.</li>
<li>PMS redundant with local mode update (8022) corrected. The redundant unit follows the preferred unit.</li>
<li>Fixed an issue where language write failed.</li>
<li>Service timers 3 and 4 now persist between power cycles of the controller.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">eb74acc4-b553-431e-ba43-29cff6e0dba4</guid>
        <pubDate>2024-12-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.15.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p><strong>USW version required: 3.61.0<br>TDU version required: 1.4.3.0</strong></p>
<p>PM compatibility: 1.35.1</p>
<h3>New features</h3>
<ul>
<li>CIO 308 inputs set up as binary types can now be used the same way as CIO 116 digital inputs.</li>
<li>EIC: Added support for Wise13.</li>
<li>EIC: Added support for Caterpillar ADEM5.</li>
<li>EIC: Added support for YC-ECU-A including new delta alarms and views.</li>
<li>Added M-Logic commands for enabling and disabling parameters 7502 Comm. bus control f, 7503 Comm. bus control U, 7504 Comm. bus control cosphi, and 7505 Comm. bus control Q.</li>
<li>Added M-Logic commands "Force Gen Start in AUTO" and "Force GB ON in AUTO" in the DG controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>EIC: Added new M-Logic events and AT texts to John Deere Stage V.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>GENSET: Corrected an issue with calculating the load impact for single DGs in emulation.</li>
<li>GENSET: Soft voltage recovery and I stator limitation now works regardless of the configuration of the DVC 550/D550 and DVC 350.</li>
<li>MAINS: 'Mains power' measurement in datatracer now scales correctly based on the 9030 Scaling parameter.</li>
<li>EIC: Added Yanmar PJ: X11 engine protocol.</li>
<li>M-Logic commands 'Inh. start button', 'Inh. stop button', 'Inh. GB/TB button' and 'Inh. MB button' can now be read by the TDU.</li>
<li>Corrected an issue that caused parameter 2024 Sync. dUMin to be disregarded as a lower limit for dynamic synchronisation of the voltage if parameter 2023 Sync. dUMax was numerically smaller.</li>
<li>Assigning an analogue output parameter to an already assigned analogue output would fail. Now the newly assigned parameter will be assigned as the analogue output and the parameter the output was previously assigned to will be cleared.</li>
<li>CIO 308 ID 4 and 5 can now also be used for remote sensing P, Q and U. Fixed an issue for remote sensing with the mains controller, where the wrong transducer min/max was used for U remote sensing.</li>
<li>GPPIDs can now be used with all IOM CAN ID outputs again. The parameter for specifying which IOM to use for GOV, AVR and load share can be found in the 'IOM configuration' tab of the 'ECU &amp; D-AVR configuration' page.</li>
<li>Corrected PMS redundant with BTBs so the redundant unit follows the preferred unit.</li>
<li>The synchronisation module now correctly determines when to close the breaker during dynamic synchronisation in configurations where the breaker close time is high (parameters 2025 and 2026).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.15.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-15-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">636bc81e-ad67-4d48-9fff-b5a6066a2473</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.15.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.60.2</li>
<li>TDU version required: 1.4.3.1</li>
</ul>
<p>PM compatibility: 1.35.1</p>
<h3>Corrections</h3>
<ul>
<li>MAINS: In emulation, the busbar OK status is now purely based on emulated measurements and not the state of the mains breaker.</li>
<li>Fixed unintended relay hazard causing certain functions not to be configured.</li>
<li>Status texts were sometimes not correctly shown on the TDU.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bc3e538b-e0bf-4caf-bf57-3c3489f71adb</guid>
        <pubDate>2025-03-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.20.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.61.0 pdb 11353</li>
<li>TDU version required: 1.4.4.0</li>
</ul>
<p>PM compatibility: 1.40.0</p>
<h3>New features</h3>
<ul>
<li>Added new Modbus area with application configuration information from addresses 36000 to 36041 with function code 04H.</li>
<li>Added new 32-bit Modbus register with active power load information from addresses 765 to 766 with function code 04H.</li>
<li>EODev H2G fuel cell has been updated with SOC limits for delta analogue alarms.</li>
<li>EODev H2G fuel cell has been updated with new RECHARGE mode and a new M-Logic output for existing RECHARGE mode.</li>
<li>EODev H2G fuel cell has been updated to transmit available power over EIC CAN communication.</li>
<li>Added support for new M4 Mk III board.</li>
<li>EIC: Added support for Yanmar gas 4G.</li>
<li>EIC: Added support for Scania S6 industrial.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>SEMI renamed to MANUAL.</li>
<li>MANUAL renamed to NO REGULATION.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Improved latency on reception of PMS telegrams.</li>
<li>Fixed handling of PMS telegrams when only main processor is restarted.</li>
<li>Fixed rare sporadic error on RS-485 communication.</li>
<li>GENSET: M-Logic output to change PMS priority selection (#8031) to fuel optimization was missing.</li>
<li>In the USW parameter list, mains and BTB controllers would show that an inhibit was applied, even though it was not. This has been fixed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">55243e0b-7f97-4d1c-960b-9c7ff38d8444</guid>
        <pubDate>2025-05-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.21.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.0</li>
<li>TDU version required: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>New features</h3>
<ul>
<li>EIC: Added many new SPN texts for DM1 log.</li>
<li>EIC: Added fuel rate alarm based on active power.</li>
<li>GENSET: Added counter for number of successful generator starts.</li>
<li>EIC: Added Guascor GCS-e ECU protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>M-Logic: Renamed 'Virtual toggle' to 'Virtual event' and 'Virtual switch' to 'Virtual toggle'.</li>
<li>Virtual events work the same on Modbus and M-Logic. The output of the virtual event will follow the input of the virtual event.</li>
<li>Virtual toggles work the same on Modbus and M-Logic. If the input of the virtual toggle goes high, the output changes state once.</li>
<li>Added parameter 7075, "Mains Fail Assumption", which enables the Mains controller to assume that the mains have just recovered at start-up, allowing it to run the OK timers.</li>
<li>EIC: Keyswitch (#15050) is available for J1939 protocols.</li>
<li>Updated EODev H2G fuel cell transmission rate has been to 20 ms for I, P and Q measurements.</li>
<li>EIC: Added TSC1 to YC-ECU-A.</li>
<li>EIC: Changed crankcase pressure (SPN 101) to kPa unit in delta alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>GENSET: The frequency/voltage regulation mode is no longer dependent on the frequency detection level when running with the GB closed.</li>
<li>GENSET: Gen stop + GB Off M-Logic command can now stop the genset during the start sequence.</li>
<li>If breaker is not used, the associated position feedback are cleared so they can be used for something else. Also added protection against overwriting position feedback assignment when the associated breaker is setup.</li>
<li>M-Logic virtual toggles (previously named switches) can now be read over Modbus.</li>
<li>GENSET: If idle run was active, RMI oil pressure alarms would be active before it was detected that the engine was running. This has been changed so that the engine must be running before the alarms can be active.</li>
<li>Droop curve 2 configured with power factor output now works properly again.</li>
<li>GENSET: Regulation mode will correctly be set to fixed power P/Q control when PMS isochronous master is active in power management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.21.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-21-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf467054-888a-4d3f-81af-fb50004468e7</guid>
        <pubDate>2025-06-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.21.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.0</li>
<li>TDU version required: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>Corrections</h3>
<ul>
<li>Recognizing option M15.6 working again. Compromised in version 6.20.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.22.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-22-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b8bd2343-46a0-4047-b9b3-555696bc7946</guid>
        <pubDate>2025-08-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.22.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.1 (PDB 11714)</li>
<li>TDU version required: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>New features</h3>
<ul>
<li>GENSET: Added support of digital loadvsharing with SmartGen in MAN mode.</li>
<li>GENSET: Added support of digital load sharing with ComAp in MAN mode.</li>
<li>EIC: Added NPS Hydrogen ECU protocol.</li>
<li>EIC: Added Volvo Penta D12 protocol.</li>
<li>EIC: Added support of Kubota Stage V.</li>
<li>EIC: Added Cummins QSK78 protocol.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where Droop Curve 2 did not calculate cos phi droop correctly when leaving the deadband with a cos phi of less than 1.0.</li>
<li>Fixed an issue where transfer of ground relay from deloaded genset to battery did not overlap.</li>
<li>EIC: Added SPN 5579 to delta alarms.</li>
<li>Racked-out breaker can now be used when the controller is in BLOCK mode.</li>
<li>GENSETs forced to analogue load sharing in a PMS setup with MAINS can now back-synchronise to the MAINS when directed.</li>
<li>BTB: Fixed an issue where active power measurement was incorrectly displayed as reactive power measurement in application supervision.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.23.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-23-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b281e5c4-b3df-4bac-8084-9ff9559d1e9d</guid>
        <pubDate>2025-10-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.23.0</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<h4>AGC-4 Mk II release history from version 6.00.0</h4>
<ul>
<li>Version 6.23.0 (based on version 6.22.0)</li>
<li>USW version required: 3.64.0</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New features</h3>
<ul>
<li>EIC: Added protocol Kingbang.</li>
<li>EIC: Added protocol SDEC F31.</li>
<li>EIC: Added protocol SDEC F36.</li>
<li>EIC: Added protocol Hatz.</li>
<li>PMS Lite: Added support for up to 254 controllers. Version increased to 5 and is not backwards compatible with earlier versions.</li>
<li>PMS Lite: Added support for BUS TIE breaker controllers in MANUAL mode.</li>
</ul>
<p>&nbsp;</p>
<h3>Changes</h3>
<ul>
<li>Modbus: Added S (apparent power) and cos phi for all Power Management IDs to Modbus.</li>
</ul>
<p>&nbsp;</p>
<h3>Corrections</h3>
<ul>
<li>MAINS: Fixed an issue where Mains OK Delay f and U timers were always overruled when only batteries in plant.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.23.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-23-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bb05b671-d16e-4949-b9a5-67ef0328e75a</guid>
        <pubDate>2025-11-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.23.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.64.0</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Compact breaker: The breaker OFF relay now closes only once and remains closed for charging the spring.</li>
<li>Ground relay: Fixed an issue where the ground relay was always tripped by the redundant unit.</li>
<li>EIC: DM2, DM3, and DM11 are now displayed correctly using DU-2.</li>
<li>Spinning reserve: Fixed an issue where parameter 8930 “Spinning reserve” was enabled in a power management setup by accident after power cycling a single unit.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.13.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-13-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4596ee42-77f4-4413-87c7-65cdb16a29b9</guid>
        <pubDate>2026-01-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.13.2</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p>PM compatibility: 1.34.0</p>
<h3>Corrections</h3>
<ul>
<li>Support for M4 Mk III hardware.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software &#x2013; v6.30.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/6-30-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">97b82fea-8f05-4e26-92f6-bcc6f53e2b4c</guid>
        <pubDate>2026-04-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software</category>
        <category domain="version">6.30.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<h3>Key new features</h3>
<h4>Energy &amp; Power Management</h4>
<ul>
<li>Support for negative fixed power setpoints when operating in parallel with batteries (fixed import power).</li>
<li>New MB soft open function, enabling controlled deloading before breaker opening in manual mode, with timeout protection.</li>
<li>Added reactive power load reporting via a new 32-bit Modbus register (FC04, addresses 767-768).</li>
</ul>
<h4>Engine &amp; Protocol Support</h4>
<p>New engine communication protocols added:</p>
<ul>
<li>Farizon</li>
<li>Wise10</li>
<li>Kirloskar</li>
</ul>
<p>Extended J1939-75 support with additional transmitted data:</p>
<ul>
<li>Ambient temperature</li>
<li>DEF tank volume</li>
<li>Heater active status</li>
</ul>
<ul>
<li>Added fuel consumption data support for Cummins PGI.</li>
<li>Added transmission support for John Deere Stage V, PGN 0xFDC7.</li>
</ul>
<h4>Sensors &amp; I/O</h4>
<p>New predefined multi-input curves:</p>
<ul>
<li>CAT sensor - water temperature</li>
<li>CAT sensor - GP pressure (supported on terminals 102, 105, and 108)</li>
</ul>
<ul>
<li>Added configurable RX CAN telegrams.</li>
<li>New inhibit commands for pump functions available in M-Logic.</li>
</ul>
<h3>Improvements &amp; behavioural changes</h3>
<ul>
<li>Automatic conversion of multi-input alarm setpoints and curves when changing engineering units.</li>
<li>Improved fault code texts and pre-lube logic for Yanmar X11 engines.</li>
<li>Improved test mode behaviour - mode changes no longer cancelled active test mode.</li>
<li>Improved Modbus mains P/Q values in PMS setups.</li>
</ul>
<h3>Corrections &amp; fixes</h3>
<ul>
<li>Improved frequency recovery handling for Volvo Penta engines during large load steps.</li>
<li>Fixed a PMS lite issue where the AVR could use an incorrect Q load-sharing setpoint.</li>
<li>Fixed a breaker-to-breaker start-up scenario that could incorrectly request DG starts.</li>
<li>Fixed issues with:
<ul>
<li>Power ramp handling during FRT events</li>
<li>Active power ramp cancellation</li>
<li>Multi-input mA signals used in general-purpose PIDs</li>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software UL approved &#x2013; v6.02.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-ul&#x8BA4;&#x8BC1;/6-02-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e5ca4a4-363c-40b2-a6a5-198bc4b6b253</guid>
        <pubDate>2021-06-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software UL approved</category>
        <category domain="version">6.02.1</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p><strong>This software is UL approved!</strong></p>
<p>PM compatibility: 1.23.0</p>
<h3>Corrections:</h3>
<ul>
<li>Plant management Group Tie redundancy is improved in AUTO and ISLAND plants to secure groups without a start signal to start and stop properly when in need of a redundant unit.</li>
<li>Corrected the text for IP, subnet, gateway.</li>
<li>Corrected that alarm and battery logs where not shown correctly when the number of entries reached maximum.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 AGC-4 Mk II Application Software UL approved &#x2013; v6.05.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-agc-4-mk-ii-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-ul&#x8BA4;&#x8BC1;/6-05-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8a26a1c7-a31f-4415-a577-575e75c06749</guid>
        <pubDate>2023-09-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 AGC-4 Mk II Application Software UL approved</category>
        <category domain="version">6.05.5</category>
          <category domain="product">AGC-4 Mk II</category>
        <content:encoded><![CDATA[
<p><strong>This software is UL approved!</strong></p>
<p>PM compatibility: 1.24.2</p>
<h3>Corrections</h3>
<ul>
<li>Changing between an A10 or A20 specific AVR regulation mode and a legacy AVR regulation mode is now handled correctly by the switching ramp timer.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ALC Application Software series 4.x &#x2013; v4.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-alc-4-&#x8F6F;&#x4EF6;/4-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">305943a3-b3b7-4244-8170-f347891b05cc</guid>
        <pubDate>2021-06-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ALC Application Software series 4.x</category>
        <category domain="version">4.13.0</category>
          <category domain="product">ALC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.23.1.</p>
<h3>New features:</h3>
<ul>
<li>Load-groups are now able to close on a dead busbar in AUTO mode. This can be activated via Modbus commands, Modbus control register or M-Logic.</li>
<li>Eight low frequency alarms are added. These are placed in menus 1000-1070.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Faster execution of load-groups closing.</li>
<li>Four output relays on terminals 118-119, 118-120, 121-122 and 123-124 are now configurable.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ALC Application Software series 4.x &#x2013; v4.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-alc-4-&#x8F6F;&#x4EF6;/4-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9906e67c-6f36-42b0-a07a-afa5c78526c9</guid>
        <pubDate>2020-11-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ALC Application Software series 4.x</category>
        <category domain="version">4.12.0</category>
          <category domain="product">ALC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.21.0.</p>
<h3>New features:</h3>
<ul>
<li>   Configurable amount of units for triggering Fatal CAN Error alarm is added in menu 8800.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>   Support of ASC-4 redundancy.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>   Corrected that selection of ‘Number of PMS units’ and ‘PMS CAN baud rate’ previously would only work with default settings. and an issue with redundancy.</li>
</ul>
<div></div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ALC Application Software series 4.x &#x2013; v4.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-alc-4-&#x8F6F;&#x4EF6;/4-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d6f37e2e-d878-4226-b872-47d404f1b371</guid>
        <pubDate>2020-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ALC Application Software series 4.x</category>
        <category domain="version">4.11.0</category>
          <category domain="product">ALC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.16.0<br />Includes version 1.15.0</p>
<h3>New features:</h3>
<ul>
<li>   Now possible to open and close LG's while position failure is present.</li>
<li>   Block LG fail classes added<br />      • Position failure alarms set default to LG Block fail class.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>   Corrected ALC Breaker Feedback Emulation.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ALC Application Software series 4.x &#x2013; v4.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-alc-4-&#x8F6F;&#x4EF6;/4-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dd193fdb-ca19-4efd-bf2c-caaeaeb26186</guid>
        <pubDate>2020-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ALC Application Software series 4.x</category>
        <category domain="version">4.10.1</category>
          <category domain="product">ALC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.16.0</p>
<h3>Corrections:</h3>
<ul>
<li>   Horn relay now working</li>
<li>   M-Logic PMS flags for GB/MB closed now working </li>
<li>   LG(load group) pos. fail alarm now possible when LG is disabled</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ALC Application Software series 4.x &#x2013; v4.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-alc-4-&#x8F6F;&#x4EF6;/4-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">67c5738e-c330-4cbb-b40b-5113d9073558</guid>
        <pubDate>2024-06-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ALC Application Software series 4.x</category>
        <category domain="version">4.14.0</category>
          <category domain="release-status">current</category>
          <category domain="product">ALC-4</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.34.0</p>
<h3>New features:</h3>
<ol>
<li>Five new M-Logic alarms 10-14 added in menu 3660-3700.</li>
</ol>
<p>&nbsp;</p>
<h3>Changes:</h3>
<ol>
<li>Nominal power for each load group increased from 10 MW to 32 MW.</li>
</ol>
<p>&nbsp;</p>
<h3>Corrections:</h3>
<ol>
<li>Translation now works even though no DU-2 is mounted and only new language is written.</li>
</ol>
<p>&nbsp;</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0763d0b2-a244-4cfe-920e-9bc8f95a85a1</guid>
        <pubDate>2021-04-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.16.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.23.0.</p>
<h3>New features: </h3>
<ul>
<li>Sungrow Logger 1000 protocol is added.</li>
<li>GroWatt PV inverter protocol is added.</li>
<li>ATESS Growatt BCU protocol is added.</li>
<li>Modbus master communication monitoring tool is added in menu 9080 and to the Input registers at address 53000.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Improved Q-share and de-load of last online DG.</li>
<li>Improved the SunSpec identifying information shown in the display.</li>
<li>Listed PV/BESS/PCS/BMS in alphabetic order in the display and in the USW.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected: Hybrid controller gets stuck on Sunspec initialization.</li>
<li>MB EXTERN TRIPPED warning text removed as the MB is not controlled by the ASC-4.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.19.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-19-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10387fcf-6a87-4669-8bf4-bfbc707aa343</guid>
        <pubDate>2021-11-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.19.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.24.2</p>
<h3>New features:</h3>
<ul>
<li>ABB A43/A44 power meter protocol added.</li>
<li>FIMER PVS980 PV protocol added.</li>
<li>Allsparkpower BMS protocol added.</li>
<li>TRUMPF TruConvert ACDC and DCDC ESS protocol added.</li>
<li>Vertiv Custom ESS protocol added.</li>
<li>M-Logic commands for setting mode to Droop, P/Q or V/f added. (Currently supported on Vertiv Custom and DEIF Generic)</li>
<li>Battery SOC added as input for delta alarms.</li>
<li>M-Logic flip-flops added.</li>
<li>GoodWe HT series PV protocol added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Y-cube: Power set point bit now also activated by Q reference.</li>
<li>Added Spinning reserve alarm 1 and 2 (7090 and 7100) to M-Logic alarms and limits.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Translation now works even though no DU-2 is mounted AND only new language is written.</li>
<li>Corrected: No ASC-4 PV irradiance sensor can make ASC-4 battery charge too much from DG. (Note: New selection 'No sensors' added to PV parameter 6301)</li>
<li>EVVO PV protocol can control multiple inverters while using unicast Modbus telegrams.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">15315e33-c2de-4277-8a3b-8b59f388afa4</guid>
        <pubDate>2021-09-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.18.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.24.1</p>
<h3>New features:</h3>
<ul>
<li>SinExcel PCS VSG (Droop) support.</li>
<li>Breaker feedbacks from Power meter using DEIF control available as M-Logic inputs.</li>
<li>New weather protocol for POA and BOM reading: Kipp &amp; Zonen - RT1 Smart Rooftop Monitoring System.</li>
<li>Havells 80-136kW PV protocol added.</li>
<li>Battery only: ESB on sequence configuration menu 2350. Can be used for delaying breaker close based on timer and running status.</li>
<li>Solar only: Choice of POA+BOM or GHI+BOM added to Instant Pmax parameter.</li>
<li>Solar only: Multiplier for POA/GHI irradiance sensor input now possible using parameter 6305.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Added inhibits for Ext comm 1 err (Parameter 7520).</li>
<li>Added delay timer for BMS comm err (Parameter 7690).</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Generating and charging capacities on Narada BMS now scaled correctly.</li>
<li>The monitoring telegram for SMA Cluster Controller wasn't cycling through the Modbus addresses.</li>
<li>Alarm inhibits were not working on some alarms</li>
<li>ASC-4 battery now only initiates charging after unit is powered up if SOC is below configured limit.</li>
<li>Minor corrections to Ausar MAE and PowerCube BMS protocols.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4-14-2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-14-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5440d797-444b-444d-9a57-3f2d03c0ec2a</guid>
        <pubDate>2020-10-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4-14-2</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.20.0</p>
<h3>Corrections:</h3>
<ul>
<li>OEM-specific correction updated.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9abcab58-30a0-4667-90c1-f14b1814bd9e</guid>
        <pubDate>2020-11-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.15.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.22.0.</p>
<h3>New features:</h3>
<ul>
<li>Support of the shared parameter for configurable amount of Fatal CAN error alarm.</li>
<li>Sinexcel PCS inverter is added.</li>
<li>Narada BMS is added.</li>
<li>Spinning reserve feature is added. </li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.17.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-17-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e5b5976d-a7c0-4c42-bd16-86bb66a4b359</guid>
        <pubDate>2021-07-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.17.1</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.24.1.</p>
<h3>Corrections:</h3>
<p>1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e9fa6bbc-c64d-494a-b7cd-5ed134f0d1c7</guid>
        <pubDate>2021-12-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.20.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.24.2</p>
<h3>New features:</h3>
<p>1- Sungrow LC100 BCU protocol added.<br />2- Huawei V.3 PV protocol added. This protocol replaces all older Huawei protocols for newer inverter firmware versions.<br />3- Sofar solar 1-40kW PV protocol added.<br />4- Sofar solar 50-70kW PV protocol added.<br />5- Havells 1-40kW PV protocol added.<br />6- Havells 50-70kW PV protocol added.<br />7- Chint (CPS) boost 100-250kW PV protocol added.<br />8- Accuvim-L power meter protocol added.</p>
<h3>Changes:</h3>
<p>1- Renamed "Ginlong Solis" PV protocol to "Solis (Ginlong)".</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.15.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-15-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fcf2360a-a69b-4101-bd03-d59076e1df1f</guid>
        <pubDate>2021-02-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.15.1</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.22.0.</p>
<h3>Corrections:</h3>
<ul>
<li>Derated nominal battery power was not taken into account when calculating charging references.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0e0d17cb-a1c8-4f5a-937d-0ba445282348</guid>
        <pubDate>2021-06-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.17.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.24.1.</p>
<h3>New features:</h3>
<ul>
<li>ABB SACE Emax 2 protocol (Power meter) is added.</li>
<li>Fallback timer for power limit on SunSpec (parameter 2810) is added.</li>
<li>DEIF Generic BESS protocol is added.</li>
<li>DEIF Generic can now be choosen as a stand-alone BMS protocol.</li>
<li>Pylontech PowerCube H1/H2 BMS protocol is added.</li>
<li>Phase direction can now be controlled from M-Logic.</li>
<li>BMS warning and shutdown alarm (parameters 7610 and 7620) are added.</li>
<li>Battery droop logic is added in parameter 2800. (Currently supported by DEIF generic only).</li>
<li>Ausar MAE v2 battery protocol is added.</li>
<li>Option T1 shortcircuit protection (parameters 2301, 2302, 2303 and 2311) is added. </li>
<li>Option T1 redundancy on ASC Battery is added, along with improvements for ASC PV redundancy.</li>
<li>CATL BMS protocol is added.</li>
<li>FIMER PVS980-58BC battery protocol is added.</li>
<li>Support for BMS write telegrams over Modbus is added.<br /><br /></li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Added BB volt/freq OK, BB voltage OK, BB frequency OK, PV volt/freq OK, PV voltage OK and PV frequency to M-Logic events.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected that Sunspec initialization sometimes fails if the inverter takes too long to set up.</li>
<li>When the ASC is a solar unit, it can no longer send negative P-ref set points to the inverter.</li>
<li>Corrected that emulation units were not able to start with PV/BESS protocol set to OFF.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">07a2819d-1278-415b-bece-fa34b50b6a2a</guid>
        <pubDate>2022-02-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.21.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.25.0</p>
<p><strong>New features</strong>: <br />1- CellCheck CM BMS protocol added.<br />2- Battery auto breaker close condition parameter 2360 added.<br />3- Growatt CP100-CP250 &amp; Growatt CP500-CP2250 PV protocols added.<br />4- Growatt Mac, Max &amp; Mid series PV protocol added.<br />5- The scale used for external P and Q setpoints given to the ASC, can now be changed between 1%, 0.1% and 0.01% using parameter 7504.<br />6- Freeze discharge, freeze charge, force discharge, and force discharging has been added to the ASC-battery M-Logic Outputs.<br />7- Support for using ASC4 battery in fixed power operation in a battery standalone application has been added.<br />8- Support for using ASC4 battery in island operation in a battery standalone application has been added.<br />9- Support for using ASC4 battery in mains power export operation in a battery standalone application has been added.<br />10- Support for using ASC4 battery in peak shaving operation in a battery standalone application has been added.<br />11- Sungrow LC100 Utlity LFP BCU protocol added.<br />12- Support of SinExcel DC/DC PDS added.<br />13- Support for SMA Data Manager PV protocol added. <br />14- DEIF generic ESS protocol can now switch P ref to be in % or kw/kvar and the number of decimals depending on the ESS config.<br />15- Custom M-Logic handles to and from ESS/BMS protocols added. (Currently only used for DEIF Generic)</p>
<p><strong>Changes</strong>:<br />1- Renamed "Sungrow LC100" BCU protocol to "Sungrow STXXXCP50-HV".<br />2- Renamed "Growatt" PV protocol to "Growatt UE-series".<br />3- PQ Island mode can now be used instead Auto Active mode in the Tesla BCU if "Set mode to P/Q" is activated from M-Logic.<br />4- The ASC Battery now accepts negative fixed power and external power setpoints.<br />5- M-logic control and feedback of power modes added to SinExcel PCS protocol.<br />6- Modbus telegram transmission conditions improved on SinExcel PCS protocol.<br /><br /><strong>Corrections</strong>:<br />1- Setpoints for P and Q references now works correct for 10V-2500V scaling.<br />2- The LFP BMS now uses the nominal power as the default value for charging/discharging capacity.<br />3- The Sungrow STXXXCP50-HV BCU register addresses is now offset with -1.<br />4- Q share and DG cosphi limits now works correctly for PV or Battery standalone applications.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.22.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-22-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">55503aef-c0e9-47d7-babc-5b95c608fc8c</guid>
        <pubDate>2022-05-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.22.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.25.0</p>
<h3>New features:</h3>
<ul>
<li>The ASC4-Battery can now control if ext. DGs should be started or stopped based on system load or SOC through a dry contactor output.</li>
<li>When the battery acts as a power source an optimal DG load can now be set through parameter 8014-8016, which the ASC will try to keep the DGs at.</li>
<li>M-Logic commands for enabling and disabling the charge parameters added along with M-Logic feedbacks.</li>
<li>Support for LS PowerBRiC ESS protocol added.</li>
<li>Support for EOS Energy Block BMS protocol added.</li>
<li>The ASC4-Battery can now limit the mains charging setpoint, so the peak shaving setpoint is not exceeded by enabling parameter 8024.</li>
<li>The ASC4-Battery can now change the voltage reference to be based on the busbar measurement instead of the nominal voltage, when a mains is connected to the busbar using parameter 2661.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Sungrow LC100 Utility LFP BCU protocol now supports running in VSG-mode, when droop is enabled within the ASC.</li>
<li>Sungrow STxxxCP50-HV BCU protocol updated for the latest VSG control scheme from Sungrow.</li>
<li>TRUMPF TruConvert AC/DC ESS protocol updated to always acknowledge alarms and set the communication timeout to be 60s.</li>
<li>Register address for SOC value from CellCheck CM BMS protocol updated.</li>
<li>The voltage and frequency reference sent during synchronization of ESB will now always be based on the average busbar measurement of all three phases. As long they are within the set acceptable limit.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>New autostart conditions have been added for the ASC4 battery, so the ESS will have an autostart-signal when running in off-grid scenarios and is gridforming.</li>
<li>When the ASC4 is in auto mode and an ESB close failure occurs, the inverter will only be stopped if the fail class of 2170 is set to be shutdown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.23.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-23-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">26a85aa5-5d76-41d8-a5da-515380c346f4</guid>
        <pubDate>2022-08-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.23.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.25.0</p>
<h3>New features:</h3>
<ul>
<li>The ASC-4 Battery can now change the frequency reference to be based on the busbar measurement instead of the nominal frequency, when a mains is connected to the busbar using parameter 2662.</li>
<li>Added Secure Elite 100/300/440 power meter protocol.</li>
<li>Added power meter protocol to read active/reactive power and breaker feedback from Cummins PC 3.x and PCC 3300 controllers.</li>
<li>Added power meter protocol to read active/reactive power and breaker feedback from Deep Sea 8xxx, 7xxx, 6xxx and 4xxx controllers.</li>
<li>Support for GTZKNE WK-BMS-C BMS protocol added.</li>
<li>Support for Sofar Solar 80-136kW PV protocol added.</li>
<li>Support for Thea PV protocol added.</li>
<li>Support for Coslight ESMU BMS protocol added.</li>
<li>Support for Deye SUN 30-50K-G03 PV protocol added (Unicast only).</li>
<li>Support for Danfoss Vacon Nxp ESS protocol added.</li>
<li>EOS Energy block BMS protocol now supports the internal boost charge feature.</li>
<li>Parameter 7062 "Man disp. CMD" can now be controlled through M-Logic.</li>
<li>If Parameter 7153 "SOC DG stop limit" is set to be higher than SOC threshold 2 and SOC DG start/stop is enabled, a warning will be shown in the status text.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Sungrow LC100 Utility LFP BCU protocol will now only start in VSG-mode when voltage is present on the busbar. The Q setpoint has also been inverted to match expected value.</li>
<li>SinExcel ESS protocol now supports changing voltage and frequency setpoints from the nominal values during droop mode.</li>
<li>Updated blackstart logic of FIMER PVS980bc ESS protocol to support version 1.76 of their Modbus SCADA interface.</li>
<li>Renamed "Schneider Conext CL 60" PV protocol to "Schneider CL 30/33/50/60".</li>
<li>Renamed parameter 7061 and 7062 from "Dispatch" to "Man. disp. ref" and "Man disp. CMD".</li>
<li>The minimum time for the "SOC DG stop limit" and "Sys P DG stop limit" to be activated has been changed to be 5s instead of 0s.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>The Q setpoint of Sungrow logger 1000 PV protocol is now inverted. P/Q Setpoints for Sungrow Logger 1000 is now given in percentage instead of kW/kVAR.</li>
<li>A Battery PCS will no longer try offload active power before stopping if it is the only grid forming device available on the busbar.</li>
<li>Negative fixed power set points is now working correctly in PMS applications.</li>
<li>The ASC-4 Battery will now remember its charge/discharge state after a complete controller shutdown, so it resumes the charge/discharge state after the controller powers up again.</li>
<li>Battery DG charging set points is now correct in battery stand-alone applications with mains connected to the busbar.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.23.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-23-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8fcaa83b-1860-465f-aca8-005e76b28e29</guid>
        <pubDate>2022-09-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.23.1</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.25.0</p>
<h3>Corrections:</h3>
<ul>
<li>The STxxxCP50-HV BCU protocol will now only send the start signal once.</li>
<li>Inverted the sign of Q reference and the measured reactive power from STxxxCP50-HV BCU protocol to match the DEIF controller's expectation of the sign of inductive and capacitive power.</li>
<li>Changed the default heatbeat timeout of STxxxCP50-HV BCU protocol to be 20s and added the option to disable heartbeat if "Custom input to ESS" is active within M-Logic.</li>
<li>Corrected the Modbus addresses used for P/Q ref. and ACP/ACQ reading for the SMA Data Manager PV protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.24.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-24-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2302890f-baa3-4c09-bc41-8e4d5b1c0fd9</guid>
        <pubDate>2022-11-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.24.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.28.0</p>
<h3>New features:</h3>
<ul>
<li>Support for Matter Energy PV protocol added.</li>
<li>PMS Mode update feature added to ASC-4 Solar and Battery.</li>
<li>A battery will now automatically charge to keep connected gensets at the min. DG load set point in island operation as long DG charging is enabled and SOC is below SOC maximum.</li>
<li>Batteries can now automatically charge to assist the plant in reaching required mains set points if enabled by parameter 8025 and mains charging is also enabled.</li>
<li>Support for Matter Energy PCS protocol added.</li>
<li>Support for INVT XG Series PV protocol added.</li>
<li>Inverter and busbar V/f measurements from inverter communication supported on all protocols on ASC-4 Solar and ASC-4 Battery.</li>
<li>Support for SolarEdge PPC PV protocol added.</li>
<li>New display view line for displaying ESS Power mode added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Updated Allspark BMS protocol to use the read DC output voltage for calculating maximum charge capacity.</li>
<li>Updated Schneider CL 30/33/50/60 PV protocol to only read 6 DC string current values to be compatible with the newest Schneider firmware.</li>
<li>Updated Huawei V.3 PV Protocol to send a start/stop command to the inverter based on the ASC status.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected issue where multiple batteries operating in island with PVs could cause the PVs to overproduce power compared to what the batteries was asked to charge.</li>
<li>Corrected issue where parameter 2741 for delaying regulation after start signal did not work for charging set points.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.25.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-25-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ee8578fe-3147-4736-b871-36d28d478fd4</guid>
        <pubDate>2023-02-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.25.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.29.0</p>
<h3>New features:</h3>
<ul>
<li>Added support for DEIF MIB 8000 power meter.</li>
<li>Added support for Eastron Smart X96 power meter.</li>
<li>Added support for EPC Power PCS protocol.</li>
<li>Added parameter 2810 to the ASC-4 Battery. It can be used to configure a timeout period after the last transmitted heartbeat signal before the PCS activates an error (only for supported ESS protocols).</li>
<li>Added parameters 2805 and 2806. The parameters support an adjustable offset to the droop curves used for the delta frequency and delta voltage calculations when a DG or a mains is connected.</li>
<li>Added Jinko PCS protocol.</li>
<li>Added BMSer Technology BMS protocol.</li>
<li>Added Narada w Ctrl BMS protocol.</li>
<li>Added support for Dynapower CPS-1500 PCS protocol.</li>
<li>Added a new M-Logic output and event. This is to give the user the option to manually activate boost charging in supported systems.</li>
<li>Added parameters 8201, 8202 and 8203 to set a PDS spinning reserve value. This sets the percentage of produced PDS power that should be reserved locally as extra available battery discharge capacity.</li>
<li>Added SICON PCS protocol.</li>
<li>Added support for Gold BMS protocol.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Sungrow LC100 Utility LFP and STxxxCP50-HV ESS protocols now use delta frequency and voltage regulation when operating in VSG on-grid mode.</li>
<li>Updated the Ausar MAE ESS protocol to support version A04.</li>
<li>Removed the pulse input counter configuration parameters from the display and USW.</li>
<li>Added +25 kV scaling on ASC-4. This includes adding 2 scaling levels 10 kV to 250 kV and 0.4 kV to 75 kV.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected missing three-phase power calculation in Danfoss Vacon ESS monitoring values.</li>
<li>Corrected an issue where a battery would still try to charge fully from a PV that was de-loading to stop.</li>
<li>Corrected calculation of frequency set point for ESB sync.</li>
<li>Corrected an issue where a battery would stop in a PMS auto application if the internal mode of the ASC was set to "No dispatch" instead only offloading when other voltage sources was connected to the busbar.</li>
<li>Corrected calculation of discharge capacity of the Powercube BMS protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.26.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-26-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c0cc361f-9347-475e-a20c-cbb8b9f03216</guid>
        <pubDate>2023-07-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.26.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.30.0</p>
<h3>New features</h3>
<ul>
<li>Added support for CATL liquid cooled BMS protocol.</li>
<li>Added support for Megarevo MPS protocol.</li>
<li>Added Ingeteam 3Play ABS PV protocol.</li>
<li>Added support for GTZKNE FX34 BMS protocol.</li>
<li>Added support for Polarium BMS protocol.</li>
<li>Added support for Sofar -G3 PV protocol.</li>
<li>Added support for Yingbo PCS protocol.</li>
<li>Added support for SinExcel PWS2 30K PCS protocol.</li>
<li>Added Battery SOC active threshold levels in M-Logic.</li>
<li>Added support for Oztek OZpcs-RS40 PCS protocol.</li>
<li>Added Power One PV protocol.</li>
<li>Added Eastron SDM630CMT power meter protocol.</li>
<li>Added parameters 7191 and 7193. If the parameters are enabled, they will overwrite the value of the maximum charge voltage and minimum discharge voltage read from the BMS.</li>
<li>Added Open PMS functionality.</li>
<li>Added Solis logger NISE PV protocol.</li>
<li>Added Kehua SPI PV protocol.</li>
<li>Added support for HoyCore HC01CUBE BMS protocol.</li>
<li>Added support for Ningbo Golden Shield BMS protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated Sinexcel PDS to read the power of up to 8 DC strings.</li>
<li>Changed the name of the existing CATL BMS protocol to "CATL air cooled BMS".</li>
<li>Changed the name of the existing Ingeteam 3Play PV protocol to "Ingeteam 3Play ABI".</li>
<li>Changed the Atess protocol to only send start/stop commands until the run state has changed.</li>
<li>Renamed existing SinExcel ESS protocol to "SinExcel PWS1".</li>
<li>Added support for Yingbo VSG mode.</li>
<li>Fixed Deye PV protocol issue.</li>
<li>Changed the status reading of the Ausar MAE v4 ESS protocol to only cause a shutdown at critical faults and no longer minor faults.</li>
<li>The Ausar MAE v4 ESS protocol now supports the charging mode for the low ripple current activated by the custom input to ESS in M-Logic.</li>
<li>Changed the name of the MTR protocol from MTR-3 to MTR-3/4.</li>
<li>RCCR inputs and outputs can now operate with negative P set points for ASC-4 Battery.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>A Sinexcel PCS without VSG would switch from V/f mode to P/Q mode during ESB synchronisation resulting in sync failure. This has been fixed.</li>
<li>Fixed Jinko protocol scaling of P/Q and current limits. Start/stop command issue has also been fixed.</li>
<li>In a PMS plant with PV charging enabled and the PV running with Instant P-Max enabled and set to no sensor, changing the SOC from a value below the SOC maximum value to a value above it would cause the battery to discharge. This has been fixed.</li>
<li>When an optimal DG load is enabled, the battery would not charge from the PV even though the PV was not fully loaded. This has been fixed.</li>
<li>Corrected issue with analogue output values for SOC, SOH, SOE, Generating Capacity and Charging Capacity not corresponding to the actual values.</li>
<li>Corrected scaling issue with read current values from the GOLD BMS protocol.</li>
<li>For the Matter PV protocol, fixed the issue with the broadcast write Modbus message for reactive power (Q).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.26.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-26-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">aa7917f0-b247-4eed-ab01-db73f332530a</guid>
        <pubDate>2023-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.26.1</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.30.0</p>
<p> </p>
<h3>Corrections</h3>
<ul>
<li>VSG mode changed for Sungrow LC100. Now always send e.g. F=50 and U=400, and only use P and Q set points whether the PCS is running alone or paralleling with another source.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.27.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-27-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c1278bd8-f41b-4fb1-a8d2-1ff506e79b91</guid>
        <pubDate>2023-12-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.27.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.33.0</p>
<h3>New features:</h3>
<p>• Added support for using CAT EMCP 4 controllers directly as power meter.<br />• Added support for Kehua BCS-B-HUD Series protocol.<br />• Added support for Sungrow Powerstack STxxxxkWh 250kW ESS protocol.<br />• Updated OpenPMS and Single Controller plants to support deloading of external gensets in island applications, when the start/stop digital output functionality is used.<br />• Added support for Delta EPCS 1200/1500/1725 ESS protocol.<br />• Added support for Sungrow LC200 ESS protocol.<br />• Added parameters 2671 and 2672 (P ref. const. gain and P ref. dyn. gain). These parameters allow the user to add a local constant or dynamic gain to the power reference sent to the inverter.<br />• Added support for Pixii PowerShaper ESS protocol.<br />• Added support for SinExcel 30P PCS protocol.<br />• Added new option in the drop-down menu for the Dynapower MPS-125. The functionality of the Dynapower CPS-1500 and the Dynapower MPS-125 is the same. <br />• Added support for Northvolt VMS ESS protocol.<br />• PV taking maximum load. Accept PV to increase the power and stop genset, even if the load is bigger than BESS nominal size.<br />• Added support for Canadian CSI 3PH protocol.<br />• Added support for Huasu BMS protocol. The TCPIP port number has been updated so it's possible to change the port number on a BMS, ESS and PDS. <br />• Added support for Seven Sensor 3S weather station protocol.<br />• Added support for Seven Sensor 3S-TP GHI-Thermopile Pyranometer weather station protocol.<br />• Added support for Sunwoda Main BCMU protocol.<br />• Added support for KGooer BMS protocol.<br />• Added support for Sunwoda BCMU protocol.<br />• Added support for HagelOcean PD-003V2 BMS protocol.</p>
<p> </p>
<h3>Changes:</h3>
<p>• Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.<br />• Changed control registers for the Power One PV protocol.<br />• Updated the Dynapower CPS/MPS ESS protocol to always be in off-grid mode when parameter 2801 is enabled. Also added droop curve adjustments to reach requested off-grid power set points.</p>
<p> </p>
<h3>Corrections.</h3>
<p>• Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue.<br />• Inverted the reactive power set point in the Sofar G3 PV protocol.<br />• Scaling of P/Q reference and charge/discharge capacity corrected in the Matter Energy PCS protocol.<br />• Corrected the Danfoss Vacon NXP ESS protocol, so that a sync of either ESB or MB is possible.<br />• Fixed scaling of the ESS AC measurements in emulation when AC scales other than 100-25000 V is used and with the ESB open.<br />• Corrected the start sequence of the Sicon PCS to only send a start command once.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.27.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-27-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f5a516b4-e1dd-4b7a-a1a8-34aff8b543e7</guid>
        <pubDate>2024-02-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.27.1</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p> </p>
<p> </p>
<p><strong>PM compatibility version 1.33.0</strong></p>
<h3>Corrections.</h3>
<p> • Sungrow LC200 Powerstack. PF is now calculated based on ESS P and Q instead of S measurement.<br />• For parameter DCdU (channel 7180), the actual value has been fixed when either BMS output voltage or PCS input voltage are not valid.<br />• Corrected SMA Datamanager protocol of how NaN values are handled for P and Q. It now shows 0 kW and 0 kvar.<br />• Corrected an issue where a failing write telegram could stop read telegrams from being sent out in the Sungrow Power stack ESS protocol.<br />• Corrected Sungrow Powerstack ESS protocol to not send P mode and only send grid mode when stopped. This is to prevent the BESS initializing status from always showing.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.27.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-27-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d4dd43d0-1c09-4a04-9d29-55130d481f4d</guid>
        <pubDate>2024-03-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.27.2</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p><strong>PM compatibility version 1.33.0</strong></p>
<h3>Corrections:</h3>
<p><br />• Corrected issue where multiple batteries would not share the allowed charging power when peak shaving charging limit is used.<br />• Switch from AUTO to SEMI on another device could cause a breaker to open and stop in rare cases.<br />• Fixed an issue where PV protocol for Canadian CSI 3PH did not start correctly.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.28.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-28-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d2ed4772-aaab-4db6-a148-2570d057c9d6</guid>
        <pubDate>2024-05-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.28.0</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p><strong>PM compatibility version 1.33.0</strong></p>
<h3>New features</h3>
<p>&nbsp; &nbsp;1- Added support for the Acrel ADL power meter protocol.<br>&nbsp; &nbsp;2- Added support for Alfen BCU.<br>&nbsp; &nbsp;3- Added new parameter 8084 "Inhibit MB/TB open". This allows a PCS (if supported) to delay an opening of an MB, TB or ESB if the grid mode of the PCS is not ready for the switch. This is only for semi and LTO openings. Mains failures will ignore this setting.<br>&nbsp; &nbsp;4- Added support for hotel load; another source drawing power from the system that is not the customer. This is subtracted from nominal power and added to the power reference.<br>&nbsp; &nbsp;5- Added support for Lithium Valley BMS protocol.<br>&nbsp; &nbsp;6- Created parameter 7200 "Ext. DG. break. open" to set the breaker open point for ext. DGs. If the last ext. DG is required to stop in an off-grid application, the start/stop digital output is kept high until the battery has deloaded the ext. DG below the breaker open point.<br>&nbsp; &nbsp;7- Added support for Enervenue BMS protocol.<br>&nbsp; &nbsp;8- Added new power meter protocol for Eastron Smart X96 with digital input support.<br>&nbsp; &nbsp;9- Added new PV protocol for Meteocontrol Bluelog XC.<br>&nbsp; &nbsp;10- Added support for Huawei SACU Smartlogger.<br>&nbsp; &nbsp;11- Added new choice for delta alarm parameters to allow use with larger batteries.<br>&nbsp; &nbsp;12- Added support for Alfen BCU.<br>&nbsp; &nbsp;13- Added new M-Logic output "External ESS on PV busbar". This allows an ASC Solar to operate in Fixed Power mode with an external battery if no other voltage sources are connected to the busbar.<br>&nbsp; &nbsp;14- SOLAR: Added new PV protocol for Solax X3-FORTH/X3-MEGA G2.<br>&nbsp; &nbsp;15- SOLAR: Added new PV protocol for Solax MIC-G2/Pro-G2.<br>&nbsp; &nbsp;16- STORAGE: Added new ESS protocol for KStar GSE 50-630 PCS.<br>&nbsp; &nbsp;17- STORAGE: Added new BMS protocol for Gotion BMS.<br>&nbsp; &nbsp;18- Added support for BYD Cube Pro BMS.<br>&nbsp; &nbsp;19- Added new ESS protocol for Delta PCS 100HV.<br>&nbsp; &nbsp;20- Added support for Huasu S02/03 BMS.<br>&nbsp; &nbsp;21- Added parameter 8083. This allows the user to select if the PMS isochronous master functionality should only be supported in V/f mode or if it should also be supported in droop operation.<br>&nbsp; &nbsp;22- &nbsp;Added new power meter protocol for Kohler APM403 genset meter.<br>&nbsp; &nbsp;23- Added parameter 2664. This allows the user to set a custom voltage reference gain compared to the nominal parameter. This is useful for adjusting for internal transformers of the PCS.<br>&nbsp; &nbsp;24- Added new BMS protocol for BMSer Single Cluster.<br>&nbsp; &nbsp;25- Added new M-Logic line for lowest running ESS ID.<br>&nbsp; &nbsp;26- Added support for breaker feedback for DEIF MIC-2 power meter protocol.<br>&nbsp; &nbsp;27- Added support for SinExcel 30P PCS/PDS protocol.<br>&nbsp; &nbsp;28- Added support for Sinosoar SP100H BCU protocol.<br>&nbsp; &nbsp;29- Added new PV protocol for Sineng SP320K Series.<br>&nbsp; &nbsp;30- Add new M-Logic flags for any DG/Mains/other battery on busbar.</p>
<h3>Changes</h3>
<p>&nbsp; &nbsp;1- Updated the sequence of grid mode switching in the Sinexcel PWS1 ESS protocol. It will now always use the VSG modes as intermediate modes, in between the required grid modes, to prevent the PCS from stopping.<br>&nbsp; &nbsp;2- Huasu BMS update: New offset for battery current, max charge current and max discharge current. The old offset is 1600 A. The new offset is 3000 A.<br>&nbsp; &nbsp;3- Updated Dynapower CPS and MPS ESS protocols to also enable the anti-islanding register if P/Q mode is forced from M-Logic.<br>&nbsp; &nbsp;4- Changed the name of the existing Huasu BMS to Huasu S04 BMS.<br>&nbsp; &nbsp;5- Huasu S04 BMS will no longer open the DC breaker when the BMS state is fault.<br>&nbsp; &nbsp;6- Updated SinExcel PWS1 ESS protocol to use new voltage offset and rated voltage/frequency registers based on ESS software version 1517 and later.</p>
<h3>Corrections:</h3>
<p>&nbsp; &nbsp;1- Corrected issue where the Megarevo MPS ESS protocol would reinitialize the start sequence of the PCS in a loop.<br>&nbsp; &nbsp;2- Corrected issue where the phase sequence alarm would be activated if the voltage/frequency measurements where sourced from PV/ESS communication.<br>&nbsp; &nbsp;3- Corrected issue where ESS would auto start in OpenPMS when any external DG on BB and not when start signal had been given.<br>&nbsp; &nbsp;4- Fixed M-Logic line evaluation over ethernet connection to ASC4.<br>&nbsp; &nbsp;5- Fixed Modbus M-Logic status registers over ethernet connection to ASC-4.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ASC Application Software series 4.x &#x2013; v4.29.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-asc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-4x-&#x7CFB;&#x5217;/4-29-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1d4e2c6b-f509-43e8-b469-227c3b6a51ec</guid>
        <pubDate>2025-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ASC Application Software series 4.x</category>
        <category domain="version">4.29.0</category>
          <category domain="release-status">current</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
        <content:encoded><![CDATA[
<p>PM compatibility version 1.35.1</p>
<h3>New features</h3>
<ul>
<li>Added support for Sungrow LC200 Multi PCS BCU protocol.</li>
<li>Added new PV protocol for LIVOLTEK SunSpec.</li>
<li>Added new BMS protocol for HuaSu S06.</li>
<li>Added new parameter 7960 "DEIF Generic Offset", which allows you to select between higher and lower Modbus address spaces for the ESS protocol "DEIF Generic".</li>
<li>Added new "Wait" status for the ESS protocol DEIF Generic. This status guarantees that the ASC does not send any start or stop signal over Modbus and triggers the "ESS NOT READY" status text in the display.</li>
<li>Added new ESS protocol for Enjoy PCS.</li>
<li>Added new BMS protocol for EVE MBMU BMS.</li>
<li>Added new PV protocol Eachenergy PV. The protocol also supports some Chisage PV inverters.</li>
<li>Added new ESS protocol Sungrow LC100 Utility v1.12.</li>
<li>Added new BMS protocol for HuaSu Single Cluster.</li>
<li>Added new BCU protocol for BESS Nomad</li>
<li>Added new parameter 8400 "Maintenance Charge", which allows charging based solely on maximum charge capacity from BMS instead of SOC. This feature can be used to fully charge battery systems where the SOC is unreliable.</li>
<li>Added new parameter 8401 "Charge capacity threshold", which sets a threshold in kW of the maximum charge capacity from BMS where 8400 "Maintenance Charge" shall adhere to stop charging.</li>
<li>Added new M-Logic event set to true if genset load share in PMS is currently in reverse power.</li>
<li>Added parameter set minimum genset cosphi in inductive range.</li>
<li>Added M-Logic lines to skip Q-Ramping for batteries.</li>
<li>Added new PV protocol for Hypontech PV inverter.</li>
<li>Ningbo BMS will now read register 284 to check if communication between BMS and Golden Shield controller has been lost.</li>
<li>Added new PCS protocol for WEG BIW610 PCS.</li>
<li>Added new BMS protocol for WEG BMS.</li>
<li>Added new protocol for Sungrow LC200 Single PCS</li>
<li>Added new PV protocol Solis Logger.</li>
<li>Added new BCU protocol for Kubank LEMS BCU.</li>
<li>Added new protocol for Sungrow LC200 DPS</li>
<li>Added new PV protocol for SAJ C6.</li>
<li>Added new protocol for Moura BESS BCU.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Parameter 6301 "Instant P max." is now enabled by default to allow derating the nominal power for battery by maximum dispatch or maximum charge power from BMS communication.</li>
<li>ESS protocol Sinosoar SP100H now stops sending internal BMS telegrams when the BMS protocol is configured.</li>
<li>Improved latency on reception of PMS telegrams.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>KStar GSE 50-630 PCS protocol can now handle the transition from V/f to P/Q mode.</li>
<li>Corrected issue where an Open PMS plant would not automatically give an auto start signal when the operation mode was peak shaving mode and the load was above the peak shaving set point.</li>
<li>Corrected issue where BMS protocol Ningbo BMS would not connect/disconnect BMS racks.</li>
<li>Fixed issue where Sinosoar SP100H was not able to read 112 registers in 1 telegram. The reactive power feedback and set point direction have also been corrected.</li>
<li>Fixed an issue where ESB/PVB close fail alarm did not reset even when closing ES/PV breaker was not needed.</li>
<li>Fixed incorrect scaling of active and reactive power set points when writing to LIVOLTEK SunSpec PV.</li>
<li>Fixed an issue where Open PMS Solar controllers did not share auto start signals and did not start when an external mains was available.</li>
<li>Solax MIC-G2/Pro-G2 PV protocol will be ready for operation when all PV inverters have been unlocked with password.</li>
<li>Seven sensor 3S-TP and Seven sensor 3S-SI: Some addresses and data were missing and changed from the two weather stations.</li>
<li>SinExcel PWS2 30K ESS protocol now supports Droop mode but only if Droop mode is set through M-Logic.</li>
<li>M-Logic command 'Inh. PVB/ESB button' can now be read by the TDU. This requires TDU version 1.4.3.0 or later.</li>
<li>Corrected an issue where parameter 2664 "U ref. gain" had no effect on voltage offsets for ESS protocols SinExcel PWS1, SinExcel PWS2 30K and SinExcel 30P.</li>
<li>Corrected an issue where Huawei Smartlogger PV protocol did not support monitoring of multiple Huawei Smartlogger inverters.</li>
<li>Fixed issue for the Sinexcel 30p protocol where the start and stop commands were not sent correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Backup Tool Software &#x2013; v1.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5907;&#x4EFD;&#x5DE5;&#x5177;&#x8F6F;&#x4EF6;&#x5305;/1-0-0-0-r884/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3e3a55fb-515f-4b7f-b3a6-8fbbb613dc6f</guid>
        <pubDate>2018-12-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Backup Tool Software</category>
        <category domain="version">1.0.0.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPU-3</category>
          <category domain="product">MDR-2</category>
          <category domain="product">PPU-3</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">MDR-1</category>
          <category domain="product">PPM-2</category>
          <category domain="product">PPU-2</category>
          <category domain="product">PPM-3</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<p>Multi-line 2 - AGC v.2.xx <br />Multi-line 2 - GPC v.2.xx <br />Multi-line 2 - GPU v.2.xx <br />Multi-line 2 - PPU v.2.xx <br />Multi-line 2 - BGC <br />Multi-line 2 - MDR <br />Multi-line 2 - PPM v.2.xx <br />Multi-line 2 - BGC-L <br />Multi-line 2 - AGC v.3.xx <br />Multi-line 2 - AGC v.1.xx <br />Multi-line 2 - PPM v.3.xx <br />Multi-line 2 - PPU v.3.xx <br />Multi-line 2 - GPU v.3.xx <br />Multi-line 2 - GPC v.3.xx <br />Multi-line 2 - AGC v.4.xx <br />Multi-line 2 - GPU-3 REC ver. 3.xx <br />Multi-line 2 - PPU v.3.xx Marine <br />Multi-line 2 - GPU v.3.xx Marine <br /> </p>
<p>There are no changes in the software.</p>
<h3>The following application software (ASW) files have been corrected or added to the product database:</h3>
<ul>
<li>PPM-2 version 9.00.7</li>
<li>PPM-2 version 2.50.5</li>
<li>PPM-2 version 2.50.6</li>
<li>PPM-2 version 2.50.5</li>
<li>PPM-2 version 2.50.8</li>
<li>PPM-2 version 2.51.0</li>
<li>PPM-2 version 2.51.1</li>
<li>PPM-2 version 2.51.2</li>
<li>PPM-2 version 2.51.3</li>
<li>PPM-2 version 2.51.4</li>
<li>PPM-2 version 2.52.0</li>
<li>PPM-2 version 2.52.1</li>
<li>PPM-2 version 2.52.2</li>
<li>PPM-2 version 2.52.3</li>
<li>PPM-2 version 2.52.3</li>
<li>STD-ML2 version 2.42.7</li>
<li>STD-ML2 version 2.42.8</li>
<li>MDR-2 version 2.05.2</li>
<li>AGC CMI version 4.10.6</li>
<li>AGC CMI version 4.10.7</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Backup Tool Software &#x2013; v1.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5907;&#x4EFD;&#x5DE5;&#x5177;&#x8F6F;&#x4EF6;&#x5305;/1-0-0-0-rc/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b8bd972e-e2c6-4452-aef2-975b131ff609</guid>
        <pubDate>2015-10-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Backup Tool Software</category>
        <category domain="version">1.0.0.0</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPU-3</category>
          <category domain="product">MDR-2</category>
          <category domain="product">PPU-3</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">MDR-1</category>
          <category domain="product">PPM-2</category>
          <category domain="product">PPU-2</category>
          <category domain="product">PPM-3</category>
        <content:encoded><![CDATA[
<h3>Version 1.0.0.0</h3>
<p>The ”ML2 Backup Tool” enables the user to upgrade the bootloader software, perform a backup of settings and restore settings in the ML2 device.</p>
<p>The tool is built as a software wizard which will guide the user safely through the desired processes step by step.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 BGC Application Software series 1.x. &#x2013; v1.10.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-bgc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-10-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c8f3d813-a5fd-46a9-a5f4-a49045a06cf6</guid>
        <pubDate>2015-05-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 BGC Application Software series 1.x.</category>
        <category domain="version">1.10.3</category>
          <category domain="release-status">current</category>
          <category domain="product">BGC-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Update of self-check functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 BGC Application Software series 1.x. &#x2013; v1.10.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-bgc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-10-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">56469bff-55a9-4949-b94e-d469095515f8</guid>
        <pubDate>2007-02-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 BGC Application Software series 1.x.</category>
        <category domain="version">1.10.2</category>
          <category domain="product">BGC-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Menu for Voltage Trip (Phase-Phase or Phase-Neutral) removed.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 BGC Application Software series 2.x. &#x2013; v2.50.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-bgc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-50-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">658207ad-96ef-49f8-bdcd-71cba8a42bec</guid>
        <pubDate>2013-03-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 BGC Application Software series 2.x.</category>
        <category domain="version">2.50.2</category>
          <category domain="product">BGC-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Start attempt settings was ignored.Corrected.</li>
<li>Minimum load in AMF was ignored.Corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 BGC Application Software series 2.x. &#x2013; v2.50.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-bgc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-50-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d74dd2b7-6bfb-4f54-afb8-f363812575e7</guid>
        <pubDate>2015-04-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 BGC Application Software series 2.x.</category>
        <category domain="version">2.50.3</category>
          <category domain="release-status">current</category>
          <category domain="product">BGC-2</category>
        <content:encoded><![CDATA[
<p>This software applies to the following DEIF products:</p>
<p>Multi-line 2 - BGC</p>
<p>Multi-line 2 - BGC-L</p>
<h3>Changes:</h3>
<ul>
<li>1- Update of self-check functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CANOpen EDS-file for Application BGC &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-canopen-eds-&#x6587;&#x4EF6;-bgc-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">daa74220-3698-476a-b8ef-cba7e45beff2</guid>
        <pubDate>2004-02-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CANOpen EDS-file for Application BGC</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">BGC-2</category>
        <content:encoded><![CDATA[
<p>This software applies to the following DEIF products:</p>
<p>Multi-line 2 - BGC</p>
<p>Initial version suitable for BGC applications</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CANOpen EDS-file for Application EC-1 ver. 1.xx. &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-canopen-eds-&#x5E94;&#x7528;ec-1&#x8F6F;&#x4EF6;-1xx&#x7248;&#x672C;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ee4f5521-8e81-4b07-b0ee-cf78c0260365</guid>
        <pubDate>2006-01-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CANOpen EDS-file for Application EC-1 ver. 1.xx.</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">EC-1</category>
          <category domain="product">EC-1M</category>
          <category domain="product">GC-1</category>
        <content:encoded><![CDATA[
<p>This software applies to the following DEIF products:</p>
<p>Multi-line 2 - EC-1/GC-1</p>
<p>1.00.0 23-08-2006 Download format changed to zip</p>
<p>1.00.0 26-01-2006 Initial version suitable for EC-1 sw ver. 1.30 applications</p>
<p>1.00.0 26-01-2006 Initial version suitable for EC-1 sw ver. 1.30 applications</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CANOpen EDS-file for Application series 1.7x.x. &#x2013; v1.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-canopen-eds-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1-7xx-&#x7CFB;&#x5217;/1-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d1abf546-699a-4fc7-92d3-a95bd2c5a341</guid>
        <pubDate>2020-06-18T13:37:44&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CANOpen EDS-file for Application series 1.7x.x.</category>
        <category domain="version">1.00</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<p>This GSD-file is used in connection with the option H1 for a multi-line 2 unit - CANOpen communication - and is the initial version. The name of the file is Deif100.zip. The file apply to the standard multi-line 2 application from version 1.50.1 and forward</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CANOpen EDS-file for Application series 1.7x.x. &#x2013; v2.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-canopen-eds-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1-7xx-&#x7CFB;&#x5217;/2-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dc57c878-f5cb-4773-a466-ef629530d458</guid>
        <pubDate>2003-04-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CANOpen EDS-file for Application series 1.7x.x.</category>
        <category domain="version">2.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - GPC v.2.xx </li>
<li>Multi-line 2 - GPU v.2.xx</li>
<li>Multi-line 2 - PPU v.2.xx</li>
</ul>
<h3>Changes</h3>
<ul>
<li>a- Protocol for CANOpen updated. EDS-file suites std. application version 1.60.0 and up to version 1.70.x</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CANOpen EDS-file for Application version 2.xx.x. &#x2013; v3.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-canopen-eds-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2xxx-&#x7248;&#x672C;/3-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0868af01-d9ce-428e-9846-0e8feab38e75</guid>
        <pubDate>2003-04-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CANOpen EDS-file for Application version 2.xx.x.</category>
        <category domain="version">3.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - GPC v.2.xx&nbsp;</li>
<li>Multi-line 2 - GPU v.2.xx</li>
<li>Multi-line 2 - PPU v.2.xx</li>
<li>Initial versions suitable for application version 2.00.0 for PPU, GPU and GPC</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CANOpen EDS-file for GPU REC version 3.xx. &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-canopen-eds-&#x8F6F;&#x4EF6;-gpu-rec-3xx-&#x7248;&#x672C;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">968974fc-71a7-4bbe-a096-729a046bb148</guid>
        <pubDate>2012-01-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CANOpen EDS-file for GPU REC version 3.xx.</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - GPU-3 REC ver. 3.xx</li>
<li>Initial release</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CGC 200 Application Software series 2.x &#x2013; v2.24.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-cgc-200-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-24-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">52c086ca-c144-49ea-8e1c-8749a0128d94</guid>
        <pubDate>2014-12-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CGC 200 Application Software series 2.x</category>
        <category domain="version">2.24.0</category>
          <category domain="release-status">current</category>
          <category domain="product">CGC 200</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>High temperature shutdown problem fixed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CGC 400 Application Software series 1.x. &#x2013; v1.15.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-cgc-400-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-15-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">679c53c3-9e3e-4aaf-a0ce-3ae3bdfc0ba6</guid>
        <pubDate>2020-02-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CGC 400 Application Software series 1.x.</category>
        <category domain="version">1.15.1</category>
          <category domain="product">CGC 400</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>   Invalid SPN messages are no longer shown in the DM1 log. TSC1 SA is now configurable for the Perkins protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CGC 400 Application Software series 1.x. &#x2013; v1.15.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-cgc-400-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-15-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">af945cb3-4ab1-430d-b1d1-75f0a9040279</guid>
        <pubDate>2020-06-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CGC 400 Application Software series 1.x.</category>
        <category domain="version">1.15.2</category>
          <category domain="product">CGC 400</category>
        <content:encoded><![CDATA[
<p>Version 1.15.2 based on version 1.15.1</p>
<h3>Corrections:</h3>
<ul>
<li>&nbsp; &nbsp;The MB will no longer trip on startup if the breaker is configured as a normally closed relay and the mains is okay.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 CGC 400 Application Software series 1.x. &#x2013; v1.15.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-cgc-400-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-15-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ed5bd910-78bd-4e94-a7d5-d130e0766891</guid>
        <pubDate>2025-03-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 CGC 400 Application Software series 1.x.</category>
        <category domain="version">1.15.3</category>
          <category domain="release-status">current</category>
          <category domain="product">CGC 400</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>It is now possible to disable charge 61 alarm in M-Logic.</li>
<li>Scania EMS2 low oil pressure alarm will be ignored when the engine is stopped.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 EC-1/GC-1 Application Software Rus. Lang. Package series 1.x. &#x2013; v1.43.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ec-1-gc-1-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;&#x5305;-1x-&#x7CFB;&#x5217;/1-43-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">30f781cd-06bf-4c2c-aed2-9056bc0708d8</guid>
        <pubDate>2008-06-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 EC-1/GC-1 Application Software Rus. Lang. Package series 1.x.</category>
        <category domain="version">1.43.2</category>
          <category domain="product">EC-1</category>
          <category domain="product">EC-1M</category>
          <category domain="product">GC-1</category>
        <content:encoded><![CDATA[
<ul>
<li>Binary inputs with cable supervision updated</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 EC-1/GC-1 Application Software Rus. Lang. Package series 1.x. &#x2013; v1.43.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ec-1-gc-1-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;&#x5305;-1x-&#x7CFB;&#x5217;/1-43-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a7238956-5629-4644-8bce-3167030a1f67</guid>
        <pubDate>2010-10-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 EC-1/GC-1 Application Software Rus. Lang. Package series 1.x.</category>
        <category domain="version">1.43.4</category>
          <category domain="release-status">current</category>
          <category domain="product">EC-1</category>
          <category domain="product">EC-1M</category>
          <category domain="product">GC-1</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - EC-1/GC-1  </li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Status of cable supervision in USW optimised</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 EC-1/GC-1 Application Software Std. Lang. Package series 1.x. &#x2013; v1.43.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ec-1-gc-1-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;&#x5305;-1x-&#x7CFB;&#x5217;/1-43-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">feb82d69-ae24-40c9-82d8-9b44ee1c38b7</guid>
        <pubDate>2009-08-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 EC-1/GC-1 Application Software Std. Lang. Package series 1.x.</category>
        <category domain="version">1.43.3</category>
          <category domain="product">EC-1</category>
          <category domain="product">EC-1M</category>
          <category domain="product">GC-1</category>
        <content:encoded><![CDATA[
<ul>
<li>Wire break symbol in Chinese added.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ECU 100 Application Software series 1.xx &#x2013; v1.02.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ecu-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1xx-&#x7CFB;&#x5217;/1-02-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">021352d6-2582-4872-b169-e5c0af153eab</guid>
        <pubDate>2016-03-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ECU 100 Application Software series 1.xx</category>
        <category domain="version">1.02.1</category>
          <category domain="release-status">current</category>
          <category domain="product">ECU 100</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>When M-Logic cooldown threshold is selected, it will be used regardless if parameter 6214 is 0.</li>
<li>Improved RPM measurement.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>EIC alarms used as low alarms would appear when the CAN communication was lost.</li>
<li>Idle run could cause external start not to work.</li>
<li>Running hour counter offset could be adjusted to more than 99999 hrs.</li>
<li>Engine could end up in an infinite state between crank and running detection.</li>
<li>Alarms added to prevent this:<br />- Running detection reached timer (parameter 6351)<br />- External engine stop detection (parameter 6352)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 ECU 100 Application Software series 1.xx &#x2013; v1.02.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ecu-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1xx-&#x7CFB;&#x5217;/1-02-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5c7b1f61-aa51-4329-89cd-a55db9a20a96</guid>
        <pubDate>2016-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 ECU 100 Application Software series 1.xx</category>
        <category domain="version">1.02.0</category>
          <category domain="product">ECU 100</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Contrast offset added in parameter 9152.</li>
<li>PT 1000 sensors introduced in multi-input 6 and multi-input 7.</li>
<li>Several events and limits added to M-Logic.</li>
<li>Added one additional battery low alarm (parameter 4950).</li>
<li>Inhibits can be set in battery low/high menu (parameter 4950/4960/4970).</li>
<li>Oil renewal feature introduced.</li>
<li>Battery voltage column now available in every entry in the log information in the DEIF Utility Software.</li>
<li>Added three freely translatable texts in the view lines.</li>
<li>Added support of ADEC CAN open, shutdown override.</li>
<li>Added EIC manual speed regulation</li>
</ul>
<p> </p>
<h3>Changes:</h3>
<ul>
<li>Multi-inputs made linear in application emulation.</li>
<li>Extended maximum limit in start on time, parameter 6183.</li>
<li>Extended fuel fill check timer (parameter 6553).</li>
<li>Made it possible to enable/disable fuel fill check (parameter 6553).</li>
<li>Made it possible to use auto acknowledge on Ext. Comm. Error parameter.</li>
<li>Start attempt maximum limits changed. Extended stop timer minimum limit changed.</li>
<li>Language translation changed. From now on it is not possible to select a different font. The two fonts are now merged together, and containing all previously used characters. New characters are added. If any unsupported signs are written to the device, the signs will appear as ' ' (space).</li>
<li>Three RMI sensor curves added. One for each RMI type.  It will be possible to choose them in channel 10460, 10630 and 10800 by selecting "Sensor type 4" in the DEIF Multi-line 2 Utility Software v.3.</li>
</ul>
<h3>Corrections:</h3>
<p> </p>
<ul>
<li>Stop coil did not activate when start sequence was aborted.</li>
<li>Corrected missing digit to running hours.</li>
<li>Sign of display values between -1.0...0.0 with one or two decimals shown correct.</li>
<li>Missing EIC values in analogue delta alarms added.</li>
<li>Measurement through the MPU input caused periodical peaks in the RPM measurement,  which could cause an unwanted trip of the generator breaker.</li>
<li>M-Logic line combination misinterpretation corrected.</li>
<li>Application emulation couldn't start properly with breaker and engine commands selected as inactive.</li>
<li>PT sensor offset parameters now corrected to compensate for the cable resistance.</li>
<li>Unit and MTU ADEC(SAM) communication not started during certain power supply situations - corrected. (Updated correction to avoid start request after communication has been reestablished).</li>
<li>M-Logic command "Start and Close GB" was ignored during cool down.</li>
<li>SCANIA EMS2 correction of start/stop.</li>
<li>Clock synchronise over Modbus was causing the service timer to offset its current timer value - corrected.</li>
<li>Configuration of output relays corrected, so all functions can be connected to all available relays.</li>
<li>Selection of multi-inputs for fuel pump logic corrected.</li>
<li>Fuel pump relay could activate at power-up of the controller before fuel level measurement has settled.</li>
<li>Several Modbus (option H2) addresses were not working - corrected.</li>
<li>MTU MDEC 302/303 protocols battery voltage measurement corrected.</li>
<li>Idle run timer now resets at each start attempt.</li>
<li>Nominal RPM now available to configure.</li>
<li>Hz/V failure group 4560 is removed.</li>
<li>Unit could reboot if a Modbus command was sent while 'Inhibit modbus commands' was active</li>
<li>Running hour counter could reset unintendedly - corrected.</li>
<li>Running hour counter could reset unintendedly at power cycle - corrected.</li>
<li>Scania EMS2 KWP2000 log clear now possible.</li>
<li>Exhaust gas temperature - right/left was not shown correctly in display.</li>
<li>Storage of service timer values during reset corrected.</li>
<li>Relays could activate under boot sequence - corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GC-1F Application Software series 1.x. &#x2013; v1.24.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gc-1f-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-24-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">56b55f1f-32c0-4ced-a5a3-ad4cfd7a7e2b</guid>
        <pubDate>2012-02-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GC-1F Application Software series 1.x.</category>
        <category domain="version">1.24.5</category>
          <category domain="release-status">current</category>
          <category domain="product">GC-1F</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>GC-1F v.1.xx</li>
<li>EIC: Modbus readings and displaying of a few EIC data: Coolant temperature, Fuel temperature and Charge Air Temperature where presented with different number of decimals depending on the engine protocol selected. This has now been aligned so data is presented in the same manner independent of engine protocol selected.</li>
<li>IC: FMI texts updated to meet J1939 specification.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GC-1F Application Software series 1.x. &#x2013; v1.24.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gc-1f-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7CFB;&#x5217;/1-24-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cc6a640c-9d5f-4da0-8977-34b6d6e62b2c</guid>
        <pubDate>2011-12-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GC-1F Application Software series 1.x.</category>
        <category domain="version">1.24.4</category>
          <category domain="product">GC-1F</category>
        <content:encoded><![CDATA[
<ul>
<li>Solved problem: Breaker feedback alarm, without the specified delay</li>
<li>USW MB Close Alarm text changed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GC-1F Application Software series 2.x. &#x2013; v2.33.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gc-1f-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-33-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f4f79073-ac1e-4516-a0e0-bb3d114abe59</guid>
        <pubDate>2017-03-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GC-1F Application Software series 2.x.</category>
        <category domain="version">2.33.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GC-1F</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Five M-Logic alarms have been added.</li>
<li>In the AMF variant the inhibits "Genset Hz/V NOT OK" and "Mains Hz/V NOT OK" have been introduced. In the ATS variant the inhibits "Source 1 Hz/V NOT OK" and "Source 2 Hz/V NOT OK" have been introduced.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Timers have been removed from #2240 and #2250. The alarms are now instant.</li>
<li>Sleep mode can no longer be disabled.</li>
<li>The sleep mode timer will now start running even though an unacknowledged alarm is present. Furthermore the alarm LED is no longer turned off when sleep mode is active.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>While an ATS was powered down and a source went bad, the ATS would not go to a healthy source when it powered back up in auto. This correction only affects ATS controllers with pulse breakers.</li>
<li>The controller no longer tries to reclose the breaker when an active alarm is configured with Trip MB or Trip GB fail classes.</li>
<li>The ATS now considers a breaker, tripped by a fail class, the same as a mains failure, and will change source if healthy.</li>
<li>Extended stop timer is now activated if running feedback disappears abruptly.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GCU 100 Application Software series 1.xx. &#x2013; v1.02.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gcu-100-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1xx-&#x7CFB;&#x5217;/1-02-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">25a46f3d-d925-419d-9693-17630dc91458</guid>
        <pubDate>2016-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GCU 100 Application Software series 1.xx.</category>
        <category domain="version">1.02.0</category>
          <category domain="product">GCU 100</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Contrast offset added in parameter 9152.</li>
<li>PT 1000 sensors introduced in multi-input 6 and multi-input 7.</li>
<li>Several events and limits added to M-Logic.</li>
<li>Added one additional battery low alarm (parameter 4950).</li>
<li>Inhibits can be set in battery low/high menu (parameter 4950/4960/4970).</li>
<li>Oil renewal feature introduced.</li>
<li>Battery voltage column now available in every entry in the log information in the DEIF Utility Software.</li>
<li>Added three freely translatable texts in the view lines.</li>
<li>Added support of ADEC CAN open, shutdown override.</li>
<li>Added EIC manual speed regulation</li>
</ul>
<p> </p>
<h3>Changes:</h3>
<ul>
<li>Multi-inputs made linear in application emulation.</li>
<li>Parameter ranges in parameters 1150 and 1160 extended.</li>
<li>Increased parameter 2112 maximum value.</li>
<li>Extended maximum limit in start on time, parameter 6183.</li>
<li>Hz/V Ok parameter 6821 minimum value now extended to zero.</li>
<li>Extended fuel fill check timer (parameter 6553).</li>
<li>Made it possible to enable/disable fuel fill check (parameter 6553).</li>
<li>Made it possible to use auto acknowledge on Ext. Comm. Error parameter.</li>
<li>Start attempt maximum limits changed. Extended stop timer minimum limit changed.</li>
<li>Language translation changed. From now on it is not possible to select a different font.  The two fonts are now merged together, and containing all previously used characters. New characters are added. If any unsupported signs are written to the device the signs  will appear as ' ' (space).</li>
<li>Three RMI sensor curves added. One for each RMI type.  It will be possible to choose them in channel 10460, 10630 and 10800 by selecting "Sensor type 4" in the DEIF Multi-line 2 Utility Software v.3.</li>
<li>Scaling range 1 kV - 75 kV changed to 0.4 kV - 75 kV.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Stop coil did not activate when start sequence was aborted.</li>
<li>Inhibit evaluation added to a number of AC alarms.</li>
<li>Missing digit to running hours corrected.</li>
<li>Sign of display values between -1.0...0.0 with one or two decimals shown correctly.</li>
<li>Missing EIC values in analogue delta alarms added.</li>
<li>Measurement through the MPU input caused periodical peaks in the RPM measurement, which could cause an unwanted trip of the generator breaker.</li>
<li>Change of AC scale caused several energy counter views to be displayed with wrong decimal point and unit.</li>
<li>M-Logic line combination misinterpretation corrected.</li>
<li>Application emulation couldn't start properly with breaker and engine commands selected as inactive.</li>
<li>The lower inhibit level for phase sequence error increased from 30 % to 70 % of nominal voltage.</li>
<li>PT sensor offset parameters now corrected to compensate for the cable resistance.</li>
<li>Unit and MTU ADEC(SAM) communication not started during certain power supply situations - corrected. (Updated correction to avoid start request after communication has been reestablished).</li>
<li>M-Logic command "Start and Close GB" was ignored during cool down.</li>
<li>SCANIA EMS2 correction of start/stop.</li>
<li>Clock synchronise over Modbus was causing the service timer to offset its current timer value - corrected.</li>
<li>Configuration of output relays corrected, so all functions can be connected to all available relays.</li>
<li>Selection of multi-inputs for fuel pump logic corrected.</li>
<li>Fuel pump relay could activate at power-up of the controller before fuel level measurement has settled.</li>
<li>Several Modbus (option H2) addresses were not working - corrected.</li>
<li>MTU MDEC 302/303 protocols battery voltage measurement corrected.</li>
<li>Idle run timer now resets at each start attempt.</li>
<li>View lines: Run absolute and energy total corrected.</li>
<li>Unit could reboot if a Modbus command was sent while 'Inhibit modbus commands' was active.</li>
<li>Running hour counter could reset unintendedly - corrected.</li>
<li>Running hour counter could reset unintendedly at power cycle - corrected.</li>
<li>Scania EMS2 KWP2000 log clear now possible.</li>
<li>Exhaust gas temperature - right/left was not shown correctly in display.</li>
<li>Storage of service timer values during reset corrected.</li>
<li>Relays could activate under boot sequence - corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GCU 100 Application Software series 1.xx. &#x2013; v1.02.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gcu-100-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1xx-&#x7CFB;&#x5217;/1-02-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7781aa3f-082c-404d-a973-e7c766aed243</guid>
        <pubDate>2016-03-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GCU 100 Application Software series 1.xx.</category>
        <category domain="version">1.02.1</category>
          <category domain="release-status">current</category>
          <category domain="product">GCU 100</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>When M-Logic cooldown threshold is selected, it will be used regardless if parameter 6214 is 0.</li>
<li>Improved RPM measurement.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>EIC alarms used as low alarms would appear when the CAN communication was lost.</li>
<li>Idle run could cause external start not to work.</li>
<li>Running hour counter offset could be adjusted to more than 99999 hrs.</li>
<li>Engine could end up in an infinite state between crank and running detection.</li>
<li>Alarms added to prevent this:<br />- Running detection reached timer (parameter 6351)<br />- External engine stop detection (parameter 6352)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GPU-3 REC Application Software series 3.x. &#x2013; v3.04.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gpu-3-rec-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-04-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a2da5757-38d9-45f0-8ec4-9e90bdf23dbc</guid>
        <pubDate>2012-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GPU-3 REC Application Software series 3.x.</category>
        <category domain="version">3.04.0</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<h3>Initial version based on GPU-3 with following changes:</h3>
<ul>
<li>Standard relay configurable</li>
<li>Phase sequence protection enable</li>
<li>Option: H1 CANopen added (PDO communication differs from the original H1 option)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 GPU-3 REC Application Software series 3.x. &#x2013; v3.04.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-gpu-3-rec-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-04-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d902f728-8fc8-4a7e-bda8-495265b20505</guid>
        <pubDate>2015-03-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 GPU-3 REC Application Software series 3.x.</category>
        <category domain="version">3.04.1</category>
          <category domain="release-status">current</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Update of self-check functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Marine Application Software series 3.x. &#x2013; v3.12.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x8239;&#x7528;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-12-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8adc1810-c858-42a9-ace6-efdd4c85e589</guid>
        <pubDate>2021-08-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Marine Application Software series 3.x.</category>
        <category domain="version">3.12.3</category>
          <category domain="product">GPU-3</category>
          <category domain="product">PPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>View text for DU-2 available for translation.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Marine Application Software series 3.x. &#x2013; v3.12.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x8239;&#x7528;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-12-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a330e24d-104f-45e5-8f8c-0eb48514be4b</guid>
        <pubDate>2019-08-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Marine Application Software series 3.x.</category>
        <category domain="version">3.12.2</category>
          <category domain="product">GPU-3</category>
          <category domain="product">PPU-3</category>
        <content:encoded><![CDATA[
<p>Version 3.12.2 based on 3.12.1</p>
<h3>Corrections:</h3>
<ul>
<li>Modbus addresses for relay status on EF5-option not active.</li>
<li>PPU-2 protocol converter in PPU-3 not working for Profibus.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Marine Application Software series 3.x. &#x2013; v3.12.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x8239;&#x7528;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-12-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f91c57d1-92d4-4436-aa29-855767f0e833</guid>
        <pubDate>2018-09-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Marine Application Software series 3.x.</category>
        <category domain="version">3.12.1</category>
          <category domain="product">GPU-3</category>
          <category domain="product">PPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Log value disappears after power cycle on display.</li>
<li>Log did not appear in USW before the unit had been power- cycled.</li>
<li>Option M15.8MKII Delta alarms were not available on display.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Marine Application Software series 3.x. &#x2013; v3.12.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x8239;&#x7528;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-12-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1984d392-2b52-4857-af26-070984d9297e</guid>
        <pubDate>2022-03-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Marine Application Software series 3.x.</category>
        <category domain="version">3.12.4</category>
          <category domain="product">GPU-3</category>
          <category domain="product">PPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Running hours shown correct on GPU/PPU-2 Modbus RS-485 / ProfiBus interface.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Marine Application Software series 3.x. &#x2013; v3.12.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x8239;&#x7528;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-12-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2dc0fb58-e4bb-4f6f-b8fc-0bb0ef76400a</guid>
        <pubDate>2023-01-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Marine Application Software series 3.x.</category>
        <category domain="version">3.12.5</category>
          <category domain="release-status">current</category>
          <category domain="product">GPU-3</category>
          <category domain="product">PPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>SWBD CONTROL for status text and event log made translateable.</li>
<li>Start+Sync can now tolerate a dip below OK level on the busbar.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 MDR Application Software Series 1.x. &#x2013; v1.14.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-mdr-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x8F6F;&#x4EF6;/1-14-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">06b9461e-4efb-4367-a187-2cd500be259a</guid>
        <pubDate>2015-05-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 MDR Application Software Series 1.x.</category>
        <category domain="version">1.14.1</category>
          <category domain="release-status">current</category>
          <category domain="product">MDR-1</category>
        <content:encoded><![CDATA[
<ul>
<li>Update of self-check functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 MDR Application Software Series 1.x. &#x2013; v1.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-mdr-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x8F6F;&#x4EF6;/1-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8df2db20-5c4e-4a1c-a60a-94b0d20df865</guid>
        <pubDate>2014-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 MDR Application Software Series 1.x.</category>
        <category domain="version">1.14.0</category>
          <category domain="product">MDR-1</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support of new uP board.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Password max. limit changed to 32000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 MDR Application Software Series 2.x. &#x2013; v2.05.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-mdr-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-05-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">302c57a4-9356-4ee1-8b23-6e96aeb040b2</guid>
        <pubDate>2016-08-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 MDR Application Software Series 2.x.</category>
        <category domain="version">2.05.2</category>
          <category domain="release-status">current</category>
          <category domain="product">MDR-2</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Short circuit might be triggered after a unit reboot</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 MDR Application Software Series 2.x. &#x2013; v2.05.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-mdr-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2x-&#x7CFB;&#x5217;/2-05-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">660b977c-2ba8-45fb-aaed-de71f63dc440</guid>
        <pubDate>2015-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 MDR Application Software Series 2.x.</category>
        <category domain="version">2.05.1</category>
          <category domain="product">MDR-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<p>Update of self-check functionality</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 PPM Application Software series 3.x. &#x2013; v3.08.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ppm-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-08-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf829306-bee1-44cf-b807-a37b6715d055</guid>
        <pubDate>2015-12-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 PPM Application Software series 3.x.</category>
        <category domain="version">3.08.7</category>
          <category domain="product">PPM-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Too many Modbus requests could cause the Modbus communication to stall.</li>
<li>Incorrect fast over-current measurement causing alarm to appear inappropriately.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 PPM Application Software series 3.x. &#x2013; v3.08.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-ppm-&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-08-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">57e85608-415d-423b-800b-afec58c93fd4</guid>
        <pubDate>2016-06-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 PPM Application Software series 3.x.</category>
        <category domain="version">3.08.8</category>
          <category domain="release-status">current</category>
          <category domain="product">PPM-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Optimised heavy consumer calculation</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Profi-Bus GSD-file &#x2013; v1.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-profi-bus-gsd-&#x6587;&#x4EF6;/1-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b56cea96-0d50-4c2c-bbfb-e2a358ff3f09</guid>
        <pubDate>2001-11-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Profi-Bus GSD-file</category>
        <category domain="version">1.00</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">AOP</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPC-3 hydro</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 gas</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">MDR-2</category>
          <category domain="product">PPU-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC-3</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPM-2</category>
          <category domain="product">PPU-2</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - GPC v.2.xx </li>
<li>Multi-line 2 - GPU v.2.xx</li>
<li>Multi-line 2 - PPU v.2.xx</li>
<li>Multi-line 2 product series</li>
<li>This GSD-file is used in connection with the option H3 for a multi-line 2 unit - Profi-Bus communication - and is the initial version. The names of the files are deif0632.gsd and deif0632.dib. The files apply to the standard multi-line 2 application from version 1.50.1 and forward.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 1.7x.x. &#x2013; v1.71.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1-7xx-&#x7CFB;&#x5217;/1-71-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">07295b4b-cf1a-41ab-95ba-5de402d6feeb</guid>
        <pubDate>2011-09-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 1.7x.x.</category>
        <category domain="version">1.71.6</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Running hour counter overflow at 32500hours corrected</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 1.7x.x. &#x2013; v1.71.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-1-7xx-&#x7CFB;&#x5217;/1-71-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c44be3ee-d346-4af9-99e3-aef184ad3a97</guid>
        <pubDate>2015-03-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 1.7x.x.</category>
        <category domain="version">1.71.7</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - GPC v.2.xx</li>
<li>Multi-line 2 - GPU v.2.xx</li>
<li>Multi-line 2 - PPU v.2.xx</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Update of self-check functionality</li>
<li>Could not disable parameters 3010 and 3020 in the USW</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.30.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-30-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">22acbb68-d65c-4f11-b5d8-6d5c3e021aab</guid>
        <pubDate>2004-04-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.30.0</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Option H4 CCM-communication read/write functions extended</li>
<li>Option H4 CCM-comminication heartbeat handling added</li>
<li>Option H5 Can-bus Engine interface implemented, supporting:<br>MDEC 2000/4000 M.302<br>MDEC 2000/4000 M.303<br>DDEC<br>EMR&nbsp;<br>JDEC<br>Volvo Penta</li>
<li>Option H6 Cummins engine communication added</li>
<li>Modbus protocol extended</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Running detection for disconnection of starter is changed</li>
<li>Configurable display text for PT100 added</li>
<li>Some setpoint ranges are extended<br>Option O Waterturbine - minor changes of functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.30.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-30-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c42a99b0-10e0-46b1-bae6-b25c964d7e4b</guid>
        <pubDate>2004-06-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.30.1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Frequency regulator adjusted for perfect performance</li>
<li>Initialisation of loadshare lines are optimised</li>
<li>Run coil functionality adjusted</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.30.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-30-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">15b5371e-7bf0-4b34-9e8a-95422c74e2c0</guid>
        <pubDate>2004-06-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.30.2</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Option H4 CCM: Optimised and extended possibilities</li>
<li>Modbus possibilities extended&nbsp;</li>
<li>Translations of German and Spanish completed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.30.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-30-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">83146ced-7a99-4b37-a998-131c90cdda8d</guid>
        <pubDate>2004-08-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.30.3</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Handling of The emergency stop functionality in regard to option M20 is changed</li>
<li>Reverse power alarm - max timer setting is extended</li>
<li>Alarm messages displayed in USW is now displayed in the chosen Multi-line 2 language</li>
<li>German texts are adjusted</li>
<li>The Modbus ASCII mode is improved</li>
<li>Eventlog view in USW is improved</li>
<li>Update of number of CB operations is changed</li>
<li>Negative sequence voltage functionality improved at high voltages</li>
<li>Possible overflow in scaled analogue input is removed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.31.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-31-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8592d344-3237-41c3-a3f9-c5c271cd07b8</guid>
        <pubDate>2004-11-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.31.0</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>SMS functionality extended</li>
<li>Option H5 - MDEC engine interface extended</li>
<li>Splitphase/single functionality modified</li>
<li>Limit switches functionality extended</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Relay output functionality extended</li>
<li>Analogue current output for AVR/Gov limited</li>
<li>GDU interface adjusted</li>
<li>Some menus in some languages adjusted</li>
<li>Some minor adjustments of set-points limits</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.31.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-31-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">315ac45c-ef90-464e-a8b9-54b945cced62</guid>
        <pubDate>2004-12-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.31.1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Relay3 functionality regarding alarm/reset adjusted</li>
<li>Volvo Penta engine protocol adjusted</li>
<li>Minor changes in menu texts</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.31.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-31-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ca172861-3996-47c0-ae24-4d2131af2188</guid>
        <pubDate>2005-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.31.2</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Handling of asynchron generator changed</li>
<li>Option O - regulators for water-turbines adjusted</li>
<li>Minor changes to menus and min/max settings</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.32.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-32-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b8e17c4b-7d5c-48d9-a94e-d19883987715</guid>
        <pubDate>2005-05-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.32.0</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>CanOpen protocol: Zero-sequence U and I failure added</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>RPM measurements updated</li>
<li>Option O - regulator start adjusted</li>
<li>Minor changes in menus and min/max settings</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.32.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-32-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9604289e-f3de-4cf8-a6c3-e9730b4321f4</guid>
        <pubDate>2005-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.32.1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Water-level regulation updated</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.32.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-32-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5bd9f2f9-268a-47e7-87af-0ca978ac1479</guid>
        <pubDate>2005-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.32.2</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Handling of option C2 - alarms during genset stop sequence changed</li>
<li>Scaling of the controller output shown in the USW changed</li>
<li>Mode-handling via terminal 43 is changed</li>
<li>Handling of downloading changed parameters changed</li>
<li>Option O handling of waterlevel controller changed</li>
<li>Factory settings for negative + zero sequence changed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.32.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-32-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">585e065c-bea9-402b-afb4-566e44860baf</guid>
        <pubDate>2006-01-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.32.4</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Analogue output for PF modified</li>
<li>Interface between USW and GPU settings modified</li>
<li>Menu's for M13 modified</li>
<li>Handling of relay 10...13 modified</li>
<li>MDEC protocol handling modified</li>
<li>GPU - relay-functionality modified</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.32.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-32-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2e687380-78ea-4928-aca1-69af9f248d2b</guid>
        <pubDate>2006-03-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.32.5</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Option O1, cascade control has been trimmed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.32.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-32-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1f6a9c49-cb27-4e37-b413-baa2935c3281</guid>
        <pubDate>2006-04-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.32.6</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Possibility to set option G1 modified</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.40.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-40-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f1f656a1-da13-4f93-9b86-5963de6a11ca</guid>
        <pubDate>2006-08-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.40.0</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Use of step-up transformer.&nbsp;</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.40.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-40-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1c578ef5-c86c-41fc-9f01-fb7ff2c36802</guid>
        <pubDate>2006-10-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.40.1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Accuracy of reactive power measures improved</li>
<li>Accuracy of I&gt;&gt; measure improved</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.41.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-41-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3538ae58-e2fb-49b0-935f-857d979f192b</guid>
        <pubDate>2006-10-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.41.0</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>EF5 option implemented</li>
<li>Handling of option M15 changed</li>
<li>Inhibit of BB alarms U&gt;, f&gt;</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.41.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-41-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">41ff5b99-8910-4c18-b863-fe14328fde4c</guid>
        <pubDate>2007-05-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.41.1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Max setting for starter ON time 180s.</li>
<li>Improved alarm log handling.</li>
<li>Improved vector jump calculation.</li>
<li>Show terminal 43 - 53 at USW only if load share board is present.</li>
<li>Could not access menu 4960 via jump.</li>
<li>USW did not show menu 2275.</li>
<li>Unbalance voltage calculations improved.</li>
<li>Zero sequence calculations improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.41.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-41-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f6bbb3df-71b7-4733-a543-de1ba4e3dbfd</guid>
        <pubDate>2007-05-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.41.2</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Improved frequency protection.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e300ed0b-2a0b-4e28-b3aa-734bc4fc3549</guid>
        <pubDate>2007-08-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.0</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Ramp up in loadshare mode.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>USW did not show password correct if language other than English was selected</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6b7b112e-e079-44eb-b3e5-e007278bc344</guid>
        <pubDate>2007-10-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Protection level "Over load 3" added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>"No Regulation" was logget twice.</li>
<li>Password max limit changed to 32000.</li>
<li>kWh counter output did not work correct after reset of counter value.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">deba9baf-1a8a-42ce-ac08-a08542ab4696</guid>
        <pubDate>2007-11-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.2</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Sync. using step up transformer improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">daa32a62-dbfa-4838-bf48-4c2e5aeebb6d</guid>
        <pubDate>2009-03-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.3</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Writing to control registers no longer depends on H options.</li>
<li>Low current measurements improved.</li>
<li>Handling of synchronizing failure improved</li>
<li>Parameter 2260 is now available in DEIF Utility Software.</li>
<li>Ability to show large negative power improved.</li>
<li>Maximum timer values for stop failure and run status set to 3000 seconds.</li>
<li>Unbalanced current calculations now relates to the nominal current setting.</li>
<li>New modbus measurement (03h) at address 65 indicates PF with sign. Address 11 is without sign.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e0273c38-1a79-417c-9aa5-c861e21d4df1</guid>
        <pubDate>2009-10-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.4</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Df/dt protection improved.</li>
<li>Vector jump protection improved.</li>
<li>Unit psi implemented for analog input</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c20790ef-14c2-4b15-adc9-e8a90e537005</guid>
        <pubDate>2010-02-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.5</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Removed bumb from regulator first time GB closes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">445b64f9-380c-45ea-b57e-266a9a718267</guid>
        <pubDate>2011-04-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.6</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Analogue output (option F2) improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c72b745f-0b43-422b-810c-8ed876970c0c</guid>
        <pubDate>2011-09-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.7</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<ul>
<li>Running hour counter overflow at 32500hours corrected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 2.3x and 2.4x &#x2013; v2.42.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-2-3x-&#x548C;-2-4x-&#x7CFB;&#x5217;/2-42-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c511d014-43f5-43be-adb9-d25943a80477</guid>
        <pubDate>2015-03-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 2.3x and 2.4x</category>
        <category domain="version">2.42.8</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - GPC v.2.xx</li>
<li>Multi-line 2 - GPU v.2.xx</li>
<li>Multi-line 2 - PPU v.2.xx</li>
</ul>
<h3>Change:</h3>
<ul>
<li>Update of self-check functionality</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 3.x. &#x2013; v3.22.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-22-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">59d924c0-4a85-4fdb-9dc0-9d3024b5056a</guid>
        <pubDate>2021-12-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 3.x.</category>
        <category domain="version">3.22.3</category>
          <category domain="product">APU-4</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<p>Version 3.22.3 based on version 3.22.2</p>
<h3>Correction:</h3>
<ul>
<li>Translation now works even though no DU-2 is mounted AND only new language is written.</li>
<li>Configurable Modbus area works correctly even though no DU-2 is mounted.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 3.x. &#x2013; v3.22.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-22-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b22cc762-4afd-449a-960c-bed0541d1f52</guid>
        <pubDate>2019-01-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 3.x.</category>
        <category domain="version">3.22.1</category>
          <category domain="product">APU-4</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Fixes Modbus TCP connection (option N), when an engine protocol is selected on CAN Engine Interface Communication (option H7).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 3.x. &#x2013; v3.22.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-22-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4c69abd8-8b39-4e7d-8255-78073d88b24a</guid>
        <pubDate>2019-08-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 3.x.</category>
        <category domain="version">3.22.2</category>
          <category domain="product">APU-4</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<p>Version 3.22.2 based on version 3.22.1</p>
<h3>Correction:</h3>
<ul>
<li>   Starter now deactivates when the "Remove starter" threshold is reached during start sequence.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Standard Application Software series 3.x. &#x2013; v3.22.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x6807;&#x51C6;&#x5E94;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7CFB;&#x5217;/3-22-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">968d04aa-b351-4985-be7f-7bde706c3598</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Standard Application Software series 3.x.</category>
        <category domain="version">3.22.4</category>
          <category domain="release-status">current</category>
          <category domain="product">APU-4</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPU-3</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Corrected an issue where the wrong set point was calculated for the Q regulator when Island ramp (#2614) was enabled.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.1.x. &#x2013; v1.43.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7248;&#x672C;/1-43-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c63da3ed-6b4e-474a-8c4a-5606375d2ca9</guid>
        <pubDate>2013-04-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.1.x.</category>
        <category domain="version">1.43.0</category>
          <category domain="release-status">current</category>
          <category domain="product">MDR-2</category>
          <category domain="product">AGC-2</category>
          <category domain="product">BGC-2</category>
          <category domain="product">EC-1</category>
          <category domain="product">EC-1M</category>
          <category domain="product">GC-1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">MDR-1</category>
          <category domain="product">PPM-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>Multi-line 2 - AGC v.2.xx</li>
<li>Multi-line 2 - GPC v.2.xx</li>
<li>Multi-line 2 - GPU v.2.xx</li>
<li>Multi-line 2 - PPU v.2.xx</li>
<li>Multi-line 2 - BGC</li>
<li>Multi-line 2 - MDR</li>
<li>Multi-line 2 - EC-1/GC-1</li>
<li>Multi-line 2 - PPM v.2.xx</li>
<li>Multi-line 2 - AGC v.1.xx</li>
</ul>
<h3>New features:</h3>
<ul>
<li>Inclusion of an EULA in the installation script.</li>
<li>Option N configuration tool added to the software package (launchable from USW 1)</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Support for Gempac 2.60.01.43.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.1.x. &#x2013; v1.42.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-1x-&#x7248;&#x672C;/1-42-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">efe27e67-4e4a-4e74-a915-debe7fdfba45</guid>
        <pubDate>2011-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.1.x.</category>
        <category domain="version">1.42.0</category>
          <category domain="product">MDR-2</category>
          <category domain="product">AGC-2</category>
          <category domain="product">BGC-2</category>
          <category domain="product">EC-1</category>
          <category domain="product">EC-1M</category>
          <category domain="product">GC-1</category>
          <category domain="product">GPC-2</category>
          <category domain="product">GPU-2</category>
          <category domain="product">MDR-1</category>
          <category domain="product">PPM-2</category>
          <category domain="product">PPU-2</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>USB driver for 64 bit Windows XP, Vista or 7.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Trending and data tracer improvements.</li>
<li>Improved support of serial to tcp-ip converter.</li>
<li>Irrelevant log columns not included when exporting logs to an Excel file.</li>
<li>Alarm entries updated correctly after Logs retrieva</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.47.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-47-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2ad714de-8634-462c-9657-1f8a8af13495</guid>
        <pubDate>2021-03-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.47.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1808.<br />USW3 product database revision: 7181.</p>
<h3>What's new:</h3>
<p>Support of AGC-4 – 4.81.0<br />Support of AGC-4 Mk II – 6.02.0<br />Support of ASC-4 – 4.16.0</p>
<h3>Corrections:</h3>
<ul>
<li>Solves an issue where importing favorites was not working.</li>
<li>Solves an issue where errors would occur when the PC awakes from sleep mode.</li>
<li>Solves an issue where the parameters from Advanced Protections would not be consistently written to the controller.</li>
<li>Solves an issue where AOP 1 and AOP 2 would be written when cancelling the write operation of M-Logic.</li>
<li>Solves an issue where an Access Violation error would occur when writing to multiple controllers.</li>
<li>Solves an issue where the "Enable" parameter was not written when writing to multiple controllers.</li>
<li>Solves an issue where the IP address would disappear from the bottom status line on some controller types.</li>
<li>Solves an issue where the CIO 116 and CIO 208 could not be configured.</li>
<li>Solves an issue where an error would occur when selecting CIO 116 on some controllers types.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.51.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-51-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4cd889b1-3d6d-48aa-84e0-c3358e2f4b43</guid>
        <pubDate>2021-11-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.51.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1978.<br />USW3 product database revision: 7621.</p>
<h3>New features:</h3>
<ul>
<li>Support for PMS redundancy on AGC 150.</li>
<li>Support for AGC 150 Remote Display variant.</li>
<li>Support for AGC 150 Marine.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>The device page for AGC 150 Hybrid now shows values for the inverter.</li>
<li>The supervision page for AGC 150 Hybrid now shows a generator with a PV panel.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solves an issue that made it difficult to edit numeric fields.</li>
<li>Solves an issue that made toolbars seem to not be present.</li>
<li>Solves an issue that caused corruption to special characters on export of Translations to a CSV file.</li>
<li>Solves an issue on I/O Setup occurring when opening a .usw file of AGC 150 and AGC-4 Mk II.</li>
<li>Solves reported issues of support for special character handling in several pages.</li>
<li>Solves an issue leading to errors in the graphs of the VRT tabs in Advanced Protections.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.47.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-47-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">79261d46-dd52-4a4a-a1e1-72fa3b469e57</guid>
        <pubDate>2021-01-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.47.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1743.<br />USW3 product database revision: 6991.</p>
<h3>What's new:</h3>
<p><br />  • AGC-4 Mk II release:<br />  • Support for Application SW download.<br />  • New bootloader available for AGC-4 Mk II.<br /><br />  • New I/O setup page for AGC 150 and AGC-4 Mk II:<br />  • The I/O configuration toolbar button and respective page have been deprecated for the mentioned products.<br />  • The input alarm and relay configuration functions have been removed from the parameter list for the mentioned products.<br />  • Digital input and multi-input functions and alarms are now placed in tabs on the I/O setup page, accessible from the main navigation menu on the right side of the window.<br />  • Output functions and configuration are now placed in a single tab on the I/O setup page.<br /><br />  • CIO input/output function setup:<br />  • Due to the removal of the I/O configuration pop-up, CIO116 and CIO208 functions can be selected in the CIO configuration page.<br />  • The support for functions on CIO308 multi-inputs is not supported by this release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.47.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-47-2-pdb7240/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7cbc19eb-3522-44a1-8139-c1ac0b60cfb1</guid>
        <pubDate>2021-04-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.47.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1808.<br />USW3 product database revision: 7240.</p>
<h3>What's new:</h3>
<p>Support of AGC150 – 1.06.0.</p>
<h3>New features:</h3>
<ul>
<li>Added AGC150 Engine drive variant.</li>
<li>Added fallback timer for power limit on SunSpec (parameter 17180).</li>
<li>Added support for Keyswitch in I/O setup.</li>
<li>Added support of PV breaker.</li>
<li>Added EIC and MPU speed to delta alarms.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.45.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-45-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ef4db4dc-b2e7-4224-85c4-7e1ff15f89b2</guid>
        <pubDate>2020-03-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.45.3</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1490<br />USW3 product database revision: 6360</p>
<h3>New:</h3>
<ul>
<li>Adds support of upcoming AGC 150 version 1.02.0.</li>
<li>Adds support of upcoming AGC 150 version 1.03.0.</li>
<li>Adds support of upcoming AGC-4 version 4.77.0.</li>
<li>Adds support of upcoming ASC-4 version 4.12.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.45.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-45-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e7920165-5928-41cb-9139-d2bedc468e7d</guid>
        <pubDate>2020-09-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.45.4</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1518<br />USW3 product database revision: 6586</p>
<h3>What's new:</h3>
<ul>
<li>Adds support of upcoming AGC 150 Hybrid.</li>
<li>Adds support of upcoming AGC-4 version 4.79.0.</li>
<li>Adds support of upcoming ASC-4 version 4.14.0.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solved issue with CIO alarm setpoint shown as zero.</li>
<li>Solved issue where AGC 150 multi input alarm delays were possible to set outside the allowed range.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.50.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-50-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cbe6059c-dbc8-4dcd-a0f7-66edda498022</guid>
        <pubDate>2021-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.50.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1849<br />USW3 product database revision: 7312</p>
<h3>Changes:</h3>
<ul>
<li>Validation of CIO 208 configuration written to the controller<br />
<ul>
<li>In some cases, the controller may reject the configuration set by the user.</li>
<li>The Write function now reads back from the controller and notifies the user in case of disparity between the user selections and the controller.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue causing failures to read the CIO configuration in Batch Read.</li>
<li>Fixed an issue where some drivers had a wrong digital signature.</li>
<li>Fixed an issue where multi-input scaling would change back to "DegC 1/1" after writing to the controller.</li>
<li>Fixed an issue where Batch Read and Batch Write would not work properly for Multi-input settings.</li>
<li>Fixed an issue where the RMI configuration would be lost when using the Batch Write functionality.</li>
<li>Fixed an issue where the Batch job would finish but the pop-up would not accurately depict the progress.</li>
<li>Other small fixes and performance improvements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.50.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-50-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">01db3fe1-6aca-42cc-b7ab-1ececd9f5243</guid>
        <pubDate>2021-07-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.50.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1880<br />USW3 product database revision: 7366</p>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue that prevented users from scaling the multi-inputs.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.51.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-51-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">549db572-5c0c-4e00-8fbb-2cc6be081722</guid>
        <pubDate>2021-12-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.51.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1978.<br />USW3 product database revision: 7679.</p>
<h3>New features:</h3>
<ul>
<li>Support of AGC 150 – 1.09.0</li>
<li>Support of ASC-4 – 4.20.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.51.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-51-0-pdb7845/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">26383e89-0ad1-40e1-9f22-207430e1d542</guid>
        <pubDate>2022-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.51.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 1978.<br />USW3 product database revision: 7845.</p>
<h3>New features:</h3>
<ul>
<li>Support of AGC 150 – 1.10.0</li>
<li>Support of ASC-4 – 4.21.0</li>
<li>Support of AGC-4 Mk II – 6.06.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.52.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-52-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">26917437-9a6c-4d87-9b63-a6b6322fae6f</guid>
        <pubDate>2022-02-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.52.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2123.<br />USW3 product database revision: 7880.</p>
<h3>New features:</h3>
<ul>
<li>Added Support for IEEE 1547 on selected controllers.</li>
<li>Added fields to Identifiers window to meet dataplate requirements of IEEE 1547.</li>
<li>Added configuration parameters and their graphical representation on the Advanced Protections page.</li>
<li>Added parameter validation to meet the configuration requirements of IEEE 1547.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Changed graph component to support new features and requirements.</li>
<li>Changed spinedit component to support new features and requirements.</li>
<li>Identifiers window content is now always read when opening the window.</li>
<li>Identifiers window now asks for confirmation when it is being closed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue causing the Inverter Data page to freeze when opening.</li>
<li>Fixed an issue where the slider value would work irregularly.</li>
<li>Fixed an issue that caused a crash when the IP address was not available.</li>
<li>Fixed an issue for an illegal data value error when writing Multi-Inputs.</li>
<li>Fixed an issue that caused the language selection to not be available.</li>
<li>Fixed an issue where setpoint 3 was not available for RMI inputs.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.53.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-53-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bcc04e1b-1e56-466c-9ce5-cb44bc345b7b</guid>
        <pubDate>2022-04-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.53.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2186</p>
<p>USW3 product database revision: 7957</p>
<h3>New features:</h3>
<ul>
<li>Added Portuguese (Brazil) localization.</li>
<li>Reduced repeated lists on the Product Database.</li>
<li>Button to open/close the M-Logic toolbox.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>New ProductIDs in USW V.3.53.0.</li>
<li>Russian language for Views.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>USW crashing with Floating-point overflow.</li>
<li>Expand buttons disappear when using "Copy to the line below" (AGC 4 and AGC150).</li>
<li>Mismatch column in parameter tab is not present corrections.</li>
<li>Parameter disappears after changing Parameter 7841.</li>
<li>Spinedit component resolution does not respect the decimals attribute.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.53.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-53-0-8174/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cc6a2e3d-3714-44b3-b0e4-d625a54f286a</guid>
        <pubDate>2022-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.53.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2186.<br />USW3 product database revision: 8174.</p>
<h3>Changes:</h3>
<ul>
<li>Support of AGC 150 – 1.11.0</li>
<li>Support of ASC-4 – 4.22.0</li>
<li>Support of AGC-4 Mk II – 6.07.0</li>
<li>New Launcher page for selected products.</li>
<li>New Menu bar for selected products.</li>
<li>Ability to save and load sensors via customer files</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.54.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-54-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">40476470-33ec-454c-b6d8-930a6fde2d91</guid>
        <pubDate>2022-08-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.54.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2320<br />USW3 product database revision: 8322</p>
<h3>New Feature</h3>
<ul>
<li>Added provision to edit and save sensor curves for multi Inputs and CIO</li>
<li>Added pre-defined sensor curve</li>
<li>New launcher window</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Left-side navigation menu style</li>
<li>Change symbol in USW</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Batch write crash issue.</li>
<li>Russian language.</li>
<li>USB driver signing issue.</li>
<li>M-logic will overwrite other saved items</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.54.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-54-0-8363/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b6b416b8-67ae-4f00-8365-5516cfe5c029</guid>
        <pubDate>2022-09-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.54.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2320.<br />USW3 product database revision: 8363.</p>
<h3>New features:</h3>
<ul>
<li>Support of AGC 150 – 1.12.0</li>
<li>Support of ASC-4 – 4.23.0</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.54.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-54-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7d0fe2d3-5f0e-4936-be61-259203204cec</guid>
        <pubDate>2022-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.54.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2362<br />USW3 product database revision: 8516</p>
<h3>Changes:</h3>
<p>- USW Connection Handling.<br />- Sensor curve open &amp; close hyperlink text colour.<br />- RMI Type Selection in multi-input available again.</p>
<h3>Corrections:</h3>
<p>- Enhanced performance for "Inverterdata".<br />- AGC-4 Mk II function drop-down disabled for breaker feedback.<br />- RMI Scaling in multi-input fixed.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.55.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-55-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7f65766a-5cb6-4f2b-b43a-8fc821cae84c</guid>
        <pubDate>2023-01-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.55.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW-3 build version: 2457<br />USW-3 product database revision: 8666</p>
<h3>New features</h3>
<ul>
<li>Selective reading/writing of M-Logic and AOP.</li>
<li>CIO configuration moved from pop-up to a dedicated page.</li>
<li>Parameter tree view improvements:
<ul>
<li>Collapsible panels</li>
<li>Search function</li>
<li>Parameter number</li>
<li>Tree structure improved</li>
</ul>
</li>
<li>New pop-up for disconnect function.</li>
<li>Support of 5 CIO 308 modules for AGC-4 Mk II.</li>
<li>Support of 5 CIO 208 modules for AGC-4 Mk II.</li>
<li>Support of 5 CIO 116 modules for AGC-4 Mk II.</li>
<li>Multi-input: Added selection for the number of points in the configurable sensor curve.</li>
<li>Multi-input: Changed open &amp; close text hyperlink to button.</li>
<li>Translation folder created in app data location with language files.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated sensor files.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Every time advanced protection parameters are read, the USW reports that the connection timed out.</li>
<li>Question marks in I/O setup from old controller.</li>
<li>USW disconnects when another power management unit is missing.</li>
<li>Code ANSI zero sequence current/voltage corrected in mouse-over text for parameters.<br /><br /></li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.56.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-56-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c4c45319-7259-48a0-a1b6-739ed4f35904</guid>
        <pubDate>2023-02-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.56.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2516</p>
<p>USW3 product database revision: 8789</p>
<h3>New features</h3>
<ul>
<li>Live value available from the "Parameters" page in tree view mode.</li>
<li>New translation files are added to the translation folder.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Moved "Permissions" icon to the left menu under "Tools". It is still called "Permissions".</li>
<li>Moved "PID Configuration" icon to the left menu under "Tools". Renamed to "General Purpose PID”.</li>
<li>Moved "Modbus Configuration" icon to the left menu under "Tools". The name is the same.</li>
<li>Added "Firmware" to the "Option" page. Renamed "Option" to "Option &amp; firmware”.</li>
<li>"Device Information" is now available from the "Option &amp; firmware" page.</li>
<li>Optimised the tree view text.</li>
<li>Moved "N-Option" icon to the left menu under "Tools". Renamed to "Ethernet Setting (Modbus TCP/IP)".</li>
<li>Changed "Open &amp; Close" hyperlink to button icon.</li>
<li>Changed the maximum number of languages for AGC 150 to 8.</li>
<li>Moved "Translations" from "Configuration" to "Tools".</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Optimised the menu bars and windows.</li>
<li>Optimised the connection with the controller.</li>
<li>Fixed "Write to plant" function.</li>
<li>Fixed sensor scaling and curve for multi-input AGC 150 DG.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.57.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-57-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9911ecb0-0adb-48b4-a568-16d2653cadc2</guid>
        <pubDate>2023-07-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.57.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2686</p>
<p>USW3 product database revision: 9157</p>
<h3>New features</h3>
<ul>
<li>Added offline configuration comparison tool.</li>
<li>Added new device page for PMS Lite.</li>
<li>Added new application supervision for PMS Lite.</li>
<li>Added option to open and save sensor curve file in AGC 150 Engine drive, AGC 150 Engine drive marine, AGC 150 Generator marine, AGC 4 Mk II Genset.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed access violation error when function keys F4 and F5 are pushed too quickly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.57.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-57-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a76692d4-a855-4d6f-997a-63c67f7dca74</guid>
        <pubDate>2023-09-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.57.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2715</p>
<p><br />USW3 product database revision: 9215</p>
<p> </p>
<h3>Corrections</h3>
<ul>
<li> Batch read and write fixed</li>
<li>Other bugs fixed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.58.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-58-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">76377c4c-4d4e-4d47-a6ed-b6d6ac34e95f</guid>
        <pubDate>2023-09-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.58.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2752</p>
<p>USW3 product database revision: 9374</p>
<h3>New features</h3>
<p>• Added data logging status.<br />• Added dynamic table for PMS lite application supervision.<br />• Dynamic parameter based on configurational value to show relevant parameters.</p>
<p> </p>
<h3>Corrections</h3>
<p>• Improved batch write function.<br />• Fixed translation issues.<br />• Fixed issue with opening general purpose PID.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.58.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-58-0-9675/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d8e07eb6-c990-42e6-97ef-5ce5010313bf</guid>
        <pubDate>2023-12-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.58.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2752</p>
<p>USW3 product database revision: 9675</p>
<h3>New features</h3>
<ul>
<li>Added support for AGC 150 – 1.18.0.</li>
<li>Added support for ASC-4 – 4.27.0.</li>
<li>Added support for AGC-4 Mk II – 6.12.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.59.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-59-0-10079/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">79f4d7dd-ec01-40eb-a0e3-754912be28c7</guid>
        <pubDate>2024-02-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.59.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2814</p>
<p>USW3 product database revision: 10079</p>
<h3>New features</h3>
<ul>
<li>Added separate page for ECU and DVC configuration.</li>
</ul>
<h3>Improvements</h3>
<h4>USW performance improvements:</h4>
<ul>
<li>M-Logic &amp; AOP handling.</li>
<li>.Trend file handling.</li>
<li>Parameter tree structure.</li>
<li>Alarm update in USW.</li>
<li>USW message pop-up.</li>
<li>Batch read and write.</li>
<li>Offline file handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.59.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-59-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">78b69a56-7a3a-4862-ba2a-d9185ab1f150</guid>
        <pubDate>2024-04-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.59.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2851</p>
<p><br />USW3 product database revision: 10229</p>
<p> </p>
<h3>Corrections</h3>
<p>• Correction to permissions write during batch write.<br />• AOP-2 emulated button corrected.<br />• M-Logic delay timer was not written to the controller.<br />• M-Logic items in use showing wrong counting.<br />• M-Logic and AOP in use button not showing active M-Logic lines with offline files.<br />• M-Logic and AOP in use button showing wrong interpretation for Virtual event output.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-60-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3b4a8b44-33df-4530-8ddf-82894fdd3880</guid>
        <pubDate>2024-06-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2912</p>
<p>USW3 product database revision: 10488</p>
<p>&nbsp;</p>
<h3>New Features</h3>
<p>&nbsp;• New way of handling translations.<br>&nbsp;• Search Function &amp; Description in M-Logic.<br>&nbsp;• Live value on USW pages.<br>&nbsp;• Live value on ECU &amp; D-AVR pages.</p>
<h3><br>&nbsp;&nbsp;<br>Improvements</h3>
<p>&nbsp;• Improved handling of Power Meter &amp; Inverter Data<br>&nbsp;• Enabling AOP2 based on software package.</p>
<h3>&nbsp;&nbsp;<br>Corrections</h3>
<p>&nbsp;• 'Access Violation' error when trying to change the password level.<br>&nbsp;• M logic &amp; AOP Print option enabled.<br>&nbsp;• Menu text overlapping.<br>&nbsp;• Access violation.t.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-60-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">12fe1e3a-544d-445a-9e22-9d6af116d90b</guid>
        <pubDate>2024-06-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2925</p>
<p>USW3 product database revision: 10644</p>
<h3>Corrections</h3>
<p>&nbsp; • &nbsp;Improved the functionality of the "Write to all" parameter.<br>&nbsp; • &nbsp;Ensured compatibility for parameter files between USW 3.59.1 and 3.60.0.<br>&nbsp; • &nbsp;Fixed an issue with the storage of some translation texts in controllers.<br>&nbsp; • &nbsp;Verified and tested batch job stability for CIO in AGC 4 MK I.</p>
<p>&nbsp;</p>
<h3>Changes</h3>
<p>&nbsp; • &nbsp;Implemented handling for missing Cio.xml files in ASC-4 Battery controllers and others.</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-60-1-10688/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">79842d3b-4ac2-4644-867c-2416bfa61537</guid>
        <pubDate>2024-07-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2925.<br>USW3 product database revision: 10688.</p>
<h3>New features</h3>
<ul>
<li>Support of AGC 150 version 1.20.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-602/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">96292020-d91e-4682-8829-280dde659d4c</guid>
        <pubDate>2024-09-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 2983<br>USW3 product database revision: 10810</p>
<h3>Improvements</h3>
<ul>
<li>Enhanced the graph to support improved dragging and scrolling for better usability.</li>
<li>Refined the display of the live bus bar within the USW application supervision for more accurate monitoring.</li>
<li>Updated the supervision page to enable proper command functionality when solar is added to load points.</li>
<li>Extended compatibility for Ring busbar configurations to ensure support across legacy PMS IDs for ASC-4 and ASC 150 systems.</li>
<li>Enhanced translation encoding when writing to AGC 150 controllers for better text accuracy.</li>
<li>Adjusted the layout to prevent overlapping measurement data when PV / Battery is added to the load point.</li>
<li>Improved compatibility and consistency across M-Logic versions.</li>
<li>Refined the handling of modified command register addresses for improved system response.</li>
<li>Streamlined the AGC 150 firmware upgrade process to reduce delays.</li>
</ul>
<h3>Correction</h3>
<ul>
<li>Corrected symbol display on the PPM-3 Shore device page when using offline files.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-60-2-10901/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6494f8bb-7eb9-400b-b84f-1b59f6e1bb21</guid>
        <pubDate>2024-10-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2983<br>USW3 product database revision: 10901.</p>
<h3>New features</h3>
<ul>
<li>Support of AGC-4 Mk II – 6.14.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-60-2-10963/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fe9cc87d-2043-4ac2-a819-881729ed3e24</guid>
        <pubDate>2024-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2983<br>USW3 product database revision: 10963</p>
<h3>New features</h3>
<ul>
<li>Support of AGC 150 – 1.21.0.</li>
<li>Improved application supervision in USW-3 for iE 250 systems.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.60.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-60-2-11101/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">93e94354-9106-4c6d-bba4-ddf630ba63a8</guid>
        <pubDate>2025-01-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.60.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build version: 2983<br>USW3 product database revision: 11101</p>
<h3>New features</h3>
<ul>
<li>Support of AGC 150 – 1.22.0.</li>
<li>Support of AGC-4 Mk II - 6.15.0.</li>
<li>Support of ASC-4 - 4.29.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.61.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-61-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">666d617e-6561-48b6-88ed-6f23c79808d3</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.61.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>This update brings new scheduler functionality, significant improvement to comparison tool, support for iE 150 Marine, along with improvements and bug fixes that enhance software stability and performance.</p>
<h3>New features</h3>
<ul>
<li>Comparison tools have been updated with more compare functions.</li>
<li>M-Logic search function has been improved including descriptions and faster clearing speed.</li>
<li>Support for iE 150 Marine variants.</li>
<li>Live values enhancements.</li>
<li>New Scheduler page.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added confirmation message when I/O settings are written successfully.</li>
<li>Resolved access violation errors in configuration, plant emulation and file comparison.</li>
<li>Fixed configuration issues with CIO 208 modules 4 and 5.</li>
<li>Corrected batch write issues in combined engine and network configuration.</li>
<li>Fixed AGC 150 translation prompt issue due to version mismatch.</li>
<li>Application supervision now shows correct status for active PV.</li>
<li>Restored missing BTB redundant option for AGC-4 Mk II.</li>
<li>Fixed special character corruption in translations.</li>
<li>Resolved translation read issue.</li>
<li>Fixed "Save All" function in USW 3.60.2.</li>
<li>Corrected software revision in identifiers.</li>
<li>Resolved incorrect Inhibit settings.</li>
<li>Resolved project closing issues in Advanced Protection/ECU &amp; DAVR configuration.</li>
<li>Updated footer connect name display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.61.0 PDB 11353</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-61-0-11353/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3ffe611a-dcb8-4648-a6ce-a6e438be551a</guid>
        <pubDate>2025-03-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.61.0 PDB 11353</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for AGC-4 Mk II - 6.20.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.62.0 PDB 11519</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-62-0-11519/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">791f5772-6357-4336-9132-7799dfa086e6</guid>
        <pubDate>2025-05-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.62.0 PDB 11519</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 3151<br>USW3 product database revision: 11519</p>
<h3>New features &amp; improvements</h3>
<ul>
<li>Moved display views configuration to a dedicated page. &nbsp; &nbsp;</li>
<li>Introduced a third party integration page and dedicated IO page.</li>
<li>Added advanced filtering capabilities, including EIC Viewline and tag-based filters.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Improved page behavior for data persistency and automatic data read.</li>
<li>Standardized behavior when switching between pages.</li>
<li>Fixed crash when changing password level.</li>
<li>Resolved issues with data tracer and parameters tree view</li>
<li>Restored visibility of M-Logic from older ECU 100 controllers.</li>
<li>Corrected source measurement updates in plant control.</li>
<li>Fixed permission handling for digital outputs in AGC 150/iE 150 setups.</li>
<li>Ensured 'start engine' command is visible in application supervision.</li>
<li>Resolved missing options in the batch file interface.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.62.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-62-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0ee67bd7-4727-48c4-9ea7-746460300854</guid>
        <pubDate>2025-06-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.62.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 3169<br>USW3 product database revision: 11593</p>
<h3>Corrections</h3>
<ul>
<li>Resolved crash when using certain keywords in search.</li>
<li>Fixed issue where generators could disappear from the application.</li>
<li>Addressed drag-and-drop issues in M-Logic.</li>
<li>Restored missing translations on AGC-4 Mk I, ALC-4, ASC-4 and AGC 5C.</li>
<li>Fixed collapsed tags in the trending view.</li>
<li>Resolved crash when using filters in the AOP logic drop-down.</li>
<li>Fixed issue where M-Logic content disappeared when filtering and using move line up/down.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.62.1 PDB 11714</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-62-1-11714/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">333614ee-03b0-41b7-82b1-12dfb6ced5f8</guid>
        <pubDate>2025-07-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.62.1 PDB 11714</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 3169<br>USW3 product database revision: 11714</p>
<h3>Updates</h3>
<ul>
<li>Updated support for new controller firmware for iE 150 – 1.33.0</li>
<li>Updated support for new controller firmware for AGC-4 Mk II - 6.22.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.63.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-63-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ccd4329d-c3b0-4f0d-9e7a-c0ee9cb02917</guid>
        <pubDate>2025-09-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.63.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 3205<br>USW3 product database revision: 11831</p>
<h3>New features and improvements</h3>
<ul>
<li>Added dynamic filtering based on controller configuration (single or standard) for M-Logic and Display views.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved issue where the scroll bar overlapped with drop-down lists in the permission window.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.64.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-64-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">74de7db7-6619-4a85-b6f9-a73fec69e30e</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.64.0</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 3215<br>USW3 product database revision: 11962</p>
<h3>New features and improvements</h3>
<ul>
<li>PMS Lite Update
<ul>
<li>Now supports up to 254 gensets. Enables large applications with advanced load sharing and start/stop control.</li>
<li>Support for bus tie breakers. Bus tie breakers can now be assigned within PMS Lite for flexible system setups.</li>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.64.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-64-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">447bf34a-9cc1-42d9-afec-95d03a409065</guid>
        <pubDate>2025-10-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.64.1</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>USW3 build revision: 3221<br>USW3 product database revision: 11993</p>
<h3>Corrections</h3>
<ul>
<li>Corrected a problem with the text display in the AGC-4 Mk II</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.64.1 PDB 12031</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-64-1-12031/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">896b6429-26c1-40b4-b956-0942e06b4b05</guid>
        <pubDate>2025-10-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.64.1 PDB 12031</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<ul>
<li>Support for iE 150 (v. 1.35.0)</li>
<li>Support for AGC-4 Mk II (v. 6.23.0)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.64.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-64-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9b6623ee-627f-4ac0-b181-7523156d299e</guid>
        <pubDate>2025-11-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.64.2</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<h3>Bug fixes</h3>
<ul>
<li>Standard application settings no longer carry over when working in a SINGLE genset controller setup. The configuration now stays consistent with the selected mode.</li>
<li>Batch write jobs now handle multi-input sections correctly. Writes complete as expected.</li>
<li>German characters in the status text, such as “DG Blocked for start”, are now shown correctly on both the Device page and the Application Supervision page.</li>
<li>Alarm log entries using German characters are now read and displayed properly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.64.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-64-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">48e3f770-d012-4b79-a2c6-304cc3e2b6b1</guid>
        <pubDate>2025-12-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.64.3</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where texts containing German characters were interpreted incorrectly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 2 Utility Software v.3.x. &#x2013; v3.64.3 PDB 12236</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-2-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;-3x-&#x7248;&#x672C;/3-64-3-12236/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">45e1702d-edde-4806-b85a-9f2380458a81</guid>
        <pubDate>2026-01-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 2 Utility Software v.3.x.</category>
        <category domain="version">3.64.3 PDB 12236</category>
          <category domain="release-status">current</category>
          <category domain="product">AGC 150 ATS Controller</category>
          <category domain="product">AGC 150 BTB</category>
          <category domain="product">AGC 150 Engine Drive</category>
          <category domain="product">AGC 150 Engine Drive Marine</category>
          <category domain="product">AGC 150 Generator</category>
          <category domain="product">AGC 150 Generator - Stand alone</category>
          <category domain="product">AGC 150 Generator Marine</category>
          <category domain="product">AGC 150 Hybrid</category>
          <category domain="product">AGC 150 Mains</category>
          <category domain="product">AGC 150 PMS Lite</category>
          <category domain="product">AGC-4 Mk II</category>
          <category domain="product">ALC-4</category>
          <category domain="product">APU-4</category>
          <category domain="product">ASC 150 Solar</category>
          <category domain="product">ASC 150 Storage</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">CIO 116</category>
          <category domain="product">CIO 208</category>
          <category domain="product">CIO 308</category>
          <category domain="product">GPC-3</category>
          <category domain="product">GPC-3 gas</category>
          <category domain="product">GPU-3</category>
          <category domain="product">GPU-3 hydro</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
          <category domain="product">PPU-3</category>
          <category domain="product">USW-3</category>
          <category domain="product">AFC plant management</category>
          <category domain="product">AGC 200</category>
          <category domain="product">AGC-3</category>
          <category domain="product">CGC 200</category>
          <category domain="product">CGC 400</category>
          <category domain="product">ECU 100</category>
          <category domain="product">GC-1F</category>
          <category domain="product">GCU 100</category>
          <category domain="product">PPM-3</category>
          <category domain="product">AGC plant management</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<ul>
<li>Support of iE 150 (v. 1.36.0)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 Board Support Package (BSP) &#x2013; v3.0.1.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-bsp-for-pcm31/3-0-1-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d3e55da7-a6a4-45da-a241-9681a79d857d</guid>
        <pubDate>2021-10-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 Board Support Package (BSP)</category>
        <category domain="version">3.0.1.3</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>BSP for PCM3.1 for Multi-line 300, PPM 300, PPU 300</li>
<li>NOT suitable for AMC300</li>
</ul>
<h3>New features:</h3>
<ul>
<li>ERPS-network issues fixed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 Board Support Package (BSP) &#x2013; v3.0.1.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-bsp-for-pcm31/3-0-1-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0705ef80-4466-47d6-b580-69d52bbd0d03</guid>
        <pubDate>2022-05-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 Board Support Package (BSP)</category>
        <category domain="version">3.0.1.4</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue where the discovery service would stop working and the units would not be visible in PICUS.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 Board Support Package (BSP) &#x2013; v3.0.1.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-bsp-for-pcm31/3-0-1-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">09d44e75-d26a-430a-af84-a24a995edd70</guid>
        <pubDate>2022-09-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 Board Support Package (BSP)</category>
        <category domain="version">3.0.1.5</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Fixed a rare issue in the Linux kernel where Modbus would stop working due to a NULL pointer error in Syslog.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 Board Support Package (BSP) &#x2013; v3.0.1.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-bsp-for-pcm31/3-0-1-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bafd0453-5b87-488e-af13-a7b9597805e9</guid>
        <pubDate>2024-06-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 Board Support Package (BSP)</category>
        <category domain="version">3.0.1.6</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<p>Corrected triggering of 'DEIF Network redundancy' alarm&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 CODESYS-Add-on &#x2013; v1.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-codesys-&#x6269;&#x5C55;&#x5305;/1-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c2323f39-0bd6-4345-b4d0-162cda459de0</guid>
        <pubDate>2021-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 CODESYS-Add-on</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.3.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>This packet consist of:</h3>
<ul>
<li>Add-on (Runtime <span>3.5.15.20</span>)</li>
<li>Device description</li>
</ul>
<h3>New features:</h3>
<ul>
<li>CODESYS RTE is updated from v3.5.10.0 to v3.5.15.20.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Fixed an issue where CODESYS IDE would timeout when downloading the application.</li>
<li>Fixed an issue where Modbus would not always start on a controller with CODESYS.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 CODESYS-Add-on &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-codesys-&#x6269;&#x5C55;&#x5305;/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c08086d8-1c3e-4b0a-baf7-baf7ec858373</guid>
        <pubDate>2020-02-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 CODESYS-Add-on</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.2.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>This packet consist of:</h3>
<ul>
<li>Add-on (Runtime<span> 3.5.15.20</span>)</li>
<li>Device description</li>
</ul>
<h3>New features:</h3>
<ul>
<li>Support for SD card.</li>
<li>Support for local gateway.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 CODESYS-Add-on &#x2013; v1.0.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-codesys-&#x6269;&#x5C55;&#x5305;/1-0-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">14723138-2053-4165-a9a0-d545ca9e807d</guid>
        <pubDate>2022-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 CODESYS-Add-on</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.3.1</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>This packet consist of:</h3>
<ul>
<li>Add-on (Runtime <span>3.5.15.20</span>)</li>
<li>Device description</li>
</ul>
<h3>New features:</h3>
<ul>
<li>Added the UseFuctionBlock input to all FunctionBlocks to allow for their optional execution.<br />
<ul>
<li>It is now possible to add functions without requiring the respective modules to be installed.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Log size was increased to improve debug capabilities in CODESYS.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 CODESYS-Add-on &#x2013; v1.0.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-codesys-&#x6269;&#x5C55;&#x5305;/1-0-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">92a1061d-b081-4653-9329-84bd6046d1aa</guid>
        <pubDate>2023-08-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 CODESYS-Add-on</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.5.0</category>
          <category domain="release-status">current</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>This packet consist of:</h3>
<ul>
<li>Add-on (Runtime 3.5.15.20)</li>
<li>Device description</li>
</ul>
<h3>New features:</h3>
<p>     • Updated CODESYS add-on to v3.5.18.20.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 CODESYS-Add-on &#x2013; v1.0.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-codesys-&#x6269;&#x5C55;&#x5305;/1-0-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d9156903-bd2b-4c08-83cf-8537d2f72e8e</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 CODESYS-Add-on</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.6.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h2>[1.0.6.0] - 2025-01-21</h2>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS add-on to v3.5.20.40.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7d489a66-bdc7-45d3-9845-23b5f5faa518</guid>
        <pubDate>2021-01-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.14.0</category>
        <content:encoded><![CDATA[
<h2>New features:</h2>
<ul>
<li>Custom alarm action suppression: It is now possible to enable alarm suppression for custom alarms from the display.</li>
<li>Fast data interface: Faster update rate of gauges, counters, status texts, and live data views.</li>
<li>Engine communication:<br />
<ul>
<li>J1939 alarms and historical events.</li>
<li>Fieldbus, configuration, supervision and CANbus error handling.</li>
</ul>
</li>
</ul>
<h2>Corrections:</h2>
<ul>
<li>Fixed translation of texts in the View designer.</li>
<li>Fixed translation of message box popup breadcrumb.</li>
<li>Fixed DU300 live data subheader text cutting lower case p, g, j, q, y letters.</li>
<li>Fixed DU300 showing negative ampere.</li>
<li>Fixed conversion between C and F not having effect on scaling (View design).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d885d637-f0e0-4676-a362-3d2db3cf248c</guid>
        <pubDate>2020-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.13.0</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support of IOM3.2 and IOM3.3.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.13.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ff27589a-6dfb-4669-9c40-330393d1a6e4</guid>
        <pubDate>2020-08-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.13.1</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li> Change default DU300 font to Noto sans</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Not converting set point and hysteresis to F on custom alarms</li>
<li>Memory leak during PPU 300 long term test</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6298e6ea-e6ee-467f-a2ea-a26dc9ed6ebb</guid>
        <pubDate>2021-02-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.15.0</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.15.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/10151/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">791e31b6-0bcf-4de2-8425-beea524e290c</guid>
        <pubDate>2021-07-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.15.1</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Font size and duration of error message increased in the virtual keyboard.</li>
<li>New counters icon for alignment with PICUS.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>"Missing" counters removed from the display.</li>
<li>Units shown for the I/O terminals.</li>
<li>Counters are now limited based on the counter type.</li>
<li>Display restarts on I/O pages when fieldbus configuration is updated.</li>
<li>LED's no longer light up before the screens become active.</li>
<li>Passwords with special characters can now be used from the display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b74ada50-f44f-4088-be3d-e84312ebee30</guid>
        <pubDate>2021-10-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.16.0</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support for Tags:<br />
<ul>
<li>New menu for options to display the tags set in parameters.</li>
<li>Options for tag visualisation include: Alarm pop-up, alarm list, logs page and parameter page.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Update to languages</li>
<li>Connection improvements</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solves an issue where the display could enter a manual loop after returning from synchroscope.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ea1b32ea-19b2-461d-a048-84ab1d8be72f</guid>
        <pubDate>2022-01-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.17.0</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Improved navigation and look of the Parameters page.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solved an issue that would cause the DU 300 to crash when downgrading DU software.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2ce99adf-7c11-4c7d-a286-a760f8e9b3e4</guid>
        <pubDate>2022-04-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.18.0</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>DU300 button management. <br />
<ul>
<li>Added the ability to disable (and enable) the buttons of the DU300 by parameters.</li>
<li>The buttons are disabled in blocks related to their functionality.</li>
<li>This provides more possibilities to configure the controller to the application's requirements.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue with the differentiation of two synchroscopes with the same measurements, like an EDG.</li>
<li>Fixed an issue related to ANSI codes shown on the alarm popup.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.19.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-19-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a1fb965d-cd63-4e72-9a73-535da485fffa</guid>
        <pubDate>2022-07-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.19.0</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Identification of controllers in Pairing page.
<ul>
<li>Added the ability to send the "Identify" command from the "Pair" page.</li>
<li>This command creates a blinking pattern of the power LED of the PSM3.1 card.</li>
<li>This allows users working in an environment with multiple controllers to easily confirm the controller they wish to pair the display with.</li>
</ul>
</li>
<li>Support for CODESYS custom info pop-up and status text.
<ul>
<li>This allows CODESYS designers to provide better user experience by delivering messaging and status information of the CODESYS application.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Synchroscope page label
<ul>
<li>Added a label to identify the breaker that is being synchronised.</li>
<li>This improves the recognition of the controller being synchronised.</li>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 DU 300 ver 1.x.x &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-du-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">24de3727-0f7c-405f-a0c4-a9ccb4a3cb47</guid>
        <pubDate>2022-07-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 DU 300 ver 1.x.x</category>
        <category domain="version">1.0.20.0</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPU 300 ver. 1.x.x. &#x2013; v1.0.1.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-1-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">94e9f160-d323-47d5-8e60-aa943dca26b9</guid>
        <pubDate>2019-11-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPU 300 ver. 1.x.x.</category>
        <category domain="version">1.0.1.1</category>
          <category domain="product">GPU 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPU 300</li>
<li>Bundled with DU 300 SW version 1.0.4.0</li>
</ul>
<p><strong>​</strong></p>
<h3>Corrections:</h3>
<ul>
<li>BSP version 3.0.1.0 supported.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPU 300 ver. 1.x.x. &#x2013; v1.0.1.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-1-1-updated-du300/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">222a75e9-dfa9-43f1-8977-b34a27d3bd71</guid>
        <pubDate>2019-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPU 300 ver. 1.x.x.</category>
        <category domain="version">1.0.1.1</category>
          <category domain="release-status">current</category>
          <category domain="product">GPU 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPU 300</li>
<li>Bundled with DU 300 SW version 1.0.10.0</li>
</ul>
<h3>GPU 300</h3>
<h3>Corrections:</h3>
<ul>
<li>BSP version 3.0.1.0 supported.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Support for multiple menu levels.</li>
<li>Display shows a pop-up window for the user before going into service mode.</li>
<li>Informs the user about development of the software.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Support for PlantSupervision ver 1.0.5.0.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>IOM3.4: DO's are not shown on display and in PICUS.</li>
<li>Display is not loading min. and max. from parameters when they are changed.</li>
<li>Power derate temperature is not shown on DU until power cycle.</li>
<li>When changing type, DU sometimes freezes until it restarts.</li>
<li>DU300 reboot in view designer.</li>
<li>Not able to close alarm pop-up.</li>
<li>Alarm "trigger value" is not updated if the alarm is already in the alarm list.</li>
<li>DU300 does not check versions for individual REST resources.</li>
<li>View designer cannot add counters to counters template.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">861d50ed-40e1-4818-92c9-6802933f7a8e</guid>
        <pubDate>2021-01-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.13.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Flexible application setup:
<ul>
<li>It is now possible to customise the application drawings to provide a customisable interface.</li>
<li>The design of applications with multiple ring connections is now possible.</li>
</ul>
</li>
<li>Support of electronic engines protocols (EIC):<br />
<ul>
<li>Supports the Generic J1939 protocol for reading.</li>
<li>J1939 values, alarms and historical events are now available.</li>
</ul>
</li>
<li>Backup and restore:<br />
<ul>
<li>Partial Backup and restore: It is now possible to select which configurations to backup or restore.</li>
<li>Improvements include preparation of restore report, and changing controller type by restoring.</li>
</ul>
</li>
</ul>
<h3>Changes :</h3>
<ul>
<li>Update rate of live data in the display and in PICUS is increased.</li>
<li>Passwords can now have any number of characters between 1 and 32.</li>
<li>New default password is "0" for all users.</li>
<li>Offline file is removed from the Connect screen.</li>
</ul>
<h3>Bug fixes :</h3>
<ul>
<li>Corrections in CustomLogic while giving descriptions of the same variables/functions.</li>
<li>Corrections in NTP by saving only time when only time is changed.</li>
<li>Alarm action button Remove from service was not enabled when it should be.</li>
<li>Corrections of messages in firmware update.</li>
<li>Several usability and stability corrections.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a4ff1e70-2660-4638-a73f-a20c01ff3b0b</guid>
        <pubDate>2021-10-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.16.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New Features :</h3>
<ul>
<li>Software versions page: </li>
<li>New user interface with ability to filter and select controllers.</li>
<li>Adds the ability to read and compare software versions from multiple controllers.</li>
<li>Tags:
<ul>
<li>Adds the ability to read and display tags in Parameters, Alarms, Logs and Report.</li>
<li>All ANSI-coded parameters have now been tagged with their respective code.</li>
</ul>
</li>
</ul>
<h3>Improvements:</h3>
<ul>
<li>Custom Logic improvements.</li>
<li>It is now possible to visualize the full texts in Custom Logic.</li>
<li>Texts remain truncated when elements are placed next to each other.</li>
</ul>
<h3>Bug fixes:</h3>
<ul>
<li>Solves an issue where PICUS would update the DU300 BSP even when it was not required.</li>
<li>Solves an issue where the commissioning report would not be produced.</li>
<li>Solves an issue where PICUS would not open the Analog Inputs pane in I/O status page.</li>
<li>Solves an issue where PICUS would not show any Live Data when some regional settings were selected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a8bc926d-2fef-423e-9ccd-c82da1388719</guid>
        <pubDate>2021-05-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.14.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>I/O Status<br />
<ul>
<li>See the status of digital and analogue inputs and outputs.</li>
<li>See J1939 measurements by selecting J1939 as a filter.</li>
<li>For advanced analysis: Show/hide the physical (unscaled) values of analogue inputs and outputs.</li>
<li>System designer: Restrict access to this page using Permissions.</li>
</ul>
</li>
<li>Trending<br />
<ul>
<li>Record and see data collected over a period of time.</li>
<li>Trend up to 4 values per graph and up to 6 graphs per trending session.</li>
<li>Export trends to a .CSV file.</li>
<li>Known issues:<br />
<ul>
<li>For faster update rates, the performance of the PC and PICUS may deteriorate.</li>
<li>For update rates below 500ms, the graphical representation is refreshed at a maximum refresh rate of 500 ms.</li>
<li>It is not possible to trend simultaneously from multiple instances of PICUS.</li>
</ul>
</li>
</ul>
</li>
<li>Additional content added to the Modbus table.<br />
<ul>
<li>Alarm Inhibited flag is now available.</li>
<li>Command to "Remove Alarm from Service" is now available.</li>
<li>CustomLogic and CODESYS inputs and outputs are now available on Modbus.</li>
<li>Status of all inputs and outputs are now available on Modbus.</li>
</ul>
</li>
</ul>
<h3>Bug fixes:</h3>
<ul>
<li>Stability and usability improvements</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.13.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c7710f25-281d-4997-8678-d4d62f1244ff</guid>
        <pubDate>2021-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.13.2</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Changes :</h3>
<ul>
<li>Stability and usability improvements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">992f349f-744a-4a7d-bae8-6f8ef6b7ed20</guid>
        <pubDate>2020-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.12.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support of IOM3.2 and IOM3.3.</li>
</ul>
<h3>Bug fixes :</h3>
<ul>
<li>Different checkbox in the above/below range in PICUS.</li>
<li>Different font in the minimized/maximised window in PICUS.</li>
<li>Report was not showing the selected Compensation information.</li>
<li>Description in CustomLogic on internal variables was not updated.</li>
<li>Edit of BITMAP address in the Modbus configuration was not working.</li>
<li>Issue with saving the Modbus protocol made in PICUS.</li>
<li>PICUS was not always showing Path in the Modbus list.</li>
<li>PICUS was not getting values in the Modbus configurator.</li>
<li>PICUS would freeze after the network was lost during backup.</li>
<li>It was not possible to set precision for custom scales for analogue Input and analogue output in PICUS.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.12.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-12-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ecb969e9-7bc5-44fd-b88c-7e17229b3b20</guid>
        <pubDate>2020-08-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.12.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Bug fixes :</h3>
<ul>
<li>Various usability improvements</li>
<li>Fixed issue with conversion of US units</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3579a220-8106-4013-86c2-f10f1834f15c</guid>
        <pubDate>2021-07-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.15.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New Features :</h3>
<ul>
<li>Counters: Read, Preset and Reset counters.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Improvement and bug fixes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6dee7e0a-7152-42dc-b841-22abf2d72cbe</guid>
        <pubDate>2021-10-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.16.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Bug fixes:</h3>
<ul>
<li>Fixes an issue where application configuration and IO status would not open while working on VPN, or opening a file while disconnected from the controller.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">74403488-2e29-42a2-9db6-e0dc6f26f4a5</guid>
        <pubDate>2022-02-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.17.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<p>• Log page search and filtering<br />• Added the ability to search the contents of the log table.<br />• Added the ability to use filters in the columns of the log table.<br />• Added the ability to reset all filters and sorts with a single user action.<br /><br />• Parameter page<br />• Added the ability to search the parameters page for parameter names and tags.<br />• Added a change indicator to the parameters and the navigation to easily identify which parametes have been changed.<br />• Added a change counter with a link to the log of changes in the parameters.<br />• Added the ability to undo changes in the window containing the log of parameter changes.<br />• Added the ability to write the modified parameters only.<br />• Added the ability to reset the parameter to the default value.<br />• Added the ability to reset the parameter to the value written on the controller.<br />• Added the ability to expand/collapse all the parameter channels.<br /><br /></p>
<h3>Improvements:</h3>
<p>• Improved the look and feel of the Log page user interface.<br />• Improved the look and feel of the Parameter page user interface.<br />• Parameter page: It is now possible to add more than four inhibits to protection parameters.</p>
<h3>Bug fixes:</h3>
<p>• The log page was completely rebuilt and all previously reported bugs have been addressed.<br />• The parameter page was completely rebuilt and all previously reported bugs have been addressed.<br />• Solved an issue in the I/O Emulation modal where the (X) button would not close the window.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.17.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-17-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a1b4621b-8e1d-4a7a-b0d4-3ba4c64e0cfe</guid>
        <pubDate>2022-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.17.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue that prevented the parameters to be displayed when opening a configuration file.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d0e1c539-7919-46a5-a031-eeb169f874bb</guid>
        <pubDate>2022-04-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.18.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Configuration of breakers with an under-voltage coil.</li>
<li>Provides the ability to configure a circuit breaker with an under-voltage coil for an improved response of the power management system.</li>
<li>Parameter page<br />
<ul>
<li>Added the ability to see all the parameters under a parent node allowing the user to configure the controller with fewer navigation actions.</li>
<li>Added a page option to expand the Advanced panel of all parameter groups, allowing advanced users to have a full view of all parameters.</li>
</ul>
</li>
</ul>
<h3>Improvements:</h3>
<ul>
<li>Improved the look and feel of the Communication page user interface.</li>
<li>Improved the look and feel of the Regulator Status page user interface.</li>
<li>Improved the look and feel of the Time Settings page user interface.</li>
<li>Parameter page: The Advanced section of the parameters is now collapsed to simplify the configuration for entry-level users.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>The Communication page was completely rebuilt and all previously reported bugs have been addressed.</li>
<li>The Time Settings page was completely rebuilt and all previously reported bugs have been addressed.</li>
<li>Solved an issue that occasionally generated an Access Violation Error.</li>
<li>Solved an issue where the BSP would not be updated.</li>
<li>Solved an issue where it was not possible to open parameters in a backup file located on a network drive.</li>
<li>Other stability and performance improvements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.19.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-19-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4f28ad06-c659-4c11-8880-20686935d3ca</guid>
        <pubDate>2022-07-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.19.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Alarms page<br />- Added the ability to search the contents of the alarms table<br />- Added the ability to use filters in the columns of the alarms page<br />- Added the ability to reset all filters and sorts with a single user action.<br />- Added the ability to act on a multiple selection of alarms.</li>
</ul>
<h3>Improvements:</h3>
<ul>
<li>Improved the look and feel of the Alarms page user interface.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>The alarms page was completely rebuilt and all previously reported bugs have been addressed.</li>
<li>Solved an issue where the disconnect button did not respect the selection of controllers to disconnect.</li>
<li>Solved an issue where the tool would not show Analogue Output values when the regional settings were set to USA.</li>
<li>Solved an issue where minimum and maximum limits were not working for the configuration of Analogue Outputs.</li>
<li>Solved an issue where the Parameters page would always refresh on external changes.</li>
<li>Solved an issue where the Identify button would not work correctly.</li>
<li>Solved performance and stability issues on firmware update functions.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.19.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-19-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">78ad9877-fbde-4f87-a353-aa1430aa6fda</guid>
        <pubDate>2022-09-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.19.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Improvements:</h3>
<ul>
<li>Increased the size of the backup pop-up window, to allow even more controllers to be visible simultaneously.</li>
<li>Disabled the Dev Tools when right-clicking on PICUS.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue that caused the alarms table not to fill the full width when the window is maximised.</li>
<li>Fixed an issue that prevented decimal numbers being used in the Y-scale of trending charts.</li>
<li>Fixed an issue where the alarms would not sort by date.</li>
<li>Fixed a minor issue where Fieldbus supervision would show 5 slots in a 4-slot rack.</li>
<li>Fixed an issue that caused the connected hosts not to be stored in the list of recent hosts.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.19.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-19-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">adaa9cd2-4b04-488b-83d9-f3efae7ddd4d</guid>
        <pubDate>2022-12-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.19.2</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Improvements:</h3>
<ul>
<li>Millisecond resolution is re-introduced in Log and Alarm pages.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixes an issue that prevent some pages from loading correctly.</li>
<li>Fixes an issue that caused the ID and name of the controller to be incorrect when not connected to a controller.</li>
<li>Fixes an issue where the single-line (application) drawing <br />printed to the report was incorrect.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">20bc1469-737b-4dcb-906c-1582f84c5146</guid>
        <pubDate>2023-03-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.20.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for IO controller option.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Added Mains controller with mains breaker and tie breaker to application drawing.</li>
<li>Added new rules for bus tie breaker handling for increased support of legacy power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Corrected parameters related to stabilised differential protection.</li>
<li>Corrected an issue that did not allow the user to assign more than 3 HC to each controller.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.20.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">af06b7e7-7ef2-4807-9e52-83357f08a3a2</guid>
        <pubDate>2023-10-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.20.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<p>• Corrected issue where the IO Status page would not update correctly on BTB or Mains controllers.<br />• Corrected issue where the controller would be locked in switchboard control when equipped with a GAM3.2 module.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-1-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7eb2f77e-1494-4eed-83f8-3f4a59d23780</guid>
        <pubDate>2024-02-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.21.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New:</h3>
<p>- Support for iE 250 and iE 350 controllers<br />- Application page<br />Introducing the ability to design multiple application drawings for added flexibility of the controlled assets.<br />- Display designer<br />With the all new dashboard designer for iE 250 and iE 350, it is now possible to customise the user interface to the specific needs of a project.<br />Unlock the full power of the iE 250 and iE 350 touchscreen by customising the header, footer buttons and views with an easy and intuitive tool.<br />The dashboard designer delivers a variety of widgets that allows creation of dynamic and informative user interfaces.<br />DEIF's iconic application mimic can be selected on individual views to deliver consistent information of the application at a glance.</p>
<p>- I/O configuration page<br />We have made changes to the way selected products are configured in order to deliver a more consistent experience between configuration tool and controller, and across different features.</p>
<p>- Users and Roles management have been redesigned to secure compliance with IEC62443 standard and other cybersecurity regulations (only iE 250 and iE 350)</p>
<p>- Parameters page<br />It is now possible to set Severity on alarm configuration allowing to create a more intuitive understanding of the asset status by presenting a colour coded alarm to the operator, based on the alarm's Severity (only iE 250 and iE 350).</p>
<p> </p>
<h3>Changes:</h3>
<p>- New navigation menu for seamless transition between configuration and visualisation pages.</p>
<p> </p>
<h3>Corrections:</h3>
<p>A few bugs have been harmed during the making of this release.</p>
<p> </p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.22.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-22-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c0ab6498-7a56-4dfb-aa22-0623e47fe322</guid>
        <pubDate>2024-07-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.22.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<p>- Network port configuration for iE x50 ring networks (MRP) - it is now possible to configure ring networks on the iE 250 and iE 350 controllers using MRP ring technology.</p>
<p>- Digital I/O Safe state - it is now possible to enable, disable and set wire break detection on the digital I/O channels of the MIO2.1.</p>
<p>&nbsp;</p>
<h3>Changes</h3>
<p>- PICUS now enforces password strength protection in accordance with CR1.7 of the IEC62443 standard for cyber security.</p>
<p>- PICUS now enforces a session lock after 24 hours in accordance with CR2.5 of the IEC62443 standard for cyber security.</p>
<p>&nbsp;</p>
<h3>Corrections</h3>
<p>- Fixed an issue that prevented PICUS from configuring GPC 300, PPU 300, and PPM 300 products.<br>- Fixed an issue that prevented custom names for I/Os from being displayed in CODESYS.</p>
<p>&nbsp;</p>
<p>Other stability improvements and minor visual corrections. A few bugs have been harmed during the making of this release.</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.23.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-23-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3ce3b936-d798-43bb-8e96-03231fa2aad9</guid>
        <pubDate>2024-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.23.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Broadcast and activate application from SLAD page.</li>
</ul>
<p>&nbsp;</p>
<h3>Corrections</h3>
<ul>
<li>Fixed issue with login to ML 300 controllers.</li>
<li>Fixed issue where external BTB was not possible.</li>
<li>Fixed issue where Y-axis on AO jumped to high value when written with negative value.</li>
<li>Resolved issue where a user could not be created due to default inactivity timer.</li>
<li>Resolved issue where the user was unable to read the full text in the side menu.</li>
<li>Fixed issue where a Modbus interface could not be set up on a small screen.</li>
<li>Resolved issue where Input Field in Card Configuration was not selected when clicking on line.</li>
<li>Improved error message for IO assignment.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.23.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-23-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c3b2e04a-78dc-4f8a-be81-9f46013a4376</guid>
        <pubDate>2024-12-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.23.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where custom logic I/Os did not change name according to their configured terminal.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.24.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-24-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b08eada9-c6e7-4efa-b8db-10c09d41f237</guid>
        <pubDate>2025-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.24.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Plug-in module support: Added support for iE 250 - PIM 2.x.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Notifications: Enhanced message text clarity for better user understanding.</li>
<li>Alarm List: Improved default view.</li>
<li>User Management: Editing mode remains active after duplicating or deleting a user.</li>
<li>Users can now remove roles without encountering errors.</li>
<li>Deleting user functions as expected.</li>
<li>Application supervision: iE 250 card selection now accurately displays the number of connected controllers.</li>
<li>Support for PIM 2.x module.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.24.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-24-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">24cb60b3-4fb1-4b2b-b309-c4bf40174adf</guid>
        <pubDate>2025-04-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.24.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issues preventing alarms being shelved.</li>
<li>Fixed an issue preventing PICUS from closing correctly.</li>
<li>Fixed issues in user management and handling caused by cybersecurity functionality.</li>
<li>Fixed an issue preventing the use of multiple instances of PICUS.</li>
<li>Fixed an issue preventing the use of Security Settings as intended.</li>
<li>Fixed other minor user experience and functionality issues.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.24.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-24-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ad0d9981-f631-4ded-b7db-c6273a08a00e</guid>
        <pubDate>2025-07-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.24.2</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Resolved an issue in Trending where the Delete button on the chart did not function as intended.</li>
<li>Fixed a problem in I/O where it was not possible to assign custom alarms to an output.</li>
<li>Addressed an analogue output (AO) configuration issue on iE 350 and iE 250 devices.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.25.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bbbc721c-7adb-4974-a3c6-4c7a9203b72f</guid>
        <pubDate>2025-08-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.25.0</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Improvements</h3>
<ul>
<li>Improved grid code and capability curve handling, including updated tables</li>
<li>General improvements to the user interface</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Corrected ramping curve points and axis units display</li>
<li>Resolved support for negative values on analogue outputs.</li>
<li>Fixed an issue with input handling for stabilised current protection</li>
<li>Resolved an issue with missing chapter in CustomLogic report</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.25.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c1706270-bc31-4bbc-b638-9dc7e21aa751</guid>
        <pubDate>2025-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.25.1</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Fixed issues</h3>
<ul>
<li>Alarm page did not update correctly after latch reset.</li>
<li>User password confirmation field triggered an error before the initial entry was completed.</li>
<li>Trending charts did not display data correctly.</li>
<li>Adjusting the first two default points on an analogue custom curve was not detected as a change.</li>
<li>Trending: editing and saving chart configurations did not function as expected.</li>
<li>Display Designer monitoring for kW and cos phi setpoints defect corrected.</li>
<li>Chinese language characters now display correctly.</li>
<li>View design backup process now functions reliably.</li>
<li>Authorisation framework for security and role handling improved.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.25.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7dbb50e1-cc3e-4c5c-ba5f-a66f600b299c</guid>
        <pubDate>2025-12-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.25.2</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<p>Changes</p>
<ul>
<li>Users are now allowed to edit the footer button text.</li>
</ul>
<p>Fixes</p>
<ul>
<li>Fixed an issue that prevented users from restoring a backup on a controller.</li>
<li>Fixed an issue that prevented users from configuring the controller and displayed a “Cannot fetch data” error.</li>
<li>Fixed an issue where the indicator component (in View Editor) would not activate with the Alarm Active Status flags.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.25.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">79811a29-7d98-40b9-be4a-0506d20802a6</guid>
        <pubDate>2026-03-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.25.3</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>CAN bus values can be used with (°F, psi &amp; gal/h) in Dashboard Editor.</li>
</ul>
<h3>Correction</h3>
<ul>
<li>Fixed stability issues related to the backup/restore functionality.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>PICUS ver. 1.x.x. &#x2013; v1.0.26.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-picus-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9dc0245e-395d-42ea-b949-c55945ef088f</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">PICUS ver. 1.x.x.</category>
        <category domain="version">1.0.26.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC 300</category>
          <category domain="product">GPU 300</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">PICUS</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Advanced curve configuration:<br>- Capability curves configurable via table or interactive graph.<br>- Improved Fault Ride Through (FRT) and Rate of Change of Frequency (RoCoF) visualisation.<br>- Support for multiple data sets, activation and recovery markers, alarms, and selectable units.</li>
<li>Support for future product capabilities:<br>- Component-based PICUS applications supporting both single-asset and multi-asset plants.<br>- Multi-asset configuration enabling assignment of controller IDs, updating of properties, and management of assets individually or in groups.<br>- Flexible application configuration with support for endpoints, separators, component IDs, and automatic adaptation to different controller REST versions.<br>- Visual plant design enhancements with support for additional assets, including PV panels, fuel cells, thrusters, and AC/DC loads.<br>- Template management enabling users to create, edit, import, export, and delete custom templates.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issues affecting the saving, loading, and deployment of PICUS configurations.<br>Fixed user interface stability issues, including locked screens, incorrect unsaved-change prompts, and page-loading failures.</li>
<li>Fixed issues in graph rendering and interaction, including point handling, scaling, translation, and visual accuracy.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">03e77b24-5e7a-4d80-95f0-c118859c706f</guid>
        <pubDate>2021-11-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.16.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.16.0</li>
</ul>
<h3>PPM 300</h3>
<h3>Corrections:</h3>
<ul>
<li>Fixes an issue where Heavy Consumers with delayed priority shift would be handled incorrectly.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Support for Tags:<br />
<ul>
<li>New menu for options to display the tags set in parameters.</li>
<li>Options for tag visualisation include: Alarm pop-up, alarm list, logs page and parameter page.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Update to languages</li>
<li>Connection improvements</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solves an issue where the display could enter a manual loop after returning from synchroscope.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">484d1958-8ee1-42c5-bc71-e74f85fba632</guid>
        <pubDate>2021-05-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.14.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPM 300</h3>
<h3>New feature:</h3>
<ul>
<li>All I/O cards and CAN bus values can now be mapped in Modbus.</li>
<li>ECU: Communication failure is added. When communication is expected, but not present, an alarm is triggered. </li>
<li>Live data: J1939 protocol is now available for engine communication.  </li>
<li>Inhibit for idle run is added.</li>
<li>It is possible to skip Idle Run Stop by requesting "Stop" again.</li>
<li>Idle run stop is added.</li>
<li>Inhibit for idle run is added.</li>
<li>It is possible to skip Idle Run Start by requesting "Start" again.</li>
<li>Idle run start is added.</li>
<li>CustomLogic inputs and outputs (digital and analogue) are available in Modbus.</li>
<li>Inhibit status for alarms is available in Modbus.</li>
<li>Alarm property "Remove from service" is now available in Modbus.</li>
<li>The external regulation value can now be read in the regulator status tool.</li>
<li>State of the manual regulation input can now be read in the regulator status tool.</li>
<li>The source of regulation can now be read in regulator status tool.</li>
<li>Engine ECU: Process data alarms are added, and it is now possible to get application alarms from either the ECU or an analogue input.</li>
<li>Engine ECU data has been mapped to communication (incl. standard Modbus) and is configurable in flexible Modbus.</li>
<li>New ECU: Auto discover is added and can be activated from either CustomLogic, CODESYS, Modbus, or Commands.</li>
<li>Live data groupings are arranged in groups according to the engine sub systems.</li>
<li>Live data screen view: Now you can see measurements from different sources based on the priority Analogue/IO over ECU.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>The Modbus connections for Idle Time Expired are changed from 100 seconds to 10 seconds.</li>
<li>The default AC setup values are changed.</li>
<li>"AVR trip" location in CustomLogic for Hybrid is cleaned up.</li>
<li>The text for Hybrid is corrected.</li>
<li>Spelling error: "Deloading" is changed to "De-loading".</li>
<li>Phase sequence error text is corrected for Hybrid.</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>Fixed that Modbus crashed when trying to connect many times, and not getting a new connection.</li>
<li>Fixed that Ship to ship did not work when the busbar load was greater than the SC nominal power.</li>
<li>Fixed that the Limit Exceeded parameter for Q asymmetric load share did not function.</li>
<li>Fixed an issue where the set point for fixed reactive power regulator was not corrected when running in parallel with SC or SG in base load.</li>
<li>Fixed an issue with continuous breaker with mismatch between closing failure and output states.</li>
<li>Fixed an issue with asymmetric, if all load sharing controllers were in asymmetric load share and lowest priority controller was not connected.</li>
<li>Breaker operation counter increment is now working.</li>
<li>Trip counter is now incremented for Hybrid when a trip occurs.</li>
<li>Shore and shaft supervision status is fixed.</li>
<li>Fixed an issue where Manual GOV adjustment in emulation could affect the voltage.</li>
<li>Fixed an issue where EDG sometimes would handle blackouts unexpected while the tie breaker synchronize and busbar went black.</li>
<li>Fixed an issue where default max value for EIM3.1 resistance analogue input sensor was to high.</li>
<li>Fixed an issue where primary breaker trip did not trigger NEL trip (if enabled).</li>
<li>Default settings for blackout detection mismatch alarm are changed to fix an issue where the controller would start the engine and not close the breaker.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<p>Changes:</p>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.14.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">81ee7aee-601f-487d-a8f3-3996e67d5ba7</guid>
        <pubDate>2021-06-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.14.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPM 300</h3>
<h3>Corrections:</h3>
<ul>
<li>Allows IOM3.4 Firmware revision 1.0.0.2.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.13.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">843d7c76-e6fb-4c05-98bb-17ce13457f5b</guid>
        <pubDate>2021-04-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.13.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPM 300</h3>
<h3>Correction:</h3>
<ul>
<li>Fixed issue where controller restarts if writing to oil pressure on Modbus</li>
<li>Included bugfix on EIM3.1</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<p>Changes:</p>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b0412219-c4f3-4f4f-8a61-c909dc94fa9f</guid>
        <pubDate>2019-12-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.10.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.11.0</li>
</ul>
<h3>PPM 300</h3>
<h3>New feature:</h3>
<ul>
<li>Alarms can now be tested individually.</li>
<li>Support for ACM3.2 card.</li>
<li>Breaker, tripping and opening can now be assigned to individual outputs.</li>
<li>AVR can now be tripped by specific alarm actions.</li>
<li>Single line support for 32 controllers.</li>
<li>Flexible Modbus: User configuration of register mapping and support for additional servers.</li>
<li>Alarm details now include number of times the alarm was triggered.</li>
<li>Nominal settings: 4 sets are now available.</li>
<li>User interfaces: Different languages are now supported.</li>
<li>MODBUS: Registers for Date/Time are now available.</li>
<li>Alive/watchdog functionallity is now available.</li>
<li>I/O Extension units: This feature allows expansion of an ML 300 system with additional de-centralised racks containing the desired I/O cards.</li>
<li>Firmware update: Replacement cards can be updated without using the utility software.</li>
<li>Firmware upgrade: In case of a controller not being ready for update, detailed information about the cause is now shown.</li>
<li>Smarter handling of SG's contributions to the PMS system.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Fixed texts relating to GAM3.2 I/O-configuration.</li>
<li>Aligned order of GOV and AVR configuration parameters.</li>
<li>Show "Disclaimer" when using preliminary software.</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>Fixed that DG would continue de-loading an SG beyond its nominal power.</li>
<li>Fixed that "Base load" on an SG could be disabled, even when this would result in overloading the other controllers in the system.</li>
<li>Fixed that names used for I/O and alarms on Heavy Consumers would not uniquely identify each Heavy Consumer.</li>
<li>Fixed that alarms for "Power import" were missing on BTB.</li>
<li>Fixed that some labels in the PICUS menu hierarchy would be truncated.</li>
<li>Fixed that BTB blackout close would display the wrong pop-up text ("Busbar A voltage/frequency not OK").</li>
<li>Fixed that the Active/Reactive power differential counter pulse functionallity did not activate when importing power, only when exporting.</li>
<li>Fixed that in "Running hour counters" were missing in CustomLogic.</li>
<li>Fixed that status for "Controller Mode" (on Modbus etc.) could not hold values for all available modes, resulting in values not reflecting the actual state.</li>
<li>Fixed that DG's did not abort the de-load procedure, when this would result in an overload situation, resulting in a blackout.</li>
<li>Fixed that certain Modbus addresses could not be used as commands.</li>
<li>Fixed that the regulation mode "Asymmetric Q load-share" did not have a unique status text.</li>
<li>Fixed that alarms related to Generator protections would remain triggered if "Delay" was set to 0.0 seconds.</li>
<li>Fixed that "Engine ready delay" would be ignored on SG's.</li>
<li>Fixed that de-loading of multiple SC's would result in a "De-load error".</li>
<li>Fixed that BTB could close on busbar, even if "Common blackout" was not detected.</li>
<li>Fixed that on the display the "Counters" screen would show irrelevant entries.</li>
<li>Fixed that status for "Voltage and frequency OK" did not respect the "Delay" parameter setting.</li>
<li>Fixed that "Regulator ramp up/down" did not work when operating in load share mode.</li>
<li>Fixed that the alarm "Earth inverse time over-current" did not trip according to the settings.</li>
<li>Fixed that CustomLogic could stop working if the controller was power cycled immediately after "Write" of a new CustomLogic configuration.</li>
<li>Fixed false detection of Volt/Hz due to missing data from ACM card.</li>
<li>Fixed that inhibit functionallity was not available for NEL groups.</li>
<li>Fixed that Regulator status screen could show wrong values.</li>
<li>Fixed that if a blackout was detected (real or loss of measurements) during the synchronisation part of a close sequence, the sequence would be cancelled.</li>
<li>Fixed a potential issue with inhibits not being updated.</li>
<li>Fixed that "Engine start-and-close" in combination with "Blackout close" would close the breaker before the engine was running.</li>
<li>Fixed that inputs type "DI" in "I/O Configuration", would be shown as "Undefined" when used for CustomLogic.</li>
<li>Fixed that "Derate" functionallity did not influence "Power Available" calculation correctly, thus affecting load share.</li>
<li>Fixed that DG could stall in de-load sequence.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Extended alarm information.</li>
<li>Support of ACM3.2 V.1.0.0.0.</li>
<li>Support of Trip breaker outputs.</li>
<li>Support of /IO extension unit.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Version page layout.</li>
<li>Backup and restore information.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Text bug in live views.</li>
<li>DU shows random info message.</li>
<li>Display showing wrong version number.</li>
<li>ApplState not updating text.</li>
<li>Backup from the display shows undefined text in information window.</li>
<li>Missing text for View design.</li>
<li>Restore info page: Not all cards is shown.</li>
<li>Display does not update alarm and event texts, when the custom text is changed on external breaker.</li>
<li>Backup status should handle error status.</li>
<li>Possible to enter alarm sub-menus with an empty alarms list.</li>
<li>Parameter settings are shown on the display, when setting up digital outputs.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e0bbf3e8-29ad-4ace-abdd-26f772fd440c</guid>
        <pubDate>2021-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.13.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.14.0</li>
</ul>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>AC measurement averaging:<br />
<ul>
<li>It is now possible to use averaging filters (200ms and 800ms) to reduce the value fluctuations from the high performance of the measurement cards.</li>
<li>The averaging filter can be applied selectively to different types of measurements.</li>
<li>AC measurement averaging affects data displayed by DU 300, PICUS, trending, CustomLogic, CODESYS, and Modbus.</li>
<li>AC measurement averaging does not affect protections and regulation values.</li>
</ul>
</li>
<li>EIM3.1 Safety shutdown function:<br />
<ul>
<li>EIM3.1 can now be used as a safety shutdown module.</li>
<li>EIM 3.1 will be able to run the engine in stand-alone mode should it no longer be able to communicate with the main processor card (PCM).</li>
</ul>
</li>
<li>Hybrid controller type added.</li>
<li>Support of electronic engines protocols (EIC):<br />
<ul>
<li>Supports the Generic J1939 protocol for reading.</li>
<li>J1939 values, alarms and historical events are now available.</li>
<li>New engine measurement inputs + alarms added for: Oil pressure, Oil temperature, Coolant temperature, and Coolant level.</li>
</ul>
</li>
<li>Asymmetric load sharing:<br />
<ul>
<li>New asymmetric load sharing optional mode allows asymmetric gensets to automatically re-calculate their set points when the maximum asymmetry is exceeded.</li>
<li>There is now an option to start the next genset when the asymmetric load sharing limit is exceeded.</li>
</ul>
</li>
<li>Flexible application drawing:<br />
<ul>
<li>It is now possible to customise the application drawings to provide a customisable interface.</li>
<li>The design of applications with multiple ring connections is now supported.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Update rate of live data in diplay and PICUS is increased.<br />
<ul>
<li>Changed calculation of "Section | PMS P used [%]" and "Section | Conn. P used [%]" , to use derate nominal instead of nominal.</li>
<li>Changed popup text when pressing close breaker, and engine is not running from: "Engine not ready" to "Engine not running".</li>
<li>Changed popup text when start engine and close generator breaker is activated to "GB close blocked".</li>
<li>Changed: Possible to change time and date individually from PICUS.</li>
</ul>
</li>
<li>The password length can now be 1 to 32 characters.<br />
<ul>
<li>The new default password is "0" for all users.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Alarm timer expired flag data added to Modbus.</li>
<li>CustomLogic IO added to Flexible Modbus.</li>
<li>Fixed issue where DG continues PMS operation if the controller is changed to semi.</li>
<li>Fixed issue where NELs trip if breaker is opened.</li>
<li>Fixed issue where a redundant blackout timer blocked another breaker from closing.</li>
<li>Fixed issue where changing of counters from Modbus not was saved if there was a controller power cycle shortly after.</li>
<li>Fixed issue where custom alarms do not get units in the alarm and event logs.</li>
<li>Fixed issue where engine shutdowns under cooldown are affected by the non-connected stop timer.</li>
<li>Fixed issue where external shore connection(s) could prevent a bus tie breaker from closing.</li>
<li>Fixed issue where external shore connection(s) could prevent a bus tie breaker from opening.</li>
<li>Fixed issue where hidden Modbus addresses was accessible.</li>
<li>Fixed issue where regulator did not reset on external stop .</li>
<li>Fixed issue where extended stop delay was skipped on external stop.</li>
<li>Fixed issue where trip output does not activate when "breaker position failure" is active.</li>
<li>Fixed issue with rounding problems on decimal values in Modbus data.</li>
<li>Fixed rare issue where backup file was corrupted.</li>
<li>Fixed issue where the AMC3.2 protections did not work on the Shaft generator.</li>
<li>Fixed issue where the breaker open signal could be sent because of missing inhibit info on ACM3.2.</li>
<li>Fixed issue where deactivate secured mode did not work in a plant with an open BTB.</li>
<li>Fixed issue where different controller software will run in the same system.</li>
<li>When changing single line diagram - cleaning up alarms related to redundant breaker.</li>
<li>When ramping, the status text is now shown on the PPM.</li>
<li>Fixed issue where breaker opened before the breaker open point is reached.</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Custom alarm action suppression: It is now possible to enable alarm suppression for custom alarms from the display.</li>
<li>Fast data interface: Faster update rate of gauges, counters, status texts, and live data views.</li>
<li>Engine communication:
<ul>
<li>J1939 alarms and historical events.</li>
<li>Fieldbus, configuration, supervision and CANbus error handling.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed translation of texts in the View designer.</li>
<li>Fixed translation of message box popup breadcrumb.</li>
<li>Fixed DU300 live data subheader text cutting lower case p, g, j, q, y letters.</li>
<li>Fixed DU300 showing negative ampere.</li>
<li>Fixed conversion between C and F not having effect on scaling (View design).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6dd7c4c5-71cf-41d4-991c-cef397ef1aff</guid>
        <pubDate>2020-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.12.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.13.0</li>
</ul>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>Support for the new IOM3.2 and IOM3.3 cards.</li>
<li>Derate of nominal power is now possible with an analogue input.</li>
<li>Digital fast load reduction output is available with the possibility to activate a relay based on low available power and/or low frequency on the busbar.&nbsp; &nbsp;&nbsp;</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Ethernet port settings: "Display" is no longer a selectable option.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue where PICUS supervision would update if the regulator type was changed.</li>
<li>Fixed an issue where PICUS was unable to show I/O configuration from a backup file in controllers with multiple EIM3.1 cards installed.</li>
<li>Fixed an issue where manual regulator ramping was very slow when using an analogue output.</li>
<li>Fixed an issue where regulator output selection failure alarm was triggered during power up of the controller.</li>
<li>Fiexed an issue where above and below range alarms on analogue inputs were not working.</li>
<li>Fixed an issue where EIM3.1 relay 4 wire breaker supervision was not working.</li>
<li>Fixed an issue where IOM3.4 custom texts could be mixed up if more than one card were used. This fix result in a break of backward compatibility, if custom text has been used on IOM3.4 cards.</li>
<li>Fixed an issue where adding a previously used extension rack to a new system could cause the controller to restart.</li>
<li>&nbsp; &nbsp; 9 - Fixed an issue where connection to an extension unit could cause the controller to restart in a system with more than two extension units.<br>&nbsp; &nbsp;</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Support of IOM3.2 and IOM3.3.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.12.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-12-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">29be2a1b-04bd-4f42-a36a-f0834f34b240</guid>
        <pubDate>2020-09-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.12.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.13.1</li>
</ul>
<h3>PPM 300</h3>
<h3>Correction:</h3>
<ul>
<li>Fixed an issue where GAM3.2 stand-alone mode did not work with the PWM output.   </li>
</ul>
<h3>DU 300:<br /><br />Changes:</h3>
<ul>
<li>Change default DU300 font to Noto sans</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Not converting set point and hysteresis to F on custom alarms</li>
<li>Memory leak during PPU long term test</li>
</ul>
<div></div>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.14.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c74dcd2c-9543-4d1a-ad84-b871e028f591</guid>
        <pubDate>2021-06-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.14.2</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPM 300</h3>
<h3>Correction:</h3>
<ul>
<li>Fixed issue the BTB not could close or open, if the BTB has resolved a blackout</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a64b69e5-f880-4489-8acd-7b7cd1087228</guid>
        <pubDate>2021-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.15.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.15.1</li>
</ul>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>CPU load is now accessible and displayed through the performance widget</li>
<li>Added change of counters to eventlog</li>
<li>CPU load is now a measurement as a Live data value, Modbus address, and accessible as an Analogue Output</li>
<li>Added new counters relating to engine/inverter starts.</li>
<li>Added new counters relating to breaker operations</li>
<li>Added energy import and difference counters to hybrid</li>
<li>Added external breaker states to custom logic</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Counters are now specifically signed or un-signed</li>
<li>Changed text on livedata screen for Engine speed</li>
<li>Custom logic bit outputs will now be set back to 0 then deleting from CL configuration</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>"Different power management rules activate" alarm triggered incorrectly</li>
<li>Corrected behavior of continues breaker</li>
<li>Fixed missing paths for Modbus "Inhibited" flags</li>
<li>Fixed issue where display jumps to sync. view if an trip alarm occurs</li>
<li>Fixed issue where "ball" on synchronization view could change between red and green, then the breaker was closed</li>
<li>Fixed issue with alarm counter does not increamet if state not was State A - Normal</li>
<li>Fixed issue stand alone EDG will not deload GB in semi.</li>
<li>Fixed issue where scale "(4 to 20mA) to (0 to 100%)" shows 4.0mA instead of 0.0mA on GAM3.1</li>
</ul>
<h3>DU 300</h3>
<h3>Changes:</h3>
<ul>
<li>Font size and duration of error message increased in the virtual keyboard.</li>
<li>New counters icon for alignment with PICUS.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>"Missing" counters removed from the display.</li>
<li>Units shown for the I/O terminals.</li>
<li>Counters are now limited based on the counter type.</li>
<li>Display restarts on I/O pages when fieldbus configuration is updated.</li>
<li>LED's no longer light up before the screens become active.</li>
<li>Passwords with special characters can now be used from the display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5c86cc21-06f9-4a0e-95a8-dcfa86cbc8e0</guid>
        <pubDate>2021-10-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.16.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.16.0</li>
</ul>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>Added ANSI code tag to relevant alarms</li>
<li>Added possibility for disabling Ethernet ports</li>
<li>Added REST version to version page</li>
<li>Added solo supply in harbour mode functionality</li>
<li>Added any functionality to ICC flags</li>
<li>Increase number of ICC flags to 32</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue where GAM3.2 stand alone was active when regulator was set "OFF"</li>
<li>Fixed issue where the status text would change really fast in some special priority change scenarios</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Support for Tags:<br />
<ul>
<li>New menu for options to display the tags set in parameters.</li>
<li>Options for tag visualisation include: Alarm pop-up, alarm list, logs page and parameter page.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Update to languages</li>
<li>Connection improvements</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solves an issue where the display could enter a manual loop after returning from synchroscope.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">75e22d57-7938-4930-b6d1-2c1e5a2bd481</guid>
        <pubDate>2022-04-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.18.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.18.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.18.0</strong></p>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>Added possibility to disable display buttons in individual groups</li>
<li>Added functionality to avoid the unintended start of extra DGs</li>
<li>Status output indicating if an engine test is running on EDG.</li>
<li>Reset horn is possible to reset with input</li>
<li>Added possiblity to add undervoltage coil into design</li>
<li>Added control signal to engine communication + extra protocols</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Change the maximum value for Breaker close failure delay to 30 seconds</li>
<li>Change the maximum value for Breaker Pulse ON time to 60 seconds</li>
<li>Changed text on BTB then closed is requested, but blackout recovery is not allowed</li>
<li>Load dependent start stop flickering between start timer and not active</li>
<li>Action for the synchronization failure alarm is now visible in PICUS and DU.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fix issue there GAM3.2 stand alone was active when regulator was set "OFF"</li>
<li>Fixed issue where the status text would change really fast in some special priority change scenarios</li>
<li>Load dependent stop block will now block gensets from stopping in case of priority shift or PMS-controlled stop.</li>
<li>DG will no longer open and close without reason after priority shift (in special load scenarios)</li>
<li>Fixed issue with alarm test, does not work when alarm state was unacknowledged no alarm</li>
<li>Fixed issue where synchronization of tiebreaker does not jump to sync. view</li>
<li>Slow response when change EIC protocol is fixed</li>
<li>Fixed issue where synchronize indicator on display is visible with dead busbars</li>
<li>Fixed problem where Picus would show empty Application or I/O status page.</li>
<li>Fixed issue where measurement averaging has causing a very small offset the the averaged measurement.</li>
<li>Fixed issue where emulated values was slower when using measurement averaging.</li>
<li>Fixed issue where the additional logged values in the event log could be incorrect when measurement average is used.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>DU300 button management. <br />
<ul>
<li>Added the ability to disable (and enable) the buttons of the DU300 by parameters.</li>
<li>The buttons are disabled in blocks related to their functionality.</li>
<li>This provides more possibilities to configure the controller to the application's requirements.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue with the differentiation of two synchroscopes with the same measurements, like an EDG.</li>
<li>Fixed an issue related to ANSI codes shown on the alarm popup.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.19.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-19-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">35884749-1d5e-453e-abb0-b8fce7c8af91</guid>
        <pubDate>2022-07-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.19.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.19.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.18.0</strong></p>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>Freeze regulators<br />
<ul>
<li>Added the possibility to freeze the regulators with a digital input.</li>
<li>Added the possibility to freeze the regulators with CustomLogic.</li>
<li>Added the possibility to freeze the regulators via Modbus.</li>
<li>Added a status text to indicate when the regulation is frozen.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Hybrid controller can now transition from PTI to PTO, even when there is a positive power flow.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Identification of controllers in Pairing page.
<ul>
<li>Added the ability to send the "Identify" command from the "Pair" page.</li>
<li>This command creates a blinking pattern of the power LED of the PSM3.1 card.</li>
<li>This allows users working in an environment with multiple controllers to easily confirm the controller they wish to pair the display with.</li>
</ul>
</li>
<li>Support for CODESYS custom info pop-up and status text.
<ul>
<li>This allows CODESYS designers to provide better user experience by delivering messaging and status information of the CODESYS application.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Synchroscope page label
<ul>
<li>Added a label to identify the breaker that is being synchronised.</li>
<li>This improves the recognition of the controller being synchronised.</li>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d8df8b97-d7d8-4017-bd8c-36d4cc9acbd4</guid>
        <pubDate>2022-07-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.20.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li style="text-align: left;">ACM3.1 card will not start protections if settings is lost during operation. A power cycle of the controller will be required to restart the protections. Alarm ""ACM protection not running"" will be shown continuously if the problem occurs.</li>
<li style="text-align: left;">Added After-treatment dashboard</li>
<li style="text-align: left;">Custom counters added to CODESYS and Custom logic</li>
<li style="text-align: left;">Extended baseload functionality on SG to allowed start and stop of last genset</li>
<li style="text-align: left;">Added possibility to setup power transformer on genset and hybrid controllers</li>
<li style="text-align: left;">Added possibility to read out how many feeders are connected in PMS on an output</li>
</ul>
<p> </p>
<h3>Changes:</h3>
<ul>
<li>Backup of eventlog changed to get latest 1000 events.</li>
<li>PMS functions are no longer available in stand alone applications</li>
<li>Maximum ON time in AVR parameters looks to be messed up</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Blackout recovery will happen even, when PMS mode change is set to SEMI when missing controller</li>
<li>Fix the issue where EDG only have 1 set of synchronization settings</li>
<li>Fixed - Reboot of controllers required after SW update</li>
<li>Fixed issue where AC protections could change "AC setup" after power cycle of the controller</li>
<li>Fixed issue where regulator change then load is under breaker open setpoint in transition from PTO, and change back again if load increase.</li>
<li>Fixed issue where HC not working correctly in emulation if HC is setup to continuous request</li>
<li>Fixed issue where is not possible to stop SC or SG in emulation, if the breaker was closed</li>
<li>When synchronising using static sync. The GOV and AVR on the syncing controller should no longer give spikes when a blackout happens on busbar.</li>
</ul>
<p> </p>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.20.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">011d087a-c356-4914-a6c3-f1ea993dcde8</guid>
        <pubDate>2022-09-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.20.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>Changes:</h3>
<ul>
<li>Load-dependent stop block will not block genset from stopping in case of PMS-controlled stop, if load limits is fulfilled.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">84fbbcb9-c158-4023-8b6e-028ae2a09f75</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.21.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPM 300</h3>
<h3>New features:</h3>
<ul>
<li>Added last priority command.</li>
<li>Added support for multiple applications with a parameter to select active application and custom plant name. (Not supported by PICUS yet.)</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue where I/O parameter configuration was passed on from one external breaker or a heavy consumer on the single line to another when during commissioning. I/O configuration and parameters are not reset.</li>
<li>Fixed issue where engine ready delay was ignored before regulation.</li>
<li>Fixed issue where manual regulation didn't work in emulation. </li>
<li>Fixed issue where analogue regulation was unstable in emulation.</li>
<li>Fixed issue with GAM3.2 not working in emulation.</li>
<li>Fixed issues with extra DG startup when baseload was enabled.</li>
<li>Actual Power total in % is now showing on DU-300 (Live data) and in PICUS.</li>
<li>Fixed issue where "Ramping to xx" was stuck in status text.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.21.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-21-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e7ef7d3d-6917-4cc5-9703-e25b68acf3fd</guid>
        <pubDate>2022-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.21.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPM 300</h3>
<h3>Changes:</h3>
<p>1 - Fixed issue where controller made a factory reset, then updated from software version 1.0.20.1.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.22.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-22-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d919640c-21f9-4b1b-9a03-7015d2f40ff1</guid>
        <pubDate>2022-12-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.22.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPM 300</h3>
<h3>New feature:</h3>
<ul>
<li>ACM3.2 is now supported by EDG controller</li>
<li>The abillity to toggle the regulator on and off</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Improved backup percentage count in PICUS</li>
<li>Change the maximum value for Breaker open failure delay to 60 seconds</li>
<li>Change the maximum value for Breaker close failure delay to 60 seconds</li>
<li>Change the minimum value for Heavy Consumers - Nominal Settings - Power Factor to 0.1</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>Fixed missing IOM3.4 support.</li>
<li>Fixed issue with PMS controlled stop sequence when running with load dependent start stop calculations in percent. Issue existed when load was within the start and stop limits.</li>
<li>Fixed issue that when using stop command from switchboard in emulation the engine would not stop when running in parallel.</li>
<li>Fixed issue that when engine was stopped there could be Hz on the generator measurements in emulation.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.24.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-24-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">20294f29-e028-45f1-b861-c4db90fcda08</guid>
        <pubDate>2023-04-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.24.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPM 300</h3>
<h3>New feature:</h3>
<ul>
<li>Added feature to allow all controllers to change between semi and auto when changing the mode on one controller.</li>
<li>Added load-dependent start/stop timer running as a status output.</li>
<li>Added new functionality so that 2nd standby is readable on REST.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>When running emulation the "GAM 3.2 not OK" alarm is not enabled.</li>
<li>SC / SG and Mains variants have regulator control available in emulation.</li>
<li>Selection of "Phase-Phase" / "Phase-Neutral" on selected voltage protections are always shown.</li>
<li>Number of digital inputs and outputs increased for CustomLogic (from 20 to 80).</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>Fixed issue where states in emulation were preserved when emulation was not enabled.</li>
<li>Fixed issue where external breaker crashes controller when running in emulation.</li>
<li>Analogue AVR now works in emulation.</li>
<li>Fixed issue where SC and SG sometimes aborted the open request then DG close breaker.</li>
<li>Fixed issue with no tags shown in HMI for AC setup parameter.</li>
<li>Breaker operation counter now increments correctly in emulation.</li>
<li>Fixed issue where MPU wire break alarm was not shown.</li>
<li>Fixed issue with no action on PMS controlled stop if priority was set to delayed priority shift.</li>
<li>Fixed issue where trip breaker output response time exceeded 100 ms if the configuration had been performed in a special order and the controller had not been power cycled.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.24.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-24-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2a183858-d99a-4cd5-a54c-5bf4db4c18e8</guid>
        <pubDate>2023-05-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.24.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>Changes:</h3>
<ul>
<li>Fixed issue with unit not being able to start without an ACM3.1 card.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.24.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-24-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5330be9c-8e09-4de8-a488-8f6ac8c8b276</guid>
        <pubDate>2023-06-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.24.2</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<p> </p>
<h3>Changes</h3>
<ul>
<li>Fixed issue that meant DG and Hybrid controllers could not start and close breaker in SEMI mode after PMS controlled stop alarm was acknowledge.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.25.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">148021fc-d9f3-4dc0-96b6-9d27899a8820</guid>
        <pubDate>2023-07-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.25.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<p> </p>
<h3>New features</h3>
<ul>
<li>Added a third Overload alarm</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.25.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">60473657-c2f2-4a55-bb6f-04ef0877b3c1</guid>
        <pubDate>2023-08-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.25.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<p> </p>
<h3>New features</h3>
<ul>
<li> Updated internal diagnostic system to be more detailed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.25.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-25-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">374e6ee0-0525-49d7-91eb-96bec7350f73</guid>
        <pubDate>2023-09-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.25.2</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<p>&nbsp;</p>
<h3>Changes</h3>
<ul>
<li>Fixed issue where where controller performed an undesired restart due to rare issue in Modbus.</li>
<li>Fixed issue where reading IO status on Modbus could cause undesired restart of the application software.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.26.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5bbb14e2-465d-4807-b67b-d13def17d89e</guid>
        <pubDate>2024-09-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.26.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>New feature:</h3>
<ul>
<li>EIC: Weichai/Baudouin 6M33 protocol added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>HYBRID controller no longer prevents genset from executing load-dependent stop.</li>
<li>EIC/J1939: kPa measurements are shown with the correct unit.</li>
<li>Connecting genset available power no longer affects load sharing on other DGs during ramp up.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.27.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-27-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">20a001c9-b18e-41b3-83f8-da09d81bf842</guid>
        <pubDate>2024-12-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.27.0</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPM 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>New features</h3>
<ul>
<li>Added new alarm: Unknown traffic on DEIF network detection.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where load dependent start point moved.</li>
<li>Fixed issue where NTP/System time could impact thread timing.</li>
<li>J1939: Fixed issue where red lamp&nbsp;was not triggered.</li>
<li>The correct text is now used for the coolant level alarm.</li>
<li>Baudouin 6M33 now uses the correct DM1 version.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.27.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-27-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">33c8d731-2031-4940-b523-1ef4788010b4</guid>
        <pubDate>2026-01-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.27.1</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where asymmetric loadshare shares the power equally and not based on percentages of nominal.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPM 300  &#x2013; v1.0.27.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppm-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-27-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf92a075-c5ec-463f-9fc8-4e723a61708a</guid>
        <pubDate>2026-04-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPM 300 </category>
        <category domain="version">1.0.27.2</category>
          <category domain="release-status">current</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed the EtherCAT® configuration handling to prevent unsafe behaviour.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5fad24b8-db27-4801-97e8-3a47505505ce</guid>
        <pubDate>2021-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.13.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.13.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6336cef5-fa88-41ac-ae85-88369efaa317</guid>
        <pubDate>2020-02-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.5.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.5.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">94cf99ce-139e-4306-8c5d-4d966d7332f7</guid>
        <pubDate>2021-05-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.14.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.14.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bd14e2dc-1ab6-4a3e-aa0f-cbeae1099282</guid>
        <pubDate>2021-10-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.16.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.16.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.7.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-7-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4aac7944-b80a-4b5d-a990-335a9e19ee1d</guid>
        <pubDate>2020-06-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.7.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.7.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fb0874f8-6b67-4460-a08a-892e78a0d031</guid>
        <pubDate>2021-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.15.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.15.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">020bad25-cad6-4488-aa04-2e43c04ff71c</guid>
        <pubDate>2022-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.17.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.17.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">19035937-0443-4e57-af36-33c645ba3be1</guid>
        <pubDate>2022-04-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.18.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.18.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5daa2dda-535a-4b8b-a237-92db4cc7c485</guid>
        <pubDate>2022-08-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.20.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.20.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2c278614-290c-40e8-89a2-289af2fa4e4e</guid>
        <pubDate>2022-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.21.0</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.21.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.26.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-1xx-codesys-&#x5E93;/1-0-26-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8f628018-f2da-41f1-887f-c0cf9a7bb5d8</guid>
        <pubDate>2023-12-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.26.2</category>
          <category domain="release-status">current</category>
          <category domain="product">PPU 300 Standard controller with CODESYS</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for PPU 300 v. 1.0.26.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.14.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0daff721-3e22-400b-a4bc-6de6d6c1afbf</guid>
        <pubDate>2021-06-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.14.1</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPU 300</h3>
<h3>Corrections:</h3>
<ul>
<li>Allows IOM3.4 Firmware revision 1.0.0.2.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.13.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1114e73b-551f-4602-b88d-7e2b235210ad</guid>
        <pubDate>2021-04-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.13.2</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPU 300:</h3>
<h3>Correction:</h3>
<ul>
<li>Fixed issue where controller restarts if writing to oil pressure on Modbus</li>
<li>Included bugfix on EIM3.1</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<p>Changes:</p>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4db99145-1f71-4baf-8408-9ae918ad4783</guid>
        <pubDate>2021-10-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.16.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.16.0</li>
</ul>
<h3>PPU 300</h3>
<h3>New Features:</h3>
<ul>
<li>Added ANSI code tag to relevant alarms</li>
<li>Added possibility for disabling Ethernet ports</li>
<li>Added REST version to version page</li>
<li>Change the behavior of "Update" input for custom parameters in CODESYS</li>
<li>Added any functionality to ICC flags</li>
<li>Increase number of ICC flags to 32</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue where GAM3.2 stand alone was active when regulator was set "OFF"</li>
<li>Fixed issue in CODESYS where custom parameters write FB not working after read FB has been called</li>
</ul>
<h3>DU 300</h3>
<h3>New Features:</h3>
<ul>
<li>Support for Tags:<br />
<ul>
<li>New menu for options to display the tags set in parameters.</li>
<li>Options for tag visualisation include: Alarm pop-up, alarm list, logs page and parameter page.</li>
</ul>
</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Update to languages</li>
<li>Connection improvements</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solves an issue where the display could enter a manual loop after returning from synchroscope.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8ee296aa-5af8-4e37-b29a-2e149fddc724</guid>
        <pubDate>2021-05-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.14.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPU 300:</h3>
<h3>New feature:</h3>
<ul>
<li>Emulation feature is added.</li>
<li>It is now possible to open the breaker when there is a position failure.</li>
<li>All I/O cards and CAN bus values can now be mapped in Modbus.</li>
<li>ECU: Communication failure is added. When communication is expected, but not present, an alarm is triggered.</li>
<li>Live data: J1939 protocol is now available for engine communication.</li>
<li>An option for customers to add CODESYS application version to the version page is added.</li>
<li>Idle run start is added.</li>
<li>Idle run stop is added.</li>
<li>Inhibit for idle run is added.</li>
<li>It is possible to skip Idle Run Stop by requesting "Stop" again.</li>
<li>It is possible to skip Idle Run Start by requesting "Start" again.</li>
<li>CODESYS inputs and outputs are available in Modbus.</li>
<li>CustomLogic inputs and outputs (digital and analogue) are available in Modbus.</li>
<li>Inhibit status for alarms is available in Modbus.</li>
<li>Alarm property "Remove from service" is now available in Modbus.</li>
<li>The external regulation value can now be read in the regulator status tool. </li>
<li>State of the manual regulation input can now be read in the regulator status tool.</li>
<li>The source of regulation can now be read in regulator status tool.</li>
<li>Engine ECU: Process data alarms are added, and it is now possible to get application alarms from either the ECU or an analogue input.</li>
<li>Engine ECU data has been mapped to communication (incl. standard Modbus) and is configurable in flexible Modbus.</li>
<li>New ECU: Auto discover is added and can be activated from either CustomLogic, CODESYS, Modbus, or Commands.</li>
<li>Live data groupings are arranged in groups according to the engine sub systems.</li>
<li>Live data screen view: Now you can see measurements from different sources based on the priority Analogue/IO over ECU.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>The Modbus connections for Idle Time Expired are changed from 100 seconds to 10 seconds.</li>
<li>The default AC setup values are changed.</li>
<li>"AVR trip" location in CustomLogic for Hybrid is cleaned up.</li>
<li>The text for Hybrid is corrected.</li>
<li>Spelling error: "Deloading" is changed to "De-loading".</li>
<li>Phase sequence error text is corrected for Hybrid.</li>
<li>Default settings for blackout detection mismatch alarm are changed.</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>Fixed that Modbus crashed when trying to connect many times, and not getting a new connection.</li>
<li>Fixed an issue with continuous breaker with mismatch between closing failure and output states.</li>
<li>Breaker operation counter increment is now working.</li>
<li>Load sharing miscalculation for SG is corrected.</li>
<li>Trip counter is now incremented for Hybrid when a trip occurs.</li>
<li>Shore and shaft supervision status is fixed.</li>
<li>Fixed an issue where default max value for EIM3.1 resistance analogue input sensor was to high.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c7395800-2166-4900-bd64-30a384a4506c</guid>
        <pubDate>2021-02-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.13.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<p>Versioning changed for alignment within platform.</p>
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.14.0</li>
</ul>
<h3>PPU 300:</h3>
<h3>New features:</h3>
<ul>
<li>AC measurement averaging:<br />
<ul>
<li>It is now possible to use averaging filters (200ms and 800ms) to reduce the value fluctuations from the high performance of the measurement cards.</li>
<li>The averaging filter can be applied selectively to different types of measurements.</li>
<li>AC measurement averaging affects data displayed by DU 300, PICUS, trending, CustomLogic, CODESYS, and Modbus.</li>
<li>AC measurement averaging does not affect protections and regulation values.</li>
</ul>
</li>
<li>EIM3.1 Safety shutdown function:<br />
<ul>
<li>EIM3.1 can now be used as a safety shutdown module.</li>
<li>EIM 3.1 will be able to run the engine in stand-alone mode should it no longer be able to communicate with the main processor card (PCM).</li>
</ul>
</li>
<li>Hybrid controller type added.</li>
<li>Support of electronic engines protocols (EIC):</li>
<li>Supports the Generic J1939 protocol for reading.</li>
<li>J1939 values, alarms and historical events are now available.</li>
<li>New engine measurement inputs + alarms added for: Oil pressure, Oil temperature, Coolant temperature, and Coolant level.</li>
<li>Flexible application drawing:<br />
<ul>
<li>It is now possible to customise the application drawings to provide a customisable interface.</li>
<li>The design of applications with multiple ring connections is now supported.</li>
</ul>
</li>
<li>CODESYS version information:<br />
<ul>
<li>It is now possible to readout CODESYS versions in PICUS in the information tab.</li>
<li>It is now possible to readout if the licence key is active or not.</li>
<li>It is now possible to readout what type of license is active.</li>
</ul>
</li>
<li>CustomLogic IO added to Flexible Modbus</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Update rate of live data in display and PICUS is increased.</li>
<li>Changed: Possible to change time and date individually from PICUS.</li>
<li>The password length can now be 1 to 32 characters.</li>
<li>New default password is "0" for all users.</li>
<li>Controller type can now be changed during backup restoration.</li>
<li>Changed parameter menu structure for Cos Phi set point. Set point, offset and limit.</li>
<li>When changing single-line diagram - cleaning up alarms related to redundant breaker.</li>
</ul>
<h3><br />Corrections:</h3>
<ul>
<li>Issue fixed where breaker opened before breaker open point is reached.</li>
<li>Fixed issue where hidden Modbus addresses was accessible.</li>
<li>Fixed issue where NELs trip if breaker is opened.</li>
<li>Fixed issue with rounding problems on decimal values on Modbus data.</li>
<li>Fixed issue where changing of counters from Modbus not was saved if there was a controller power cycle shortly after.</li>
<li>Fixed issue where remote and local LEDs both were turned on.</li>
<li>Fixed issue with unsupported functions in CODESYS libraries.</li>
<li>Fixed issue where trip output does not activate when "breaker position failure" is active.</li>
<li>Fixed issues where custom parameters in CODESYS stop working after multiple downloads of CODESYS application.</li>
<li>Fixed rare issue where backup file was corrupted.</li>
<li>Fixed issue where custom alarms do not get units in the alarm and event logs.</li>
<li>Fixed issue where GAM3.2 stand-alone mode does not work with PWM output.</li>
<li>Fixed issue where regulator did not reset on external stop.</li>
<li>Fixed issue where extended stop delay was skipped on external stop.</li>
<li>Alarm timer expired flag data added to Modbus.</li>
<li>Fixed issue where BTB was not deloaded by DG.</li>
<li>Fixed issue where different controller software will run in same system.</li>
<li>Fixed issue where breaker open signal could be sent because of missing inhibit info on ACM3.2.</li>
<li>Fixed issue where AMC3.2 protections did not work on the Shaft generator.</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Custom alarm action suppression: It is now possible to enable alarm suppression for custom alarms from the display.</li>
<li>Fast data interface: Faster update rate of gauges, counters, status texts, and live data views.</li>
<li>Engine communication:<br />
<ul>
<li>J1939 alarms and historical events.</li>
<li>Fieldbus, configuration, supervision and CANbus error handling.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed translation of texts in the View designer.</li>
<li>Fixed translation of message box popup breadcrumb.</li>
<li>Fixed DU300 live data subheader text cutting lower case p, g, j, q, y letters.</li>
<li>Fixed DU300 showing negative ampere.</li>
<li>Fixed conversion between C and F not having effect on scaling (View design).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.7.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-7-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7ce9823a-525a-4687-9ce7-230ef16d233a</guid>
        <pubDate>2020-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.7.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.11.0</li>
</ul>
<h3>PPU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Support for the new IOM3.2 and IOM3.3 cards.</li>
<li>Derate of nominal power is now possible with an analogue input.</li>
</ul>
<h3>Correction:</h3>
<ul>
<li>Fixed an issue where PICUS supervision would update if the regulator type was changed.</li>
<li>Fixed an issue where EIM3.1 relay 4 wire breaker supervision was not working.</li>
<li>Fixed an issue where IOM3.4 custom texts could be mixed up if more than one card were used. This fix result in a break of backward compatibility, if custom text has been used on IOM3.4 cards.</li>
<li>Fixed an issue where adding a previously used extension rack to a new system could cause the controller to restart.</li>
<li>Fixed an issue where connection to an extension unit could cause the controller to restart in a system with more than two extension units.</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Support of IOM3.2 and IOM3.3.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.13.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-13-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">857ecd29-da8f-471f-9528-3f45906b856e</guid>
        <pubDate>2021-02-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.13.1</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.15.0</li>
</ul>
<h3>PPU 300:</h3>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue where the link status of a CODESYS digital output was not correct after download/restore.</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Synchroscope view.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Local display configurations (for example, brightness and units) will now be kept when new application software is installed.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Bar graphs and gauges animations performance is increased.</li>
<li>Fixed an issue in View Design where up/down keys lost focus after a blue pop-up.</li>
<li>Fixed an issue in Parameters where up/down buttons would not be shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c14aaf5e-dec1-46b7-9747-5ca47f3902b3</guid>
        <pubDate>2021-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.15.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.15.1</li>
</ul>
<h3>PPU 300</h3>
<h3>New Features:</h3>
<ul>
<li>CPU load is now accessible and displayed through the performance widget.</li>
<li>Change of counters is added to the event log.</li>
<li>CPU load is now a measurement shown as a Live data value or a Modbus address, and it is accessible as an Analogue Output.</li>
<li>New counters relating to engine/inverter starts are added.</li>
<li>New counters relating to breaker operations are added.</li>
<li>Energy import and difference counters are added to hybrid.</li>
<li>External breaker states are added to CustomLogic.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Counters are now specifically signed or un-signed.</li>
<li>Text on Live data screen is changed for Engine speed.</li>
<li>CustomLogic bit outputs are now reset to 0, and then deleted from the configuration.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Corrected that "Different power management rules activate" alarm was triggered incorrectly.</li>
<li>Corrected the behaviour of Continuous breaker.</li>
<li>Corrected missing paths for Modbus "Inhibited" flags.</li>
<li>Corrected an issue where the display would jump to sync. view if a trip alarm occurred.</li>
<li>Corrected an issue where "ball" on the synchronization view could change between red and green, when the breaker was closed.</li>
<li>Corrected an issue where the alarm counter did not increment if the state was not State A – Normal.</li>
<li>Corrected an issue where a Stand-alone EDG would not deload the GB in SEMI-AUTO mode.</li>
<li>Corrected an issue where the scale "(4 to 20mA) to (0 to 100%)" displayed 4.0mA instead of 0.0mA on GAM3.1.</li>
</ul>
<h3>DU 300</h3>
<h3>Changes:</h3>
<ul>
<li>Font size and duration of error message increased in the virtual keyboard.</li>
<li>New counters icon for alignment with PICUS.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>"Missing" counters removed from the display.</li>
<li>Units shown for the I/O terminals.</li>
<li>Counters are now limited based on the counter type.</li>
<li>Display restarts on I/O pages when fieldbus configuration is updated.</li>
<li>LED's no longer light up before the screens become active.</li>
<li>Passwords with special characters can now be used from the display.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5f23f43b-e750-4bdc-aba9-e6eaaf8978b9</guid>
        <pubDate>2022-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.17.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.17.0</li>
</ul>
<h3>PPU 300</h3>
<h3>New Features:</h3>
<ul>
<li>For CODESYS application it is now possible to have a function block for special hardware, without having the hardware.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Changed the maximum value for Breaker close failure delay to 30 seconds.</li>
<li>Changed the maximum value for Breaker Pulse ON time to 60 seconds.</li>
</ul>
<h3>DU 300</h3>
<h3>Changes:</h3>
<ul>
<li>Improved navigation and look of the Parameters page.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Solved an issue that would cause the DU 300 to crash when downgrading DU software.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.18.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-18-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e1216a76-5d4a-4bcf-b264-e21bb976d8d5</guid>
        <pubDate>2022-04-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.18.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.18.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.18.0</strong></p>
<h3>PPU 300</h3>
<h3>New feature:</h3>
<ul>
<li>Added custom alarms in CODESYS</li>
<li>Added possibility to disable display buttons in individual groups</li>
<li>Added control signal to engine communication + extra protocols</li>
<li>Reset horn is possible to reset with input</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Action for the synchronization failure alarm is now visible in PICUS and DU.</li>
<li>Fixed issue where counters does not work in Custom Logic</li>
<li>Fixed issue where synchronize indicator on display is visible with dead busbars</li>
<li>Fixed issue with alarm test, does not work when alarm state was unacknowledged no alarm</li>
<li>Fixed problem where Picus would show empty Application or I/O status page.</li>
<li>Fixed issue where measurement averaging has causing a very small offset the the averaged measurement.</li>
<li>Fixed issue where emulated values was slower when using measurement averaging.</li>
<li>Fixed issue where the additional logged values in the event log could be incorrect when measurement average is used.</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>DU300 button management. <br />
<ul>
<li>Added the ability to disable (and enable) the buttons of the DU300 by parameters.</li>
<li>The buttons are disabled in blocks related to their functionality.</li>
<li>This provides more possibilities to configure the controller to the application's requirements.</li>
</ul>
</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed an issue with the differentiation of two synchroscopes with the same measurements, like an EDG.</li>
<li>Fixed an issue related to ANSI codes shown on the alarm popup.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0d1a1ed5-9f82-4c43-b85e-448f70f75053</guid>
        <pubDate>2022-07-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.20.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>New feature:</h3>
<ul>
<li>Added Aftertreatment dashboard</li>
<li>Added possibility to create custom popups from CODESYS</li>
<li>Added possibility to set custom status text from CODESYS</li>
<li>Custom counters added to CODESYS and Customlogic</li>
<li>Added possibility to setup power transformer on genset and hybrid controllers</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Backup of eventlog changed to get latest 1000 events.</li>
<li>Corrected min, max and default value for AVR relay output Maximum ON time</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>ACM3.1 card will not start protections if settings is lost during operation. A power cycle of the controller will be required to restart the protections. Alarm ""ACM protection not running"" will be shown continuously if the problem occur.</li>
<li>Fix the issue there EDG only have 1 set of synchronization settings</li>
<li>Fixed - Reboot of controllers required after SW update</li>
<li>Fixed issue where AC protections could change "AC setup" after power cycle of the controller</li>
<li>Fixed issue where is not possible to stop SC or SG in emulation, if the breaker was closed</li>
<li>When synchronising using static sync. The GOV and AVR on the syncing controller should no longer give spikes when a blackout happens on busbar.</li>
</ul>
<h3>DU 300:</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">66f39a03-c08f-46a1-989e-28dbb155e011</guid>
        <pubDate>2022-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.21.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>New feature:</h3>
<p>1 - Added support for multiple applications with a parameter to select active application and custom plant name. (Not supported by PICUS yet.)<br />2 - Added possibility to adjust frequency offset for power load share regulating.</p>
<h3>Corrections:</h3>
<p>1 - Fixed bug where SC does not close, because sync. never finishes in emulation.<br />2 - Fixed issue where "Ramping to xx" was stuck in status text.<br />3 - Fixed issue where IO parameter configuration was passed on from one external breaker or a heavy consumer on the single line to another during commissioning. IO configuration and parameters are not reset.<br />4 - Fixed issue where engine ready delay was ignored before regulation.<br />5 - Fixed issue where manual regulation didn't work in emulation. <br />6 - Fixed issue where analogue regulation was unstable in emulation.<br />7 - Fixed issue with GAM3.2 not working in emulation.<br />8 - Actual power total in % is now showing on DU-300 (Live data) and in PICUS.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.21.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-21-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">04a68a69-73c9-4459-8ff4-2f719e54abb7</guid>
        <pubDate>2023-03-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.21.1</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>Corrections:</h3>
<p>1 - Fixed issue where the voltage offset in reactive power load share did not react</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.26.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7b79e08e-cd78-4152-8e76-6503eae30e6b</guid>
        <pubDate>2023-12-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.26.0</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>New features:</h3>
<p>• Added emergency stop alarm to the parameter list. <br />• Added "Three-phase UL1L2 &amp; IL1" as a new wiring mode option in the AC configuration.</p>
<h3>Corrections:</h3>
<p>• Corrected an issue where it was possible to override an application output from Modbus.<br />• Corrected an issue where the controller performed an unwanted restart due to an uncommon issue in Modbus.<br />• Corrected an issue where reading the IO status on Modbus could cause an unwanted restart of the application software. <br />• Corrected an issue where digital outputs stayed high after removing the configuration.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.26.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">da22f4a4-77fb-40ad-a48d-785512af5a18</guid>
        <pubDate>2023-12-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.26.1</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>Corrections:</h3>
<p>• Optimised CPU performance.<br />• Fixed issue where engine cooldown was not stopped when changed to switchboard control.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.26.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6a244b2c-4d5f-4b21-b1ab-c139ea284520</guid>
        <pubDate>2023-12-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.26.2</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>Changes:</h3>
<p>• Updated CODESYS libraries.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.26.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">91a20dd3-07cf-4b7f-8e79-346068fc7fb4</guid>
        <pubDate>2024-01-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.26.3</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>Changes:</h3>
<p>•Fixed issue where the controller crashed creating a backup.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.26.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-5/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f24dd402-2772-4e96-972d-13a00a2ca8cd</guid>
        <pubDate>2025-08-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.26.5</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, PPU 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3>PPU 300</h3>
<h3>Changes:</h3>
<ul>
<li>Updated ACM3.1 software version from 5.0.5.1 to 5.0.6.0</li>
<li>Added alarm: Breaker configuration failure</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 PPU 300  &#x2013; v1.0.26.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-ppu-300-&#x8F6F;&#x4EF6;-1xx-&#x7248;&#x672C;/1-0-26-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e431d351-04d3-4de9-804c-4ff1e5368c92</guid>
        <pubDate>2026-04-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 PPU 300 </category>
        <category domain="version">1.0.26.6</category>
          <category domain="release-status">current</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed the EtherCAT® configuration handling to prevent unsafe behaviour.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 Service Update &#x2013; v201910</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-&#x670D;&#x52A1;&#x66F4;&#x65B0;-201910/201910/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b2bae92e-2b76-46af-9f2b-1801f7236e3b</guid>
        <pubDate>2019-10-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 Service Update</category>
        <category domain="version">201910</category>
          <category domain="product">GPU 300</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300 Base Unit (BU) package with BSP (version 3.0.1.1)</li>
<li>Multi-line 300 Display Unit (DU) package with BSP and application (BSP version 3.0.0.1 and appl. version 1.0.10.1)</li>
<li>Multi-line 300 PICUS tool (version 1.0.9.3)</li>
<li>Service update information and guideline (201910)</li>
</ul>
<h3>Changes:</h3>
<p>The service update handles an issue related to the software administration of the built-in memory in ML 300 controller.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 Service Update &#x2013; v202006</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-&#x670D;&#x52A1;&#x66F4;&#x65B0;-201910/202006/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">79c605ed-3740-4eed-9902-a4efcf0d7c4e</guid>
        <pubDate>2020-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 Service Update</category>
        <category domain="version">202006</category>
          <category domain="release-status">current</category>
          <category domain="product">GPU 300</category>
          <category domain="product">PPM 300</category>
          <category domain="product">PPM 300 Bus tie breaker controller</category>
          <category domain="product">PPM 300 Emergency genset controller</category>
          <category domain="product">PPM 300 Genset controller</category>
          <category domain="product">PPM 300 Hybrid controller</category>
          <category domain="product">PPM 300 Shaft generator controller</category>
          <category domain="product">PPM 300 Shore connection controller</category>
          <category domain="product">PPU 300</category>
          <category domain="product">PPU 300 Hybrid (battery) controller</category>
          <category domain="product">PPU 300 Standard controller</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300 Base Unit (BU) package with BSP (version 3.0.1.2)</li>
<li>Multi-line 300 Display Unit (DU) package with BSP and application (BSP version 3.0.0.2 and appl. version 1.0.13.0)</li>
<li>Multi-line 300 PICUS tool (version 1.0.12.0)</li>
<li>Service update information and guideline (202006)</li>
</ul>
<h3>Changes:</h3>
<p>The service update handles an issue related to the software administration of the built-in memory in ML 300 controller.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR USW &#x2013; v1.4.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-4-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4918967f-7d92-4362-aa18-1599e8cd586f</guid>
        <pubDate>2020-01-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR USW</category>
        <category domain="version">1.4.1</category>
          <category domain="product">MVR-200 series</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G215</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
          <category domain="product">MVR-V211</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>MVR 21X</li>
<li>MVR 25X</li>
</ul>
<h3>​</h3>
<h3>New features:</h3>
<ul>
<li>Initial release</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR USW &#x2013; v1.4.1.423</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-4-1-423/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bb90c3c2-1447-4488-903c-fbf49990de31</guid>
        <pubDate>2021-08-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR USW</category>
        <category domain="version">1.4.1.423</category>
          <category domain="product">MVR-200 series</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G215</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
          <category domain="product">MVR-V211</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>MVR 21X</li>
<li>MVR 25X</li>
</ul>
<h3>Patch notes:</h3>
<ul>
<li>Creation of offline .aqs file corrected</li>
<li>Upload of .aqs file corrected</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR USW &#x2013; v1.4.1.148</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-4-1-148/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">244337bc-2773-4c05-b72c-affc4ce9a60a</guid>
        <pubDate>2020-01-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR USW</category>
        <category domain="version">1.4.1.148</category>
          <category domain="product">MVR-200 series</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G215</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
          <category domain="product">MVR-V211</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>MVR 21X</li>
<li>MVR 25X</li>
</ul>
<h3>Patch notes:</h3>
<ul>
<li>Improved graphical presentation</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR USW &#x2013; v1.5.1.38</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-5-3-38/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">93cce49f-374f-464f-9a48-1bc845d8c4c4</guid>
        <pubDate>2023-05-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR USW</category>
        <category domain="version">1.5.1.38</category>
          <category domain="product">MVR-200 series</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G215</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
          <category domain="product">MVR-V211</category>
        <content:encoded><![CDATA[
<h3>This software applies to the following DEIF products:</h3>
<ul>
<li>MVR 21X</li>
<li>MVR 25X</li>
</ul>
<h3>Patch notes:</h3>
<ul>
<li>
<p>Support MVR firmware:</p>
<p>- 2.5.7.1-85 for MVR types F255/M255/M257/G257/T256/T257<br />- 2.1.1.3-176 for MVR types F201/F205/F210/F215/M210/M215/G215/T215/T216/V211</p>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR USW &#x2013; v1.5.3-1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-5-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">12771b44-dde8-4274-8817-fa7bd5d221cd</guid>
        <pubDate>2025-02-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR USW</category>
        <category domain="version">1.5.3-1</category>
          <category domain="product">MVR-200 series</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G215</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
          <category domain="product">MVR-V211</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>T-card to rear panel view.&nbsp;</li>
<li>Firmware version to MVR USW top left corner.&nbsp;</li>
<li>Allow copying of device data from infobox.&nbsp;</li>
<li>Lots of missing mapping to 61850.&nbsp;</li>
<li>C++ redistributable to installer.&nbsp;</li>
<li>Support for export logic view to PDF.&nbsp;</li>
<li>Alarm colour selector in 250 mimics.</li>
<li>Programmable stages mapping to IEC 61850.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Changed default IP address to front port.&nbsp;</li>
<li>Mimic colours now follow the colour theme.&nbsp;</li>
<li>Updated Chinese translations.</li>
<li>Event history: Adjusted the column order to timestamp first.</li>
<li>Re-ordered GSE nodes to match GSE Control nodes.</li>
</ul>
<h3>&nbsp;Corrections</h3>
<ul>
<li>Fixed check for updates functionality.&nbsp;</li>
<li>Fixed type of BCR.actVal to match 61850 edition 2.&nbsp;</li>
<li>Fixed issue with incorrect decimal places in some parameters for older firmwares. &nbsp;</li>
<li>Fixed some descriptions in 61850 CID.&nbsp;</li>
<li>Fixed RTD card size in rear panel view.&nbsp;</li>
<li>Fixed issue with some menus not being loaded.</li>
<li>Fixed SPA map saving. Does not overwrite existing file even when confirmed.&nbsp;</li>
<li>Fixed communication map descriptions and added missing mappings.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR USW &#x2013; v1.5.4.16</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/1-5-4-16/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">42f539b8-0411-41b4-b9ca-6d8dada9cfb6</guid>
        <pubDate>2026-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR USW</category>
        <category domain="version">1.5.4.16</category>
          <category domain="release-status">current</category>
          <category domain="product">MVR-200 series</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G215</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
          <category domain="product">MVR-V211</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Updates can now be applied directly via the front port, enabling faster and more convenient on-site upgrades.</li>
<li>Prepared for compatibility with upcoming cybersecurity updates for MVR, which will be introduced in future firmware updates.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Reduced memory usage during file transfers and after closing AQS files, resulting in smoother operation and improved system responsiveness.</li>
<li>Improved parameter look-up speed, reducing time required for configuration and troubleshooting.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>N-options firmware &#x2013; v2.40.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/n-&#x9009;&#x9879;&#x8F6F;&#x4EF6;/2-40-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f9c1cd7a-cbc8-4a9b-8ffd-149013b16f25</guid>
        <pubDate>2015-06-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">N-options firmware</category>
        <category domain="version">2.40.1</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">GPC-3</category>
          <category domain="product">AGC-3</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<ul>
<li>Some modbus registers were updated slowly and some not at all. Now all registers are updated as fast as they used to.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>N-options firmware &#x2013; v2.41.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/n-&#x9009;&#x9879;&#x8F6F;&#x4EF6;/2-41-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">11f12991-ae66-4a78-9474-19ee397867ae</guid>
        <pubDate>2017-11-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">N-options firmware</category>
        <category domain="version">2.41.0</category>
          <category domain="release-status">current</category>
          <category domain="product">ASC-4 Battery</category>
          <category domain="product">ASC-4 Battery Single Controller</category>
          <category domain="product">ASC-4 Solar</category>
          <category domain="product">ASC-4 Solar Single controller</category>
          <category domain="product">GPC-3</category>
          <category domain="product">AGC-3</category>
          <category domain="product">AGC-4</category>
        <content:encoded><![CDATA[
<p>Corrections:<br />        - Dropbear (SSH server) updated from version 47 to version 74<br />        - EtherNet/IP object 6E + 6F updated<br />- SSH key generation changed to single thread to avoid requirement for double boot after enabling SSH server</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>RTC 300 and RTC 600 CANOpen EDS-file &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/rtc-300&#x548C;rtc-600-canopen-eds-&#x8F6F;&#x4EF6;&#x5305;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">272ffba0-b31c-4bc6-9e80-ec5e113c6d16</guid>
        <pubDate>2018-09-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">RTC 300 and RTC 600 CANOpen EDS-file</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">RTA &amp; RTC</category>
        <content:encoded><![CDATA[
<p>Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SD Datalog Software &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sd&#x5361;&#x6570;&#x636E;&#x8BB0;&#x5F55;&#x8F6F;&#x4EF6;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">690d83d7-531e-4def-9944-3672495013f6</guid>
        <pubDate>2011-03-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SD Datalog Software</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AEM 380 &amp; 305</category>
          <category domain="product">APM 380 &amp; 305</category>
        <content:encoded><![CDATA[
<p>Initial version</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect &#x2013; v2.2.2.36</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-&#x667A;&#x80FD;&#x8FDE;&#x63A5;&#x8F6F;&#x4EF6;/2-2-2-36/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8359413f-1d99-4862-9044-484c6822936b</guid>
        <pubDate>2020-12-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect</category>
        <category domain="version">2.2.2.36</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 421</category>
        <content:encoded><![CDATA[
<h3>Initial release:</h3>
<ul>
<li>  Support SGC 1X series</li>
<li>  Support SGC 4X series</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect &#x2013; v5.5.5.46</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-&#x667A;&#x80FD;&#x8FDE;&#x63A5;&#x8F6F;&#x4EF6;/5-5-5-46/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6578a094-b199-48f6-ac84-41b0b130127f</guid>
        <pubDate>2023-01-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect</category>
        <category domain="version">5.5.5.46</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 421</category>
        <content:encoded><![CDATA[
<h3>New features release:</h3>
<p>DEIF Smart Connect SW for SGC 1xx and 4xx<br />Supports SGC 110 R6.0 and previous versions.<br />Supports SGC 120 R8.0 and previous versions.<br />Supports SGC 121 R6.0 and previous versions.<br />Supports SGC 410 R6.0 and previous versions.<br />Supports SGC 420 R7.0 and previous versions.<br />Supports SGC 421 R6.0 and previous versions.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect &#x2013; v5.5.7.24</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-&#x667A;&#x80FD;&#x8FDE;&#x63A5;&#x8F6F;&#x4EF6;/5-5-7-24/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c52ad43f-7214-4501-b7db-448b8fcaff36</guid>
        <pubDate>2023-08-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect</category>
        <category domain="version">5.5.7.24</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 421</category>
        <content:encoded><![CDATA[
<h3>New features release:</h3>
<p>DEIF Smart Connect SW for SGC 1xx and 4xx</p>
<p>Changes<br />• Supports SGC 110 R6.0 and previous versions.<br />• Supports SGC 120 R9.0 and previous versions.<br />• Supports SGC 121 R6.0 and previous versions.<br />• Supports SGC 410 R6.0 and previous versions.<br />• Supports SGC 420 R8.0 and previous versions.<br />• Supports SGC 421 R6.0 and previous versions.<br />• Chinese and Spanish language features updated.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect &#x2013; v5.5.7.29</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-&#x667A;&#x80FD;&#x8FDE;&#x63A5;&#x8F6F;&#x4EF6;/5-5-7-29/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">615affee-cbfd-453f-89e9-6f86c386392c</guid>
        <pubDate>2023-09-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect</category>
        <category domain="version">5.5.7.29</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 421</category>
        <content:encoded><![CDATA[
<p>DEIF Smart Connect SW for SGC 1xx and 4xx</p>
<p>Changes<br />• Supports SGC 110 R6.0 and previous versions.<br />• Supports SGC 120 R9.0 and previous versions.<br />• Supports SGC 121 R6.0 and previous versions.<br />• Supports SGC 410 R6.0 and previous versions.<br />• Supports SGC 420 R8.0 and previous versions.<br />• Supports SGC 421 R6.0 and previous versions.<br />Correction, Bug fix release</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect &#x2013; v5.5.7.30</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-&#x667A;&#x80FD;&#x8FDE;&#x63A5;&#x8F6F;&#x4EF6;/5-5-7-30/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">440a6f1a-7ee3-4bc3-b341-4006f21ef3e4</guid>
        <pubDate>2023-10-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect</category>
        <category domain="version">5.5.7.30</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 421</category>
        <content:encoded><![CDATA[
<p>DEIF Smart Connect SW for SGC 1xx and 4xx</p>
<p>• Supports SGC 110 R6.0 and previous versions.<br />• Supports SGC 120 R9.0 and previous versions.<br />• Supports SGC 121 R5.0 and previous versions.<br />• Supports SGC 410 R5.0 and previous versions.<br />• Supports SGC 420 R8.0 and previous versions.<br />• Supports SGC 421 R5.0 and previous versions.</p>
<p>Changes<br />• Removed R6.0 version of SGC 121, SGC 410, SGC 421 due to non-availability of hardware.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect &#x2013; v5.5.7.38</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-&#x667A;&#x80FD;&#x8FDE;&#x63A5;&#x8F6F;&#x4EF6;/5-5-7-38/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a5e99b30-0c84-4e51-bdd1-a3787aadbc1f</guid>
        <pubDate>2025-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect</category>
        <category domain="version">5.5.7.38</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 421</category>
        <content:encoded><![CDATA[
<p>DEIF Smart Connect SW for SGC 1xx and 4xx</p>
<h3>Improvements</h3>
<ul>
<li>Compatibility: &nbsp;improved compatibility with Windows 11.&nbsp;</li>
<li>Updated read/write handling from PC with different regional settings.</li>
<li>Nominal power and alternate nominal power minimum value changed to 1 KW.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed decimal point issue in S4 sensor in SGC 420 R8.</li>
<li>Fixed alternate nominal power value preview before saving.</li>
</ul>
<h3>Supported versions:</h3>
<ul>
<li>SGC 120 R9.11 and previous versions.</li>
<li>SGC 420 R8.09 and previous versions.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TAS-3x1-DG Configuration Software &#x2013; v1.22.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tas-3x1-dg-&#x53C2;&#x6570;&#x914D;&#x7F6E;&#x8F6F;&#x4EF6;/1-22/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3c656f1c-4eb0-4eb7-b681-bbf6ea16b4df</guid>
        <pubDate>2006-12-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TAS-3x1-DG Configuration Software</category>
        <category domain="version">1.22.1</category>
          <category domain="release-status">current</category>
          <category domain="product">TAS-311DG</category>
          <category domain="product">TAS-321DG</category>
          <category domain="product">TAS-331DG</category>
        <content:encoded><![CDATA[
<p>Problem with space in download link</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TAS-3x1-DG Configuration Software &#x2013; v1.22.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tas-3x1-dg-&#x53C2;&#x6570;&#x914D;&#x7F6E;&#x8F6F;&#x4EF6;/1-22-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ed9db799-c418-4140-be1e-5e23281f6a91</guid>
        <pubDate>2006-12-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TAS-3x1-DG Configuration Software</category>
        <category domain="version">1.22.0</category>
          <category domain="product">TAS-311DG</category>
          <category domain="product">TAS-321DG</category>
          <category domain="product">TAS-331DG</category>
        <content:encoded><![CDATA[
<p>Extra COM-ports added. COM1 – COM12</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TCM Utility Software &#x2013; v2.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tcm-&#x5B9E;&#x7528;&#x8F6F;&#x4EF6;/2-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8fdf53fd-d431-4fd0-9a8c-9c31c36bf725</guid>
        <pubDate>2011-10-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TCM Utility Software</category>
        <category domain="version">2.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">TCM-2</category>
        <content:encoded><![CDATA[
<p>Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.7.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-7-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">63857499-1062-4b48-9d3d-be8bdc1e2934</guid>
        <pubDate>2021-05-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.7.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support for OEM product IDs in AGC-4 Mk II is added.</li>
<li>Scania EMS S8 support is added..</li>
<li>Block mode button is added.</li>
<li>Master/slave controller manual switch is added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>"AUS" mode for German option V0108 in "Auto" and "Test" mode is added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Alarms are removed from the header when alarm conditions disappear.</li>
<li>Fixed an issue with missing genset modes in the language file.</li>
<li>Fixed that the genset mode would change if the password level was set to service or master.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9ad2ddbf-3597-435b-b3a5-4ae466605852</guid>
        <pubDate>2020-12-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.4.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Supported on AGC-4 DG and AGC-4 Mains.<br />Minimum AGC-4 SW required: 4.74.3.<br />Recommended minimum AGC-4 SW: 4.76.1.<br /><br /></p>
<h3>Corrections:</h3>
<ul>
<li>Customer branding is added.</li>
<li>Fixed the missing alarm texts for EIC alarms.</li>
<li>Fixed the screen lock on the Log page, when updating logs from an empty list.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b6d4ef80-91e3-4296-aa45-7fda91b04a88</guid>
        <pubDate>2021-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.5.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h2>New features:</h2>
<ul>
<li>Added support for AGC-4 Mk II</li>
<li>Added Customer branding</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ee405d60-ef51-4f7c-ac27-dc09f6f5c807</guid>
        <pubDate>2020-11-03T12:57:52&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.3.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Supported on AGC-4 DG and AGC-4 Mains.<br>Minimum AGC-4 SW required: 4.74.3.<br>Recommended minimum AGC-4 SW: 4.76.1.<br><br></p>
<h3>Changes:</h3>
<ul>
<li>Extended search for renamed software packages is added. This means that for releases after 1.3.3.1 the TDU software package will include the version number.&nbsp;</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed connection problems in firmware ver. 1.3.3.0.</li>
<li>Fixed DVC types on the parameter page.</li>
<li>Fixed problems with parameter scaling and drop-down elements on the parameter page and in the USW dialogue.</li>
</ul>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f427cb78-4f3f-42a6-8ed2-dcbcadadc710</guid>
        <pubDate>2020-09-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.3.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Supported on AGC-4 DG &amp; AGC-4 Mains.<br>Minimum AGC-4 SW required: 4.74.3.<br>Recommended minimum AGC-4 SW: 4.76.1.</p>
<h3>New features:</h3>
<ul>
<li>&nbsp; &nbsp;Further brandings are added.</li>
<li>&nbsp; &nbsp;AGC-4 as clock master is added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>&nbsp; &nbsp;New entry point for the ECU measurement window is added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>&nbsp; &nbsp;Parameter max. value was not taken into account for text values.</li>
<li>&nbsp; &nbsp;If exactly 9 alarms was present, the last one was not visible.</li>
<li>&nbsp; &nbsp;Possibility to include system information when exporting a TDU.config file is added.</li>
<li>&nbsp; &nbsp;Generator measurements are removed from mains TDU.</li>
<li>&nbsp; &nbsp;Regeneration parameters are added to TDU.</li>
<li>&nbsp; &nbsp;Application supervision now supports mains with ID 1-16 and DG´s with ID 17-32.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">65b4c295-5175-4e2a-8a1d-8ddb8b2a2e6f</guid>
        <pubDate>2021-03-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.6.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Added support for OEM product IDs in AGC-4 Mk II.</li>
<li>Extra safety pop up (Nominal setting + Plant mode).</li>
<li>Translation file added with "TDU specific texts".</li>
<li>"UpdatePackage.zip" includes software version.</li>
<li>Support updatepackage.zip with lower case characters.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9413c2ad-ced9-436f-b88b-d1ce88f45449</guid>
        <pubDate>2021-12-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.8.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Added option to hide application and nominal settings on instrument pages.</li>
<li>New and updated customer branding.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>IP can't be changed when disabling Master/slave when TDU is connected to slave.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ed1ac18a-f438-4776-869a-d1d02463fd75</guid>
        <pubDate>2022-01-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.9.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>New application select page added to the setup menu.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Toggle switches are more accurate now.</li>
<li>Fixed language export issue with empty AOP labels.</li>
<li>Fixed missing semi button when activating the German AUS mode.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.9.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-9-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">68bf1e42-9f27-45ab-9220-26b2c6229417</guid>
        <pubDate>2022-02-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.9.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Only show measurements supported by the connected ECU.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue with writing alarm settings for parameters</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d2e3d0a9-a016-4a83-83af-08e6c4b42975</guid>
        <pubDate>2022-07-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.10.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Logo and top bar branding.</li>
<li>Branding configuration import and export.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed glitch with negative values in alarm and event log.</li>
<li>Fixed glitch with controller communication lost for 1-2 seconds every 13 or 25 minutes.</li>
<li>Fixed glitch with TDU not able to connect to AGC-4 Mk II Mains controller.s for parameters</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c209ba58-872b-4921-b7f8-495356405814</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.10.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<p>1- Fixed horizontal scrolling of Supervison.<br />2- Fixed missing "None" option in "Instrument Selection".<br />3- Fixed missing Custom Logo in "Log" and "Controller settings" pages.<br />4- Reset index when changing between "Controller settings" lists.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">07488e43-d0b9-426e-9d0a-e398e503e925</guid>
        <pubDate>2023-03-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.11.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for FPT stage V engines.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Created separate pages for "Engine lamps" and "Exhaust aftertreatment".</li>
<li>Added support for tree view translations.</li>
<li>Made opening parameters more intuitive.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7d97c2e7-ce39-4106-9398-10984779df15</guid>
        <pubDate>2023-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.11.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<p>     • Fixed missing application supervision when there is a BTB controller in the application drawing.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.3.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-3-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">32643971-7194-4e53-a5aa-aeed177c90dd</guid>
        <pubDate>2023-08-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.3.12.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>Updated supervision to show hybrid variants.</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>Added support for Volvo EMS.</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>Fixed TDU 107 supervision issue.</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">13627d55-29ce-43fe-a1ff-4660550f623f</guid>
        <pubDate>2023-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.0.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>
<ul>Supervision variant for TDU.</ul>
</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>
<ul>Extended capability to read more VTA's.</ul>
</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II v6.08.0.</ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II BTB.</ul>
</ul>
</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">06431938-af87-4033-bf50-4d1f72596bb2</guid>
        <pubDate>2024-01-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.1.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>
<ul>
<ul>Support for ASC-150</ul>
<ul>Support for ASC-4</ul>
</ul>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">acc93608-9a61-414c-8d1c-510d2dff69d7</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.2.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<p>&nbsp; &nbsp;1- Confirm action pop-ups.</p>
<p>&nbsp;</p>
<h3>Changes</h3>
<p>&nbsp; &nbsp;1- New method for handling translations.<br>&nbsp; &nbsp;2- Tier 4 jump improvements.</p>
<p>&nbsp;</p>
<h3>Corrections</h3>
<p>&nbsp; &nbsp;1- Fixed issue with parameter dialogue not showing the correct state of the toggle switches.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.2.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">52b66dc5-681d-4f90-941b-f4fd46c4b772</guid>
        <pubDate>2024-10-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.2.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue with home page application drawing becoming zoomed out with every power cycle or reboot from TDU restart.</li>
<li>Fixed issue with TDU not connecting with AGC-4 Mk II application software version 6.14.0.</li>
<li>Fixed show/hide of page 2-3 in home.</li>
<li>Resolved issue with inhibit start button, inhibit stop button, inhibit GB/TB button and inhibit MB button commands.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">01bf34e3-bffc-4492-9eba-288d9b863924</guid>
        <pubDate>2024-12-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.3.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>&nbsp; &nbsp;Added support for two additional nominal settings buttons.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>&nbsp; &nbsp;Fixed communication issues with AGC v6.15.x.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0f146fdd-fa04-4d17-8445-faba3fd1b692</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.3.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>This minor update fixes an issue where the TDU is not drawing the application drawing correctly when using BTBs.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fb6e0128-f433-4564-b91f-fe02178b1415</guid>
        <pubDate>2025-03-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.4.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Version 1.4.4.0 based on 1.4.3.1</p>
<h3>Changes</h3>
<ul>
<li>OEM branding via Product ID.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8e1c6b52-34f1-44cb-905f-f8e3a00d53aa</guid>
        <pubDate>2025-04-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.5.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h4>Version 1.4.5.0 based on 1.4.4.0</h4>
<h3>Changes</h3>
<ul>
<li>Show start/stop buttons as grey when in Auto mode.</li>
<li>Improved readability of plant supervision screen.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added missing EIC measurements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Core &#x2013; v1.4.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x57FA;&#x7840;&#x7248;/1-4-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d411e1ab-a6ef-46ab-a198-15cb326a3217</guid>
        <pubDate>2025-10-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Core</category>
        <category domain="version">1.4.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Improved Auto logout/Clear user level after block mode selection.</li>
</ul>
<h3>Corrections:&nbsp;</h3>
<ul>
<li>Resolved issue where the TDU did not show the correct text for certain SPN/FMI values.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10092d46-99e0-45ce-9f7f-805a0469b86f</guid>
        <pubDate>2021-12-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.8.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Added option to hide application and nominal settings on instrument pages.</li>
<li>New and updated customer branding.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>IP can't be changed when disabling Master/slave when TDU is connected to slave.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">62c59d12-449f-4216-9638-86c9fb3253c6</guid>
        <pubDate>2020-06-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.2.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Supported on AGC-4 DG &amp; AGC-4 Mains.<br>Minimum AGC-4 SW required: 4.74.3.<br>Recommended AGC-4 SW: 4.76.1.</p>
<h3>New features:</h3>
<ul>
<li>EIC measurements can now be seen in a separate window.</li>
<li>Added support for new Boolean measurements.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>More texts have been included in the translation file, to extend translation capabilities of the TDU. (Controller texts and Engine DM1/DM2 texts).</li>
<li>Sync shortcut on the home screen now only requires a single press instead of a long press.</li>
<li>Internal references to measurement layout on Modbus have been updated.</li>
<li>Preferred font have been removed from the CSV file.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Current status of the DG on the alternator curve now works properly.</li>
<li>TDU Supervision is now updated correctly when using the Easy connect feature.</li>
<li>Empty AOP texts are now saved during power cycle or in TDU.config files.</li>
<li>"Autojump to sync scope" is now saved during power cycle or in TDU.config files.</li>
<li>The screensaver now shows the "Connection lost" message.</li>
<li>The branded splash screen is now shown correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8dc6aed4-07f4-4228-b1a9-8c3107ecb2ae</guid>
        <pubDate>2021-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.5.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h2>New features:</h2>
<ul>
<li>Added support for AGC-4 Mk II</li>
<li>Added customer branding</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">99ad6836-7138-46f1-8026-e7971bdf64c8</guid>
        <pubDate>2020-09-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.3.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Supported on AGC-4 DG &amp; AGC-4 Mains.<br />Minimum AGC-4 SW required: 4.74.3.<br />Recommended minimum AGC-4 SW: 4.76.1.</p>
<h3>New features:</h3>
<ul>
<li>   Further brandings are added.</li>
<li>   AGC-4 as clock master is added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>   New entry point for the ECU measurement window is added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>   Parameter max. value was not taken into account for text values.</li>
<li>   If exactly 9 alarms were present, the last one was not visible.</li>
<li>   Possibility to include system information when exporting a TDU.config file is added.</li>
<li>   Preventive measures were taken to stabilize the VNC connection.</li>
<li>   Generator measurements are removed from mains TDU.</li>
<li>   Regeneration parameters are added to TDU.</li>
<li>   Application supervision now supports mains with id´s 1-16 and DG´s with ID 17-32.</li>
</ul>
<div>​</div>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.7.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-7-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f8e29737-6303-422a-8454-926974ed66a6</guid>
        <pubDate>2021-05-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.7.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Support for OEM product IDs in AGC-4 Mk II is added.</li>
<li>Scania EMS S8 support is added.</li>
<li>Block mode button is added.</li>
<li>Master/slave controller manual switch is added.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>"AUS" mode for German option V0108 in "Auto" and "Test" mode is added.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Alarms are removed from the header when alarm conditions disappear.</li>
<li>Fixed an issue with missing genset modes in the language file.</li>
<li>Fixed that the genset mode would change if the password level was set to service or master.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">39c3f1a8-70b9-4909-aaa7-36173fe8a878</guid>
        <pubDate>2021-03-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.6.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features:</h3>
<ul>
<li>Added support for OEM product IDs in AGC-4 Mk II.</li>
<li>Extra safety pop up (Nominal setting + Plant mode).</li>
<li>Translation file added with "TDU specific texts".</li>
<li>"UpdatePackage.zip" includes software version.</li>
<li>Support updatepackage.zip with lower case characters.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1678dd01-6195-40e2-9692-cae14573f5ee</guid>
        <pubDate>2022-01-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.9.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>New application select page added to the setup menu.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Toggle switches are more accurate now.</li>
<li>Fixed language export issue with empty AOP labels.</li>
<li>Fixed missing semi button when activating the German AUS mode.</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.9.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-9-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a2155d53-0ab1-4911-9e92-e1c6aa441dc4</guid>
        <pubDate>2022-02-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.9.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Only show measurements supported by the connected ECU.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue with writing alarm settings for parameters</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">35fe1d99-a691-47e5-82ee-f299ef7f3e0b</guid>
        <pubDate>2022-07-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.10.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Logo implementation and top bar branding.</li>
<li>Branding configuration import and export.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed glitch with negative values in alarm and event log.</li>
<li>Fixed glitch with controller communication lost for 1-2 seconds every 13 or 25 minutes.</li>
<li>Fixed glitch with TDU not able to connect to AGC-4 Mk II Mains controller.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f1d4dfa1-0929-4372-aac5-59282ffa4ec7</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.10.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<p>1- Fixed horizontal scrolling of Supervision.<br />2- Fixed missing "None" option in "Instrument Selection".<br />3- Fixed missing Custom Logo in "Log" and "Controller settings" pages.<br />4- Reset index when changing between "Controller settings" lists.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ac0384ae-ff0f-4c5d-a6e8-564440a17524</guid>
        <pubDate>2023-03-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.11.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for FPT stage V engines.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Created separate pages for "Engine lamps" and "Exhaust aftertreatment".</li>
<li>Added support for tree view translations.</li>
<li>Made opening parameters more intuitive.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">364b2521-167f-4619-affb-8c5bac728929</guid>
        <pubDate>2023-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.11.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<p>    • Fixed missing application supervision when there is a BTB controller in the application drawing.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.3.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-3-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">04d70439-ed6f-4bb2-819c-66d8da195ab7</guid>
        <pubDate>2023-08-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.3.12.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>Supervision shows ASC controllers.</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>Added support for Volvo EMS.</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>Fixed TDU 107 supervision issue.</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">08aeff60-cf50-4437-aac5-bc8b835e8403</guid>
        <pubDate>2023-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.0.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>
<ul>Supervision variant for TDU.</ul>
</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>
<ul>Extended capability to read more VTA's.</ul>
</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II v6.08.0.</ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II BTB.</ul>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f5881c68-9f2e-4c1d-bc79-b0715d46a9d1</guid>
        <pubDate>2024-01-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.1.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>
<ul>
<ul>Support for ASC-150.</ul>
</ul>
</ul>
<ul>
<ul>
<ul>Support for ASC-4</ul>
</ul>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5726cca0-1bd0-45d2-9453-a480a8aa5d36</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.2.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<p>&nbsp; &nbsp;1- Confirm action pop-ups.</p>
<p>&nbsp;</p>
<h3>Changes</h3>
<p>&nbsp; &nbsp;1- New method for handling translations.<br>&nbsp; &nbsp;2- Tier 4 jump improvements.</p>
<p>&nbsp;</p>
<h3>Corrections</h3>
<p>&nbsp; &nbsp;1- Fixed issue with parameter dialogue not showing the correct state of the toggle switches.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.2.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f6252dc-fa72-4e4d-9685-86d2320ef701</guid>
        <pubDate>2024-10-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.2.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue with home page application drawing becoming zoomed out with every power cycle or reboot from TDU restart.</li>
<li>Fixed issue with TDU not connecting with AGC-4 Mk II application software version 6.14.0.</li>
<li>Fixed show/hide of page 2-3 in home.</li>
<li>Resolved issue with inhibit start button, inhibit stop button, inhibit GB/TB button and inhibit MB button commands.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">551117a0-8ced-44bc-8586-ebd573400450</guid>
        <pubDate>2024-12-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.3.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>&nbsp;Added support for two additional nominal settings buttons.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed communication issues with AGC v6.15.x.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">384fd901-7801-41ba-81a0-bfd7130ea725</guid>
        <pubDate>2025-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.3.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>This minor update fixes an issue where the TDU is not drawing the application drawing correctly when using BTBs.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0e1d99e5-9e43-4dde-8564-5bd3d146d9bb</guid>
        <pubDate>2025-03-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.4.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Version 1.4.4.0 based on 1.4.3.1</p>
<h3>Changes</h3>
<ul>
<li>OEM branding via Product ID.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ba692aae-3f36-48ef-9c5d-d81f16df11a5</guid>
        <pubDate>2025-04-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.5.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h4>Version 1.4.5.0 based on 1.4.4.0</h4>
<h3>Changes</h3>
<ul>
<li>Show start/stop buttons as grey when in Auto mode.<br>Improved readability of plant supervision screen.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added missing EIC measurements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 107 Extended &#x2013; v1.4.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-107-&#x6269;&#x5C55;&#x7248;/1-4-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">84107ec4-39c4-47f1-88ce-b32dc4d13cb2</guid>
        <pubDate>2025-10-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 107 Extended</category>
        <category domain="version">1.4.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Improved Auto logout/Clear user level after block mode selection.</li>
</ul>
<h3>Corrections:&nbsp;</h3>
<ul>
<li>Resolved issue where the TDU did not show the correct text for certain SPN/FMI values.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TRI-2 CANOpen EDS-file &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tri-2-canopen-eds&#x8F6F;&#x4EF6;&#x5305;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b8920862-6d34-4226-a13c-f3b2c31b7ec8</guid>
        <pubDate>2010-08-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TRI-2 CANOpen EDS-file</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">TRI-2</category>
        <content:encoded><![CDATA[
<p>Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi generic CANopen EDS file &#x2013; v1.01.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-generic-canopen-eds-&#x8F6F;&#x4EF6;&#x5305;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">74d5d904-bfda-47a8-91b6-1df5d4bd2c00</guid>
        <pubDate>2023-10-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi generic CANopen EDS file</category>
        <category domain="version">1.01.0</category>
          <category domain="release-status">current</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<p>Second release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi Upgrade Tool &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-&#x5347;&#x7EA7;&#x5DE5;&#x5177;&#x5305;/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3d02dfb0-600b-49d9-86b4-7515bacbd6f0</guid>
        <pubDate>2017-12-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi Upgrade Tool</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<p>This upgrade tool version contains the new XDi platform 2.00.1 software.<br />It will automatically upgrade XDi platform v.2.00.0 units to platform v.2.00.1 when a new library v.2xxx is installed.<br />This version can also upgrade platform software v2.00.0 to 2.00.1 without uploading the indicator library part again.<br />This means that the already made indicator selection and parameter setup will not be deleted or changed. After the update, the previously selected virtual indicator will start and work as before.<br />Up grade from platform v.1xx.x to 2.00.1 will automatically happen when needed and downgrade to a previous platform 1 library is still possible. </p>
<p>Version 2.0.2.0 based on version 2.0.1.0</p>
<ul>
<li>Support for new platform 2 SW version 2.0.0.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi Upgrade Tool &#x2013; v2.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-&#x5347;&#x7EA7;&#x5DE5;&#x5177;&#x5305;/2-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">107e104b-c642-485d-bd96-96096198e77a</guid>
        <pubDate>2018-03-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi Upgrade Tool</category>
        <category domain="version">2.0.3.0</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<p>This upgrade tool version contains the new XDi platform 2.0.0.2 software.</p>
<p>It will automatically upgrade XDi platform v.2.0.0.0 or 2.0.0.1 units to platform v.2.0.0.2 when a library v.2xxx is installed.</p>
<p>This version can also upgrade platform software v2.0.0.0 &amp; 2.0.0.1 to 2.0.0.2 without uploading the indicator library part again.</p>
<p>This means that the already made indicator selection and parameter setup will not be deleted or changed. After the update, the previously selected virtual indicator will start and work as before.</p>
<p>Upgrade from platform v.1xx.x to 2.0.0.2 will automatically happen when needed and downgrade to a previous platform 1 library is still possible</p>
<p> </p>
<p>Version 2.0.3.0 based on version 2.0.2.0<br />• Support for new platform 2 SW version 2.0.0.2</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi Upgrade Tool &#x2013; v2.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-&#x5347;&#x7EA7;&#x5DE5;&#x5177;&#x5305;/2-0-3-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b0d70df7-4ec5-424f-9c07-5cbd81d1f319</guid>
        <pubDate>2024-02-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi Upgrade Tool</category>
        <category domain="version">2.0.3.0</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<p>This upgrade tool version contains the new XDi platform 2.0.0.2 software.</p>
<p>It will automatically upgrade XDi platform v.2.0.0.0 or 2.0.0.1 units to platform v.2.0.0.2 when a library v.2xxx is installed.</p>
<p>This version can also upgrade platform software v2.0.0.0 &amp; 2.0.0.1 to 2.0.0.2 without uploading the indicator library part again.</p>
<p>This means that the already made indicator selection and parameter setup will not be deleted or changed. After the update, the previously selected virtual indicator will start and work as before.</p>
<p>Upgrade from platform v.1xx.x to 2.0.0.2 will automatically happen when needed and downgrade to a previous platform 1 library is still possible</p>
<p> </p>
<p>Version 2.0.3.0 based on version 2.0.2.0<br />• User Documentation removed from SW zip-file. To be fetched from doc. archive on www.deif.com</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi Upgrade Tool &#x2013; v2.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-&#x5347;&#x7EA7;&#x5DE5;&#x5177;&#x5305;/2-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">de75c237-1da9-4eb6-a607-78426136ea8f</guid>
        <pubDate>2024-10-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi Upgrade Tool</category>
        <category domain="version">2.0.4.0</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<p>This upgrade tool version contains the new XDi platform 2.0.0.2 software.</p>
<p>It will automatically upgrade XDi platform v.2.0.0.0 or 2.0.0.1 units to platform v.2.0.0.2 when a library v.2xxx is installed.</p>
<p>This version can also upgrade platform software v2.0.0.0 &amp; 2.0.0.1 to 2.0.0.2 without uploading the indicator library part again.</p>
<p>This means that the already made indicator selection and parameter setup will not be deleted or changed. After the update, the previously selected virtual indicator will start and work as before.</p>
<p>Upgrade from platform v.1xx.x to 2.0.0.2 will automatically happen when needed and downgrade to a previous platform 1 library is still possible</p>
<p>&nbsp;</p>
<p>Version 2.0.4.0 based on version 2.0.3.0</p>
<ul>
<li>Support for new platform 2 SW version 2.0.0.4</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi Upgrade Tool &#x2013; v3.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-&#x5347;&#x7EA7;&#x5DE5;&#x5177;&#x5305;/3-0-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9a915f61-742c-4b35-ab7c-93a59d17b2f9</guid>
        <pubDate>2025-08-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi Upgrade Tool</category>
        <category domain="version">3.0.0.0</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<h4>Version 3.0.0.0 based on version 2.0.4.0</h4>
<h3>Features:</h3>
<ul>
<li>Added support for ICM 100.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Updated desktop icon.&nbsp;</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>XDi Upgrade Tool &#x2013; v3.0.0.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xdi-&#x5347;&#x7EA7;&#x5DE5;&#x5177;&#x5305;/3-0-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c46ae056-6746-4b8b-b2cd-d278374bba1e</guid>
        <pubDate>2026-01-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XDi Upgrade Tool</category>
        <category domain="version">3.0.0.1</category>
          <category domain="release-status">current</category>
          <category domain="product">XDi</category>
        <content:encoded><![CDATA[
<h4>Version 3.0.0.1 based on version 3.0.0.0</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed timeout issue during installation of large XDi libraries.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>XL/BW CANOpen EDS-file &#x2013; v1.00.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/xl-bw-canopen-eds-&#x8F6F;&#x4EF6;&#x5305;/1-00-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5774946a-99d3-4a0c-99aa-75baecfd0ae0</guid>
        <pubDate>2005-06-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">XL/BW CANOpen EDS-file</category>
        <category domain="version">1.00.0</category>
          <category domain="release-status">current</category>
          <category domain="product">BRW-2 &amp; BW</category>
          <category domain="product">XL</category>
        <content:encoded><![CDATA[
<p>Initial version</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.3.9.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-3-9-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">be542f38-c242-43ca-9d6f-fa9e81fc64d1</guid>
        <pubDate>2022-02-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.3.9.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Only show measurements supported by the connected ECU.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue with writing alarm settings for parameters</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.3.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-3-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2777caff-dcfe-40d8-9a7b-eabb2740f9b3</guid>
        <pubDate>2022-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.3.10.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Custom logo and topbar branding.</li>
<li>Custom branding configuration import/export.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue with negative values in alarm and event log.</li>
<li>Fixed issue with controller communication lost for 1-2 sec every 13 or 25 minutes.</li>
<li>Fixed issue with TDU not able to connect to AGC-4 mkII Mains unit.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.3.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-3-10-1-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">18e8d99d-36b9-4499-bec1-a82f853dd57e</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.3.10.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<p>1- Fixed horizontal scrolling of Supervision.<br />2- Fixed missing "None" option in "Instrument Selection".<br />3- Fixed missing Custom Logo in "Log" and "Controller settings" pages.<br />4- Reset index when changing between "Controller settings" lists.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.3.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-3-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e42d14e3-3003-4980-ba6b-ce4473236d68</guid>
        <pubDate>2023-03-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.3.11.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for FPT stage V engines.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Created separate pages for "Engine lamps" and "Exhaust aftertreatment".</li>
<li>Added support for tree view translations.</li>
<li>Made opening parameters more intuitive.</li>
<li>Added limits to the meters in TDU 110 and TDU 115.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.3.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-3-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">616fa9c9-9857-44b5-abf5-3ca67ed9ec63</guid>
        <pubDate>2023-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.3.11.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Fixed missing application supervision when there is a BTB controller in the application drawing.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.3.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-3-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cfc905cf-b47f-4040-acc8-e802c259d59f</guid>
        <pubDate>2023-08-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.3.12.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>Supervision shows ASC controllers.</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>Added support for Volvo EMS.</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>Fixed TDU 107 supervision issue.</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f0a9d458-d5e1-44b4-bf40-9ed952f6a5f6</guid>
        <pubDate>2023-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.0.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>
<ul>Supervision variant for TDU.</ul>
</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>
<ul>Extended capability to read more VTA's.</ul>
</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II v6.08.0.</ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II BTB.</ul>
</ul>
</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">58aef084-5f02-41e2-bd45-dea636a95892</guid>
        <pubDate>2024-01-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.1.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Support for ASC-150</li>
<li>Support for ASC-4</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed misalignment of busbar in supervision when switching between large and small view.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dbe239e1-3cd8-4853-bb19-aff99679e548</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.2.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<p>&nbsp; &nbsp;1- Confirm action pop-ups.</p>
<p>&nbsp;</p>
<h3>Changes</h3>
<p>&nbsp; &nbsp;1- New method for handling translations.<br>&nbsp; &nbsp;2- Tier 4 jump improvements.</p>
<p>&nbsp;</p>
<h3>Corrections</h3>
<p>&nbsp; &nbsp;1- Fixed issue with parameter dialogue not showing the correct state of the toggle switches.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.2.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ef3ff544-c410-41ff-905d-d1f64eb19048</guid>
        <pubDate>2024-10-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.2.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue with home page application drawing becoming zoomed out with every power cycle or reboot from TDU restart.</li>
<li>Fixed issue with TDU not connecting with AGC-4 Mk II application software version 6.14.0.</li>
<li>Fixed show/hide of page 2-3 in home.</li>
<li>Resolved issue with inhibit start button, inhibit stop button, inhibit GB/TB button and inhibit MB button commands.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7b36be9c-ccc2-4e79-b76d-8e4d210aa896</guid>
        <pubDate>2024-12-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.3.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Added support for two additional nominal settings buttons.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed communication issues with AGC v6.15.x.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e04c1adb-24ea-457c-bf64-f78f4d3547b2</guid>
        <pubDate>2025-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.3.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>This minor update fixes an issue where the TDU is not drawing the application drawing correctly when using BTBs.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">770a16d7-6e0c-4fbe-b569-24158dcf9a2c</guid>
        <pubDate>2025-03-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.4.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Version 1.4.4.0 based on 1.4.3.1</p>
<h3>Changes</h3>
<ul>
<li>OEM branding via Product ID.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4ea3fbe9-6961-4ba5-96db-3bd1c51c15f8</guid>
        <pubDate>2025-04-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.5.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h4>Version 1.4.5.0 based on 1.4.4.0</h4>
<h3>New features</h3>
<ul>
<li>Asset commands on supervision page.</li>
<li>Total plant overview.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Show start/stop buttons as grey when in Auto mode.</li>
<li>Improved readability of plant supervision screen.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>&nbsp; Added missing EIC measurements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 115 Extended &#x2013; v1.4.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-115-&#x6269;&#x5C55;&#x7248;/1-4-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f6c38db8-efa0-44ea-b165-794c3c9ca76c</guid>
        <pubDate>2025-10-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 115 Extended</category>
        <category domain="version">1.4.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added commands to toggle between AUTO and MANUAL/SEMI-AUTO modes from the supervision control panel dialogue.</li>
<li>Enhanced generator data display on the plant screen.</li>
</ul>
<h3>Bug fixes and improvements</h3>
<ul>
<li>Improved Auto logout/Clear user level after block mode selection.</li>
<li>Resolved issue where the TDU did not show the correct text for certain SPN/FMI values.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.3.9.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-3-9-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6f6172e9-b53c-41e7-b6d8-5c9cc7deea99</guid>
        <pubDate>2022-02-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.3.9.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Only show measurements supported by the connected ECU.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue with writing alarm settings for parameters</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.3.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-3-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5d064111-2061-40d0-83f7-f74b3e6a7541</guid>
        <pubDate>2022-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.3.10.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes:</h3>
<ul>
<li>Custom logo and topbar branding.</li>
<li>Custom branding configuration import/export.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue with negative values in alarm and event log.</li>
<li>Fixed issue with controller communication lost for 1-2 sec every 13 or 25 minutes.</li>
<li>Fixed issue with TDU not able to connect to AGC-4 mkII Mains unit.ettings for parameters</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.3.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-3-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">29fa51f9-736f-4b24-b8e7-71246d55230d</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.3.10.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections:</h3>
<p>1- Fixed horizontal scrolling of Supervision.<br />2- Fixed missing "None" option in "Instrument Selection".<br />3- Fixed missing Custom Logo in "Log" and "Controller settings" pages.<br />4- Reset index when changing between "Controller settings" lists.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.3.11.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-3-11-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0917f941-b496-444d-a60a-909eb3c153a7</guid>
        <pubDate>2023-03-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.3.11.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for FPT stage V engines.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Created separate pages for "Engine lamps" and "Exhaust aftertreatment".</li>
<li>Added support for tree view translations.</li>
<li>Made the opening parameters more intuitive.</li>
<li>Added limits to the meters in TDU 110 and TDU 115.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.3.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-3-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2600730e-2c71-42e9-a921-76e5790a1db1</guid>
        <pubDate>2023-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.3.11.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<p>   • Fixed missing application supervision when there is a BTB controller in the application drawing.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.3.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-3-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">95b10fb7-034a-4693-8ecb-5afadf6a602e</guid>
        <pubDate>2023-08-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.3.12.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>Updated supervision to show solar and storage controllers.</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>Added support for Volvo EMS.</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>Fixed TDU 107 supervision issue.</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a2aad83b-c922-4a3a-b951-1da9a6601a43</guid>
        <pubDate>2023-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.0.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>
<ul>
<ul>Supervision variant for TDU.</ul>
</ul>
</li>
</ul>
<h3>Changes</h3>
<ul>
<li>
<ul>
<ul>Extended capability to read more VTA's.</ul>
</ul>
</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>
<ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II v6.08.0.</ul>
<ul>Fixed issue with TDU not being able to connect to AGC-4 Mk II BTB.</ul>
</ul>
</li>
</ul>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">df7604fc-7825-4abd-a157-a707fdbbdb05</guid>
        <pubDate>2024-01-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.1.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Support for ASC-150.</li>
<li>Support for ASC-4</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed misalignment of busbar in supervision when switching between large and small view.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.2.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3ce8b986-c49b-43aa-ab7f-0e0329907872</guid>
        <pubDate>2024-10-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.2.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue with home page application drawing becoming zoomed out with every power cycle or reboot from TDU restart.</li>
<li>Fixed issue with TDU not connecting with AGC-4 Mk II application software version 6.14.0.</li>
<li>Fixed show/hide of page 2-3 in home.</li>
<li>Resolved issue with inhibit start button, inhibit stop button, inhibit GB/TB button and inhibit MB button commands.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c634e282-4e12-4863-9dc2-a671c1de8806</guid>
        <pubDate>2024-12-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.3.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Added support for two additional nominal settings buttons.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed communication issues with AGC v6.15.x.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.3.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-3-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">354f7ab5-a347-4530-bf77-122fffeebe26</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.3.1</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>This minor update fixes an issue where the TDU is not drawing the application drawing correctly when using BTBs</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10826474-4ae5-4ffc-bc93-e23eedb528e3</guid>
        <pubDate>2025-03-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.4.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<p>Version 1.4.4.0 based on 1.4.3.1</p>
<h3>Changes</h3>
<ul>
<li>OEM branding via Product ID.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cbbf3587-fe70-45ca-a4d2-71b4e4423db2</guid>
        <pubDate>2025-04-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.5.0</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h4>Version 1.4.5.0 based on 1.4.4.0</h4>
<h3>New features</h3>
<ul>
<li>Asset commands on supervision page.</li>
<li>Total plant overview.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Show start/stop buttons as grey when in Auto mode.</li>
<li>Improved readability of plant supervision screen.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>&nbsp; &nbsp;Added missing EIC measurements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>TDU 110 Extended &#x2013; v1.4.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/tdu-110-&#x6269;&#x5C55;&#x7248;/1-4-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c60698bc-123b-445d-aab9-8ed8657ffae4</guid>
        <pubDate>2025-10-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">TDU 110 Extended</category>
        <category domain="version">1.4.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">TDU series</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added commands to toggle between AUTO and MANUAL/SEMI-AUTO modes from the supervision control panel dialogue.</li>
<li>Enhanced generator data display on the plant screen.</li>
</ul>
<h3>Bug fixes and improvements</h3>
<ul>
<li>Improved Auto logout/Clear user level after block mode selection.</li>
<li>Resolved issue where the TDU did not show the correct text for certain SPN/FMI values.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-tsp/1-3-0-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8a8e5d92-bff3-4bc4-88aa-8e0649da211a</guid>
        <pubDate>2022-02-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.4</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>== 1.3.0.4<br />* Date: 05/11/2021<br />* Codesys v3.5sp15p20<br />* PCM52 OS 3.0.1.0</p>
<p>=== Added<br />Missing IFM51 devdesv versions<br />Missing IFM52 devdesv versions<br />Missing GPM51 devdesv versions</p>
<p><br />=== Fixed<br />Increased log size for CODESYS<br />Fixed DIO6.1 module can not show the DO status #48</p>
<p>== 1.3.0.3<br />* Date: 01/07/2020<br />* Codesys v3.5sp15p20<br />* PCM51 OS 3.0.5.0<br />* PCM52 OS 3.0.1.0</p>
<p>=== Added<br />* Added CmpXml2 to PCM6.1 &amp; PCM5.2<br />* Added xml2 wrapper<br />* Build Pica package and precontainer<br />* Added pure CODESYS compiled library: ModbusRTU v1.0.0.0 to PCM52<br />* Added pure CODESYS compiled library: IFM51_ComDriver v1.0.1.0 to PCM52<br />* Add pure CODESYS compiled library: DEIF_FileIO v1.0.0.0 to PCM52<br />* Added pure CODESYS compiled library: IecTypes v3.5.1.0 to PCM52<br />* Updated pcm52.devdesc.xml to runtime v3.5.15.20</p>
<p>=== Changes<br />* Updated devdesc for IOM34 to fix CP11662.<br />* Updated CmpDifconfig to version 3.5.15.20<br />* No longer build libdifconfig.so.1 as it is in the BSP</p>
<p>=== Fixed<br />* Fixed https://jira.deif.com/browse/WPBS-31 read_modbus_registers always returns 0 on success</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-tsp/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e89230d-966f-44fd-81ca-81ba10d9bb88</guid>
        <pubDate>2023-05-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-tsp/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">87c08357-5dd4-416a-971d-5c0b976f3caf</guid>
        <pubDate>2023-08-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.8</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 PCM6.1 software bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-pcm61-&#x8F6F;&#x4EF6;&#x5305;/1010/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">44c2b17e-8e6a-4447-9095-c29cc1e17597</guid>
        <pubDate>2022-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 PCM6.1 software bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Changed:</h3>
<p>Updated libmodbus to 3.1.6<br />Openssl updated to version 1.1.1k<br />Linux SDK changed to 64-bit native (x86_64).<br />The load caused by selftest-appfs reduced, allowing use together with other<br />selftests without sacrificing reliability.</p>
<p> </p>
<h3>Fixed:</h3>
<p>Default priority for IRQ threads set to 50 as in upstream linux.<br />Webinterface: CODESYS webvisu detection failed after change to https.<br />https supports more secure methods with openssl 1.1.1k<br />Memory free information in webinterface and rest api to include buffers and<br />cached memory, which makes more sense to application developers.<br />False positive in ate-loopback-ecat-io test.<br />Update ethercatio to v1.1.4.1</p>
<p>Fixed mutex handling when using UART with IFM5.1 and IFM6.1</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 PCM6.1 software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-pcm61-&#x8F6F;&#x4EF6;&#x5305;/1020/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fd1ff6f3-9802-4e89-a596-3dd2bbe194a2</guid>
        <pubDate>2023-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 PCM6.1 software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Fixed:</h3>
<p>- OE-Lite updated to continue to build as GitHub no longer accepts http. This also causes changes to some of the package versions.<br />- Default priority for IRQ threads set to 50 as in upstream Linux.<br />- Web interface: CODESYS webvisu detection failed after change to https.<br />- https supports more secure methods with openssl 1.1.1k.<br />- Memory free information in web interface and REST API now includes buffers and cached memory.<br />- False positive in ate-loopback-ecat-io test.<br />- Updated ethercatio to v1.1.4.1.<br />- Fixed mutex handling when using UART with IFM5.1 and IFM6.1.</p>
<p> </p>
<h3>Added:</h3>
<p>- Added gdb to the controller.<br />- Added backup/restore feature to web interface.<br />- nginx currently not configured and not started by default. Beware that applications may leave persistent config in /app/nginx.<br />- Added HID and HIDRAW configuration to the kernel, which are need for CODESYS Key (USB dongle).<br />- Added dedicated worker thread to solve low latency.<br />- Added `appmode` support to get the current status.</p>
<p> </p>
<h3>Changed:</h3>
<p>- Updated libmodbus to 3.1.6.<br />- Openssl updated to version 1.1.1k.<br />- Linux SDK changed to 64-bit native (x86_64).<br />- The load caused by selftest-appfs reduced, which means you can use it together with other selftests without sacrificing reliability.<br />- An empty /data/sysconf/ethercat file can be used to prevent EtherCAT master operation.<br />- SCP protocol support in OpenSSH removed. Users will have to use SFTP protocol instead.<br />- The vsftpd server will only be started automatically if configured with custom /data/sysconf/vsftpd.conf file.</p>
<p> </p>
<h3>Security:</h3>
<p>- Update of Vue.js and jQuery components to fix various security issues.<br />- Update of OpenSSH to fix various security issues, including CVE-2020-14145.<br />- Update of OpenSSL to fix various security issues, including CVE-2022-0778.<br />- Update of lighttpd to fix various security issues, including CVE-2008-0983, CVE-2018-19052 and CVE-2019-11072.<br />- Update of busybox to fix various security issues.<br />- Lighttpd configuration changed to set X-Frame-Options HTTP header to protect against "clickjacking" attacks.<br />- Lighttpd configuration changed to set X-Content-Type-Options HTTP header to protect against MIME-sniffing on the response body.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 IFM6.1 firmware bundle &#x2013; v1.0.1.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-ifm61-&#x8F6F;&#x4EF6;&#x5305;/1013/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fc696892-ee08-4f3f-9f50-ff33d2e25376</guid>
        <pubDate>2022-05-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 IFM6.1 firmware bundle</category>
        <category domain="version">1.0.1.3</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Added:</h3>
<p>- Intellectual property verification<br />- Diagnosis messages in ESI xml for improved diagnostic</p>
<h3>Changed:</h3>
<p>- uart_scif: Clear FIFO on break, overrun and if threshold reached</p>
<h3>Fixed:</h3>
<p>- Wrong read-out of actual bias/termination setting<br />- Potential buffer overflow in debug message in FDL layer<br />- uart_scif: Ensure FIFO is below threshold before clearing FIFO full flag (BOR-239)</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 IFM6.1 firmware bundle &#x2013; v1.1.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-ifm61-&#x8F6F;&#x4EF6;&#x5305;/1-1-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">75886d2d-bb0f-42f1-9d04-5681271762bc</guid>
        <pubDate>2022-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 IFM6.1 firmware bundle</category>
        <category domain="version">1.1.0.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Added:</h3>
<p>- Added support for up to 10 DP slaves for each master.<br />- Bumped EtherCAT revision to 9.</p>
<h3>Changed:</h3>
<p>- PDOs for first four DP slaves allow exchange of 96 bytes. Remaining DP slaves are restricted to 42 bytes. Full flexibility can still be achieved via custom ESI xml.<br />- Removed PDOs from offline dictionary in ESI xml.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp/1-3-0-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4bda7443-ce0f-46de-9433-85e7c1df7c5e</guid>
        <pubDate>2022-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.4</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p>Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP15 Patch 20) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2ec6683c-e6c1-4e83-8be8-8656aefbdefc</guid>
        <pubDate>2023-05-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP15 Patch 20)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP15 Patch 20) for PCM6.1 &#x2013; v1.3.0.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time/1-3-0-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">257f724b-96d5-4146-8e49-051ea9b9b83e</guid>
        <pubDate>2022-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP15 Patch 20) for PCM6.1</category>
        <category domain="version">1.3.0.4</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM6.1 board</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p>Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP15 Patch 20) for PCM6.1 &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time/1-3-07/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b490958b-8da3-42a2-812e-a1f6e298e045</guid>
        <pubDate>2023-04-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP15 Patch 20) for PCM6.1</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM6.1 board</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP15 Patch 20) for PCM6.1 &#x2013; v1.3.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dd64bdd3-77cb-45f5-bd27-d3d9f44b5bf9</guid>
        <pubDate>2023-08-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP15 Patch 20) for PCM6.1</category>
        <category domain="version">1.3.0.8</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM6.1 board</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2 &#x2013; v1.3.0.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-run-time/1-3-0-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fc64ff2f-1296-4ab4-bc4b-9f521e81b37d</guid>
        <pubDate>2022-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2</category>
        <category domain="version">1.3.0.4</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM5.2 board</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p>Initial release.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2 &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-run-time/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b8b203c7-510d-4459-8cf5-6cc1a6b885b4</guid>
        <pubDate>2023-04-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM5.2 board</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Changes</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS runtime v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2 &#x2013; v1.3.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-run-time/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9eef3109-1b39-4aea-8a1d-e19c8c07e3b8</guid>
        <pubDate>2023-08-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS run-time (SP15 Patch 20) for PCM5.2</category>
        <category domain="version">1.3.0.8</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.15.20</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-ver-1xx/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fcaf083e-1b15-41c8-b157-2c24f0d54406</guid>
        <pubDate>2022-09-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x.</category>
        <category domain="version">1.0.20.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPC 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3><strong>GPC 300</strong></h3>
<p>First release</p>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. &#x2013; v1.0.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-ver-1xx/1-0-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">edee00fb-35bc-46c1-be01-6b647194888c</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x.</category>
        <category domain="version">1.0.21.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPC 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.19.0</strong></p>
<h3><strong>GPC 300</strong></h3>
<h3>New feature:</h3>
<ul>
<li>Added support for multiple applications with a parameter to select active application and custom plant name. (Not supported by PICUS.)</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue where I/O parameter configuration was passed on from one external breaker or a heavy consumer on the single line to another when during commissioning. I/O configuration and parameters are not reset.</li>
<li>Fixed issue where manual regulation didn't work in emulation. </li>
<li>Fixed issue where analogue regulation was unstable in emulation.</li>
<li>Fixed issue with GAM3.2 not working in emulation.</li>
<li>Fixed issue with incorrect regulator mode when a single genset (GB only) connected to mains.</li>
<li>Actual Power total in % is now showing on DU-300 (Live data) and in PICUS.</li>
<li>Fixed issue with external voltage offset in load sharing not working.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. &#x2013; v1.0.23.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-ver-1xx/1-0-23-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b6e0460c-f770-463d-bf3e-6c63b8a54aa4</guid>
        <pubDate>2023-03-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x.</category>
        <category domain="version">1.0.23.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPC 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.20.0</strong></p>
<h3><strong>GPC 300</strong></h3>
<h3>New feature:</h3>
<ul>
<li>New variant that has a mains with mains breaker and tie breaker.</li>
<li>Added emulation for single gensets.</li>
<li>Added the possibility to read dynamic section status in CODESYS.</li>
<li>Added PMS power measurement data.</li>
</ul>
<h3>Changes:</h3>
<ul>
<li>Changed the maximum value for breaker open failure delay to 60 seconds.</li>
<li>Changed the maximum value for breaker close failure delay to 60 seconds.</li>
<li>Added PMS power measurement data.</li>
<li>Selection of "Phase-Phase" / "Phase-Neutral" on selected voltage protections are always shown.</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Emulation now works with fixed power, while mains is exporting (negative kW values on mains).</li>
<li>Breaker operation counter now increments correctly in emulation.</li>
<li>Fixed issue with no tags shown in HMI for AC setup parameter.</li>
<li>Improved backup percentage count in PICUS.</li>
<li>Missing texts have been added.</li>
<li>It is now possible to access the DM2 log from PICUS.</li>
<li>Fixed missing IOM3.4 support.</li>
<li>Analogue AVR now works in emulation.</li>
<li>Fixed an issue with external breaker feature in emulation.</li>
<li>Fixed an issue with using the stop command from switchboard in emulation. This would not stop the engine when running in parallel.</li>
<li>Mains variants have regulator control available in emulation.</li>
<li>Close failure can now be emulated.</li>
<li>The response time for the trip breaker output can exceed 100ms if the configuration has been done in a particular order and the controller has not been power cycled.</li>
<li>Fixed issue where there could be Hz on the generator measurements in emulation when the engine was stopped.</li>
<li>Fixed issue with MPU wire break. It is now working.</li>
<li>Fixed issue where the states in emulation were preserved when emulation was not enabled.</li>
</ul>
<h3>DU 300</h3>
<h3>New features:</h3>
<ul>
<li>Introduces a new view for exhaust after-treatment dashboard increasing the support of Tier 4 and Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. &#x2013; v1.0.27.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-ver-1xx/1-0-23-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">97b59f1e-4dcd-43a5-817a-b0cb53469fee</guid>
        <pubDate>2024-02-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x.</category>
        <category domain="version">1.0.27.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPC 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.20.0</strong></p>
<h3><strong>GPC 300</strong></h3>
<h3>New feature:</h3>
<div style="padding-left: 40px;">• Two new alarms added:</div>
<div style="padding-left: 80px;"><span> 1) "DEIF network has only one connection"</span></div>
<div style="padding-left: 80px;">    Default: enabled, Auto ack, No latch (all configurable)</div>
<div style="padding-left: 80px;">    Action: Warning (hidden)</div>
<div style="padding-left: 80px;">    Menu location: Communication-&gt;DEIF network-&gt;</div>
<div style="padding-left: 80px;">   </div>
<div style="padding-left: 80px;">       Will trigger when going from 2 to 1 connection are detected.</div>
<div style="padding-left: 80px;">    - Zero connections is valid for a stand-alone setup.</div>
<div style="padding-left: 80px;">    - Zero connections will trigger missing all controllers in a system setup.</div>
<div style="padding-left: 80px;"></div>
<div style="padding-left: 80px;"><span> 2) "DEIF network fork detected"</span></div>
<div style="padding-left: 80px;">    Default: enabled, Auto ack, No latch (all editable)</div>
<div style="padding-left: 80px;">    Action: Warning (hidden)</div>
<div style="padding-left: 80px;">    Menu location: Communication-&gt;DEIF network-&gt;</div>
<div style="padding-left: 80px;">    Will trigger when 3 or more connections are detected.</div>
<div style="padding-left: 80px;"></div>
<h3>Corrections:</h3>
<p style="padding-left: 40px;">• Fixed issue where the ROCOF set point and triggered value were not shown on the alarm page (DU300 and PICUS).<br />• Fixed issue where "Data loss on DEIF network" would incorrectly trigger at start-up.<br />• Fixed issue where a redundancy supervision alarm did not trigger when external network equipment was used. <br />• Increased number of missing controller alarms shown.<br />• Fixed issue with controller crashing doing backup. <br />• Fixed issue where a controller performed an unwanted restart due to rare issue in Modbus.<br />• Fixed issue where reading IO status on Modbus could cause unwanted restart of the application software.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. &#x2013; v1.0.28.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-ver-1xx/1-0-28-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">608270ad-36db-49d8-ac39-0d3e88569fcf</guid>
        <pubDate>2024-10-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x.</category>
        <category domain="version">1.0.28.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>Multi-line 300, GPC 300</li>
<li>Bundled with DU 300 SW version 1.0.20.0</li>
</ul>
<p>Minimum required version of PICUS: <strong>1.0.20.0</strong></p>
<h3><strong>GPC 300</strong></h3>
<h3>New features:</h3>
<ul>
<li>EIC: Added support of Cummins CM 570 Industrial.</li>
<li>EIC: Added support of Cummins CM 2350 Industrial.</li>
<li>EIC: Added support of Cummins CM 2880 Industrial.</li>
<li>EIC: Added support of Cummins Generic Industrial.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. &#x2013; v1.0.28.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-ver-1xx/1-0-28-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d2599188-84e6-4f88-8146-9ff94276f886</guid>
        <pubDate>2026-03-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x.</category>
        <category domain="version">1.0.28.2</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h4>1.0.28.2 based on 1.0.28.0</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed the EtherCAT® configuration handling to prevent unsafe behaviour.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.20.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-1xx-codesys-libraries/1-0-20-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e7831d70-d6ac-4079-987d-fc1d5e40c43a</guid>
        <pubDate>2022-09-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.20.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for GPC 300 v. 1.0.20.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.21.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-1xx-codesys-libraries/1-0-21-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5beffd94-51b6-4339-b0f9-e3c05b1980d1</guid>
        <pubDate>2022-10-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.21.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for GPC 300 v. 1.0.21.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.23.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-1xx-codesys-libraries/1-0-23-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">03d55f21-4f98-4667-af01-0e5c627c22a4</guid>
        <pubDate>2023-03-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.23.0</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for GPC 300 v. 1.0.23.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries &#x2013; v1.0.27.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/multi-line-300-gpc-300-1xx-codesys-libraries/1-0-23-0-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">eba46bca-19b0-45c6-97f9-41eaa2c816cd</guid>
        <pubDate>2024-02-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">Multi-line 300 GPC 300 ver. 1.x.x. CODESYS libraries</category>
          <category domain="software-type">CODESYS development tools</category>
        <category domain="version">1.0.27.0</category>
          <category domain="release-status">current</category>
          <category domain="product">GPC 300</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for GPC 300 v. 1.0.27.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 IFM6.2 firmware bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-ifm62-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f076020b-665f-4c52-b0de-674c0c2258e2</guid>
        <pubDate>2022-10-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 IFM6.2 firmware bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Added:</h3>
<p>- Intellectual property verification.<br />- Diagnostic messages in ESI xml for improved diagnostic.</p>
<h3>Fixed:</h3>
<p>- Bug that prevented bootloader from writing SII data to EEPROM.<br />- Removed incorrectly added PDO excludes from ESI XML.</p>
<h3>Changed:</h3>
<p>- Updated SDK.<br />- Moved CAN status PDOs to follow CAN profile spec (also required by CAN Mini Driver).<br />- Moved FREQ and SSI PDOs to avoid conflicts with CAN PDOs.<br />- Bumped EtherCAT revision to version 5.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.0.2.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-0-2-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">66633367-dd74-4f76-a917-b7c87703e195</guid>
        <pubDate>2023-01-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.0.2.2</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>Initial release:</h3>
<p><em>This software applies to the following DEIF products:</em></p>
<ul>
<li><em>SGC 1xx and SGC 4xx series</em></li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.0.2.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-0-2-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">91fa3ed8-f5f7-485d-aef7-b4272accece2</guid>
        <pubDate>2023-07-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.0.2.3</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>Change:</h3>
<ul>
<li>SGC xxx Mk II Hardware is supported.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.0.3.6</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-0-3-6/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1fc57364-5326-49b8-b119-4fbc9ce65050</guid>
        <pubDate>2023-09-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.0.3.6</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>New feature</h3>
<p>• Added support for SGC Mk ll hardware.</p>
<p> </p>
<h3>Changes</h3>
<p>• Improved regional PC setting handling.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.0.3.17</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-0-3-17/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2b3868c5-5c51-4da7-84df-265521a4fd6d</guid>
        <pubDate>2023-12-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.0.3.17</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>New feature</h3>
<p>• Supports Offline Firmware Flash. Firmware for SGC will have a *.sed extension.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.0.4.4</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-0-4-4/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">99aa25a4-6830-4251-980b-87dc868175ba</guid>
        <pubDate>2024-10-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.0.4.4</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<ul>
<li>Added support of flashing of firmware in Live Mode.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>The Max size limit of the exe EEPROM that will flashed has been increased from 128KB to 256KB.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.0.5.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-0-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">86e5cf16-4a09-4b73-b406-ad3bfa587933</guid>
        <pubDate>2025-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.0.5.0</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for SGC 120 Mk ll Lite.</li>
<li>Added support for SGC 420 Mk ll Lite.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Flash &#x2013; v4.1.0.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-flash/4-1-0-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">87e6c3bb-ae7c-4937-aa38-65ca219c03e6</guid>
        <pubDate>2025-03-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Flash</category>
        <category domain="version">4.1.0.3</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 110</category>
          <category domain="product">SGC 120</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 121</category>
          <category domain="product">SGC 410</category>
          <category domain="product">SGC 410 Mk II</category>
          <category domain="product">SGC 420</category>
          <category domain="product">SGC 420 Mk II</category>
          <category domain="product">SGC 421</category>
          <category domain="product">SGC 421 Mk II</category>
        <content:encoded><![CDATA[
<h3>Compatibility with:</h3>
<ul>
<li>SGC 120 R17.00 and below.</li>
<li>SGC 120 R17.00 Lite and below.</li>
<li>SGC 420 R17.00 and below.</li>
<li>SGC 420 R17.00 Lite and below.</li>
<li>RDC 100 R1.00.</li>
</ul>
<p>Smart Flash is renamed to Smart Flash Next.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 PCM5.2 software bundle (CODESYS SP15 Patch 20) &#x2013; v3.0.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-pcm52-software-bundle/3060/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0e6662e4-82b3-4542-96fe-bd9f5f5102c2</guid>
        <pubDate>2023-01-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 PCM5.2 software bundle (CODESYS SP15 Patch 20)</category>
        <category domain="version">3.0.6.0</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<h3>Fixed:</h3>
<p>- https supports more secure methods with openssl 1.1.1k.<br />- Web interface: CODESYS webvisu detection failed after change to https.<br />- Memory free information in web interface and REST API now includes buffers and cached memory.<br />- Updated ethercatio to v1.1.4.1.<br />- Fixed mutex handling when using UART with IFM5.1 and IFM6.1.<br />- OE-Lite updated to continue to build as github no longer accepts http. This also causes changes to some of the package versions.</p>
<h3>Added:</h3>
<p>- Added gdb to the controller.<br />- Added backup/restore feature to web interface.<br />- nginx currently not configured and not started by default. Beware that applications may leave persistent config in /app/nginx.<br />- Added HID and HIDRAW configuration to the kernel, which are need for CODESYS Key (USB dongle).<br />- Added dedicated worker thread to solve low latency.<br />- Added `appmode` support to get the current status.</p>
<h3>Changed:</h3>
<p>- Openssl updated to version 1.1.1k.<br />- Added Windows SDK again since it contains tools for bootstrapping use in production.<br />- An empty /data/sysconf/ethercat file can be used to prevent EtherCAT master operation.<br />- SCP protocol support in OpenSSH removed. Users will have to use SFTP protocol instead.<br />- The vsftpd server will only be started automatically if configured with custom /data/sysconf/vsftpd.conf file.</p>
<h3>Security:</h3>
<p>- Updated Vue.js and jQuery components to fix various security issues.<br />- Updated OpenSSH to fix various security issues, including CVE-2020-14145.<br />- Updated OpenSSL to fix various security issues, including CVE-2022-0778.<br />- Updated lighttpd to fix various security issues, including CVE-2008-0983, CVE-2018-19052 and CVE-2019-11072.<br />- Updated busybox to fix various security issues.<br />- Lighttpd configuration changed to set X-Frame-Options HTTP header to protect against "clickjacking" attacks.<br />- Lighttpd configuration changed to set X-Content-Type-Options HTTP header to protect against MIME-sniffing on the response body.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 PCM5.2 software bundle (CODESYS SP15 Patch 20) &#x2013; v3.0.7.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-pcm52-software-bundle/3-0-7-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ee8ea6f0-7758-4b91-90e4-3ac22434b09f</guid>
        <pubDate>2025-04-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 PCM5.2 software bundle (CODESYS SP15 Patch 20)</category>
        <category domain="version">3.0.7.1</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>This release contains minor corrections and changes.</p>
<h3>Corrections</h3>
<ul>
<li>Bug causing link loss on EoE interfaces after EtherCAT rescan.</li>
<li>Fixed module list on the web interface.</li>
<li>Fixed selection of the time zone "(GMT-08:00) Pacific Time (US &amp; Canada)" in the web interface.</li>
<li>Problem with logc tail -f not showing new log lines.</li>
<li>Bug causing logc cat to fail with "too many open files" fail, and consequently also web interface syslog.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated to bingbang v1.0.2.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP18 Patch 40) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp18-patch-40/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1d36d3be-8b50-43e1-9426-38de9f227011</guid>
        <pubDate>2023-05-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP18 Patch 40)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP18 Patch 40) &#x2013; v1.3.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp18-patch-40/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5b76401e-755f-49ac-9be2-283dc5e8e1c3</guid>
        <pubDate>2023-07-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP18 Patch 40)</category>
        <category domain="version">1.3.0.8</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP18 Patch 40) &#x2013; v1.3.0.9</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp18-patch-40/1-3-0-9/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">15062233-a9d8-40ec-b816-5bca2cff3733</guid>
        <pubDate>2023-10-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP18 Patch 40)</category>
        <category domain="version">1.3.0.9</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p><strong>New features</strong><br />• Added iE BSP component.</p>
<p><strong>Changes</strong><br />• Updated TIM61 devdesc to v1.0.1.1, revision 4.<br />• Updated AIO61 devdesc to v1.0.1.1, revision 4.<br />• Updated DIM61 devdesc to v1.0.0.0, revision 2.<br />• Updated DOM61 devdesc to v1.0.0.0, revision 3.<br />• Updated DIO61 devdesc to v1.0.1.0, revision 2.<br />• Updated DIO62 devdesc to v1.0.0.0, revision 2.</p>
<p> </p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP18 Patch 40) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp18-patch-40/1-3-07/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e7e47506-b32e-409e-8b5d-9e6888b27956</guid>
        <pubDate>2023-04-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP18 Patch 40)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM6.1 board</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP18 Patch 40) &#x2013; v1.3.0.9</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp18-patch-40/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9ef9fe69-a40c-47a4-8f50-0fe4d8308a15</guid>
        <pubDate>2023-07-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP18 Patch 40)</category>
        <category domain="version">1.3.0.9</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM6.1 board</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP18 Patch 40) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp-sp18-patch-40/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e76e3feb-6bdf-43e5-ba16-7677aad23930</guid>
        <pubDate>2023-06-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP18 Patch 40)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS TSP (SP18 Patch 40) &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-tsp-sp18-patch40/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">295bcc1c-79e6-4db9-8d6a-9aeb14a105b5</guid>
        <pubDate>2023-06-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS TSP (SP18 Patch 40)</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Updates</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS run-time v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU Slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS TSP (SP18 Patch 40) &#x2013; v1.3.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-tsp-sp18-patch40/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">671e1e7e-8190-4f4a-a906-c07b1408ade9</guid>
        <pubDate>2023-07-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS TSP (SP18 Patch 40)</category>
        <category domain="version">1.3.0.8</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p>&nbsp;</p>
<p><strong>Added</strong></p>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p>&nbsp;</p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS run-time (SP18 Patch 40) for PCM5.2 &#x2013; v1.3.0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-run-time-sp18-patch-40/1-3-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dbc26269-8f22-4627-93ba-1da74600fed6</guid>
        <pubDate>2023-06-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS run-time (SP18 Patch 40) for PCM5.2</category>
        <category domain="version">1.3.0.7</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM5.2 board</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Changes</strong></p>
<p>• Open62541 upgraded to v1.3.4.</p>
<p> </p>
<p><strong>New features</strong></p>
<p>• CODESYS runtime v3.5.18.40.<br />• Added support for CODESYS OPC UA Client SL.<br />• Added support for CODESYS OPC UA Server SL.<br />• Added support for CODESYS RTU Master.<br />• Added support for CODESYS RTU slave.</p>
<p> </p>
<p><strong>Corrections</strong></p>
<p>• Fixed unresolved references in CmpFFT library.<br />• Deprecated DEIF_FileIO.compiled-library.<br />• Updated libModbus to v1.1.0.5, and removed dependency on CODESYS standard library.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS run-time (SP18 Patch 40) for PCM5.2 &#x2013; v1.3.0.8</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-run-time-sp18-patch-40/1-3-0-8/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c09f938f-f93d-4f32-8ffc-cf11956c796d</guid>
        <pubDate>2023-07-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS run-time (SP18 Patch 40) for PCM5.2</category>
        <category domain="version">1.3.0.8</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>Run-time software for CODESYS on a PCM5.2 board</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p> </p>
<p><strong>Added</strong></p>
<ul>
<li>- CODESYS OPC UA Server (SP18 and newer)</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1</li>
<li>Fix scan/copy all devices SIM6.2</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.1.0.44</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-1-0-44/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3a4c587e-37c2-4b1e-96ef-ef627c22d67c</guid>
        <pubDate>2023-09-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.1.0.44</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<p>DEIF Smart Connect Software for SGC 1xx / 4xx Mk II</p>
<p>• Initial release.<br />• Supports SGC 120 Mk ll R12.0.<br />• Supports SGC 420 Mk ll R12.0 &amp; R13.0.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.1.3.5</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-1-3-55/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">195949f6-9350-4c84-bf90-14b734bd8e93</guid>
        <pubDate>2023-12-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.1.3.5</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<p>DEIF Smart Connect Software for SGC 1xx / 4xx Mk II</p>
<p>• Supports SGC 120 Mk ll R12, R13 &amp; R14.<br />• Supports SGC 420 Mk ll R12, R13 &amp; R14.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.1.4.18</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-1-4-18/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e2972c5d-0a29-42f1-8231-88177608c87d</guid>
        <pubDate>2024-02-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.1.4.18</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<p>DEIF Smart Connect Software for SGC 1xx / 4xx Mk II<br />• Supports SGC 120 Mk ll R12 to R14.<br />• Supports SGC 420 Mk ll R12 to R15.</p>
<p>New features<br />• Support for SGC 420 Mk ll R15.0.<br />• Added digital input summary.<br />• Added digital output summary.<br />• Added analog input summary.<br />• Updated translations.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.2.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-2-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a316c298-5510-4a6a-95e0-8e33e8e3d4a8</guid>
        <pubDate>2024-04-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.2.0.0</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<p><strong>DEIF Smart Connect Software for SGC 1xx / 4xx Mk II</strong><br>• Supports SGC 120 Mk ll R12 to R15.<br>• Supports SGC 420 Mk ll R12 to R15.</p>
<p><strong>New features</strong><br>• Compatibility of SGC 120 R15.00 added.<br>• Validation of interlocks.<br>• Summary table for digital input, output and analogue input added.<br>• Reading the event log in live mode added.<br>• Reading and writing of M-Logic in live mode added.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.2.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-2-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dbc4f43a-6c23-480b-8fb1-e7028f660b8f</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.2.1.0</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<p><strong>DEIF Smart Connect Software for SGC 1xx / 4xx Mk II</strong><br>• Supports SGC 120 Mk ll R12 to R15.<br>• Supports SGC 420 Mk ll R12 to R16.</p>
<p><strong>New Features</strong> &nbsp; &nbsp;<br>• Language: Added support for Romanian in Smart Connect.<br>• Language: Added support for Spanish in Smart Connect &amp; Controller Display.</p>
<p><strong>Changes</strong><br>• On and OFF Delay for M-Logic Range updated to 0-600 seconds.<br>• LOP sensor range changed from 0-10 to 0-99.<br>• Custom sensor Name editable from engine Module.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.4.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-4-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">00888d96-39eb-4fc9-bd48-5dc55674e63f</guid>
        <pubDate>2024-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.4.0.0</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>DEIF Smart Connect Software for SGC 1xx / 4xx Mk II</h3>
<ul>
<li>Supports SGC 120 Mk ll R12 to R16.</li>
<li>Supports SGC 420 Mk ll R12 to R16.</li>
<li>Supports SGC 120 Mk ll Lite R16.</li>
<li>Supports SGC 420 Mk ll Lite R16.</li>
</ul>
<h3>New Features</h3>
<ul>
<li>Added Custom Sensor for SGC 120 Mk ll.</li>
<li>Added Portuguese translation for SGC 120 Mk ll.</li>
<li>Added Spanish &nbsp;translation for SGC 120 Mk ll.</li>
<li>Added support for Russian Hebrew, Ukrainian, Turkish texts for SGC 120 Mk ll &amp; 420 Mk ll.</li>
<li>Added support for SGC 120 Mk ll Lite &amp; SGC 420 Mk ll Lite.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated range of LOP sensor from (0-10) to (0-99) for SGC 120 Mk ll &amp; 420 Mk ll.</li>
<li>Updated On and OFF Delay of M-logic to (0-600 sec) for SGC 120 Mk ll &amp; 420 Mk ll.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.5.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-5-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1b11188d-9d1b-4396-943e-710882602ba7</guid>
        <pubDate>2025-02-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.5.0.0</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>DTC Manager: added as a tool providing options to update SPN and FMI descriptions and ignore specific SPN/FMI codes.</li>
<li>Display enhancements: added the ability to display customer details on the boot up screen through the display language tool.</li>
<li>Remote display functionality: added live link for enhanced remote display capabilities.</li>
<li>Digital inputs: added "Shutdown override" function.</li>
<li>Maintenance module: added "Shutdown" as an alarm action.</li>
<li>Custom sensors: added activation and delay timers.</li>
<li>Manual mode: added auto load transfer as a separate parameter for mains.</li>
<li>External EGR support: enabled via digital input.</li>
<li>File information: added provision for relevant screens.</li>
<li>AC system: introduced an alternate nominal AC system.</li>
</ul>
<h3>Supported versions:</h3>
<p>- SGC 120 Mk II: R12 to R16.01.<br>- SGC 420 Mk II: R12 to R17.00.<br>- SGC 120 Mk II Lite: R16.00.<br>- SGC 420 Mk II Lite: R17.00.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v1.5.2.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/1-5-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">97016a34-ee21-4773-ba7e-207e7bdd0ada</guid>
        <pubDate>2025-03-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">1.5.2.1</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>Smart Connect Mk II</h3>
<p>Compatibility with:</p>
<ul>
<li>SGC 120 R17.00 and below.</li>
<li>SGC 120 R17.00 Lite and below.</li>
<li>SGC 420 R17.00 and below.</li>
<li>SGC 420 R17.00 Lite and below.</li>
<li>RDC 100 R1.00.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v2.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/2-0-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8989f482-f4d7-46e5-a528-8f9beef7d2aa</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">2.0.0.0</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added secure password to enhance access control and user safety</li>
<li>Added German language</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Improved accuracy for fuel tank</li>
<li>Updated overload range to ensure better protection and system reliability</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v2.1.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/2-1-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e3ebcaa1-a340-410d-9461-59dbf189f406</guid>
        <pubDate>2025-12-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">2.1.1.0</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for Italian language.</li>
<li>Added support for Turkish language.</li>
<li>Added support for password management.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Aligned mute functionality with SGC 420 Mk II.</li>
<li>Aligned fuel tank capacity with SGC 420 Mk II.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Smart Connect Mk II &#x2013; v2.1.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-smart-connect-mk-ii/2-1-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">aac07a28-c1f8-4ca2-a005-caaaca778d4b</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Smart Connect Mk II</category>
        <category domain="version">2.1.3.0</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Compatible with SGC 420 R19.00</li>
<li>Added end-user licence agreement added.</li>
<li>Added support for the Italian language.</li>
<li>Added Connect button as part of password management.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>The stop-action timer range has been extended.</li>
</ul>
<h3>Improvements</h3>
<ul>
<li>Improved support for the Turkish language.</li>
<li>Updated warning and shutdown return/trip interlocks to allow finer threshold differentiation and improved system accuracy.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware - version 1.3.x &#x2013; v1.3.797</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-firmware-version-13x/1-3-797/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8451a0ba-2043-420c-b5de-dbb637c6836e</guid>
        <pubDate>2023-09-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware - version 1.3.x</category>
        <category domain="version">1.3.797</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p><strong>New features</strong><br />• Added FRAM Backup / Restore support (1.3.786).<br />• Added watchdog during early boot sequence (1.3.762).<br />• Added SSH client to configOS image (1.3.741).<br />• UN6x: Added support for RTSP and MJPEG video streams (1.3.721). <br />• Added SUMMARY field to license.manifest file (1.3.654).<br />• Added device compatibility code (1.3.503). <br />• Backlight timeout is set to 15 minutes (1.3.075). <br />• Added custom font management to system settings (1.3.054).</p>
<p><br /><strong>Corrections</strong><br />• Updating bridge settings will not overwrite the settings that are currently enabled (1.3.797).<br />• FRAM Manage Target handling (1.3.786).<br />• Nginx might not be ready when system settings are accessed locally (1.3.750). <br />• Fixed SW restart issue with a specific 8 GB eMMC (1.3.737).<br />• Fixed race condition when starting DHCP server on boot (1.3.737).<br />• Fixed issue with data partition update from local files (1.3.737).<br />• Web management interface does not work if data partition is full (1.3.737). <br />• NTP time adjustments not preserved after restore and updates (1.3.717). <br />• Issues with entering password in authentication window (1.3.698).<br />• Watchdog might trigger during a BSP update (1.3.667).<br />• Failure to pull up Ethernet if router service is started at the same time (1.3.654). <br />• Fixed issue with using VNC with encryption enabled (1.3.652).</p>
<p><strong>Security</strong><br />• Cyber security: Idle session timeout for VNC server (1.3.632). <br />• libtiff CVE-2022-0561 and CVE-2022-0562 (1.3.611). <br />• XSS Protection and HTML/JS validation (1.3.606).<br />• Implemented loading custom VNC server certificate (1.3.572).<br />• Implemented CORS access control (1.3.569).<br />• Added minimum requirements for VNC password (1.3.563).<br />• Added system domain to store application secrets (1.3.553).<br />• Added new web server service to system settings with new security options (1.3.553).<br />• Added support of TLS 1.3 and drop 1.1 in web server (1.3.555).<br />• Added user passwords to restore functionality in system settings (1.3.532). <br />• System settings functionality and API to recall secrets (1.3.512). <br />• Enforce the principle of least privilege (1.3.497). <br />• Added support to clear data partition without removing applications (1.3.346). <br />• Users are forced to change password at first login (1.3.079).<br />• openssl CVE-2022-1292 (1.3.687).</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware - version 1.3.x &#x2013; v1.3.836</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-firmware-version-13x/1-3-836/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">62b425dd-f900-4497-9741-30df728d5675</guid>
        <pubDate>2024-05-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware - version 1.3.x</category>
        <category domain="version">1.3.836</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p>Upgrade from 1.3.797 to 1.3.836 to keep in sync with M variants.</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407 - 410 Firmware - version 1.3.x &#x2013; v3.1.421</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-407-410-firmware-version-13x/3-1-421/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a07336a6-c69b-41df-9fa0-9a833717d70b</guid>
        <pubDate>2024-11-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407 - 410 Firmware - version 1.3.x</category>
        <category domain="version">3.1.421</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Auditable events.</li>
<li>Session lock.</li>
<li>Authorisation enforcement for all users + role mappings.</li>
<li>Identification and authentication of users.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where application package failed to install if zip archive was created under Windows.</li>
<li>Fixed issue where interfaces were not always reachable after reconfiguring network.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.3.x &#x2013; v1.3.797</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-firmware-version-13x/1-3-797/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">83d93c5e-f243-48bf-af0b-7b51d4e939cf</guid>
        <pubDate>2023-09-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.3.x</category>
        <category domain="version">1.3.797</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p><strong>New features</strong><br>• Added FRAM Backup / Restore support (1.3.786).<br>• Added watchdog during early boot sequence (1.3.762).<br>• Added SSH client to configOS image (1.3.741).<br>• UN6x: Added support for RTSP and MJPEG video streams (1.3.721). <br>• Added SUMMARY field to license.manifest file (1.3.654).<br>• Added device compatibility code (1.3.503). <br>• Backlight timeout is set to 15 minutes (1.3.075). <br>• Added custom font management to system settings (1.3.054).</p>
<p><br><strong>Corrections</strong><br>• Updating bridge settings will not overwrite the settings that are currently enabled (1.3.797).<br>• FRAM Manage Target handling (1.3.786).<br>• Nginx might not be ready when system settings are accessed locally (1.3.750). <br>• Fixed SW restart issue with a specific 8 GB eMMC (1.3.737).<br>• Fixed race condition when starting DHCP server on boot (1.3.737).<br>• Fixed issue with data partition update from local files (1.3.737).<br>• Web management interface does not work if data partition is full (1.3.737). <br>• NTP time adjustments not preserved after restore and updates (1.3.717). <br>• Issues with entering password in authentication window (1.3.698).<br>• Watchdog might trigger during a BSP update (1.3.667).<br>• Failure to pull up Ethernet if router service is started at the same time (1.3.654). <br>• Fixed issue with using VNC with encryption enabled (1.3.652).</p>
<p><strong>Security</strong><br>• Cyber security: Idle session timeout for VNC server (1.3.632). <br>• libtiff CVE-2022-0561 and CVE-2022-0562 (1.3.611). <br>• XSS Protection and HTML/JS validation (1.3.606).<br>• Implemented loading custom VNC server certificate (1.3.572).<br>• Implemented CORS access control (1.3.569).<br>• Added minimum requirements for VNC password (1.3.563).<br>• Added system domain to store application secrets (1.3.553).<br>• Added new web server service to system settings with new security options (1.3.553).<br>• Added support of TLS 1.3 and drop 1.1 in web server (1.3.555).<br>• Added user passwords to restore functionality in system settings (1.3.532). <br>• System settings functionality and API to recall secrets (1.3.512). <br>• Enforce the principle of least privilege (1.3.497). <br>• Added support to clear data partition without removing applications (1.3.346). <br>• Users are forced to change password at first login (1.3.079).<br>• openssl CVE-2022-1292 (1.3.687).</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.3.x &#x2013; v1.3.836</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-firmware-version-13x/1-3-836/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">28dcea6a-046a-4beb-b6d2-7edc291cd6dc</guid>
        <pubDate>2024-07-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.3.x</category>
        <category domain="version">1.3.836</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p>Upgrade from 1.3.797 to 1.3.836 to keep in sync with M variants.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 415 - 421 Firmware - version 1.3.x &#x2013; v3.1.421</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-415-421-firmware-version-13x/3-1-421/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ae400260-7677-456b-b189-c968e02999cc</guid>
        <pubDate>2024-11-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 415 - 421 Firmware - version 1.3.x</category>
        <category domain="version">3.1.421</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Auditable events.</li>
<li>Session lock.</li>
<li>Authorisation enforcement for all users + role mappings.</li>
<li>Identification and authentication of users.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where application package failed to install if zip archive was created under Windows.</li>
<li>Fixed issue where interfaces were not always reachable after reconfiguring network.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 400 SW Pack for BSP ver. 1.3 or above &#x2013; v4.5.0.518</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-300400-sw-pack-for-bsp-ver-13/4-5-0-518/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">067b7f88-c5ef-48a4-ab17-635948d503bb</guid>
        <pubDate>2023-09-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 400 SW Pack for BSP ver. 1.3 or above</category>
        <category domain="version">4.5.0.518</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<ul>
<li>
<p><strong>New features</strong></p>
<p>                      Alarms</p>
<ul>
<li>Add Date Format property in action DumpEventArchive</li>
<li>Add Touch Ack Notify sent only when the Ack is performed locally by the HMI</li>
</ul>
<p> </p>
<p>                      CODESYS v3.0</p>
<ul>
<li>Updated CODESYS to version 3.5 SP16</li>
</ul>
<p> </p>
<p>                      Gallery</p>
<ul>
<li>Review and improve widget gallery</li>
</ul>
<p> </p>
<p>                      Generic</p>
<ul>
<li>Add to project properties a flag to allow users to disable any type of popup controlled by runtime</li>
</ul>
<p> </p>
<p>                      Javascript</p>
<ul>
<li>Added JS profiling in Runtime developer tools for deep diagnosis</li>
<li>Dialog size can be changed from JavaScript up to 1920x1080 resolution</li>
<li>Added API for Load project / Last visited project actions</li>
</ul>
<p> </p>
<p>                      MQTT</p>
<ul>
<li>Added Tag interface to MQTT</li>
<li>Improved management of MQTT CA Certificate file</li>
<li>MQTT: Improve the accuracy of currentTimestamp to ms</li>
</ul>
<p> </p>
<p>                      Multilanguage</p>
<ul>
<li>Possibility to associate a keypad to current language</li>
</ul>
<p> </p>
<p>                      Protocols</p>
<ul>
<li>Added dictionary file synchronization on tag for most used protocols</li>
<li>[J193] Manage J1939 generic alarms</li>
<li>[J193] add doCommand to send DM1 alarms from HMI</li>
<li>[CDS3] Remove "full node address" option</li>
<li>[MODS] Node disable management for Server protocols</li>
<li>[MODR] Node Override for Modbus TCP Server with possibility to disable node</li>
<li>[J193] extend protocol with UDS diagnostic commands</li>
<li>[MRTU] Add support for array elements direct access in Modbus RTU</li>
<li>[MRTU] Reduced protocol communication gap</li>
</ul>
<p> </p>
<p>                      Recipes</p>
<ul>
<li>Added warning message when restore recipe fails due to not supported chars</li>
</ul>
<p> </p>
<p>                      Remote</p>
<ul>
<li>Clients Reduce the load time in client cache</li>
<li>Clients Client Cache Improvement</li>
</ul>
<p> </p>
<p>                      Simulator</p>
<ul>
<li>Added tool in Simulator to watch and simulate project tags</li>
<li>Added Online Simulator tool</li>
</ul>
<p> </p>
<p>                      Tags</p>
<ul>
<li>Possibility to display better view for indexed tags sets in case of long name tags</li>
<li>Add "replace" button for "Invalid Tag Reference"</li>
<li>Import/Export/Copy/Paste for Indexed Tag sets</li>
<li>Tag editor improvement, add double click selection for properties</li>
<li>Added Client system variable to support remote variable scenarios</li>
<li>Possibility to choose widget objects from Index Tag parameter in Indexed Tags</li>
<li>Importer default selection should follow also the combo-box selection of protocols</li>
<li>Add tag name info in read block and read datagram error in protocol error message</li>
<li>Manage tag values with offline simulator</li>
</ul>
<p> </p>
<p>                      Trends</p>
<ul>
<li>Added Up and Down button in Trend Data log to reorder Tags to be sampled</li>
<li>Sampling Time datalink is available only if we have more than one tag to log</li>
<li>Add Minimum interval Time to 100 ms in trend sample when it used a Trigger Tag</li>
<li>Trend buffer import/export, clone and autofill</li>
<li>Add "Attach to" option for FileName properties of DumpTrend</li>
</ul>
<p> </p>
<p>                      User</p>
<ul>
<li>Interface Automatic offsets for retentive variables</li>
<li>Interface Added System Settings button in Manage Target</li>
<li>Interface Change Project Type option on right click of Device node in project tree</li>
<li>Interface Added possibility to choose project upload folder and quick click to open an uploaded project</li>
<li>Interface Added Online help</li>
</ul>
<p> </p>
<p>                      Widgets</p>
<ul>
<li>Web: Table widget sorting support</li>
<li>New scatter chart widget</li>
<li>Enhanced combo box widget style capabilities</li>
<li>Added continuous index option in combo box widget</li>
<li>Enhanced Web browser widget capabilities</li>
<li>Add MJPEG Camera URL between the basic properties of IP Camera Widget</li>
<li>Added Dashboard pages</li>
<li>Added Tag bar widget</li>
<li>Added Stack widget to manage layers</li>
<li>Added new icons in widget gallery</li>
<li>Added QR code widget</li>
<li>Web Browser widget: Add save cookie and Accept-Language support</li>
<li>Provided way to load legacy widget gallery</li>
<li>Common alignments settings for all text/numeric widgets</li>
<li>Added historic and real time trend chart widgets</li>
<li>Added user gallery configurator for icon, display text and tooltip</li>
<li>Optimized layer widget communication management to activate only active layer</li>
</ul>
<p> </p>
<p><strong>Corrections</strong></p>
<p>                      Alarms</p>
<ul>
<li>Alarm import file filter not effective when AGI Creator runs in French language</li>
<li>Live Tag of Multi size array generate an invalid Tag reference</li>
<li>Corrected behavior of alarms connected to array elements</li>
</ul>
<p> </p>
<p>                      Audit</p>
<ul>
<li>Trail Warning message appears at every Logout after Date&amp;Time change</li>
</ul>
<p> </p>
<p>                      Behavior</p>
<ul>
<li>Corrected behavior of HMI Client application in boot sequence</li>
<li>Initial change password not working with Client</li>
<li>Corrected performances issue when loading page with Tables</li>
<li>Page with dot in them name could not been load</li>
<li>Corrected behavior of HMI Client on login</li>
<li>Deleted false error detected by project validator on recipe widget</li>
<li>Error sending email with attachment in specific SMTP server</li>
<li>Corrected behavior on property pane which closes after specific sequence</li>
<li>Wrong page numbering on Studio tabs on specific page sequence creation</li>
<li>Actions defined on hold key pressure are not executed</li>
<li>Improved tag selection in specific sequence from Tag Editor</li>
<li>Corrected Runtime behavior when downloading a specific CODESYS V2 project</li>
<li>In runtime, all web files are stored in main project folder and not inside web folder</li>
<li>BACnet scheduler can't read weekly boolean tag and crash with PLCtrend</li>
<li>Corrected behavior of specific project causing disconnection from HMI client</li>
<li>Corrected behavior on specific project tun on Simulator</li>
<li>Corrected AGI Creator behavior when cutting some tags in tag editor</li>
<li>Aligned differences in rendering on the HMI device or in the web using a large amount of data</li>
<li>Corrected AGI Creator behavior in project conversion if project is not saved as but renamed</li>
<li>Corrected data entry behavior on scaled numeric field linked to recipe selected set</li>
<li>Corrected Demo License internal PLC behavior</li>
<li>Opening an external application while holding button causes button to remain pressed</li>
<li>CODESYS does not recognize project inside panel with additional module</li>
<li>Corrected false positive error on loading images at project opening</li>
<li>Corrected unexpected behavior of runtime using specific project</li>
<li>JavaScript Editor increases the distance between two consecutive rows of code under specific scenarios</li>
<li>Corrected hierarchical importers behavior</li>
<li>Corrected USB update behavior in specific conditions</li>
<li>Corrected behavior when DBWrite Action are executed and Fast Boot is enabled</li>
<li>Corrected runtime behavior on print action with specific project</li>
<li>Fixed behavior while setting protocols with plc network and specific steps</li>
<li>CODESYS 3.5 SP14 runtime not communicating with protocol on WCE</li>
<li>Corrected behavior on second project download for specific hardware</li>
<li>Fixed runtime behavior on loading a specific project</li>
<li>Corrected behavior when executing Print Graphic Report action</li>
<li>Action “File &gt; Save Project As” doesn’t show the path of the current opened project</li>
<li>Corrected behavior when User Gallery folder is changed</li>
<li>Corrected behavior when multiple page change is performed in a specific condition</li>
<li>Corrected sporadic behavior when downloading project</li>
</ul>
<p> </p>
<p>                      CODESYS v3.0</p>
<ul>
<li>Corrected CODESYS license activation behavior</li>
</ul>
<p> </p>
<p>                      Generic</p>
<ul>
<li>Corrected disk size value displayed in project wizard for some models</li>
</ul>
<p> </p>
<p>                      Javascript</p>
<ul>
<li>Corrected action execution on JavascriptFuncBlock on project level</li>
</ul>
<p> </p>
<p>                      MQTT</p>
<ul>
<li>MQTT timestamp is published differently for Will/Birth message and for Data Pub message</li>
<li>MQTT Interface when we open the Manage push policies, the default policy changes to OnChange</li>
<li>MQTT AlarmGroup keyword is always the same at runtime</li>
<li>MQTT TLS version is inherited from Generic Broker configuration</li>
<li>Connection to Amazon AWS not working, bad character in if_mqtt.xml file</li>
<li>MQTT: Value received does not update the tag if tagName keyword is not present in topic</li>
<li>MQTT with multiple tags in payload published wrongly when on timer is Used</li>
<li>Corrected MQTT connection behavior with Google IoT Core broker</li>
<li>Corrected MQTT behavior when using TLS without certificates</li>
<li>MQTT: Runtime HMI cannot publish to Amazon AWS Broker due to plugin missing</li>
</ul>
<p> </p>
<p>                      Protocols</p>
<ul>
<li>[MODS] Corrected serial data exchange in WCE targets</li>
<li>[MODR] Adjusted behavior on node 0 inserting, to be applied only for UDP connections</li>
<li>[BACN] max segments accepted error if device doesn't handle segments</li>
<li>[OPCU] Data type imported as null</li>
<li>[CDS3] Device loses connection with CODESYS Workbench under certain conditions</li>
<li>[J193] Announcement message does not respect 50ms timing interval on DM1 multipacket</li>
<li>[MODR] Tags defined in Modbus TCP Server has inappropriate ID in Tag URL</li>
<li>[J193] Corrected with fastboot enabled and DM1 message present on bus</li>
<li>[PROD] Communication is not established after a cable disconnection</li>
<li>[MODR] Server does not answer in TCP mode with Node ID 0</li>
</ul>
<p> </p>
<p>                      Recipes</p>
<ul>
<li>Corrected behavior when recipe download is executed on string tags</li>
<li>Corrected behavior when recipe download is executed on string with special chars</li>
<li>Recipe Field displays wrong data on screen</li>
<li>Writing more char in string recipe elements following elements is overwritten</li>
<li>Runtime executes more and redundant writes when a Tag array is used in Recipe</li>
</ul>
<p> </p>
<p>                      Scheduler</p>
<ul>
<li>Sunrise and Sunset wrong hour during summer time</li>
</ul>
<p> </p>
<p>                      Tags</p>
<ul>
<li>Tag editor Scaling problems when entering scaling factors with decimal point</li>
<li>Scaled array with fixed point does not write value properly</li>
<li>AGI Creator does not save Interfaces tag group selection</li>
<li>Indexed tags fields are not updated and shows question marks</li>
</ul>
<p> </p>
<p>                      Trends</p>
<ul>
<li>[BACN] Corrected Simulator behavior using BACNetTrends</li>
<li>Corrected PLC Trend behavior in showing curves</li>
</ul>
<p> </p>
<p>                      Widgets</p>
<ul>
<li>TextTableFilter widget apply filter "0" when field is empty</li>
<li>Trend table duration not working properly when we set 4 weeks / ALL</li>
<li>Network configuration is not applied when the interface is with an AutoIP</li>
<li>Browser widget scrollbars does not work</li>
<li>Corrected AGI Creator behavior on continuous index flag of combobox widget</li>
<li>ComboBox doesn't show communication error icon and show wrong element with index data</li>
<li>Fixed behavior of IC Camera widget image polling</li>
<li>Reviewed minor icon graphic in new widget gallery</li>
<li>Text Editor widget save file without extension and does not recognize them in browse</li>
<li>System keypad not opening during save procedure with text editor</li>
<li>Table Data Source requires tag of the model even when the page is changed (or dialog is closed)</li>
<li>(Custom) Corrected visualization issues on a custom alarm table</li>
<li>(Custom) Boolean BACnet scheduler does not work properly</li>
</ul>
<p> </p>
<p><strong>Security</strong></p>
<ul>
<li>Login after Change Password in Login Page does keep the Permission of the User Logged before</li>
<li>User forced to change initial password after editing another user credentials</li>
<li>Group home page changed when changing FTP/HTTP settings</li>
<li>Corrected behavior when accessing to USB and SD via FTP on specific hardware</li>
<li>Added FTPS secure communication</li>
<li>Enhanced password hashing method in runtime and AGI Creator</li>
<li>TLS support for JM mailing</li>
<li>Added project signature functionality to allow only certified project to run</li>
<li>Added HTTPS secure communication</li>
<li>Added timeout after wrong password for user login</li>
<li>Added CSRF (Cross-site request forgery) token as project property for web security</li>
<li>Updated openSSL library</li>
<li>Enforced default settings for user management/security</li>
<li>Added project file encryption</li>
<li>Context menu set to “on action” by default to increase security</li>
</ul>
</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 400 SW Pack for BSP ver. 1.3 or above &#x2013; v4.5.2.427</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-300400-sw-pack-for-bsp-ver-13/4-5-2-427/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">18ed757a-5f30-4fed-8b7e-f36ee2ea8242</guid>
        <pubDate>2024-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 400 SW Pack for BSP ver. 1.3 or above</category>
        <category domain="version">4.5.2.427</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added support for the download of the Machine.ini file on the Manage Target Board of AGI Creator.</li>
<li>Added AGI 415 MHB and AGI 405 panel models under DEIF brand.</li>
<li>Import of multilanguage texts in messages should match existing languages.</li>
<li>Added remove support of WCE panels from v4.5.2.x for DEIF AGI.&nbsp;</li>
<li>Added X7/X10 - System Variables (Proximity, Brightness).</li>
<li>Added system variables to support "MicroEDGE" devices</li>
<li>Updated DEIF Brand.</li>
<li>[MIQE] Added "HEXADECIMAL IO" for XML importer</li>
<li>CODESYS 3.5.19.</li>
<li>[S7OP] Added security settings management.</li>
<li>[S7ET][S7OP] Added support for importer Tia Portal project 19.</li>
<li>X7/X10 - System Variables.</li>
<li>[OPCU] Mask password in UI.</li>
<li>[MIQE] AGI Creator can not import new Tag file format generated from GX WORKS 3 v1.081k.</li>
<li>[CDSH] [CDS3] In a AGI Creator project, Tags are imported without comment.</li>
<li>JM4Web: Improved naming of image files.</li>
<li>Added option to enable fastboot only in AGI Creator ( with project settings).</li>
<li>Added panel models - AGI 407M and AGI 410M.</li>
<li>[PROD] Made Device ID, Sync and Freeze Profibus options, user configurable.</li>
<li>[S7PP] 187k baud rate allowed.</li>
<li>Added eX710MG as HMI model.</li>
<li>JM4Web - added support for Tab widgets.</li>
<li>[OPCUA Server] Added Multilanguages Support for Alarm properties that support it.</li>
<li>Added offline version of the help.</li>
<li>[PA#782] Verify OSS in 4.05.01.</li>
<li>[JM4Web] Added property "Line Style" to Line widget.</li>
<li>FRAM Backup / Restore from USB updater, system settings and Manage Target in AGI Creator.</li>
<li>A default behaviour can now be chosen when opening an application created with previous JM.&nbsp;</li>
<li>[S7ET][S7OP] Added support for importer Tia Portal project 18.</li>
<li>Made PLCM10 variables available in CODESYS.</li>
<li>Added review of alphabet and numeric keypads style.</li>
<li>Added System Variables on PLCM10 for SIM PIN and credentials in case of PAP connection and APN.</li>
<li>CODESYS PN-Device Stack.</li>
<li>Added panel models - AGI 415M and AGI 421M.</li>
<li>Added review if UM templates style.</li>
<li>The web browser widget will not highlight when the HTTPS site does not have a trusted certificate.</li>
<li>[JM4Web] Added support to change EditBox widget Frame colour.</li>
<li>Added support to change EditBox widget Frame colour.</li>
<li>Upload User Modified data when uploading application.</li>
<li>Added property "Style" to Line widget.</li>
<li>[J193] Added new features for Diagnostic frames (DM1 DM2 DM3 DM4).</li>
<li>Added feedback usability of Stack Widget.</li>
<li>[CDSH] Implemented online user security: implemented PLC Handler based protocol.</li>
<li>Added support to RTSP &amp; MJPEG protocol in IP Camera widget.</li>
<li>Enhanced Dashboard User Interface.</li>
<li>Translation: Added AGI Creator Client multi-languages.</li>
<li>Added Studio double check: if a serial port (com) is just in use by an other driver and if a protocol driver supports multi-instance.</li>
<li>Added "Allow HTTPS Only" on Runtime PC.</li>
<li>Studio ML Improvements.</li>
<li>Improved usability of Stack widget.</li>
<li>Provided option to remove the certificate from Runtime PC.</li>
<li>Added create custom widget from a single widget.</li>
<li>Split delete runtime dynamic files into multi options (Trends, Events, Recipes, Scheduler, User Management).</li>
<li>Unicode support for recipes.</li>
<li>Added PDF Viewer option to show the entire page of PDF.</li>
<li>Added ignore added element if Set recipe has been created before addition.</li>
<li>Added Expose Watchdog disable in Project Properties.</li>
<li>Restore Recipe with restore type MatchandAdd will now not work in case of wrong restore file.</li>
<li>[JM4Web] Added Restore Recipe with restore type MatchandAdd will now not work in case of wrong restore file.</li>
</ul>
<h3><br>Corrections</h3>
<ul>
<li>[CDS3] Fixed issue where having another protocol instance disconnected toggle action, took time to be executed.</li>
<li>Fixed device issues in handling Malformed TLS packet on port 990/tcp.</li>
<li>Fixed device issues in handling Malformed FTP packet on ports 21/tcp and 990/tcp.</li>
<li>Fixed issue where Downgrading OS Components were not working from Manage Target (Introduce Issue).</li>
<li>[DSER] Fixed issue with using the Direct Serial protocol for RS232 communication, when the token is longer than 1000 characters the first 1001 characters are discarded - Case ID: 202402787.</li>
<li>[BACN] Fixed issue where the Notification Class Count value caused the HMI to crash.</li>
<li>[BACN][BAC2] Fixed issue of multistate value on BACnet server having wrong default.</li>
<li>[BACN][BAC2] Fixed issue where BACnet max MS/TP APDU cannot be lower than 256.</li>
<li>Fixed issue where action configured on button was not executed under specific conditions.</li>
<li>JM4Web: Fixed issue where SVG stroke line was not visible on web pages.</li>
<li>Fixed issue where using indexed elements of an array as alarms' Ack Notify, they did not behave correctly.</li>
<li>Fixed issue where under a specific condition, the Hot Spot Button did not work properly.</li>
<li>Fixed issue where adding a new alias inside plc network caused rename other plc tags.</li>
<li>JM4Web: Fixed issue where close dialog action did not work properly on web pages.</li>
<li>Fixed issue where MQTT Birth Message appeared twice and a data was missing to publish.</li>
<li>Fixed where downloading of recipe under specific scenario caused runtime crash.</li>
<li>Fixed issue where parameter reference became broken when custom widget was copied between projects.</li>
<li>Fixed issue where curl command sent to panel caused immediate runtime crash.</li>
<li>Fixed issue where runtime crashed when loading historic alarm data.</li>
<li>[J193] Fixed issue where Multipacket stopped being sent.</li>
<li>Fixed issue where offline licence activation procedure did not work if the PC had no internet connection.</li>
<li>Fixed issue where numeric field property "Show Thousand Separator" did not work for specific values.</li>
<li>[CDSH] Fixed issue where in a CODESYS project offline, adding global variables (handler protocols) that were not used in the HMI, and the CODESYS project online was updated, it caused HMI/PLC loss of communication.</li>
<li>[CDSH] Fixed issue where when using the CODESYS handler protocol and the connection to variables is lost, changing pages between pages with stack widgets or data transfer, the connection is lost again - Case ID: 202401802.</li>
<li>JM4Web: Fixed issue where it was tot possible to enter carriage return in Data Entry.</li>
<li>JM4Web: Fixed issue where using a filter in the history alarm widget, and selecting the custom field 1 column did not work.</li>
<li>JM4Web: Fixed issue where message widget with non continuous index,- Live tag was not working correctly.</li>
<li>Duplicate widget inside gallery</li>
<li>[J193] Fixed issue where Protocol was unable able to save the PGN table to BIN file. (regression).</li>
<li>JM4Web: &nbsp;Fixed issue where IP Camera widget behaved differently depending on Web application access if HTTP or HTTPS.</li>
<li>JM4Web: Fixed where Combobox did not work in web pages from mobile device only.</li>
<li>Fixed issue where alarms were listed in active alarms widget even when Notify events were all disabled.</li>
<li>Fixed issue where linking a project widget's property inside a formula did not work.</li>
<li>Fixed issue where using a filter in the history alarm widget and selecting the custom field 1 column did not work.</li>
<li>Corrected wrong result with 64-bit integer operations formulas.</li>
<li>[OPCU] Imported string tags now have correct length.</li>
<li>Fixed issue where Read tag failed on MariaDB (Win32 runtime).</li>
<li>Fixed issue where ftpPUT and ftpGET Javascript functions stopped working from v4.5 onwards.</li>
<li>Fixed issue of crash after Copy/Paste of indexed tags.</li>
<li>Fixed issue where after creating a new user with specific common parameters in runtime, the user disappeared after closing and re-opening the runtime.</li>
<li>Fixed issue where import users did not work from network folder, missing error information.</li>
<li>JM4Web: Needle of new switch and slider widget now works properly with Chrome and Microsoft Edge browser.</li>
<li>[J193][CAND] Fixed issue where when both protocols were used on the same bus, that is in BUSOFF, some RX data problem was detect.</li>
<li>[B193][J193][NM2k][NM20] - Fixed issue where tag sporadically takes random values from protocol.</li>
<li>Fixed issue where encrypting the customer project, the project was not loaded.</li>
<li>JM4Web: Fixed issue where alarm state was not translated in alarm widgets.</li>
<li>Fixed issue where installing, uninstalling and then re-installing XAscender 4.5.1.701 made the uninstall option disappear from the start menu.</li>
<li>[OPCU] Fixed issue where override variables did not work as expected in OPC UA Client.</li>
<li>JM4Web: Fixed issue where alarm history generated a very high number of requests and caused an error in the web visualisation.</li>
<li>Fixed issue where import license did not work as expected.</li>
<li>Fixed issue where it was not possible to reach a PELCO IP camera via IP Stream widget.</li>
<li>System variables now support "eX200 Family" devices.</li>
<li>Wayland: Fixed issue where Authentication dialog automatically closed on Client.</li>
<li>Fixed issue where after minimising the system keyboard in the context menu, it could not open.</li>
<li>Fixed issue of LMX crash in runtime PC in a specific x86 environment (tecnorobot).</li>
<li>JM4Web: Fixed issue where ´multiple live tags in the same alarm did not show the correct values.</li>
<li>Fixed issue where HMI client showed blue question mark on specific button inside stack widget.</li>
<li>Fixed issue where after several hours, JMClient crashed and Server connection was lost.</li>
<li>Enable HIET and HISE protocols for UN78.</li>
<li>Fixed issue where display alarms took too long on first page with Fastboot.</li>
<li>Fixed issue of runtime crash with ISOPAN project.</li>
<li>Fixed issue where stack widget caused slow page loading with tag inside.</li>
<li>Fixed HMI Runtime crash when DB query called from JS and updated in a table in a dialog page.</li>
<li>Fixed issue where stack widget inside customer project caused runtime and simulator crash.</li>
<li>Fixed issue where press and release of button action was executed twice inside stack widget.</li>
<li>Fixed issue where HMI Client crashed on connection to the server.&nbsp;</li>
<li>[MRTU] Fixed issue where offline algorithm did not work with Modbus RTU client.</li>
<li>[J193] Handling PGN with number now extended (that contains Node Address).</li>
<li>JM4Web: Fixed issue where Combo box did not work on mobile browser.</li>
<li>CASE J: Bug 48376: Fixed issue where OPC UA Client -&gt; Connection to the server did not work when DNS hostname validation was selected.</li>
<li>Bug 49008: Fixed issue where HMIStudio allowed two instances of the same project to be in conflict with each other.</li>
<li>CASE H: Bug 48373: Fixed issue where spaces in the path of HMIStudio projects were not supported.</li>
<li>Fixed issue where Import and Save multilanguage texts took a very long time in customer application.</li>
<li>[CDSH] [CDS3] Fixed issue with hierarchical import Tag String as string-0 when length is a constant in CODESYS program.</li>
<li>[MIQE] Fixed issue where Importer could not import Tags by .csv file generated by GX Works 3 with non-English languages.</li>
<li>[CAND] Fixed issue of long frame sending with NMEA2000 Fast protocol.</li>
<li>Fixed issue where OPC UA server export and import incorrectly shows Encoding type as Latin for the data types.&nbsp;</li>
<li>JM4Web: Fixed issue where the trend table widget showed placeholder names in the columns header when no Tag was set.</li>
<li>[NM2K] Fixed various non compliant behaviours.</li>
<li>Fixed issue where Studio froze and crashed when Checkpoint VPN software ran on PC.</li>
<li>Fixed issue where entering the system settings took too long.</li>
<li>Fixed issue of runtime crash with customer project.</li>
<li>Fixed issue where ODBC connection on 64bit runtime (UN78) did not work.</li>
<li>Hotspot button click through behaviour now same in JM 4.5.</li>
<li>Fixed issue where trying to update project with update package caused runtime crash.</li>
<li>[PROD] Fail Safe Mode Profibus options now user configurable.</li>
<li>Fixed issue of error message handling when importing a missing multilingual .xml file.</li>
<li>Fixed issue where Linux devices used RST command to close TCP connection.</li>
<li>[OMRE] Fixed issue where PLC model CP1L did not support write of multiple strings.</li>
<li>Fixed issue where Runtime was shutdown as soon as the application started.</li>
<li>[DSCK] Fixed issue where there was a communication block and panel reboot with customer application.&nbsp;</li>
<li>Can now send message with AWS/MQTT QoS0.</li>
<li>Fixed issue where AWS/MQTT “Retain” function did not work.&nbsp;</li>
<li>Fixed issue where the project may not restart if the restart action was executed while connected to AWS.</li>
<li>Fixed issue where the widget shows question mark with 1 JM Server and 4 JM Client.</li>
<li>[PA#569] Fixed 4.5.1 studio translation issues.</li>
<li>Fixed issue where alarm acknowledge from corvina cloud did not work after runtime restart.</li>
<li>Fixed issue where removing a modified page caused a Studio crash.</li>
<li>[IDE3] Fixed issue where tag import created a wrong URI for M memory type tags.</li>
<li>[J193] Fixed issue where DTC1 in Alarm J1939 was no longer detected after changed version.</li>
<li>[OPCU] Fixed issue where Enum type variables could be read but not written.</li>
<li>JM4Web: Fixed issue where momentary button sometimes remains pressed.</li>
<li>JM4Web: &nbsp;Fixed issue with responsive design where the button labels shifted on clicking in automatic script.</li>
<li>Fixed issue where it was not possible to download to target if manual proxy was set on Windows 10.</li>
<li>[S7OP] Fixed issue where communication error tag name was not found when importing customer TIA portal project.</li>
<li>[PA#569] Fixed issue where same choices were made for existing recipes.</li>
<li>JM4Web: Widget Permission at Page Level now works the same in web project.</li>
<li>[KEKV] Fixed incorrect read of Timer/Counter/Comparator contacts.</li>
<li>AGI: Fixed issue where Creator crashed when a specific project was downloaded.</li>
<li>Fixed issue of slow page loads with newest runtime.</li>
<li>Retentive memory automatic space calculation for array data types now correct.</li>
<li>[CDS3] Fixed issue of delay between datagrams when this protocol was used in TCP mode.</li>
<li>SetSerialMode function of SerialExt library now working.</li>
<li>GetTag on specific array element now working on PC Client.</li>
<li>[KEKV] Fixed issue of wrong access to word variables.</li>
<li>DB Connector now works properly using case-sensitive databases.</li>
<li>[OMRE] Optimized protocol request to maximize data exchange with PLC.</li>
<li>Fixed issue where AGI Creator crashed after deleting Tag mapped in Audit Trail.</li>
<li>Fixed issue where there was a wrong value on PLC when 2500 value (and multiple) written on Numeric Field with scaling and Tag with Swap conversion.</li>
<li>Fixed issue where runtime crashed with Stack widget which contains 5 layers and nested 5 stacks.</li>
<li>Fixed issue of wrong empty line inside "Data Format" Combobox of Regional Settings.</li>
<li>Fixed issue where HMI crashed while printing PDF for first time after project downloaded.</li>
<li>Fixed sporadic issue where OnRelease event on physical keyboard was not executed when changing page.</li>
<li>Combobox now shows correct text when Negative value is present in the index.</li>
<li>Fixed issue where error handling for unsupported writing system choices was not working.</li>
<li>Dialog now in correct position at runtime.</li>
<li>Fixed issues with Audit Trail.</li>
<li>Copy/Paste now working in Tag editor.</li>
<li>Fixed issue where it was possible to log in to client with user group that was not authorised to log in to the client.</li>
<li>Fixed issue where panel reboots following page change sequence.</li>
<li>Fixed issue where combobox visualisation did not work in template page in a specific configuration.</li>
<li>Fixed issue where project was slow after unload and reload operation in case of Data Transfers.</li>
<li>Fixed issue where there were unexpected changes in MD5 checksum after multiple project downloads.</li>
<li>Fixed issue where CTRL+S did not perform "Save All" if active page was Tags or Protocol.</li>
<li>Fixed issue of CODESYS Version 3.5.16.30 distributed in AGI Creator 4.5 with erroneous "set_baud_rts.sh" file.</li>
<li>Fixed issuer where project showed no values and ? in numeric fields after update to 4.5.1.406.</li>
<li>[PA#557/28] - Fixed issue where BSP update may not be possible from AGI Creator's device management.</li>
<li>JM4Web: &nbsp;Fixed issue where word wrap was not working in latest 4.5.1 builds.</li>
<li>JM4Web: Fixed issue where numeric fields alignment was different in Chrome and Chromium.</li>
<li>JM4Web: Fixed issue where table widget did not load.</li>
<li>JM4Web: The correct index value for ML enabled non continuous index &nbsp;message widget in web is now shown.</li>
<li>Fixed issue where runtime on HMI froze if numeric field was pressed simultaneously on Multi touch screen.</li>
<li>TabBarWgt action security will now be erased after modifying configuration.</li>
<li>Fixed issue where Canvas Auto Clear Background did not works on web pages.</li>
<li>JM4Web: Fized issue where screen froze when we performed multiple logins with with specific users.</li>
<li>JM4Web: Fixed issue of different behavior in scatter diagram refresh between panel and web page.</li>
<li>JM4Web: Fixed issue of misalignment between native and web pages on trend cursor value.</li>
<li>Fixed recipe JS Api compatibility issues.</li>
<li>[MIFE] Extended size of data blocks for optimization on word registers. Fixed wrong maximum size on bit registers.&nbsp;</li>
<li>JM4Web: Fixed issue where after conversion to 4.5.1, font type and size were wrong in web pages.</li>
<li>IPLC Codesys V3 - Checked diagnostic function and bits of PLIO03 and PLIO06 board.</li>
<li>Fixed issue where Writing System did not work using JM in Japanese or Chinese language.</li>
<li>[PA#477] - JM4Web: Removed fake messages from the validation report.</li>
<li>Fixed issue where canvas "Draw Hint" property did not work on native project.</li>
<li>Fixed issue where signature was not requested if value was changed by knob or slider.</li>
<li>Fixed issue where AuditTrail Signature did not work if Buttons, Switches or Alias were used for writing the Tag.</li>
<li>Fixed issue where automatically double-clicking on Tag was not acquired with full name if original importing was done with hierarchical mode.</li>
<li>Button Fill colour with formula now working in web browser (JM4Web).</li>
<li>[Jm4Web] - Fixed issue where old Alarm History widget did not show the Custom Fields in the table properly when used in 4.5.</li>
<li>Fixed issue where Japanese (multiByte char) String was not recognized on JS Editor embedded on CW.</li>
<li>Fixed issue where "BrowseMedia" on a small display opened a dialog window that is larger than the display size.</li>
<li>Changed the JP strings coming under toolbar related with Spacing.</li>
<li>Fixed issue where default user groups with no tags R/W permission caused tags to not update.</li>
<li>AGI Creator now recognises "-" character in upload password project when it is defined in the BSP.</li>
<li>Fixed issue where projects launched from links cannot be saved after upload.&nbsp;</li>
<li>Fixed issue where data transfer did not work on Client System variables.</li>
<li>X5 - Added "Number of Connected Station" in System Variable when device is configured like Access Point.</li>
<li>Fixed issue where switch user and logout to default caused stack widget to fail to update tags.</li>
<li>Fixed issue where in custom widget, parameter used as array index would always be treated as 0.</li>
<li>Fixed issue where number format property of numeric field returned to custom value.</li>
<li>Fixed issue where ComboBox listed items were duplicated in the runtime after switching between continuous and non continuous index mode.</li>
<li>Fixed issue where runtime crashed while scrolling alarm, audit or trend table widgets.&nbsp;</li>
<li>[PA#783] Fixed issue where write command was sent many times and other problems.</li>
<li>Fixed issue where multistate image with Continuous Index flag was disabled and default Index values did not work correctly.</li>
<li>Fixed issue where Rename Tag name was not reflected in the table data src widget when it was attached with formula.</li>
<li>[PA#783] Fixed issue where write command was sent many times.</li>
<li>Fixed issue where runtime crashed when´an empty message was published on Retain enabled topic.</li>
<li>Fixed issue where Studio crashed when enabled and added new tag from Dictionary to assign in the Indexed Tag Set.</li>
<li>Fixed issue where Studio crashed if an attempt is made to manually reorder the Alias of Indexed Tag Set.</li>
<li>Fixed issue where runtime crashed after frequent changes of Index Tag (Indexed Tags).</li>
<li>[JM4Web / Runtime] - Fixed number format issues.</li>
<li>Fixed issue where AGI Creator Client application did not store fullscreen option.</li>
<li>[OPCU] Fixed issue where the connection with customer's server was lost periodically.</li>
<li>Qt5 Studio: Fixed issue where unicode char was not handling properly in File dialog and in JP OS, simulation was not working if JP char used in the path.</li>
<li>Fixed issue where labels on Custom Widget replaced special character with "?".</li>
<li>[ETIP] Fixed issue where symbols with parameter "Usage := Public" were not imported from Linear importer.</li>
<li>Fixed issue where tag string was updated twice if value applied was longer than string size.</li>
<li>JM4Web: Colour Palette now works when Old button is pressed.</li>
<li>Label font size now works properly in web page.</li>
<li>Fixed issue where AGI Creator could not retain stored 'admin' password of HMI; Enter Dialog will be always asked before a project download on PC with OS Win10 and Win7.</li>
<li>Fixed issue where using 1/10 s time sampling was not accurate in PC runtime.</li>
<li>Fixed issue where time field format in Dump did not respect Date format in the action in 4.5.&nbsp;</li>
<li>Fixed issue where dynamic set naming for AddRecipeDataSet action did not work in JM4Web.</li>
<li>[MODR] Fixed issue where panel failed to start with AGI Creator+codesys on 4.5.</li>
<li>JM4Web: Fixed issue where Write on Index property of combobox widget did not work with a particular project.</li>
<li>Fixed issue where rename user galley page caused Studio to crash.</li>
<li>Fixed issue where sent email content was not Unicode.</li>
<li>PLCM10/PLCM11/PLC12 / PLCM10B - Common system Variables now used for all variants.</li>
<li>Fixed issue where when GridLayout is in Edit Mode, if the project is downloaded, the GridLayout is shown in Edit Mode at runtime.</li>
<li>JM4Web: Fixed issue where values were not displayed in table widget.</li>
<li>Fixed issue where Boolean BACnet scheduler widget did not correctly show and write default value.</li>
<li>Fixed issue where Canc shortcut from Object View did not work for layers of Stack widget.</li>
<li>Fixed issue where StackWgt crashed when a new layer was added in Studio.</li>
<li>Fixed issue where GNSS State System variables always showed State 0 even when a GPS signal was received.</li>
<li>Fixed issue where computation of Min and Max values were displayed incorrectly on web.</li>
<li>Fixed issue where trial licence did not work as expected in some computers.</li>
<li>Fixed issue where grid layout enabled inside a stack widget layer was not show in full size before reopening page.</li>
<li>Fixed issue where BACnet alarms considered the timestamp of the Alarm as UTC.</li>
<li>Fixed issue where messages and label inside nested Custom Widget were completely lost in 4.5.</li>
<li>Fixed issue with delay in searching runtime in local host when downloading the project for the first time.</li>
<li>[OPCU] Fixed issue where symbols discovery did not work for device connect using Port Forwarding.</li>
<li>Fixed issue of taking too long to display within the browser widget before being resized correctly.</li>
<li>Fixed issue where the GridLayout layer of a StackWgt inside a Custom Widget was not correctly resized.&nbsp;</li>
<li>Fixed crash when page.reject JS command was used in the keyboard.</li>
<li>Fixed issue where add recipe set name did not work with number only or string with dot.</li>
<li>Fixed issue where load page from switch user returned error if page name contained a dot.</li>
<li>Fixed issue where changing the system time on a panel will bug the visualisation of those variables on the browser page.</li>
<li>Fixed issue where recipe import in project or panel did not return any warning if set name was a number.</li>
<li>Fixed issue where Restore Recipe action of Alarm causes Error Message if number of sets are changed.</li>
<li>Fixed issue where runtime crashed when execute RestoreRecipe with BrowseforFile enabled.</li>
<li>Fixed issue where first attempt to connect to Win32 runtime by typing only IP fails.</li>
<li>JM4Web: fixed issue where start time and end time in every widget with page duration did not work as expected.&nbsp;</li>
<li>Fixed issue where it was not possible to print from runtime and simulator (Printer Busy error message returned).</li>
<li>Fixed issue where Widget Security Settings were lost when duplicating a page.</li>
<li>[OPCU] Fixed issue where when using PLC Network and Slave 2 goes offline and online again, communication is not reestablished.</li>
<li>Fixed issues with protocol Alias on tags.</li>
<li>Fixed issue where Client shows blue question mark icons on Tag when page loaded for first time when Client system variable protocol is configured.</li>
<li>Fixed issue where Multilanguage Import of CSV file did not found any file if language was Japanese.</li>
<li>Fixed issue where pinch event was decentralised on PDF Viewer.</li>
<li>Fixed issue of delay when page with Table widget loaded.</li>
<li>Fixed issue where the restore of a new recipe set with a different number of elements, generated an empty set.</li>
<li>Studio Crashed when the Grid Layout background colour of an object is changed into Stack with Grid Layout disabled.</li>
<li>Fixed Issue with negative data entry (CRMTS201301350).</li>
<li>Arrays are now managed properly by MQTT.</li>
</ul>
<h3><br>Security</h3>
<ul>
<li>CVE-2017-18214 - Moment js</li>
<li>CVE-2022-24785 - Moment.js</li>
<li>CVE-2022-39353 - xmldom</li>
<li>CVE-2022-37616 - xmldom</li>
<li>CVE-2019-10744 - lodash</li>
<li>CVE-2020-8203 - lodash</li>
<li>CVE-2021-23337 - lodash</li>
<li>CVE-2018-14404 - Libxml2</li>
<li>CVE-2019-19956 - Libxml2</li>
<li>CVE-2020-25694 - PostgreSQL</li>
<li>CVE-2020-25696 - PostgreSQL</li>
<li>CVE-2021-3518 - Libxml2</li>
<li>CVE-2022-23308 - Libxml2</li>
<li>CVE-2022-40303 - Libxml2</li>
<li>CVE-2022-40304 - Libxml2</li>
<li>CVE-2021-3517 - Libxml2</li>
<li>CVE-2021-43311 - UPX</li>
<li>CVE-2021-43312 - UPX</li>
<li>CVE-2021-43313 - UPX</li>
<li>CVE-2021-43314 - UPX</li>
<li>CVE-2021-43315 - UPX</li>
<li>CVE-2021-43316 - UPX</li>
<li>CVE-2021-43317 - UPX</li>
<li>CVE-2022-42915 - Curl</li>
<li>CVE-2023-23914 - Curl</li>
<li>CVE-2019-9687 - PoDoFo</li>
<li>CVE-2018-19873 - Qt</li>
<li>CVE-2015-1290 - Qt</li>
<li>CVE-2019-10744 - lodash</li>
<li>CVE-2021-22946 - Curl</li>
<li>CVE-2022-22576 - Curl</li>
<li>CVE-2022-27775 - Curl</li>
<li>CVE-2022-27781 - Curl</li>
<li>CVE-2022-27782 - Curl</li>
<li>CVE-2022-42916 - Curl</li>
<li>CVE-2022-43551 - Curl</li>
<li>CVE-2023-27533 - Curl</li>
<li>CVE-2023-27534 - Curl</li>
<li>CVE-2023-28319 - Curl</li>
<li>CVE-2018-12983 - PoDoFo</li>
<li>CVE-2018-19532 - PoDoFo</li>
<li>CVE-2018-20751 - PoDoFo</li>
<li>CVE-2019-9199 - PoDoFo</li>
</ul>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.1 Software bundle &#x2013; v1.0.1.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle/1-0-1-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3507c04f-119b-4457-8352-c759d6ae040c</guid>
        <pubDate>2023-10-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.1 Software bundle</category>
        <category domain="version">1.0.1.1</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><br /><strong>New features</strong><br />• Bootloader updater functionality.<br />• Added Software Quality Plan (SQP). <br />• Readout of DAC status register via SDO 0x60X0.<br />• Updated output SDOs in PDO mapping. <br />• Added support for EtherCAT complete access. <br />• Added diagnosis messages in ESI xml for improved diagnostic.<br />• Added support for analogue input and output -10 V to 10 V.<br />• Added support for analogue input -20 mA to 20 mA.<br />• Bumped EtherCAT revision to version 4.</p>
<p><br /><strong>Changes</strong><br />• Updated platform.<br />• Fixed mask of RDY status bit in ads114s_status_ready.<br />• Updated EBusCurrent in ESI.<br />• Improved firmware upgrade. Rescan when done and not for each IO module.<br />• Changed group name from "I/O Bar modules" to "AMC 600" in ESI file.<br />• Updated vendor and group image in ESI XML.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.1 Software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">22d563d6-1271-449f-ac28-4caf27ad0c20</guid>
        <pubDate>2024-03-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.1 Software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><br /><strong>New features:</strong></p>
<p>- Firmware zip package to release artifacts<br />- Support for AIO6·2 (8 x analogue inputs and outputs)<br />- Support for AOM6·2 (8 x analogue outputs)<br />- PDO support for output status (0x1A00)<br />- Terminal description to user manual<br />- Bump AIO6·1 EtherCAT revision to version 5</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.1 Software bundle &#x2013; v1.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle/1-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">54ae9550-c1c1-41e2-b089-9e8eff9e0b7f</guid>
        <pubDate>2025-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.1 Software bundle</category>
        <category domain="version">1.0.3.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Changed</h3>
<ul>
<li>Improve precision for analog output 4-20mA range</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.1 Software bundle &#x2013; v1.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle/1-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0cda9161-1740-4818-9899-6977727b037f</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.1 Software bundle</category>
        <category domain="version">1.0.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.0.4.0] - 2025-10-02</h4>
<h3>New features</h3>
<ul>
<li>Added support for -12 to 12 V and 0 to 12 V analogue inputs</li>
<li>Added support for 0 to 24 mA analogue inputs and outputs</li>
<li>Added support for 4 to 20 mA NAMUR NE43 analogue inputs</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Prevent polarity shift when voltages below -10 V are applied to 0 to 10 V analogue inputs</li>
<li>Fixed 4 to 20 mA under-range detection with 0.4% margin</li>
<li>Prevent polarity shift from -10 V overflow on analogue outputs</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 TIM6.1 software bundle &#x2013; v1.0.1.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-tim61-software-bundle/1-0-1-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4736c994-6a24-4729-9496-641c36f5ce60</guid>
        <pubDate>2023-10-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 TIM6.1 software bundle</category>
        <category domain="version">1.0.1.1</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><strong>New features</strong><br />• Bootloader updater functionality.<br />• SQP: Software Quality Plan<br />• Added support for EtherCAT complete access.<br />• Added diagnosis messages in ESI xml for improved diagnostic.<br />• Bumped EtherCAT revision to version 4.<br />• Added support for 3-wire Pt100 connections.</p>
<p><br /><strong>Changes</strong><br />• Updated EBusCurrent<br />• Improved firmware upgrade. Rescans when done and not for each IO module.<br />• Changed group name from "I/O Bar modules" to "AMC 600" in ESI file.<br />• Updated vendor and group image in ESI XML.</p>
<p><strong>Corrections</strong><br />• Underrange flag is not set for RTD shortcuts.<br />• Enforces initial read of reference temperature.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 TIM6.1 software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-tim61-software-bundle/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8972986f-74d5-43d3-8e2a-4537a280004e</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 TIM6.1 software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>## [1.0.2.0] - 2026-04-13</h4>
<h3>Changes</h3>
<ul>
<li>Terminal descriptions were added to the User’s manual.</li>
<li>The temperature range was extended to -200 to 590 °C.</li>
<li>The EtherCAT revision was updated to version 5.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Under-range and over-range bits were not always cleared.</li>
<li>Incorrect enum value endianness was corrected in the online EtherCAT interface.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DIM6.1 software bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dim61-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a5bc20c5-a4a5-40bf-99f5-ff06286ed88f</guid>
        <pubDate>2023-12-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DIM6.1 software bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><br /><strong>New features</strong><br />• Firmware zip package to release artifacts.<br />• Added support for DIO6·2 (16 x digital inputs and outputs).<br />• Added support for DIM6·1 (32 x digital inputs).<br />• Added support for DOM6·1 (32 x digital outputs).</p>
<p><br /><strong>Changes</strong><br />• SQP - Software Quality Plan.<br />• Aligned channel names with DIM5·1.<br />• Updated EBusCurrent in ESI.<br />• Changed the file names for the artifacts.<br />• Changed the group name to "AMC 600" in ESI file.<br />• Updated the vendor and group image in ESI XML.<br />• Bumped EtherCAT interface revision to v2.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DOM6.1 software bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dom61-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">14c0eb66-ca5e-4bf8-bcdb-8368f5b599ad</guid>
        <pubDate>2023-12-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DOM6.1 software bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><br /><strong>New features</strong><br />• Firmware zip package to release artifacts.<br />• Added support for DIO6·2 (16 x digital inputs and outputs).<br />• Added support for DIM6·1 (32 x digital inputs).<br />• Added support for DOM6·1 (32 x digital outputs).</p>
<p><br /><strong>Changes</strong><br />• SQP - Software Quality Plan.<br />• Aligned channel names with DIM5·1.<br />• Updated EBusCurrent in ESI.<br />• Changed the file names for the artifacts.<br />• Changed the group name to "AMC 600" in ESI file.<br />• Updated the vendor and group image in ESI XML.<br />• Bumped EtherCAT interface revision to v2.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DIO6.2 software bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dio62-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9cdb8b89-e7ed-4c1d-9f2c-5066b44ac4d6</guid>
        <pubDate>2023-12-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DIO6.2 software bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><br /><strong>New features</strong><br />• Firmware zip package to release artifacts.<br />• Added support for DIO6·2 (16 x digital inputs and outputs).<br />• Added support for DIM6·1 (32 x digital inputs).<br />• Added support for DOM6·1 (32 x digital outputs).</p>
<p><br /><strong>Changes</strong><br />• SQP - Software Quality Plan.<br />• Aligned channel names with DIM5·1.<br />• Updated EBusCurrent in ESI.<br />• Changed the file names for the artifacts.<br />• Changed the group name to "AMC 600" in ESI file.<br />• Updated the vendor and group image in ESI XML.<br />• Bumped EtherCAT interface revision to v2.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 MkII Firmware &#x2013; vR14.01</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mkii-firmware/r14-01/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">55f91570-98c9-4d37-92c6-e7588177c2a8</guid>
        <pubDate>2023-12-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 MkII Firmware</category>
        <category domain="version">R14.01</category>
          <category domain="product">SGC 120 Mk II</category>
        <content:encoded><![CDATA[
<p>SGC 120 Mk ll offline firmware initial release. R12.00 was the initial release for the SGC Mk ll variants. All previous releases were over smart flash.</p>
<h3>New feature:</h3>
<p>• Config and M-Logic flashing in live mode.<br />• Read event log in live mode.<br />• Added digital input sources in M-Logic.</p>
<p> </p>
<h3>Changes:</h3>
<p>• Updated start sequence to avoid breaker closure before safety monitoring expires.<br />• Updated the protection configuration range.<br />• Removed duplicated strings from language pack.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 MkII Firmware &#x2013; vR15.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mkii-firmware/r15-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">52132e14-e833-460d-8bd0-f45b8e8a803d</guid>
        <pubDate>2024-04-24T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 MkII Firmware</category>
        <category domain="version">R15.00</category>
          <category domain="product">SGC 120 Mk II</category>
        <content:encoded><![CDATA[
<h3>New feature</h3>
<p>• New engine protocol added:<br>&nbsp; - Angle<br>&nbsp; - Baudouin Wise10B<br>&nbsp; - Baudouin Wise15<br>&nbsp; - CAT ADEM6<br>&nbsp; - Caterpillar ADEM 3<br>&nbsp; - Caterpillar ADEM 4<br>&nbsp; - Caterpillar ADEM Generic<br>&nbsp; - Cummins CM2350<br>&nbsp; - Cummins CM2358<br>&nbsp; - Cummins CM2850<br>&nbsp; - Cummins CM2880<br>&nbsp; - Cummins KTA19<br>&nbsp; - DDEC III<br>&nbsp; - DDEC IV<br>&nbsp; - Deutz EMR 2<br>&nbsp; - Deutz EMR 3<br>&nbsp; - Deutz EMR 4<br>&nbsp; - Deutz EMR 5<br>&nbsp; - Deutz EMR Stage V<br>&nbsp; - Doosan G2 EDC17<br>&nbsp; - Doosan MD1<br>&nbsp; - Doosan Stage V<br>&nbsp; - FPT EDC17<br>&nbsp; - FPT Stage V<br>&nbsp; - Hatz EDC17<br>&nbsp; - Isuzu<br>&nbsp; - Iveco CURSOR<br>&nbsp; - Iveco EDC7<br>&nbsp; - Iveco NEF<br>&nbsp; - Iveco Stage V<br>&nbsp; - Iveco Vector8<br>&nbsp; - JCB<br>&nbsp; - JCB 430 448 Stage V<br>&nbsp; - Jichai JC15D WEIFU<br>&nbsp; - Jichai JC15T JG<br>&nbsp; - Jichai JC190<br>&nbsp; - Jichai WYS<br>&nbsp; - Jing Guan<br>&nbsp; - Kohler<br>&nbsp; - Kubota stage V<br>&nbsp; - MAN<br>&nbsp; - MAN EDC17<br>&nbsp; - MAN EMC Step 2.0<br>&nbsp; - MAN EMC Step 2.5<br>&nbsp; - MTU ECU8<br>&nbsp; - MTU ECU9<br>&nbsp; - MTU J1939<br>&nbsp; - Perkins ADEM 3<br>&nbsp; - Perkins EDC17C49<br>&nbsp; - Perkins Generic<br>&nbsp; - Perkins Stage V<br>&nbsp; - Perkins Stage V 1204J<br>&nbsp; - Perkins StV 1200<br>&nbsp; - Perkins StV 400<br>&nbsp; - PSI<br>&nbsp; - SDEC<br>&nbsp; - Steyr EDC17<br>&nbsp; - VE E483/E694 CPCB IV<br>&nbsp; - Volvo Penta EDC 3 (1500)<br>&nbsp; - Volvo Penta EDC 3 (1800)<br>&nbsp; - Volvo Penta EDC 4 (1500)<br>&nbsp; - Volvo Penta EDC 4 (1800)<br>&nbsp; - Volvo Penta EMS 2.3<br>&nbsp; - Volvo Penta EMS 2.4<br>&nbsp; - Volvo Penta EMS2<br>&nbsp; - Volvo Stage V<br>&nbsp; - Weichai E6 gas<br>&nbsp; - Weichai Gas<br>&nbsp; - Weichai Wise10B<br>&nbsp; - Weichai Wise15<br>&nbsp; - Xichai Gas<br>&nbsp; - YANMAR EDC17<br>&nbsp; - Yanmar Stage V<br>&nbsp; - Yuchai diesel<br>&nbsp; - Yuchai gas<br>&nbsp; - Yuchai Stage V<br>&nbsp; - Yuchai YC-BCR<br>• Digital input H polarity reversed.<br>• Data for unavailable sensor is not visible from the EIC view page.<br>• External EGR support over digital input added.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 MkII Firmware &#x2013; vR16.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mkii-firmware/r16-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f07f2d55-c2d6-4a7e-b46d-aa9d1a13511c</guid>
        <pubDate>2024-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 MkII Firmware</category>
        <category domain="version">R16.00</category>
          <category domain="product">SGC 120 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added 0-5V sensor selection for pin 23.</li>
<li>Added Custom Sensor.</li>
<li>Added Activation &amp; Delay for Custom Sensors.</li>
<li>EIC: Added support for Baudouin Gas.</li>
<li>EIC: Added support for Baudouin Wise10B.</li>
<li>EIC: Added support for Caterpillar ADEM 6.</li>
<li>EIC: Added support for Deutz EMR 5 Stage V.</li>
<li>EIC: Added support for Doosan Stage V.</li>
<li>EIC: Added support for Generic CPCB IV.</li>
<li>EIC: Added support for Isuzu.</li>
<li>EIC: Added support for Iveco Stage V.</li>
<li>EIC: Added support for JCB.</li>
<li>EIC: Added support for JCB 430/448 Stage V.</li>
<li>EIC: Added support for Jichai JC15D Weifu.</li>
<li>EIC: Added support for Jichai JC15T JG.</li>
<li>EIC: Added support for Jichai JC190.</li>
<li>EIC: Added support for Jichai WYS.</li>
<li>EIC: Added support for Jing guan.</li>
<li>EIC: Added support for John Deere.</li>
<li>EIC: Added support for John Deere Stage V.</li>
<li>EIC: Added support for Kohler.</li>
<li>EIC: Added support for MAN.</li>
<li>EIC: Added support for MAN EMC Step 2.0.</li>
<li>EIC: Added support for MAN EMC Step 2.5.</li>
<li>EIC: Added support for Perkins CPCB IV.</li>
<li>EIC: Added support for Perkins Stage V 120xJ.</li>
<li>EIC: Added support for PSI.</li>
<li>EIC: Added support for &nbsp;Scania EMS2 S6.</li>
<li>EIC: Added support for Weichai Diesel.</li>
<li>EIC: Added support for Weichai e6gas.</li>
<li>EIC: Added support for Weichai Gas.</li>
<li>EIC: Added support for Weichai Wise10B.</li>
<li>EIC: Added support for Weichai Wise15.</li>
<li>EIC: Added support for Yuchai.</li>
<li>EIC: Added support for Generic CPCB4 +.</li>
<li>Added Auto Load Transfer In Manual for Mains as a separate parameter.</li>
<li>New Data added over Modbus.&nbsp;</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Interlock of breaker feedback added as an interlock for Contactor latching of Generator and Mains.</li>
<li>The breaker on the display now mimics the contractor feedback.</li>
<li>Limited Counter Reset removed. The user can now reset any change multiple times with a password.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 MkII Firmware &#x2013; vR16.01</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mkii-firmware/r16-01/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f7118fa-9e76-47ab-83de-8f98ffa524d7</guid>
        <pubDate>2025-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 MkII Firmware</category>
        <category domain="version">R16.01</category>
          <category domain="product">SGC 120 Mk II</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed illegal Modbus address.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 MkII Firmware &#x2013; vR17.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mkii-firmware/r17-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bd5e923b-b73d-4d9c-8f8d-09676a29c61e</guid>
        <pubDate>2025-03-31T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 MkII Firmware</category>
        <category domain="version">R17.00</category>
          <category domain="product">SGC 120 Mk II</category>
        <content:encoded><![CDATA[
<h3>SGC 120 R17.00</h3>
<h3>New Features</h3>
<ul>
<li>DTC Manager: Added as a tool providing options to update SPN and FMI descriptions and ignore specific SPN/FMI codes.</li>
<li>Added the ability to display customer details on the boot-up screen through the display language tool.</li>
<li>Added Live Link for remote display functionality.</li>
<li>Added EIC support for the remote display product.</li>
<li>Added live button simulation implementation.</li>
<li>Added the LTO, remote acknowledge, auto mode, manual mode, digital inputs, and M-Logic event.</li>
<li>Added digital output for Louvre control command and pre-lube pump M-Logic command.</li>
<li>Added ECU override.</li>
<li>Added common screen for genset data.</li>
<li>Added ECI data on Modbus.</li>
<li>Added analogue sensor value in live data.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Phase reversal handling updated during the stop sequence.</li>
<li>Updated EIC protocol handling.</li>
<li>Improved SDEC protocol handling.</li>
<li>Updated MTU ECU9 Smart connect EIC modification.</li>
<li>Volvo Stage V EIC modifications.</li>
<li>Overload protection time has been increased from 600 to 3600 seconds.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 MkII Firmware &#x2013; vR18.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mkii-firmware/r18-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bccc3105-9027-4174-bed2-5f165f752bb5</guid>
        <pubDate>2025-12-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 MkII Firmware</category>
        <category domain="version">R18.00</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 120 Mk II</category>
        <content:encoded><![CDATA[
<h3>SCG 120 Version R18.0&nbsp;</h3>
<h3>New Features</h3>
<ul>
<li>Added support for MIO 100.</li>
<li>Added Custom Page Designer.</li>
<li>Added Yunnei protocol.</li>
<li>Added Motorpal version 2.1 protocol.</li>
<li>Added Cummins CM2670 protocol.</li>
<li>Added MTU ECU 9 Eminox protocol.</li>
<li>&nbsp;Added TSC1 in Volvo protocol.</li>
<li>Added configurable child SA (Sub Application).</li>
<li>Added configurable inducement strategy.</li>
<li>Added support for digital inputs via Modbus.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated Perkins CPCB IV protocol.</li>
<li>Aligned mute functionality with SGC 420 Mk II.</li>
<li>Aligned fuel tank capacity with SGC 420 Mk II.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 MkII Firmware &#x2013; vR14.07</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mkii-firmware/r14-07/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">65df18e5-4011-47c5-a47a-75496a18b72d</guid>
        <pubDate>2023-12-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 MkII Firmware</category>
        <category domain="version">R14.07</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<p>SGC 420 Mk ll offline firmware initial release. R12.00 was the initial release for the SGC Mk ll variants. All previous releases were over smart flash.</p>
<h3>New feature:</h3>
<p>• Added EIC - DDDEC protocol.<br />• Added EIC - John Deere protocol.<br />• Added EIC - John Deere Stage V Protocol.<br />• Added EIC - Scania S8 protocol.<br />• Added EIC - Kohler KDI3404 protocol.<br />• Added EIC - Bosch EDC17CV54 protocol.<br />• Added auto start and stop inhibit inputs.<br />• Added short to battery to sensors 3 and 4. <br />• Implemented Quick Flash (without config mode) for M-Logic.</p>
<p> </p>
<h3>Changes:</h3>
<p>• Updated start sequence to avoid breaker closure before safety monitoring expires.<br />• Removed the status screen lock during the start and stop sequences. <br />• Removed duplicated strings from display language pack.<br />• Removed duplicated strings from language pack.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 MkII Firmware &#x2013; vR15.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mkii-firmware/r15-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5793ce12-e2ce-4bc2-8d66-4a6a42c1a070</guid>
        <pubDate>2024-02-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 MkII Firmware</category>
        <category domain="version">R15.00</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>SGC 420 Mk ll offline firmware.</h3>
<h3>New feature:</h3>
<p>• Added these EIC protocols:<br />• PSI<br />• Isuzu<br />• Kohler<br />• JCB<br />• JCB 430/448 Stage V<br />• MAN<br />• Yuchai<br />• FPT Stage V<br />• Perkins Stage V<br />• Perkins Stage V 1204J<br />• Cummins KTA19<br />• Jichai JC15D Weifu<br />• Jichai WYS<br />• Jichai JC190<br />• Jichai JC15T JG<br />• Deutz EMR 5 Stage V<br />• Doosan Stage V<br />• Cummins CM2850<br />• Weichai e6gas<br />• Caterpillar ADEM 6<br />• Yanmar Stage V<br />• Volvo Stage V<br />• Volvo Penta EMS2<br />• MTU J1939<br />• Iveco Stage V<br />• Jing guan<br />• Deutz EMR 4<br />• Doosan G2 EDC17<br />• FPT EDC17<br />• Hatz EDC17<br />• MAN EDC17<br />• Perkins EDC17C49<br />• SDEC<br />• Steyr EDC17<br />• Xichai Gas<br />• YANMAR EDC17<br />• Yuchai YC-BCR<br />• Angle<br />• Baudouin Wise15<br />• Iveco CURSOR<br />• Iveco EDC7<br />• Iveco NEF<br />• Iveco Vector8<br />• Cummins CM2350<br />• Cummins CM2880<br />• Cummins CM2358<br />• DDEC III<br />• DDEC IV<br />• Deutz EMR 2<br />• Deutz EMR 3<br />• Deutz EMR 5<br />• Doosan MD1<br />• Kubota stage V<br />• MAN EMC Step 2.0<br />• MAN EMC Step 2.5<br />• MTU ECU8<br />• MTU ECU9<br />• Caterpillar ADEM 3<br />• Caterpillar ADEM 4<br />• Caterpillar ADEM Generic<br />• Perkins ADEM 3<br />• Perkins Generic<br />• Perkins StV 1200<br />• Perkins StV 400<br />• Volvo Penta EDC 3 (1500)<br />• Volvo Penta EDC 4 (1500)<br />• Volvo Penta EDC 3 (1800)<br />• Volvo Penta EDC 4 (1800)<br />• Volvo Penta EMS 2.3<br />• Volvo Penta EMS 2.4<br />• Weichai Gas<br />• Baudouin Wise10B<br />• Weichai Wise10B<br />• Weichai Wise15<br />• Yuchai diesel<br />• Yuchai gas<br />• VE E483/E694 CPCB IV</p>
<p> </p>
<h3>Changes:</h3>
<p>• Fixed issue with mains timer.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 MkII Firmware &#x2013; v16.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mkii-firmware/16-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5afa9ffe-2d57-4710-b790-38972995727b</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 MkII Firmware</category>
        <category domain="version">16.00</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New Features</h3>
<p>• EIC : Added support of Generic CPCB4+.<br>• EIC : Added support of Perkins CPCB4+.<br>• EIC : Added support of Scania EMS2 S6.<br>• EIC : Added support of Baudouin Gas.<br>• EIC : Updated SPN description database.<br>• Added Digital Input functions in M-logic Commands.<br>• Updated Custom Sensor Range Change to -3000 to 3000<br>• X (resistance, mA / V) Value in Live data view.<br>• Added DTC over MODBUS.<br>• Added Shutdown as fail Class in Maintenance Alarm.</p>
<p>&nbsp;</p>
<h3>Changes</h3>
<p>• Run Hour Time available in both hours &amp; minutes.</p>
<p>&nbsp;</p>
<h3>Corrections</h3>
<p>• Fixed issue when "Auto Restore Inhibit" &amp; "Mains Load Inhibit" are configured together.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 MkII Firmware &#x2013; vR17.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mkii-firmware/r17-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">38b12774-5577-4989-bdd0-ed23aba9149f</guid>
        <pubDate>2025-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 MkII Firmware</category>
        <category domain="version">R17.00</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>DTC manager: added as a tool providing options to update SPN and FMI descriptions and ignore specific SPN/FMI codes.</li>
<li>Added the ability to display customer details on the boot-up screen through the display language tool.</li>
<li>Added Live link for remote display functionality.</li>
<li>Introduced a shutdown override function in digital inputs, allowing all shutdown alarms (except emergency stop) to be treated as warnings when activated.</li>
<li>Added "Shutdown" as an alarm action in the maintenance module.</li>
<li>Added activation and delay timers for custom sensors.</li>
<li>Added auto load transfer in manual mode as a separate parameter for mains.</li>
<li>Enabled external EGR support through digital input.</li>
<li>Added file information to relevant screens.</li>
<li>Added EIC data over Modbus.</li>
<li>Introduced an alternate nominal AC system.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Added breaker feedback interlock for generator and mains breakers.</li>
<li>The breaker status on the display now mimics the contractor / breaker feedback.</li>
<li>Nominal AC system configuration moved from alternator configuration to nominal values.</li>
<li>Updated Phase reversal handling during the stop sequence.</li>
<li>Updated EIC protocols:<br>&nbsp; - Improved SDEC protocol handling.<br>&nbsp; - Updated MTU ECU9 Eminox protocol.<br>&nbsp; - Updated Volvo Stage V protocol.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 MkII Firmware &#x2013; vR18.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mkii-firmware/r18-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8f418c1d-5016-4dc1-a8f0-076ddf893cde</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 MkII Firmware</category>
        <category domain="version">R18.00</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h4>R18.0 based on R17.0</h4>
<h3>New Features</h3>
<ul>
<li><span>Mute function for the low level inducement</span></li>
<li><span>Bosch MD1CE101, pointing to Generic J1939</span></li>
<li><span>RDC100 support</span></li>
<li><span>ECU Override function</span></li>
<li><span>Common/Genset Data screen</span></li>
</ul>
<h3>Changes</h3>
<ul>
<li><span>Increase Overload Delay range (from 600 to 3600 seconds)</span></li>
<li><span>Change minimum Fuel Level Range (from 2L to 0L)&nbsp;</span></li>
<li><span>Modification of logic to display Fuel in litres on screen,</span>&nbsp;based on Fuel Level Value</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 MkII Firmware &#x2013; vR19.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mkii-firmware/r19-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e6823288-bdbf-4e0e-9ff0-914e4e81867e</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 MkII Firmware</category>
        <category domain="version">R19.00</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h4>R19.0 based on R18.0</h4>
<h3>New features</h3>
<ul>
<li>Introduced the LTO function.</li>
<li>Added the ability to mute low-level alarms.</li>
<li>Added support for updating dedicated public variables via Modbus.</li>
<li>Added support for the following engine communication protocols:</li>
<li>Motorpal 2.1</li>
<li>SDEC F31</li>
<li>SDEC ECTEK F36</li>
<li>Kingbang</li>
<li>Wise 18B</li>
<li>Volvo Penta CPCB IV&nbsp;</li>
</ul>
<div></div>
<h3>Changes</h3>
<ul>
<li>The genset voltage and energy screens are now automatically hidden when alternator monitoring is disabled.</li>
<li>The mains voltage and energy screens are now automatically hidden when mains monitoring is disabled.</li>
<li>The Stop action timer range has been extended.</li>
</ul>
<h3>Improvements</h3>
<div>
<ul>
<li>Updated warning and shutdown return/trip interlocks to allow finer threshold differentiation and improved system accuracy.</li>
</ul>
</div>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DIO6.1 software bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dio61-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3239eb63-34fc-4d76-b5ea-bc58af2d9db5</guid>
        <pubDate>2023-12-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DIO6.1 software bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><strong>New features</strong><br />• Firmware zip package to release artifacts.<br />• Added support for DIO6·2 (16 x digital inputs and outputs).<br />• Added support for DIM6·1 (32 x digital inputs).<br />• Added support for DOM6·1 (32 x digital outputs).</p>
<p><br /><strong>Changes</strong><br />• SQP - Software Quality Plan.<br />• Aligned channel names with DIM5·1.<br />• Updated EBusCurrent in ESI.<br />• Changed the file names for the artifacts.<br />• Changed the group name to "AMC 600" in ESI file.<br />• Updated the vendor and group image in ESI XML.<br />• Bumped EtherCAT interface revision to v2.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 Firmware &#x2013; vR9.11</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-firmware/r14-01/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">afbed261-1d3a-4f2e-8955-d89c4b3ed855</guid>
        <pubDate>2024-02-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 Firmware</category>
        <category domain="version">R9.11</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 120</category>
        <content:encoded><![CDATA[
<p>Initial release of SGC 120 offline firmware R9.11. All previous releases were over smart flash.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 Firmware &#x2013; vR8.09</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-firmware/r14-07-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dbd6f37e-d3e1-4598-9aee-d4788586c37c</guid>
        <pubDate>2024-02-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 Firmware</category>
        <category domain="version">R8.09</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 420</category>
        <content:encoded><![CDATA[
<p>Initial release of SGC 420 offline firmware R8.09. All previous releases were over smart flash.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2000/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1ada165f-206f-486e-ae83-1bcd0c54a051</guid>
        <pubDate>2024-02-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.0.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>One single file which contains the entire application SW for the controller</li>
</ul>
<p> </p>
<p>To be used with at the least PICUS version 1.0.21.0</p>
<p> </p>
<h3>New features:</h3>
<p>• Initial release</p>
<p> </p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.0.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2001/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1c8c2eb5-ccfc-48a3-a459-424220540f67</guid>
        <pubDate>2024-02-23T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.0.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>One single file which contains the entire application SW for the controller</li>
</ul>
<p> </p>
<p>To be used with at the least PICUS version 1.0.21.0</p>
<p> </p>
<h3>Changes:</h3>
<p>Changed SSH service to OFF by default.</p>
<p> </p>
<h3>Corrections:</h3>
<p>-Corrected an issue in emulation causing the controller to restart.<br />-Corrected the naming of the action choices for the "CAN fail mode alarm".<br />-Corrected reactive energy unit from kvar to kvarh.<br />-Corrected an issue causing the DEF level to not be shown by default on the Exhaust after-treatment dashboard.<br />-Corrected an issue causing the auto-jump to the Exhaust after-treatment dashboard not to work.<br />-Corrected an issue on the Exhaust after-treatment dashboard where the engine lamps would not appear when transitioning directly from N/A to ON.</p>
<p> </p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">86024ef1-2d66-429a-bf73-ce791b0cc37f</guid>
        <pubDate>2024-04-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.1.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>This software package consist of:</h3>
<ul>
<li>One single file which contains the entire application SW for the controller</li>
</ul>
<p>&nbsp;</p>
<p>To be used with at the least PICUS version 1.0.21.0</p>
<p>&nbsp;</p>
<h3>New features:</h3>
<p>• Added a navigation item linked to CODESYS Webvisu allowing a seamless transfer to the WebVisualization page.</p>
<p>&nbsp;</p>
<h3>Corrections:</h3>
<p>• Corrected issue where the "Communication settings changed" alarm was incorrectly triggered.<br>• Corrected the menu structures in the display menu.<br>• Corrected inconsistent configuration of network and port settings in the browser configuration tool.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.4.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-4-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">07a57df6-86e1-4973-8aae-85585acb12ea</guid>
        <pubDate>2024-07-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.4.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<p>Minimum required version of PICUS: <strong>1.0.22.0</strong></p>
<h3>New features</h3>
<ul>
<li>An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Security Log Management requirements.</li>
<li>Updated Volvo EMS2.4 to support ACM module.</li>
<li>EIC: Added support for CAT C7.1.</li>
<li>EIC: Added support for Kohler KDI3404.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed default value for the regulator status text.</li>
<li>Added support for adjusting the brightness level on the controller.</li>
<li>Fixed visibility of ECU and CAN parameters.</li>
<li>Fixed issue where Custom Logic was missing.</li>
<li>Fixed issue where the licence error alarm could occur after a restore from a backup.</li>
<li>Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.</li>
<li>Fixed issue where disclaimer was incorrectly shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.7.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-7-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">80f37ea0-3c42-4606-a592-dd9ae779ef14</guid>
        <pubDate>2024-11-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.7.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<p>Minimum required version of PICUS: <strong>1.0.22.0</strong></p>
<h3>New features</h3>
<ul>
<li>EIC: Added a parameter to configure TSC1 destination address.</li>
<li>Added EIC protocol Yanmar Stage V.</li>
<li>Added EIC protocol Jichai JC15T JG.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>TSC1 corrected for Caterpillar, Perkins, Iveco Vector8 and John Deere. VP70 source address corrected for Volvo Penta EMS2 and EMS2.3.</li>
<li>EIC: Ash load percentage is available on Modbus and the display.</li>
<li>Fixed issue where screen was white on startup.</li>
<li>EIC: Corrected frequency selection for Volvo Penta EMS 2.4.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.7.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-7-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dc6c4618-4695-4567-bbdf-063c3eabe088</guid>
        <pubDate>2024-12-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.7.2</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<p>Minimum required version of PICUS: 1.0.23.0</p>
<h3>Corrections</h3>
<ul>
<li>EIC start/stop now works on all protocols. Small fixes made to CAT7.1.</li>
<li>Fixed issue where display preferences were not stored during power cycle.</li>
<li>Fixed issue where display did not exit dimmed state.</li>
<li>Fixed issue where Web.config was not bundled correctly in the RAUC bundle.</li>
<li>Implemented Yanmar Stage V regeneration acknowledge lamp.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9d5ccf29-3dcf-47ac-95c4-1f7d61ef3d06</guid>
        <pubDate>2025-01-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.7.2</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: It is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue causing Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">004c0b1e-6f79-4ce9-b6fb-a46f8c77c4ce</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue that sometimes prevents start-up of controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improved wire break detection handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">32859de0-70de-429f-a716-14387c966206</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be set up to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to&nbsp;use in the flexible Modbus. &nbsp;</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350. &nbsp;</li>
<li>Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.</li>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control".</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.&nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI were not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups could not be collapsed using touch.</li>
<li>Fixed issue where iE 250 failed to start up without MIO module.</li>
<li>Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.</li>
<li>Fixed issue where display user could not clear DM2 logs.</li>
<li>Fixed issue where iE controller could not start without MIO module.&nbsp;</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where user could enter parameter values outside of valid range.</li>
<li>Fixed issue where genset, GB, and MB could not be operated when the controller was running in NO REG mode.</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Fixed issue where PIM2.1 DIO levels were inverted.</li>
<li>Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms.&nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS were hidden in IO configuration.</li>
<li>Fixed issue where PWM was not working on MIO2.1.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/20101/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cd293179-5a7f-4433-a966-b2c6faff4d00</guid>
        <pubDate>2025-06-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>2.0.10.1 based on 2.0.9.0</h4>
<h3>New features</h3>
<ul>
<li>The user can now read the device serial number in CODESYS</li>
</ul>
<p>&nbsp;</p>
<h3>Corrections</h3>
<ul>
<li>&nbsp;Adjusted genset loading behaviour to ensure alignment with genset deloading across products</li>
<li>The frequency and voltage regulation mode is no longer dependent on the frequency detection level when running with the GB closed</li>
<li>Opening I/Os in a backup or config file no longer results in an error popup</li>
<li>Improved fieldbus connection handling to show the correct connections</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b76f4b67-a64d-4173-879e-9e478e51c1cf</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.&nbsp;</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK. &nbsp;</li>
<li>Fixes an issue where it was not possible to set Port mode to RSTP External.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ba73a25e-154e-451d-b24a-5e3c353dba67</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>&nbsp;Fixed issue where it was not possible to back up and restore user management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">afc58d64-5303-424a-9332-c895bcbcc102</guid>
        <pubDate>2025-08-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.12.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>2.0.12.0 based on 2.0.11.2</h4>
<h3>New features:</h3>
<ul>
<li>Fault Ride Through (FRT)</li>
<li>Capability curve</li>
<li>Feed Forward</li>
<li>Mains sync inhibit</li>
<li>Power ramps</li>
<li>Droop curves</li>
<li>Mains external measurement input</li>
<li>Q regulation</li>
<li>var regulation</li>
<li>New inhibit for active FRT</li>
<li>New measurement system for frequency based on the average frequency over multiple phases</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed ports not opening on redundancy connection topology</li>
<li>Fixed IO translations</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1f77c8bd-f086-4541-815d-08a7a5b81574</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Fixed issue with the Breaker OFF button in Emulation mode.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">41627ab6-e42f-455a-9251-a103b73c787b</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.1 (based on version 2.0.15.0)</h4>
<h3>New features</h3>
<ul>
<li>Added a visualisation of the engine limit in the capability curve.</li>
<li>Added support for negative values in the capability curve.</li>
<li>EtherCAT® performance improvements, enhancing communication between the PCM3.3, modules, and extension racks.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the selected display header remained active after a power cycle of the controller.</li>
<li>Corrected the regulation reference when using external analogue power measurements or a fourth current input.</li>
<li>Users can no longer enter invalid values for the recovery and active-time parameters for fault ride-through.</li>
<li>VDE tags are now visible on all FRT parameters.</li>
<li>The ramp now correctly freezes together with the regulator during an FRT event.</li>
<li>Fixed an issue where, in some cases, a restore did not restore parameters correctly.</li>
<li>Test mode is no longer cancelled when the mode is issued.</li>
<li>Fixed an issue where some parameters could not be read correctly in CODESYS on iE 250 LC.</li>
<li>Fixed an issue which caused controller to restart if user did not take action</li>
</ul>
<h4>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Only relevant slope parameters are shown for Droop curve 1.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
<li>Updated grid code menu structure and changed some texts.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>New parameter Frequency recovery added for handling frequency recovery specifically for Volvo Penta engines when doing 100 % active power load jumps.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes:</h3>
<ul>
<li>Architectural updates in preparation for new power management</li>
<li>Architectural updates in preparation for new grid codes</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue where the bootloader was not updating correctly</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 operating, causing a System Not OK alarm</li>
<li>Fixed an issue with GAM 3.2 configuration when in stand alone for analogue regulation&nbsp;</li>
<li>Fixed issue with synchronisation visualisation</li>
<li>Fixed issue where permissions were missing after a backup/restore cycle</li>
<li>Fixed issue which affected performance of analogue regulation on the analogue bidirectional IO terminals</li>
<li>Fixed issue with logout message on Web Config</li>
<li>Fixed issue with new password error in User Management</li>
<li>Fixed issue with spurious info taking up log entries, making it harder to see valid log entries</li>
<li>Fixed issue with reactive power measurement in emulation</li>
<li>Fixed issue with active power measurement in emulation</li>
<li>Fixed issue where duplicated logs were made for breaker actions</li>
<li>Fixed issue where Chinese characters were not shown correctly</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (CAN-based Power Management) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">222dd29b-dd59-4b10-b670-86e3cf99d7e1</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (CAN-based Power Management)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present after a factory reset.</li>
<li>Added missing measurement SPN 6321.</li>
<li>Introduced a new visual representation of the capability curve on iE 250 LC.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Expanded diagnostic message support with all valid SAE J1939 SPN texts for DM1 and DM2 alarm descriptions.</li>
<li>Introduced a preview function that enabled redundant Power Management System (PMS) CAN communication on iE 250 LC by allowing CAN port A and CAN port B to be used simultaneously. When enabled and CAN port B was selected for PMS communication, a device reboot was required.</li>
<li>Added power feed-in management support to iE 250 LC.</li>
<li>Introduced parameter preset functionality for fault ride-through.</li>
<li>Added RSTP support, enabling switching between RSTP switches in a running system.</li>
<li>Added support for the fault ride-through requirements in Grid Code 2025.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated the I/O configuration experience for iE 250 controller AIOs.</li>
<li>Renamed df/dt to RoCoF across all menus for improved consistency.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user was not present after a factory reset.</li>
<li>Fixed a defect that allowed controller variant checks to be overridden during backup restore.<br>Fixed a defect where restoring older backups on version 2.0.15.0 or newer could block login to the controller from the CODESYS Development System (IDE).</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed backup restore failures for backups larger than 50 MB.</li>
<li>Fixed a defect where some parameters could not be read correctly in CODESYS Development System on iE 250 LC.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Fixed a defect in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
<li>Corrected incorrect source addressing for TSC1 and CM1 for FPT / Iveco Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.2 Software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle-1/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">43f3e5cf-11b2-4860-9ab2-79653aea363f</guid>
        <pubDate>2024-03-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.2 Software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><strong>New features:</strong></p>
<p>- Firmware zip package to release artifacts<br />- Support for AIO6·2 (8 x analogue inputs and outputs)<br />- Support for AOM6·2 (8 x analogue outputs)<br />- PDO support for output status (0x1A00)<br />- Terminal description to user manual<br />- Bump AIO6·1 EtherCAT revision to version 5</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.2 Software bundle &#x2013; v1.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle-1/1-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3154afdd-37df-47b8-88c5-8d62569a7eac</guid>
        <pubDate>2025-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.2 Software bundle</category>
        <category domain="version">1.0.3.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3><strong>Changes:</strong></h3>
<ul>
<li>Use DAC Full-tracking mode to improve power dissipation in AIO6·2</li>
<li>Use extended ranges in DAC8775 to improve edge values in AIO6·2</li>
<li>Improve precision for analog output 4-20mA range</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIO6.2 Software bundle &#x2013; v1.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aio61-software-bundle-1/1-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">627fb73e-fe53-4652-ae2b-f5291e662c6c</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIO6.2 Software bundle</category>
        <category domain="version">1.0.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.0.4.0] - 2025-10-02</h4>
<h3>New features</h3>
<ul>
<li>Added support for -12 to 12 V and 0 to 12 V analogue inputs and outputs</li>
<li>Added support for -24 to 24 mA and 0 to 24 mA analogue inputs and outputs</li>
<li>Added support for 4 to 20 mA NAMUR NE43 analogue inputs</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Prevent polarity shift when voltages below -10 V are applied to 0 to 10 V analogue inputs</li>
<li>Fixed under-range detection for 4 to 20 mA with a 0.4% margin</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AOM6.2 Software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aom62-software-bundle/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0d03614a-1860-42a1-a5cf-11b0e5555b1b</guid>
        <pubDate>2024-03-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AOM6.2 Software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><strong>New features:</strong></p>
<p>- Firmware zip package to release artifacts<br />- Support for AIO6·2 (8 x analogue inputs and outputs)<br />- Support for AOM6·2 (8 x analogue outputs)<br />- PDO support for output status (0x1A00)<br />- Terminal description to user manual<br />- Bump AIO6·1 EtherCAT revision to version 5</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AOM6.2 Software bundle &#x2013; v1.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aom62-software-bundle/1-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2760130f-889f-49bf-bc0c-c0b3e2bafb10</guid>
        <pubDate>2025-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AOM6.2 Software bundle</category>
        <category domain="version">1.0.3.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Changed</h3>
<ul>
<li>Use DAC Full-tracking mode to improve power dissipation in AOM6·2</li>
<li>Use extended ranges in DAC8775 to improve edge values in AOM6·2</li>
<li>Improve precision for analog output 4-20mA range</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AOM6.2 Software bundle &#x2013; v1.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aom62-software-bundle/1-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cf5b4cd8-7cda-4cd6-80cd-fb3e7042cc3b</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AOM6.2 Software bundle</category>
        <category domain="version">1.0.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.0.4.0] - 2025-10-02</h4>
<h3>New features</h3>
<ul>
<li>Added support for -12 to 12 V and 0 to 12 V analogue outputs</li>
<li>Added support for -24 to 24 mA and 0 to 24 mA analogue outputs</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2e4f8fbf-f6a2-4149-9129-6b5123bf9dd0</guid>
        <pubDate>2024-04-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.1.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<ul>
<li>CODESYS IDE libraries for iEx50 v. 2.0.1.0</li>
</ul>
<p> </p>
<h3>New features:</h3>
<p>• Added a navigation item linked to CODESYS Webvisu allowing a seamless transfer to the WebVisualization page.</p>
<p> </p>
<h3>Corrections:</h3>
<p>• Corrected issue where the "Communication settings changed" alarm was incorrectly triggered.<br />• Corrected the menu structures in the display menu.<br />• Corrected inconsistent configuration of network and port settings in the browser configuration tool.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a934bda4-2b8e-4093-bdec-a9badf19021d</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<p>Land CODESYS Interface Libraries for iE250/iE350 v2.0.2.0</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4b5d91a3-d2bc-4986-9102-f0af63649011</guid>
        <pubDate>2025-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<p>CODESYS Interface Libraries are updated to match New features and changes to iE LC application for iE 250 LAND and iE 350 LAND.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a0956fe5-5d9d-42c7-9760-077f27396ea6</guid>
        <pubDate>2025-05-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Interface Libraries</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">439b860f-ac4a-49ac-9038-6d51306d0d49</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.10.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.0] - 2025-06-11</h4>
<h3>New feature</h3>
<ul>
<li>Enabled deprecated code in libraries</li>
</ul>
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.10.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3de25b29-f40a-4201-821c-e1f7f5dab12c</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.11.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.12.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-12-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">55b41644-0ec7-45ce-b98c-62c4e9670ead</guid>
        <pubDate>2025-09-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.12.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Changed databases to v2.0.12.0</li>
<li>Updated iE_main to v2.0.0.2 to include support for old HTTP/1.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b91e0fe8-3b12-470a-84d6-36b920c5472b</guid>
        <pubDate>2025-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Changed</h3>
<ul>
<li>Databases changed to version 2.0.13.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c22114fc-4a8f-43dc-9c50-3ea38a7a25a3</guid>
        <pubDate>2025-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.14.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>## [2.0.14.0] - 2025-10-30</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.14.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d7cdc2b2-ac6a-4644-994b-d90bb0d123e5</guid>
        <pubDate>2025-12-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.15.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>## [2.0.15.0] - 2025-12-17</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.15.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS libraries &#x2013; v2.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-libraries/2-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f376aa61-980f-44ef-8b8f-db0c72628623</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS libraries</category>
        <category domain="version">2.0.16.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Databases changed to version 2.0.16.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">195074dd-6b6c-43ea-935d-13744a767d6a</guid>
        <pubDate>2024-04-19T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.1.0</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<p><strong>Initial release of the iE 250 PLC.</strong></p>
<p>The iE 250 PLC embodies a robust, adaptable, and modular programmable controller ideal for crafting forward-looking intelligent energy management systems.&nbsp;<br>With its comprehensive suite of features, this PLC caters to the needs of designers, installers, and operators with ease.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">929c01b9-92ff-4263-8a1e-2b1962815923</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<p><strong>Changes</strong><br>- Software bundle aligned across all iE x50 formfactors</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6c88a537-ebeb-41dd-b861-78ca36e2e840</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.4.0</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h3><strong>Changes</strong></h3>
<ul>
<li>Performance and stability improvements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.5.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-5-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4fe6b1a9-fab0-41d6-a660-1af621ee509f</guid>
        <pubDate>2024-12-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.5.1</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Local Digital IO support on PCM2.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1c3bec44-d62a-48a8-90ec-09b368ffdfe5</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<p>This release includes general improvements to the iE PLC family.&nbsp;</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port when not in use.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Network port configuration: New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: Is is now possible to press Info when the search filter is highlighted.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">18a857d4-5570-48e8-8d2b-6d4b47cff422</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h2>&nbsp;[2.0.8.1] - 2025-02-06</h2>
<h3>Changes</h3>
<ul>
<li>Fixed issue where EtherCAT master service is not enabled or disabled as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f8894f59-1424-4d5a-84d8-0deae91b5db0</guid>
        <pubDate>2025-05-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h4>Updates to CODESYS SP support, packaging and libraries.</h4>
<h3>New Features</h3>
<ul>
<li>TSP packages are now signed</li>
<li>Added IOM33 devdesc 1.0.0.2, Revision=16#01000003</li>
<li>Added IOM33 devdesc 1.0.0.4, Revision=16#01000004</li>
<li>iEBSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Support for CODESYS runtimes v3.5.18.40 removed PCM21, PCM33 and PCM62</li>
<li>Merged TSP packages for PCM21, PCM33 and PCM62 into one .package file</li>
<li>Update DEIF_SysUtil_PCM61 to v1.0.0.1. Added selection of termination for CAN ports</li>
<li>Modbus RTU, removed Pcm51Clib dependency, Modbus RTU is not included in TSPs</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">113ef10d-d08e-43bd-8209-5db27f43158d</guid>
        <pubDate>2025-06-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.1] - 2025-06-18</h4>
<p>New minor release with improvement in installation process.</p>
<h3>New features</h3>
<ul>
<li>Added support for PIM4AIO and PIM8DIO modules</li>
<li>Introduced iE BSP v1.0.0.0, including: GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS runtimes v3.5.18.40, PCM2.1, PCM3.3 and PCM6.2</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1, added selection of terminations for CAN ports</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10070a95-fadc-4116-a5b8-4fab1c6f7556</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">43f515ef-6da1-4c29-a1f2-22c304fd059e</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>&nbsp;Fixed issue where it was not possible to back up and restore user management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10973687-c35e-4749-84b6-c157255a2cad</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h4>2.0.16.1</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System to v3.5.21.40.</li>
<li>Added MIO2.1 devdesc v1.1.0.0, revision = 16#01010000.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Get serial number from BSP API</li>
</ul>
<h4>2.0.15.1</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the Modbus TCP default port (502) was blocked by the firewall.</li>
</ul>
<h4>2.0.15.0</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue in WebConfig where the user could accidentally press Apply multiple times when configuring the network.</li>
</ul>
<h4>2.0.14.1</h4>
<p>Minor release with cybersecurity-related improvement.</p>
<h3>Improvements</h3>
<ul>
<li>Corrected authentication issue.</li>
</ul>
<h4>2.0.14.0</h4>
<h3>This bundle includes:</h3>
<ul>
<li>Upgrade to CODESYS Runtime System version 3.5.21.10 (SP21 Patch 10).</li>
<li>Added NAMUR NE43 support on iE 650 PLC Analogue Inputs.</li>
<li>Improvements to user login and password validation.</li>
<li>Enhancements to the system log in WebConfig.</li>
</ul>
<h3>Improvements</h3>
<ul>
<li>WebConfig: Automatic logout message displayed upon failure.</li>
<li>WebConfig: Password confirmation required during input.</li>
<li>Corrected issue where the bootloader was not consistently updated.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>WebConfig: Resolved issue where the log was being filled with its own log messages.</li>
<li>WebConfig: Software version is now shown after login.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>WebConfig: Added list of open-source licences.</li>
<li>BSP: Updated splash screen and upgraded to CODESYS Runtime System version 3.5.21.10.</li>
<li>IO: Updated firmware for IOM3.2, IOM3.3, and IOM3.4 to version 1.0.0.4 (see dedicated change log).</li>
<li>IO: Updated firmware for AIM6·1, AIM6·2, AIO6·1, AIO6·2, and AOM6·2 to version 1.4.0.0 (see dedicated change log).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 PLC Software &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-plc/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ffe43bdc-1131-4104-a2e4-e566b7da63d0</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 PLC Software</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added a workaround to prevent the CODESYS OPC UA server from stopping parameters unexpectedly.</li>
<li>Added an additional check to ensure that a valid default administrator user exists after a factory reset.</li>
<li>Added RSTP support, so swapping between RSTP network switches now works in a running system.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the administrator user was not present after a factory reset.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 PCM6.2 software bundle  &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-pcm62-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6f6d814a-778a-40c1-a761-462feacc59fc</guid>
        <pubDate>2024-05-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 PCM6.2 software bundle </category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p><strong>New features</strong></p>
<p>- PCM LED description in User's manual.<br>- Firmware zip package to release artifacts.<br>- Support for PCM6·2.</p>
<p><strong>Changes</strong></p>
<p>- Updated vendor and group image in ESI XML.<br>- Changed EtherCAT interface revision to v3.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407M 410M 415M 421M &#x2013; v1.3.868</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi_407m_410m_415m_421m/1-3-868/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">54cbe92d-d3d9-4bb6-ac88-15ee3f9f369b</guid>
        <pubDate>2024-05-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407M 410M 415M 421M</category>
        <category domain="version">1.3.868</category>
        <content:encoded><![CDATA[
<p>First release of 415M/421M BSP software.</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 407M 410M 415M 421M &#x2013; v3.1.421</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi_407m_410m_415m_421m/3-1-421/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c9a93c6f-cb36-456a-a0b8-f6ac68d2ce39</guid>
        <pubDate>2024-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 407M 410M 415M 421M</category>
        <category domain="version">3.1.421</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<h3>Added</h3>
<ul>
<li>Auditable events.</li>
<li>Session lock.</li>
<li>Authorisation enforcement for all users + role mappings.</li>
<li>Identification and authentication of users.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where application package failed to install if zip archive was created under Windows.</li>
<li>Fixed issue where interfaces were not always reachable after reconfiguring network.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f9acd2b8-fab3-46c5-bb51-755415b7ec9a</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<p>Initial release of Marine CODESYS Interface Libraries for iE 250/iE 350 v2.0.2.0</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">acbe3c07-234e-456d-9ad1-cc526869d27d</guid>
        <pubDate>2025-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<p>CODESYS Interface Libraries are updated to match New features and changes to iE 250/350 MS application.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">25c1394e-707d-4532-a781-b39a25849fec</guid>
        <pubDate>2025-05-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3><br>Changes</h3>
<ul>
<li>Updated CODESYS Interface Libraries</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fb34452a-dd2f-4b4c-8294-08801066d01b</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.10.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.0] - 2025-06-11</h4>
<h3>New feature</h3>
<ul>
<li>Enabled deprecated code in libraries</li>
</ul>
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.10.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c6a136bb-9b77-449f-ab3e-378e877aba9e</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.11.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3a486077-78a9-4a3d-941b-f5c6e639b8d0</guid>
        <pubDate>2025-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Changed</h3>
<ul>
<li>Databases changed to version 2.0.13.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e342f804-e859-4ced-be69-77517dda1b8e</guid>
        <pubDate>2025-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.14.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>## [2.0.14.0] - 2025-10-30</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.14.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ce3b3442-7fd6-4a99-8f48-ca12071b04b4</guid>
        <pubDate>2025-12-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.15.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>## [2.0.15.0] - 2025-12-17</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.15.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine CODESYS libraries &#x2013; v2.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-codesys-libraries/2-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf8204e0-f7f5-4a43-bc95-420dfac43887</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine CODESYS libraries</category>
        <category domain="version">2.0.16.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Databases changed to version 2.0.16.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f25102d-0f1f-4965-807f-9395e973e2f1</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Package consist of the following:</h3>
<p>Initial release Marine PM CODESYS Interface Libraries for iE 250/iE 350 v2.0.2.0</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9dc3557d-2d99-4ab3-b6df-53043163e10e</guid>
        <pubDate>2025-05-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Interface Libraries</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">39a5e9dc-8cc9-48ee-b87a-c94cd758296c</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.10.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.0] - 2025-06-11</h4>
<h3>New feature</h3>
<ul>
<li>Enabled deprecated code in libraries</li>
</ul>
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.10.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d46f18b8-0b84-4839-b60c-5ac87e5d14aa</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.11.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5665c65d-8c24-4673-b1e2-0f24fb50199d</guid>
        <pubDate>2025-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Changed</h3>
<ul>
<li>Databases changed to version 2.0.13.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">641bd133-3185-4a55-b02d-ae44c3c82010</guid>
        <pubDate>2025-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.14.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>## [2.0.14.0] - 2025-10-30</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.14.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">61ec53d4-3a32-44d6-ad07-aeb408e68398</guid>
        <pubDate>2025-12-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.15.0</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>## [2.0.15.0] - 2025-12-17</h3>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.15.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Marine PM CODESYS libraries &#x2013; v2.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-marine-pm-codesys-libraries/2-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9f1a8f00-5edf-442c-84fc-bbf5ef644282</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Marine PM CODESYS libraries</category>
        <category domain="version">2.0.16.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Databases changed to version 2.0.16.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 PCM6.1 IF software bundle &#x2013; v1.0.1.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-pcm61-if-software-bundle/1-0-1-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">080f017d-6e39-4279-b05d-5038ead4571a</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 PCM6.1 IF software bundle</category>
        <category domain="version">1.0.1.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Added:</h3>
<p>- PCM LED description in User's manual<br>- Firmware zip package to release artifacts</p>
<p>&nbsp;</p>
<h3>Changed:</h3>
<p>- Update vendor and group image in ESI XML<br>- Bump EtherCAT interface revision to v3</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">15cba975-46ac-4367-aa62-d3fa79e925e7</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<p><strong>Initial release of the iE 350 PLC.</strong></p>
<p>The iE 350 PLC is a robust, adaptable, and modular programmable controller, ideal for crafting forward-looking intelligent energy management systems.&nbsp;<br>With its suite of features, this PLC caters to the needs of designers, installers, and operators with ease.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c82b62c3-5a03-41ed-879e-d3abc8c60722</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.4.0</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Performance and stability improvements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3c2e458e-50dd-4dce-aa0d-aaa4a4781d31</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<p>This release includes general improvements to the iE PLC family.&nbsp;</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port when not in use.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.<br>&nbsp;</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: It is now possible to press Info when the search filter is highlighted.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40<br>&nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c2f99e80-0efe-4b12-b0a5-4342b72540d1</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h2>[2.0.8.1] - 2025-02-06</h2>
<h3>Changes</h3>
<ul>
<li>Fixed issue where EtherCAT master service is not enabled or disabled as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10fd4be3-3169-48b7-b5ef-15240fb0d621</guid>
        <pubDate>2025-05-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h4>Updates to CODESYS SP support, packaging and libraries.</h4>
<h3>New Features</h3>
<ul>
<li>TSP packages are now signed</li>
<li>Added IOM33 devdesc 1.0.0.2, Revision=16#01000003</li>
<li>Added IOM33 devdesc 1.0.0.4, Revision=16#01000004</li>
<li>iEBSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Support for CODESYS runtimes v3.5.18.40 removed PCM21, PCM33 and PCM62</li>
<li>Merged TSP packages for PCM21, PCM33 and PCM62 into one .package file</li>
<li>Update DEIF_SysUtil_PCM61 to v1.0.0.1. Added selection of termination for CAN ports</li>
<li>Modbus RTU, removed Pcm51Clib dependency, Modbus RTU is not included in TSPs</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dd51871a-763e-4de8-9c29-793c326b63df</guid>
        <pubDate>2025-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.1] - 2025-06-18</h4>
<p>New minor release with improvement in installation process. &nbsp;</p>
<h3>New features</h3>
<ul>
<li>Introduced iE BSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS runtimes v3.5.18.40, PCM2.1, PCM3.3 and PCM6.2</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1, added selection of terminations for CAN ports</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b9a78b87-f3e9-441b-a5e0-6c95754dd80d</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.&nbsp;</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK. &nbsp;</li>
<li>Fixes an issue where it was not possible to set Port mode to RSTP External.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f51f667-807e-4968-ab1a-d71d0c1dc2d7</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where it was not possible to back up and restore user management</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bb8a699c-9a1a-4e17-a73d-feaee835a74b</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h4>2.0.16.1</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System to v3.5.21.40.</li>
<li>Added MIO2.1 devdesc v1.1.0.0, revision = 16#01010000.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Get serial number from BSP API</li>
</ul>
<h4>2.0.15.1</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the Modbus TCP default port (502) was blocked by the firewall.</li>
</ul>
<h4>2.0.15.0</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue in WebConfig where the user could accidentally press Apply multiple times when configuring the network.</li>
</ul>
<h4>2.0.14.1</h4>
<p>Minor release with cybersecurity-related improvement.</p>
<h3>Improvements</h3>
<ul>
<li>Corrected authentication issue.</li>
</ul>
<h4>2.0.14.0</h4>
<h3>This bundle includes:</h3>
<ul>
<li>Upgrade to CODESYS Runtime System version 3.5.21.10 (SP21 Patch 10).</li>
<li>Added NAMUR NE43 support on iE 650 PLC Analogue Inputs.</li>
<li>Improvements to user login and password validation.</li>
<li>Enhancements to the system log in WebConfig.</li>
</ul>
<h3>Improvements</h3>
<ul>
<li>WebConfig: Automatic logout message displayed upon failure.</li>
<li>WebConfig: Password confirmation required during input.</li>
<li>Corrected issue where the bootloader was not consistently updated.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>WebConfig: Resolved issue where the log was being filled with its own log messages.</li>
<li>WebConfig: Software version is now shown after login.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>WebConfig: Added list of open-source licences.</li>
<li>BSP: Updated splash screen and upgraded to CODESYS Runtime System version 3.5.21.10.</li>
<li>IO: Updated firmware for IOM3.2, IOM3.3, and IOM3.4 to version 1.0.0.4 (see dedicated change log).</li>
<li>IO: Updated firmware for AIM6·1, AIM6·2, AIO6·1, AIO6·2, and AOM6·2 to version 1.4.0.0 (see dedicated change log).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.16.3</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-16-3/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1da2dfce-df27-4878-a5e2-ad48daf6d940</guid>
        <pubDate>2026-03-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.16.3</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>CODESYS OPC UA Server closed channels unexpectedly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 PLC &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-plc/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bbd2e3a2-2f71-451e-b85e-6694943c959d</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 PLC</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added a workaround to prevent the CODESYS OPC UA server from stopping parameters unexpectedly.</li>
<li>Added an additional check to ensure that a valid default administrator user exists after a factory reset.</li>
<li>Added RSTP support, so swapping between RSTP network switches now works in a running system.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the administrator user was not present after a factory reset.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9ff3ab41-de47-4d97-8f65-15e8882d07ed</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.2.0</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p><strong>Initial release of the iE 650 PLC</strong></p>
<p>The iE 650 PLC embodies a robust, adaptable, and modular programmable controller ideal for crafting forward-looking intelligent energy management systems.&nbsp;<br>With its comprehensive suite of features, this PLC caters to the needs of designers, installers, and operators with ease.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">094faeb8-777c-4172-b917-41158325fe7f</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.4.0</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Performance and stability improvements.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ed0c5b56-2960-411d-8b74-58be58aa7f69</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p>This release includes general improvements to the iE PLC family.&nbsp;</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port when not in use.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>&nbsp;Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: Is is now possible to press Info when the search filter is highlighted.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40.&nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6e20f57c-5d66-405a-8214-dc6c781105c5</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h2>&nbsp;[2.0.8.1] - 2025-02-06</h2>
<h3>Changes</h3>
<ul>
<li>Fixed issue where EtherCAT master service is not enabled or disabled as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">12712864-4a16-462a-bee4-b079511a66f0</guid>
        <pubDate>2025-05-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>Updates to CODESYS SP support, packaging and libraries.</h4>
<h3>New Features</h3>
<ul>
<li>TSP packages are now signed</li>
<li>Added IOM33 devdesc 1.0.0.2, Revision=16#01000003</li>
<li>Added IOM33 devdesc 1.0.0.4, Revision=16#01000004</li>
<li>iEBSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Support for CODESYS runtimes v3.5.18.40 removed PCM21, PCM33 and PCM62</li>
<li>Merged TSP packages for PCM21, PCM33 and PCM62 into one .package file</li>
<li>Update DEIF_SysUtil_PCM61 to v1.0.0.1. Added selection of termination for CAN ports</li>
<li>Modbus RTU, removed Pcm51Clib dependency, Modbus RTU is not included in TSPs</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e69f49d-12ce-4fae-ae25-bcda854e7a56</guid>
        <pubDate>2025-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.1] - 2025-06-18</h4>
<p>New minor release with improvement in installation process. &nbsp;</p>
<h3>New features</h3>
<ul>
<li>Introduced iE BSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS runtimes v3.5.18.40, PCM2.1, PCM3.3 and PCM6.2</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1, added selection of terminations for CAN ports</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d7f1030c-ff07-48ce-89f7-cb6f69ef4c21</guid>
        <pubDate>2025-07-14T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.&nbsp;</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">936edd4e-5950-4845-b8a1-c559f4e9f99f</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where it was not possible to back up and restore user management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">03524e09-cc22-4101-a889-f4af890e03a7</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>2.0.16.1</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System to v3.5.21.40.</li>
<li>Added MIO2.1 devdesc v1.1.0.0, revision = 16#01010000.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Get serial number from BSP API</li>
</ul>
<h4>2.0.15.1</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the Modbus TCP default port (502) was blocked by the firewall.</li>
</ul>
<h4>2.0.15.0</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue in WebConfig where the user could accidentally press Apply multiple times when configuring the network.</li>
</ul>
<h4>2.0.14.1</h4>
<p>Minor release with cybersecurity-related improvement.</p>
<h3>Improvements</h3>
<ul>
<li>Corrected authentication issue.</li>
</ul>
<h4>2.0.14.0</h4>
<h3>This bundle includes:</h3>
<ul>
<li>Upgrade to CODESYS Runtime System version 3.5.21.10 (SP21 Patch 10).</li>
<li>Added NAMUR NE43 support on iE 650 PLC Analogue Inputs.</li>
<li>Improvements to user login and password validation.</li>
<li>Enhancements to the system log in WebConfig.</li>
</ul>
<h3>Improvements</h3>
<ul>
<li>WebConfig: Automatic logout message displayed upon failure.</li>
<li>WebConfig: Password confirmation required during input.</li>
<li>Corrected issue where the bootloader was not consistently updated.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>WebConfig: Resolved issue where the log was being filled with its own log messages.</li>
<li>WebConfig: Software version is now shown after login.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>WebConfig: Added list of open-source licences.</li>
<li>BSP: Updated splash screen and upgraded to CODESYS Runtime System version 3.5.21.10.</li>
<li>IO: Updated firmware for IOM3.2, IOM3.3, and IOM3.4 to version 1.0.0.4 (see dedicated change log).</li>
<li>IO: Updated firmware for AIM6·1, AIM6·2, AIO6·1, AIO6·2, and AOM6·2 to version 1.4.0.0 (see dedicated change log).</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 PLC &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-plc/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3cb6e9af-27e9-4301-b854-aad825808cb1</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 PLC</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added a workaround to prevent the CODESYS OPC UA server from stopping parameters unexpectedly.</li>
<li>Added an additional check to ensure that a valid default administrator user exists after a factory reset.</li>
<li>Added RSTP support, so swapping between RSTP network switches now works in a running system.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the administrator user was not present after a factory reset.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS run-time (SP19 Patch 60) &#x2013; v1.3.0.18</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-run-time-sp19-patch-60/1-3-0-18/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f7f5e4ec-ca4f-4185-9cb3-92f7c15ce00b</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS run-time (SP19 Patch 60)</category>
        <category domain="version">1.3.0.18</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<h3>Release of CODESYS runtime v3.5SP19p60</h3>
<p><strong>[1.3.0.18] - 2024-06-10</strong></p>
<p><strong>Added</strong><br>- Updated CmpXml2 to v3.5.15.1.</p>
<p><strong>Corrections</strong><br>- Fixed issue using CmpXml2 component on PCM6.2.<br>- Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</p>
<p>&nbsp;</p>
<p><strong>1.3.0.17] - 2024-05-15</strong></p>
<p><strong>Added</strong><br>- Added buildinfo manual step.<br>&nbsp;<br><strong>Corrections</strong></p>
<p><br><strong>1.3.0.16] - 2024-05-08&nbsp;</strong></p>
<p><strong>Added</strong><br>- Enforce HTTPS on webvisu.<br>- Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.<br>- Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.<br>- Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.<br>- Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</p>
<p><br><strong>Corrections</strong></p>
<p><br><strong>[1.3.0.15] - 2024-04-22&nbsp;</strong></p>
<p><strong>Added</strong><br>- Enable enforce user management on all targets.<br>- Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.<br>- Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</p>
<p>Corrections</p>
<p><br><strong>[1.3.0.14] - 2024-02-29&nbsp;</strong></p>
<p><strong>Added</strong><br>- Added CODESYS runtime 3.5.19.60.</p>
<p>Corrections</p>
<p><br><strong>[1.3.0.13] - 2024-01-31</strong><br>- Do not start CODESYS if licence is missing.<br>- Off by one.</p>
<p><strong>[1.3.0.12] - 2024-01-35</strong><br>- HF release from branch</p>
<p><strong>[1.3.0.11] - 2024-01-25</strong><br>- Do not start CODESYS if licence is missing.</p>
<p><strong>[1.3.0.10] - 2024-01-04</strong></p>
<p>Added<br>- Updated ACM31 devdesc to v5.1.0.0.<br>- Updated IOM32 devdesc to v1.0.0.4.<br>- Added LibModbus version 1.1.0.6. Fixed connection return value truncated to 0.<br>- Added CODESYS supplement for licences on iMX8.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 CODESYS TSP (SP19 Patch 60) &#x2013; v1.3.0.18</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-codesys-tsp-sp19-patch-60/1-3-0-18/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">404fd347-c964-4350-9555-5cc9a412000f</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 CODESYS TSP (SP19 Patch 60)</category>
        <category domain="version">1.3.0.18</category>
          <category domain="release-status">current</category>
        <content:encoded><![CDATA[
<h3>Release of CODESYS &nbsp;TSP v1.3.0.18</h3>
<p><br><strong>[1.3.0.18] - 2024-06-1</strong>0<br>Added<br>- Updated CmpXml2 to v3.5.15.1.</p>
<p>Corrections<br>- Fixed issue using CmpXml2 component on PCM6.2.<br>- Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</p>
<p><strong>1.3.0.17] - 2024-05-15</strong><br>Added<br>- Added buildinfo manual step.<br>&nbsp;<br>Corrections</p>
<p><br><strong>1.3.0.16] - 2024-05-08&nbsp;</strong><br>Added<br>- Enforce HTTPS on webvisu.<br>- Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.<br>- Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.<br>- Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.<br>- Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</p>
<p><br>Corrections</p>
<p><br><strong>[1.3.0.15] - 2024-04-22&nbsp;</strong><br>Added<br>- Enable enforce user management on all targets.<br>- Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.<br>- Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</p>
<p>Corrections</p>
<p><br><strong>[1.3.0.14] - 2024-02-29&nbsp;</strong><br>Added<br>- Added CODESYS runtime 3.5.19.60.</p>
<p>Corrections</p>
<p><br><strong>[1.3.0.13] - 2024-01-31</strong><br>- Do not start CODESYS if licence is missing.<br>- Off by one.</p>
<p><strong>[1.3.0.12] - 2024-01-35</strong><br>- HF release from branch</p>
<p><strong>[1.3.0.11] - 2024-01-25</strong><br>- Do not start CODESYS if licence is missing.</p>
<p><strong>[1.3.0.10] - 2024-01-04</strong></p>
<p>Added<br>- Updated ACM31 devdesc to v5.1.0.0.<br>- Updated IOM32 devdesc to v1.0.0.4.<br>- Added LibModbus version 1.1.0.6. Fixed connection return value truncated to 0.<br>- Added CODESYS supplement for licences on iMX8.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.4.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-4-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">132d43ec-fe58-43be-9a1f-4af7b6cc3932</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.4.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<p><strong>Initial Release of the iE 250 Marine.</strong></p>
<p>The iE 250 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation.&nbsp;</p>
<p>The iE 250 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications.&nbsp;</p>
<p>This software package is intended to serve the CORE level functionality.</p>
<p>Minimum required version of PICUS: <strong>1.0.22.0</strong></p>
<h3>New features</h3>
<ul>
<li>An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Computer Security Log Management requirements.</li>
<li>Updated Volvo EMS2.4 to support ACM module.</li>
<li>Added support for CAT C7.1.</li>
<li>EIC: Added support for Kohler KDI3404.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed default value for the regulator status text.</li>
<li>Added support for adjusting the brightness level on the controller.</li>
<li>Fixed visibility of ECU and CAN parameters.</li>
<li>Fixed issue where Custom Logic was missing.</li>
<li>Fixed issue where the licence error alarm could occur after a restore from a backup.</li>
<li>Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.</li>
<li>Fixed issue where disclaimer was incorrectly shown.</li>
</ul>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5a121357-2f66-4e37-8a5e-1441e55810a0</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.4.1</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: It is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40.&nbsp;</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue cause Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1573cfbd-c7eb-4ef7-b172-af4021b2a80e</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue that sometimes prevents start-up of controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improved wire break detection handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b7a14c8f-2742-4cf3-ae90-2330c44f54fc</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be set up to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to use in the flexible Modbus.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350 &nbsp;</li>
<li>Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.</li>
<li>Added write permission for "Priorities" when the controller is in emulation.</li>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control". &nbsp;</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation. &nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI were not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups could not be collapsed using touch.</li>
<li>Fixed issue where iE 250 failed to start up without MIO module.</li>
<li>Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.</li>
<li>Fixed issue where the display user could not clear DM2 logs.</li>
<li>Fixed issue where the iE controller could not start without MIO module.&nbsp;</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where the user could enter parameter values outside of valid range.</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Fixed issue where PIM2.1 DIO levels were inverted.</li>
<li>Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms.&nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS were hidden in IO configuration.</li>
<li>Fixed issue where PWM was not working on MIO2.1.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f0d967bc-c233-425f-bb10-2ec1ad0aefe9</guid>
        <pubDate>2025-06-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.10.1 based on 2.0.9.0</h4>
<h3>New features</h3>
<ul>
<li>The user can now read the device serial number in CODESYS</li>
</ul>
<h3>&nbsp;Corrections</h3>
<ul>
<li>Opening I/Os in a backup or config file no longer results in an error popup</li>
<li>Fixed issue with fieldbus connections handling that prevented correct connections from being displayed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c5643e3d-6a54-4f28-b8c9-cb7ea415aa2a</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
<li>Fixed an issue where using external breaker feedbacks could cause incorrect power management behaviour.</li>
<li>Fixed an issue where external and redundant breaker feedback could result in an incorrect breaker position state.</li>
<li>Dynamic Section Status is now available again in CODESYS Development System.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9d8c09b1-8574-4b55-87dc-c345ce4962ae</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>&nbsp;Fixed issue where it was not possible to back up and restore user management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8d44e771-7abb-4027-8ab7-046e2b66788d</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added new average system frequency measurement.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>iE250: Fixed issue where a custom name for an I/O on the controller would also name an I/O on an IOM3.1 module.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Changed custom logic so the CB configuration failure alarm does not appear.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1e7bd07e-bb74-4fca-af41-9a915b1a3532</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.1 (based on version 2.0.15.0)</h4>
<h3>New feature</h3>
<ul>
<li>EtherCAT® performance improvements, enhancing communication between PCM2.1 and extension racks.</li>
</ul>
<h3>Correction</h3>
<ul>
<li>Fixed an issue where the selected display header did not remain active after a power cycle of the controller.</li>
<li>Fixed an issue which caused controller to restart if user did not take action</li>
</ul>
<h4>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4><br>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes</h3>
<ul>
<li>Architectural updates in preparation for new power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the bootloader was not updating correctly.</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 from operating, causing a System Not OK alarm.</li>
<li>Fixed an issue with GAM3.2 configuration when in stand-alone mode for analogue regulation.</li>
<li>Fixed an issue with synchronisation visualisation.</li>
<li>Fixed an issue where permissions were missing after a backup/restore cycle.</li>
<li>Fixed an issue affecting the performance of analogue regulation on the analogue bidirectional I/O terminals.</li>
<li>Fixed an issue with the logout message in WebConfig.</li>
<li>Fixed an issue with the new password error in User Management.</li>
<li>Fixed an issue where spurious information was occupying log entries, making it harder to see valid entries.</li>
<li>Fixed an issue where Chinese characters were not displayed correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.16.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-16-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">667fa807-5097-4f72-becc-90d4307ce4ef</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.16.2</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where restoring an older backup on version 2.0.15.0 or newer prevented logging in to the controller from the CODESYS IDE.</li>
<li>Fixed an issue where it was not possible to select imperial units on the controller.</li>
<li>Fixed an issue that allowed the controller variant check to be overridden during backup restoration.</li>
<li>Fixed an issue where backups over 50 MB could not be restored to the controller.</li>
<li>Fixed an issue where it was not possible to log in to the controller after a factory reset.</li>
<li>EIC: Fixed missing SAE J1939 SPN texts for DM1 and DM2 alarms.</li>
<li>EIC: Fixed missing measurement for engine oil-filter differential pressure.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">13e914d5-0fcb-4207-953d-1c7c1d3feda9</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present after a factory reset.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Added RSTP support, enabling switching between RSTP switches in a running system.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated the I/O configuration experience for iE 250 controller AIOs.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user was not present after a factory reset.</li>
<li>Resolved an issue that prevented the emulation engine from starting after a previously configured start failure.</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Fixed a defect in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
<li>Corrected incorrect source addressing for TSC1 and CM1 for FPT / Iveco Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.4.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-4-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e84fe9a4-4add-48c7-b9da-ef6fed37b2d9</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.4.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<p><strong>Initial release of the iE 250 Marine.</strong></p>
<p>The iE 250 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation.&nbsp;</p>
<p>The iE 250 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications.&nbsp;</p>
<p>This software package is intended to serve the POWER MANAGEMENT level functionality.</p>
<p>Minimum required version of PICUS: <strong>1.0.22.0</strong></p>
<h3>New features</h3>
<ul>
<li>An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Computer Security Log Management requirements.</li>
<li>Updated Volvo EMS2.4 to support ACM module.</li>
<li>Added support for CAT C7.1.</li>
<li>EIC: Added support for Kohler KDI3404.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed default value for the regulator status text.</li>
<li>Added support for adjusting the brightness level on the controller.</li>
<li>Fixed visibility of ECU and CAN parameters.</li>
<li>Fixed issue where Custom Logic was missing.</li>
<li>Fixed issue where the licence error alarm could occur after a restore from a backup.</li>
<li>Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.</li>
<li>Fixed issue where disclaimer was incorrectly shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5d2baddf-2c37-4415-95ad-8c3cb37adc1d</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.4.1</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added &nbsp;Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: It is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40.&nbsp;</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue cause Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9deed5ce-1d3e-4925-9679-fc62270a30fe</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue that sometimes prevents start-up of controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improved wire break detection handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3fb0122f-d5a2-4e39-891f-130e4b545e1e</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be set up to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to use in the flexible Modbus. &nbsp;</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350. &nbsp;&nbsp;</li>
<li>Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.</li>
<li>Added write permission for "Priorities" when the controller is in emulation.</li>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control". &nbsp;</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation. &nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI were not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups could not be collapsed using touch.</li>
<li>Fixed issue where iE 250 failed to start up without MIO module.</li>
<li>Fixed issue where configuring a Modbus value to "true", made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.</li>
<li>Fixed issue where the display user could not clear DM2 logs.</li>
<li>Fix issue where the iE controller could not start without MIO module.&nbsp;</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where the user could enter parameter values outside of valid range.</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Corrected issue where the controller restarts due to heavy consumers.</li>
<li>Fixed issue where PIM2.1 DIO levels were inverted.</li>
<li>Fixed issue where removing the network cable would activate system NOK, IO service error and "temperature too high" alarms.&nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS were hidden in the IO configuration.</li>
<li>Fixed issue where "Block blackout start" input was also blocking manual close of the breaker during blackout.</li>
<li>Fixed issue where PWM was not working on MIO2.1.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b7f656e2-2933-4534-9f17-9d7d02d7acf2</guid>
        <pubDate>2025-06-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.10.1 based on 2.0.9.0</h4>
<h3>New features:</h3>
<ul>
<li>The user can now read the device serial number in CODESYS</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Opening I/Os in a backup or config file no longer results in an error popup</li>
<li>Fixed issue with fieldbus connection handling that prevented correct connections from being displayed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a9108497-967d-4c97-8344-fb9b1397bd99</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
<li>Fixed an issue where using external breaker feedbacks could cause incorrect power management behaviour.</li>
<li>Fixed an issue where external and redundant breaker feedback could result in an incorrect breaker position state.</li>
<li>Dynamic Section Status is now available again in CODESYS Development System.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e5e736eb-a10a-4fc5-af29-94e778b2c681</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>&nbsp;Fixed issue where it was not possible to back up and restore user management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">40d71e63-11ff-4a93-867f-88edddf5c5b5</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added new average system frequency measurement.</li>
<li>Added possibility to select the range impact of switchboard control when an alarm occurs on a controller.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added texts for heavy consumer request, load ON and load OFF events in emulation.</li>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>iE250: Fixed issue where a custom name for an I/O on the controller would also name an I/O on an IOM3.1 module.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Changed custom logic so the CB configuration failure alarm does not appear.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Fixed issue where emergency genset would interpret the busbar as dead and refuse to synchronise the tiebreaker.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ae148bcc-b782-4c46-88f6-824acabeac06</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.1 (based on version 2.0.15.0)</h4>
<h3>New feature</h3>
<ul>
<li>EtherCAT® performance improvements, enhancing communication between PCM2.1 and extension racks.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where SG and SC continued in a loop when synchronisation was cancelled.<br>Fixed an issue where the selected display header did not remain active after a power cycle of the controller.</li>
<li>Fixed an issue which caused controller to restart if user did not take action</li>
<li>Fixed an issue where asymmetric load sharing shared equally rather than according to percentages.</li>
</ul>
<h4>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes</h3>
<ul>
<li>Architectural updates in preparation for new power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the bootloader was not updating correctly.</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 from operating, causing a System Not OK alarm.</li>
<li>Fixed an issue with GAM3.2 configuration when in stand-alone mode for analogue regulation.</li>
<li>Fixed an issue with synchronisation visualisation.</li>
<li>Fixed an issue where permissions were missing after a backup/restore cycle.</li>
<li>Fixed an issue affecting the performance of analogue regulation on the analogue bidirectional I/O terminals.</li>
<li>Fixed an issue with the logout message in WebConfig.</li>
<li>Fixed an issue with the new password error in User Management.</li>
<li>Fixed an issue where spurious information was occupying log entries, making it harder to see valid entries.</li>
<li>Fixed an issue where Chinese characters were not displayed correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Marine application SW (Power Management) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-marine-pm/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">942c69d1-41f5-45a0-b70f-937009a6e365</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Marine application SW (Power Management)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present after a factory reset.</li>
<li>Added missing measurement SPN 6321.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Expanded diagnostic message support with all valid SAE J1939 SPN texts for DM1 and DM2 alarm descriptions.</li>
<li>Added RSTP support, enabling switching between RSTP switches in a running system.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated the I/O configuration experience for iE 250 controller AIOs.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user was not present after a factory reset.</li>
<li>Resolved an issue that prevented the emulation engine from starting after a previously configured start failure.</li>
<li>Fixed a defect that allowed controller variant checks to be overridden during backup restore.</li>
<li>Fixed a defect where restoring older backups on version 2.0.15.0 or newer could block login to the controller from the CODESYS Development System.</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed backup restore failures for backups larger than 50 MB.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Fixed a defect in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
<li>Corrected incorrect source addressing for TSC1 and CM1 for FPT / Iveco Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.4.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-4-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">37f29101-1cf8-4003-bd80-ca17ce4631aa</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.4.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<p><strong>Initial release of the iE 350 Marine.</strong></p>
<p>The iE 350 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation.&nbsp;</p>
<p>The iE 350 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications.&nbsp;</p>
<p>This software package is intended to serve the CORE level functionality.</p>
<p>Minimum required version of PICUS: <strong>1.0.22.0</strong></p>
<h3>New features</h3>
<ul>
<li>An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Computer Security Log Management requirements.</li>
<li>Updated Volvo EMS2.4 to support ACM module.</li>
<li>Added support for CAT C7.1.</li>
<li>EIC: Added support for Kohler KDI3404.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed default value for the regulator status text.</li>
<li>Added support for adjusting the brightness level on the controller.</li>
<li>Fixed visibility of ECU and CAN parameters.</li>
<li>Fixed issue where Custom Logic was missing.</li>
<li>Fixed issue where the licence error alarm could occur after a restore from a backup.</li>
<li>Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.</li>
<li>Fixed issue where disclaimer was incorrectly shown.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f2ea4391-5fc8-40b7-b97c-6f7d22fd73df</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.4.1</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: Is is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40&nbsp;</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue causing Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">eae29c0b-9a49-449d-bd0f-773f745acc15</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue that sometimes prevents start-up of controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improved wire break detection handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">295740af-3f8e-4c06-a8d8-6c635ae4f1e5</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be set up to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to use in the flexible Modbus. &nbsp;</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.</li>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350.&nbsp;</li>
<li>Added write permission for "Priorities" when the controller is in emulation.</li>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control". &nbsp;</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation. &nbsp;&nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI were not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups could not be collapsed using touch.</li>
<li>Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs were not shown in the UI for e.g. configuring alarms.</li>
<li>Fixed issue where the display user could not clear DM2 logs.</li>
<li>Fixed issue where the iE controller could not start without MIO module.</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where the user could enter parameter values outside of the valid range.</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Fixed issue where removing the network cable would activate system NOK, IO service error and "temperature too high" alarms.&nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS were hidden in IO configuration.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c77e1a35-7691-4d55-b000-f93c0c6094e9</guid>
        <pubDate>2025-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.1] - 2025-06-18</h4>
<p>New minor release with improvement in installation process. &nbsp;</p>
<h3>New features</h3>
<ul>
<li>Introduced iE BSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS runtimes v3.5.18.40, PCM2.1, PCM3.3 and PCM6.2</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1, added selection of terminations for CAN ports</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7c0781ee-f340-400a-ae99-6828914799c6</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
<li>Fixed an issue where using external breaker feedbacks could cause incorrect power management behaviour.</li>
<li>Fixed an issue where external and redundant breaker feedback could result in an incorrect breaker position state.</li>
<li>Dynamic Section Status is now available again in CODESYS Development System.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ffeca287-66bf-4cff-b32c-e79198ab2bf4</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where it was not possible to back up and restore user management</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ead44e3f-a543-49de-907d-7ea345894c44</guid>
        <pubDate>2025-10-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added new average system frequency measurement.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>iE250: Fixed issue where a custom name for an I/O on the controller would also name an I/O on an IOM3.1 module.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Changed custom logic so the CB configuration failure alarm does not appear.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">345897a1-0be0-46aa-a007-f38f9ce25ab6</guid>
        <pubDate>2026-01-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.16.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.0 (based on version 2.0.15.0)</h4>
<h3>New feature</h3>
<ul>
<li>EtherCAT® performance improvements, enhancing communication between PCM3.3, modules, and extension racks.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue with the display header.</li>
<li>Fixed an issue with GAM3.2 regulation.</li>
</ul>
<h4>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes</h3>
<ul>
<li>Architectural updates in preparation for new power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the bootloader was not updating correctly.</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 from operating, causing a System Not OK alarm.</li>
<li>Fixed an issue with GAM3.2 configuration when in stand-alone mode for analogue regulation.</li>
<li>Fixed an issue with synchronisation visualisation.</li>
<li>Fixed an issue where permissions were missing after a backup/restore cycle.</li>
<li>Fixed an issue affecting the performance of analogue regulation on the analogue bidirectional I/O terminals.</li>
<li>Fixed an issue with the logout message in WebConfig.</li>
<li>Fixed an issue with the new password error in User Management.</li>
<li>Fixed an issue where spurious information was occupying log entries, making it harder to see valid entries.</li>
<li>Fixed an issue where Chinese characters were not displayed correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">047909f6-883e-471b-9ca9-f194d01a9218</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Correction</h3>
<ul>
<li>Fixed an issue that caused the controller to restart if the user did not take action.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.16.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-16-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f3621d3a-5cb5-41b2-a253-504fc9468459</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.16.2</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where restoring an older backup on version 2.0.15.0 or newer prevented logging in to the controller from the CODESYS IDE.</li>
<li>Fixed an issue where it was not possible to select imperial units on the controller.</li>
<li>Fixed an issue that allowed the controller variant check to be overridden during backup restoration.</li>
<li>Fixed an issue where backups over 50 MB could not be restored to the controller.</li>
<li>Fixed an issue where it was not possible to log in to the controller after a factory reset.</li>
<li>EIC: Fixed missing SAE J1939 SPN texts for DM1 and DM2 alarms.</li>
<li>EIC: Fixed missing measurement for engine oil-filter differential pressure.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Protection &amp; Paralleling) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1a49c8b5-e8f5-4a70-98d4-2929b6652fa9</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Protection &amp; Paralleling)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present after a factory reset.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Added RSTP support, enabling switching between RSTP switches in a running system.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user was not present after a factory reset.</li>
<li>Resolved an issue that prevented the emulation engine from starting after a previously configured start failure.</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Fixed a defect in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.4.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-4-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d8598246-c03d-47dd-8ebc-f0d48f4cda85</guid>
        <pubDate>2024-07-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.4.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<p><strong>Initial release of the iE 350 Marine.</strong></p>
<p>The iE 350 Marine, our next-generation controller product line for the maritime segment, features an award-winning design ensuring intuitive and efficient operation.&nbsp;</p>
<p>The iE 350 Marine exceeds IACS UR E27 cybersecurity regulations, providing robust protection against cyber threats. Engineered for superior performance and reliability, it meets the rigorous demands of modern maritime applications.&nbsp;</p>
<p>This software package is intended to serve the POWER MANAGEMENT level functionality.</p>
<p>Minimum required version of PICUS: <strong>1.0.22.0</strong></p>
<h3>New features</h3>
<ul>
<li>An alarm has been added to inform the customer if the log system on the controller has been damaged or is in any other way malfunctioning. This is done to comply with Computer Security Log Management requirements.</li>
<li>Updated Volvo EMS2.4 to support ACM module.</li>
<li>Added support for CAT C7.1.</li>
<li>EIC: Added support for Kohler KDI3404.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed default value for the regulator status text.</li>
<li>Added support for adjusting the brightness level on the controller.</li>
<li>Fixed visibility of ECU and CAN parameters.</li>
<li>Fixed issue where Custom Logic was missing.</li>
<li>Fixed issue where the licence error alarm could occur after a restore from a backup.</li>
<li>Name of Modbus protocols, as seen in PICUS, now includes both type and variant, rather than only type. For example, 'Single Genset GB MB' rather than only 'Single Genset'.</li>
<li>Fixed issue where disclaimer was incorrectly shown.</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e35f335f-2e42-4750-bb15-50ae30404b11</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.4.1</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: Is is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40 .</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue causing Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b82c5d44-7f10-4dbb-a53e-8fe2ac0e2a71</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue that sometimes prevents start-up of controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improved wire break detection handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4e266ea9-54d8-498d-accd-a5b7e9cbc00f</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be setup to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to be used in the flexible Modbus.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350.&nbsp;</li>
<li>Number of possible Modbus connections changed from 20 to 100 on iE2 50 and iE 350.</li>
<li>Added write permission for "Priorities" when controller is in emulation.</li>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control". &nbsp;</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation. &nbsp;&nbsp;</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI are not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups can't be collapsed using touch.</li>
<li>Fixed issue where configuring a modbus value to "true" made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs are not shown in UI for e.g. configuring alarms.</li>
<li>Fixed issue where display user cannot clear DM2 logs.</li>
<li>Fixed issue where IE controller cannot start without an MIO module.&nbsp;</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where user can enter parameter values outside of valid range.</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Fixed issue where controller restarts due to heavy consumers.</li>
<li>Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms.&nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS was hidden in IO configuration.</li>
<li>Fixed issue where "Block blackout start" input was also blocking "manual close" of breaker during blackout.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">dfee5ec4-d86c-4ccb-8358-ac52593f03f6</guid>
        <pubDate>2025-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>2.0.10.1 based on 2.0.9.0</h4>
<h3>New features</h3>
<ul>
<li>Users can now read the device serial number in CODESYS</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Opening I/Os from a backup or config file no longer triggers an error pop-up</li>
<li>Resolved an issue with fieldbus connection handling that previously prevented correct connections from being displayed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">421f0d13-c7ea-40f2-80c1-999eb58feada</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
<li>Fixed an issue where using external breaker feedbacks could cause incorrect power management behaviour.</li>
<li>Fixed an issue where external and redundant breaker feedback could result in an incorrect breaker position state.</li>
<li>Dynamic Section Status is now available again in CODESYS Development System.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e607bc01-5937-4d5b-969d-e4e8228bb0df</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where it was not possible to back up and restore user management</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cb17f65e-3941-4785-a13a-aa2851009170</guid>
        <pubDate>2025-10-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added new average system frequency measurement.</li>
<li>Added possibility to select the range impact of switchboard control when an alarm occurs on a controller.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added texts for heavy consumer request, load ON and load OFF events in emulation.</li>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>iE250: Fixed issue where a custom name for an I/O on the controller would also name an I/O on an IOM3.1 module.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Changed custom logic so the CB configuration failure alarm does not appear.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Fixed issue where emergency genset would interpret the busbar as dead and refuse to synchronise the tiebreaker.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">63421006-6a56-465b-9d1e-14c6cba04e00</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.1 (based on version 2.0.15.0)</h4>
<h3>New feature</h3>
<ul>
<li>EtherCAT® performance improvements, enhancing communication between PCM3.3, modules, and extension racks.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where SG and SC continued in a loop when synchronisation was cancelled.</li>
<li>Fixed an issue where the selected display header did not remain active after a power cycle of the controller.</li>
<li>Fixed an issue which caused controller to restart if user did not take action</li>
<li>Fixed an issue where asymmetric load sharing shared equally rather than according to percentages.</li>
</ul>
<h4>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes</h3>
<ul>
<li>Architectural updates in preparation for new power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the bootloader was not updating correctly.</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 from operating, causing a System Not OK alarm.</li>
<li>Fixed an issue with GAM3.2 configuration when in stand-alone mode for analogue regulation.</li>
<li>Fixed an issue with synchronisation visualisation.</li>
<li>Fixed an issue where permissions were missing after a backup/restore cycle.</li>
<li>Fixed an issue affecting the performance of analogue regulation on the analogue bidirectional I/O terminals.</li>
<li>Fixed an issue with the logout message in WebConfig.</li>
<li>Fixed an issue with the new password error in User Management.</li>
<li>Fixed an issue where spurious information was occupying log entries, making it harder to see valid entries.</li>
<li>Fixed an issue where Chinese characters were not displayed correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Marine application SW (Power Management) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-marine-pm/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c2fe632a-e374-465c-af3c-2d83e4f3b053</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Marine application SW (Power Management)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 350 Marine</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present after a factory reset.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Added RSTP support, enabling switching between RSTP switches in a running system.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user was not present after a factory reset.</li>
<li>Resolved an issue that prevented the emulation engine from starting after a previously configured start failure.</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Fixed a defect in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
<li>Corrected incorrect source addressing for TSC1 and CM1 for FPT / Iveco Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR FW 210 series F &#x2013; v2.1.1.3-247</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-fw-210-series-f/2-1-1-3-247/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">10c02254-f7b1-4b18-ac51-1b8d85549868</guid>
        <pubDate>2025-01-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR FW 210 series F</category>
        <category domain="version">2.1.1.3-247</category>
          <category domain="release-status">current</category>
          <category domain="product">MVR-F201</category>
          <category domain="product">MVR-F205</category>
          <category domain="product">MVR-F210</category>
          <category domain="product">MVR-F215</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Parameter: Settable voltage measurement threshold.</li>
<li>HMI: Transformer module measurements added to mimic.</li>
<li>HMI: Imeas/Iset to I2&gt; function.</li>
<li>HMI: Kazakh, Chinese and Russian language translations.</li>
<li>Communication: Energy measurement mapping to IEC61850.</li>
<li>Communication: Scaled analog inputs to IEC104.</li>
<li>Communication: Voltage and current THD to IEC61850.</li>
<li>Communication: U3/U4 frequency to IEC61850 and Modbus.</li>
<li>Communication: CTS2 to IEC61850 mapping.</li>
<li>Communication: Programmable stages to IEC61850.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Synchrocheck [25]: Added LL/DL/LD/DD-mode, ability to select line or bus as reference, additional signals.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>mA output: Corrected mA output accuracy.</li>
<li>Frequent start FSP (N&gt;) [66]:Fixed issue where frequency start -stage was not working correctly.</li>
<li>AVR: Fixed issue where AVR scaling curve was not working correctly.</li>
<li>Communication: Fixed issues with IEC61850 Test outs (forced statuses) and events.</li>
<li>Directional overcurrent (Idir&gt;) [67]: Fixed issue where protection blocking signal reset start signal to zero.</li>
<li>HMI: Corrected language encoding.</li>
<li>Synchrocheck: Fixed issue where synchrocheck was not working correctly with maximum settings.</li>
<li>TrafoModule: Fixed issue where Manual Set vector group was not working correctly.</li>
<li>General: Improved USW connection termination.</li>
<li>General: Improved option card detection.</li>
<li>General: Fixed issue where device discovery announcement message had incorrect serial number.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR FW 210 series G &#x2013; v2.1.1.3-247</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-fw-210-series-g/2-1-1-3-247/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fd986707-0ec1-40b1-ab84-8cc7e618e03f</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR FW 210 series G</category>
        <category domain="version">2.1.1.3-247</category>
          <category domain="release-status">current</category>
          <category domain="product">MVR-G215</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Parameter: Settable voltage measurement threshold.</li>
<li>HMI: Transformer module measurements added to mimic.</li>
<li>HMI: Imeas/Iset to I2&gt; function.</li>
<li>HMI: Kazakh, Chinese and Russian language translations.</li>
<li>Communication: Energy measurement mapping to IEC61850.</li>
<li>Communication: Scaled analog inputs to IEC104.</li>
<li>Communication: Voltage and current THD to IEC61850.</li>
<li>Communication: U3/U4 frequency to IEC61850 and Modbus.</li>
<li>Communication: CTS2 to IEC61850 mapping.</li>
<li>Communication: Programmable stages to IEC61850.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Synchrocheck [25]: Added LL/DL/LD/DD-mode, ability to select line or bus as reference, additional signals.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>mA output: Corrected mA output accuracy.</li>
<li>Frequent start FSP (N&gt;) [66]:Fixed issue where frequency start -stage was not working correctly.</li>
<li>AVR: Fixed issue where AVR scaling curve was not working correctly.</li>
<li>Communication: Fixed issues with IEC61850 Test outs (forced statuses) and events.</li>
<li>Directional overcurrent (Idir&gt;) [67]: Fixed issue where protection blocking signal reset start signal to zero.</li>
<li>HMI: Corrected language encoding.</li>
<li>Synchrocheck: Fixed issue where synchrocheck was not working correctly with maximum settings.</li>
<li>TrafoModule: Fixed issue where Manual Set vector group was not working correctly.</li>
<li>General: Improved USW connection termination.</li>
<li>General: Improved option card detection.</li>
<li>General: Fixed issue where device discovery announcement message had incorrect serial number.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR FW 210 series M &#x2013; v2.1.1.3-247</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-fw-210-series-m/2-1-1-3-247/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fe86bf6e-33a0-4de4-a96b-9cb16f2de7ea</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR FW 210 series M</category>
        <category domain="version">2.1.1.3-247</category>
          <category domain="release-status">current</category>
          <category domain="product">MVR-M210</category>
          <category domain="product">MVR-M215</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Parameter: Settable voltage measurement threshold.</li>
<li>HMI: Transformer module measurements added to mimic.</li>
<li>HMI: Imeas/Iset to I2&gt; function.</li>
<li>HMI: Kazakh, Chinese and Russian language translations.</li>
<li>Communication: Energy measurement mapping to IEC61850.</li>
<li>Communication: Scaled analog inputs to IEC104.</li>
<li>Communication: Voltage and current THD to IEC61850.</li>
<li>Communication: U3/U4 frequency to IEC61850 and Modbus.</li>
<li>Communication: CTS2 to IEC61850 mapping.</li>
<li>Communication: Programmable stages to IEC61850.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Synchrocheck [25]: Added LL/DL/LD/DD-mode, ability to select line or bus as reference, additional signals.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>mA output: Corrected mA output accuracy.</li>
<li>Frequent start FSP (N&gt;) [66]:Fixed issue where frequency start -stage was not working correctly.</li>
<li>AVR: Fixed issue where AVR scaling curve was not working correctly.</li>
<li>Communication: Fixed issues with IEC61850 Test outs (forced statuses) and events.</li>
<li>Directional overcurrent (Idir&gt;) [67]: Fixed issue where protection blocking signal reset start signal to zero.</li>
<li>HMI: Corrected language encoding.</li>
<li>Synchrocheck: Fixed issue where synchrocheck was not working correctly with maximum settings.</li>
<li>TrafoModule: Fixed issue where Manual Set vector group was not working correctly.</li>
<li>General: Improved USW connection termination.</li>
<li>General: Improved option card detection.</li>
<li>General: Fixed issue where device discovery announcement message had incorrect serial number.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR FW 210 series T &#x2013; v2.1.1.3-247</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-fw-210-series-t/2-1-1-3-247/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">238c517a-30e0-42e9-bce7-f851c15d2d44</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR FW 210 series T</category>
        <category domain="version">2.1.1.3-247</category>
          <category domain="release-status">current</category>
          <category domain="product">MVR-T215</category>
          <category domain="product">MVR-T216</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Parameter: Settable voltage measurement threshold.</li>
<li>HMI: Transformer module measurements added to mimic.</li>
<li>HMI: Imeas/Iset to I2&gt; function.</li>
<li>HMI: Kazakh, Chinese and Russian language translations.</li>
<li>Communication: Energy measurement mapping to IEC61850.</li>
<li>Communication: Scaled analog inputs to IEC104.</li>
<li>Communication: Voltage and current THD to IEC61850.</li>
<li>Communication: U3/U4 frequency to IEC61850 and Modbus.</li>
<li>Communication: CTS2 to IEC61850 mapping.</li>
<li>Communication: Programmable stages to IEC61850.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Synchrocheck [25]: Added LL/DL/LD/DD-mode, ability to select line or bus as reference, additional signals.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>mA output: Corrected mA output accuracy.</li>
<li>Frequent start FSP (N&gt;) [66]:Fixed issue where frequency start -stage was not working correctly.</li>
<li>AVR: Fixed issue where AVR scaling curve was not working correctly.</li>
<li>Communication: Fixed issues with IEC61850 Test outs (forced statuses) and events.</li>
<li>Directional overcurrent (Idir&gt;) [67]: Fixed issue where protection blocking signal reset start signal to zero.</li>
<li>HMI: Corrected language encoding.</li>
<li>Synchrocheck: Fixed issue where synchrocheck was not working correctly with maximum settings.</li>
<li>TrafoModule: Fixed issue where Manual Set vector group was not working correctly.</li>
<li>General: Improved USW connection termination.</li>
<li>General: Improved option card detection.</li>
<li>General: Fixed issue where device discovery announcement message had incorrect serial number.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP19 Patch 60) &#x2013; v1.3.0.18</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp-sp19-patch-60/1-3-0-18/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">88fceb8e-c838-4404-889f-c446e3bd9800</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP19 Patch 60)</category>
        <category domain="version">1.3.0.18</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<p>Release of CODESYS runtime v3.5SP19p60 v1.3.0.18 for AMC 300 PCM3.1.</p>
<p>Note that the downloaded file will contain the TSP and code package.</p>
<h2>[1.3.0.18] - 2024-06-10</h2>
<h3>Added</h3>
<ul>
<li>Updated CmpXml2 to v3.5.15.1.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue using CmpXml2 component on PCM6.2.</li>
<li>Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</li>
</ul>
<h2>[1.3.0.17] - 2024-05-15</h2>
<h3>Added</h3>
<ul>
<li>Added buildinfo manual step.</li>
</ul>
<h2>[1.3.0.16] - 2024-05-08</h2>
<h3>Added</h3>
<ul>
<li>Enforce HTTPS on webvisu.</li>
<li>Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.</li>
<li>Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.</li>
<li>Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</li>
</ul>
<h2>[1.3.0.15] - 2024-04-22</h2>
<h3>Added</h3>
<ul>
<li>Enable enforce user management on all targets.</li>
<li>Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
<li>Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</li>
</ul>
<h2>[1.3.0.14] - 2024-02-29</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime 3.5.19.60.</li>
</ul>
<h2>[1.3.0.13] - 2024-01-31</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
<li>Off by one.</li>
</ul>
<h2>[1.3.0.12] - 2024-01-35</h2>
<ul>
<li>HF release from branch.</li>
</ul>
<h2>[1.3.0.11] - 2024-01-25</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
</ul>
<h2>[1.3.0.10] - 2024-01-04</h2>
<h3>Added</h3>
<ul>
<li>Updated ACM31 devdesc to v5.1.0.0.</li>
<li>Updated IOM32 devdesc to v1.0.0.4.</li>
<li>Added LibModbus version 1.1.0.6. Fix connection return value truncated to 0.</li>
<li>Added CODESYS supplement for licences on iMX8.</li>
</ul>
<h2>[1.3.0.9] - 2023-10-24</h2>
<h3>Added</h3>
<ul>
<li>Added iE BSP component.</li>
<li>Updated TIM61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated AIO61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated DIM61 devdesc to v1.0.0.0, revision 2.</li>
<li>Updated DOM61 devdesc to v1.0.0.0, revision 3.</li>
<li>Updated DIO61 devdesc to v1.0.1.0, revision 2.</li>
<li>Updated DIO62 devdesc to v1.0.0.0, revision 2.</li>
</ul>
<h2>[1.3.0.8] - 2023-07-07</h2>
<h3>Added</h3>
<ul>
<li>CODESYS OPC UA Server (SP18 and newer).</li>
<li>Updated IFM61 devdesc to v1.1.0.0, revision 9.</li>
<li>Updated CMM62 devdesc to v0.9.0.2, revision 2.</li>
<li>Updated SIM61 devdesc to v1.0.0.1, revision 2.</li>
<li>Updated SIM62 devdesc to v1.0.0.0, revision 2.</li>
<li>Updated SIM63 devdesc to v1.0.0.1, revision 2.</li>
<li>Added DOM61 devdesc to v0.2.0.0, revision 2.</li>
<li>Added DIM61 devdesc to v0.1.0.0, revision 1.</li>
<li>Added DIO62 devdesc to v0.1.0.0, revision 1.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Renamed CMM62 devdesc to v1.0.0.0 to v0.9.0.1, revision 1.</li>
<li>Fixed scan/copy all devices SIM6.2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP19 Patch 60) &#x2013; v1.3.0.18</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp19-patch-60/1-3-0-18/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">87097bdf-a7fd-4e98-b374-460ff3e72b10</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP19 Patch 60)</category>
        <category domain="version">1.3.0.18</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Release of CODESYS runtime v3.5SP19p60 and TSP v1.3.0.18.</p>
<h2>[1.3.0.18] - 2024-06-10</h2>
<h3>Added</h3>
<ul>
<li>Updated CmpXml2 to v3.5.15.1.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue using CmpXml2 component on PCM6.2.</li>
<li>Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</li>
</ul>
<h2>[1.3.0.17] - 2024-05-15</h2>
<h3>Added</h3>
<ul>
<li>Added buildinfo manual step.</li>
</ul>
<h2>[1.3.0.16] - 2024-05-08</h2>
<h3>Added</h3>
<ul>
<li>Enforce HTTPS on webvisu.</li>
<li>Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.</li>
<li>Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.</li>
<li>Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</li>
</ul>
<h2>[1.3.0.15] - 2024-04-22</h2>
<h3>Added</h3>
<ul>
<li>Enable enforce user management on all targets.</li>
<li>Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
<li>Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</li>
</ul>
<h2>[1.3.0.14] - 2024-02-29</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime 3.5.19.60.</li>
</ul>
<h2>[1.3.0.13] - 2024-01-31</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
<li>Off by one.</li>
</ul>
<h2>[1.3.0.12] - 2024-01-35</h2>
<ul>
<li>HF release from branch.</li>
</ul>
<h2>[1.3.0.11] - 2024-01-25</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
</ul>
<h2>[1.3.0.10] - 2024-01-04</h2>
<h3>Added</h3>
<ul>
<li>Updated ACM31 devdesc to v5.1.0.0.</li>
<li>Updated IOM32 devdesc to v1.0.0.4.</li>
<li>Added LibModbus version 1.1.0.6. Fix connection return value truncated to 0.</li>
<li>Added CODESYS supplement for licences on iMX8.</li>
</ul>
<h2>[1.3.0.9] - 2023-10-24</h2>
<h3>Added</h3>
<ul>
<li>Added iE BSP component.</li>
<li>Updated TIM61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated AIO61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated DIM61 devdesc to v1.0.0.0, revision 2.</li>
<li>Updated DOM61 devdesc to v1.0.0.0, revision 3.</li>
<li>Updated DIO61 devdesc to v1.0.1.0, revision 2.</li>
<li>Updated DIO62 devdesc to v1.0.0.0, revision 2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP19 Patch 60) &#x2013; v1.3.0.18</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp19-patch-60/1-3-0-18/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b267affd-db63-4ef0-a50f-ca88bacbff96</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP19 Patch 60)</category>
        <category domain="version">1.3.0.18</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<p>Release of CODESYS runtime v3.5SP19p60 and TSP v1.3.0.18.</p>
<h2>[1.3.0.18] - 2024-06-10</h2>
<h3>Added</h3>
<ul>
<li>Updated CmpXml2 to v3.5.15.1.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue using CmpXml2 component on PCM6.2.</li>
<li>Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</li>
</ul>
<h2>[1.3.0.17] - 2024-05-15</h2>
<h3>Added</h3>
<ul>
<li>Added buildinfo manual step.</li>
</ul>
<h2>[1.3.0.16] - 2024-05-08</h2>
<h3>Added</h3>
<ul>
<li>Enforce HTTPS on webvisu.</li>
<li>Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.</li>
<li>Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.</li>
<li>Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</li>
</ul>
<h2>[1.3.0.15] - 2024-04-22</h2>
<h3>Added</h3>
<ul>
<li>Enable enforce user management on all targets.</li>
<li>Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
<li>Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</li>
</ul>
<h2>[1.3.0.14] - 2024-02-29</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime 3.5.19.60.</li>
</ul>
<h2>[1.3.0.13] - 2024-01-31</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
<li>Off by one.</li>
</ul>
<h2>[1.3.0.12] - 2024-01-35</h2>
<ul>
<li>HF release from branch.</li>
</ul>
<h2>[1.3.0.11] - 2024-01-25</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
</ul>
<h2>[1.3.0.10] - 2024-01-04</h2>
<h3>Added</h3>
<ul>
<li>Updated ACM31 devdesc to v5.1.0.0.</li>
<li>Updated IOM32 devdesc to v1.0.0.4.</li>
<li>Added LibModbus version 1.1.0.6. Fix connection return value truncated to 0.</li>
<li>Added CODESYS supplement for licences on iMX8.</li>
</ul>
<h2>[1.3.0.9] - 2023-10-24</h2>
<h3>Added</h3>
<ul>
<li>Added iE BSP component.</li>
<li>Updated TIM61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated AIO61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated DIM61 devdesc to v1.0.0.0, revision 2.</li>
<li>Updated DOM61 devdesc to v1.0.0.0, revision 3.</li>
<li>Updated DIO61 devdesc to v1.0.1.0, revision 2.</li>
<li>Updated DIO62 devdesc to v1.0.0.0, revision 2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AGI 400M Chromium &#x2013; v112-0.7</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/agi-400m-chromium/112-0-7/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6ce5129a-90b0-4b52-841e-45d22fe6329e</guid>
        <pubDate>2025-01-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AGI 400M Chromium</category>
        <category domain="version">112-0.7</category>
          <category domain="release-status">current</category>
          <category domain="product">AGI 400</category>
        <content:encoded><![CDATA[
<p>First Chromium browser release for the AGI 400 M series.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">eb9647dd-eed6-42e6-80c5-8eed97470f01</guid>
        <pubDate>2025-01-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.6.0</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: Is is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40&nbsp;</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue causing Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.8.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-8-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fe42fde7-8707-4d1a-9228-05dfff41dde2</guid>
        <pubDate>2025-02-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.8.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue that sometimes prevents start-up of controller.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improved wire break detection handling.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0eae0770-b4a1-4012-afd5-2c1194d4e921</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be set up to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to use in the flexible Modbus.&nbsp;</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350.&nbsp;</li>
<li>Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350.</li>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control". &nbsp;</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.&nbsp;</li>
<li>Added write permission for "Priorities" when the controller is in emulation.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI were not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups could not be collapsed using touch.</li>
<li>Fixed issue where iE 250 failed to start up without MIO module.</li>
<li>Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.</li>
<li>Fixed issue where display user could not clear DM2 logs.</li>
<li>Fix issue where iE controller could not start without MIO module.&nbsp;</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where user could enter parameter values outside of valid range.</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Fixed issue where PIM2.1 DIO levels were inverted.</li>
<li>Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms. &nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS were hidden in the IO configuration.</li>
<li>Fixed issue where PWM was not working on MIO2.1.</li>
<li>Fixed issue where Genset was not deloading correctly when it was connected to mains.</li>
<li>Fixed issue where BUS TIE breaker could not deload and open a ring connected busbar.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ae836b70-ab9e-4da7-9c6d-14d72d245c5c</guid>
        <pubDate>2025-06-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>2.0.10.1 based on 2.0.9.0</h4>
<h3>New features</h3>
<ul>
<li>The user can now read the device serial number in CODESYS</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Opening I/Os in a backup or config file no longer results in an error popup</li>
<li>Fixed issue with fieldbus connection handling that prevented correct connections from being displayed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4b6889a0-73c5-4313-bb01-c94e760af33d</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
<li>Fixed an issue where external and redundant breaker feedback could result in an incorrect breaker position state.</li>
<li>Dynamic Section Status is now available again in CODESYS Development System.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">604b0be8-841c-4ba5-ba11-34ac522cc922</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where it was not possible to back up and restore user management.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5a9b4e29-e629-4e6f-9da8-4c492977245d</guid>
        <pubDate>2025-10-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added new average system frequency measurement.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>iE250: Fixed issue where a custom name for an I/O on the controller would also name an I/O on an IOM3.1 module.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Changed custom logic so the CB configuration failure alarm does not appear.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">198b025b-58bf-4259-9fdc-366d79d3737b</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.1 (based on version 2.0.15.0)</h4>
<h3>New feature</h3>
<ul>
<li>EtherCAT® performance improvements, enhancing communication between PCM2.1 and extension racks.</li>
</ul>
<h3>Correction</h3>
<ul>
<li>Fixed an issue where the selected display header did not remain active after a power cycle of the controller.</li>
<li>Fixed an issue which caused controller to restart if user did not take action</li>
</ul>
<h4><br>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4><br>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes</h3>
<ul>
<li>Architectural updates in preparation for new power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the bootloader was not updating correctly.</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 from operating, causing a System Not OK alarm.</li>
<li>Fixed an issue with GAM3.2 configuration when in stand-alone mode for analogue regulation.</li>
<li>Fixed an issue with synchronisation visualisation.</li>
<li>Fixed an issue where permissions were missing after a backup/restore cycle.</li>
<li>Fixed an issue affecting the performance of analogue regulation on the analogue bidirectional I/O terminals.</li>
<li>Fixed an issue with the logout message in WebConfig.</li>
<li>Fixed an issue with the new password error in User Management.</li>
<li>Fixed an issue where spurious information was occupying log entries, making it harder to see valid entries.</li>
<li>Fixed an issue where Chinese characters were not displayed correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.16.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-16-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">65b56731-b8ed-4d0b-bf78-631a1b3b177e</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.16.2</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed an issue with the preview feature “AUTO / MANUAL” where the cooldown timer was skipped if the mode was changed from MANUAL to AUTO during the cooldown sequence.</li>
<li>Fixed an issue where restoring an older backup on version 2.0.15.0 or newer prevented logging in to the controller from the CODESYS IDE.</li>
<li>Fixed an issue where it was not possible to select imperial units on the controller.</li>
<li>Fixed an issue that allowed the controller variant check to be overridden during backup restoration.</li>
<li>Fixed an issue where backups over 50 MB could not be restored to the controller.</li>
<li>Fixed an issue where it was not possible to log in to the controller after a factory reset.</li>
<li>EIC: Fixed missing SAE J1939 SPN texts for DM1 and DM2 alarms.</li>
<li>EIC: Fixed missing measurement for engine oil-filter differential pressure.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 250 Application SW (Flexible application) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-flex/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1389bc0e-68db-4536-a677-affa05b01db7</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 250 Application SW (Flexible application)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present after a factory reset.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Expanded diagnostic message support with all valid SAE J1939 SPN texts for DM1 and DM2 alarm descriptions.</li>
<li>Added RSTP support, enabling switching between RSTP switches in a running system.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated the I/O configuration experience for iE 250 controller AIOs.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user was not present after a factory reset.</li>
<li>Resolved an issue that prevented the emulation engine from starting after a previously configured start failure.</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Fixed an issue that prevented breaker closure onto a black busbar after a start engine and close breaker command followed by a start failure.</li>
<li>Fixed a defect in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
<li>Corrected incorrect source addressing for TSC1 and CM1 for FPT / Iveco Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4a92624e-caf4-4699-b77e-70df8e22ad4a</guid>
        <pubDate>2025-01-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<p>2.0.8.0 based on 2.0.6.0</p>
<h3>New features</h3>
<ul>
<li>Web Config Tool: Added a Version page with version information of the different software components.</li>
<li>Web Config Tool: Added support for PTP time synchronisation.</li>
<li>It is now possible to manually disable/enable the USB port &nbsp;when not in use. (cyber security).</li>
<li>EIC: Added Cummins Industrial protocol.</li>
<li>EIC: Added Baudouin 6M33 protocol.</li>
<li>Added support for DIO2.1 and AIO2.1 plug-in modules.</li>
<li>Added device descriptions for 600-series hardware modules for use in CODESYS.</li>
<li>Added alarm to indicate unknown traffic on the DEIF network (cyber security).</li>
<li>Network port configuration: &nbsp;New "Standalone" mode to allow CODESYS to be used on Port 0.</li>
<li>Added CustomLogic signals to display designer for extra monitoring capabilities.</li>
<li>Added iE 7 Display support via Display Port for the iE 250 Base-mounted variant and the iE 350.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Improvements to the IP address settings.</li>
<li>Logs: Is is now possible to press Info when the search filter is highlighted.</li>
<li>Introduced an alarm to inform users about malfunctioning hardware modules.</li>
<li>Introduced an alarm to inform users about configuration issues on hardware modules.</li>
<li>Added fuel level as an engine measurement.</li>
<li>Increased the persistent storage to 128KB.</li>
<li>Upgraded CODESYS runtime version to v3.5.20.40.&nbsp;</li>
<li>J1939: Added 40 measurements to analogue output functions.</li>
<li>Under frequency detection for NEL can now be specified to a tenth of a percentage point.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue causing DM2 logs to be empty.</li>
<li>Fixed an issue causing display texts not to be translated.</li>
<li>Fixed an issue that allowed users to change parameters without logging in.</li>
<li>Fixed an issue where custom I/O tests were not shown.</li>
<li>Fixed an issue where the DEF level gauge was shown on the dashboard for a Yanmar Stage V engine.</li>
<li>Web Config Tool: Fixed an issue causing the user management to stay in edit mode.</li>
<li>Web Config Tool: Fixed an issue preventing to write the time settings from the web interface.</li>
<li>Fixed issues in user management preventing users from being deleted or having reassigned roles.</li>
<li>Fixed an issue causing the status LED to go out of sync.</li>
<li>Fixed MIO2.1 device description.</li>
<li>Fixed issues with voltage measurement when emulating a split-phase system.</li>
<li>Fixed an issue where "System no OK" alarm could occur after changing the time on the controller.</li>
<li>Fixed an issue with phase-neutral voltage protections for split- and single-phase AC setups.</li>
<li>Fixed an issue in DVC voltage parameters for split-phase.</li>
<li>EIC: Fixed an issue causing Stage V lamps for Scania S8 (DEF warning lamp) and Isuzu (Regen warning lamp) not to work.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cc3e5810-4008-477f-8cc0-0a8e2399cabe</guid>
        <pubDate>2025-05-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>2.0.9.0 based on 2.0.8.1</h4>
<h3>New features</h3>
<ul>
<li>Three pump logic routines can now be set up to control the pumping of a substance.</li>
<li>Implement ECU diagnostic to enable run coil and ECU power while the engine is stopped.</li>
<li>All configuration dependent values are now possible to use in the flexible Modbus. &nbsp;<br>e.g. power supply measurements (dependent on hardware and number of extension racks) can now be mapped to Modbus.</li>
<li>Up to 10 ACM3.1 cards allowed in one controller to be used for measurement (preview feature).</li>
</ul>
<h3>Changes</h3>
<ul>
<li>EIC: Volvo Penta EMS2.4: "Engine Override Control Mode" changed to "Speed control". &nbsp;</li>
<li>EIC: Volvo Penta EMS2.4: TSC1 will not be transmitted if VP70 is used for regulation.&nbsp;</li>
<li>Modbus timeout increased from 10 sec to 100 sec on iE 250 and iE 350. &nbsp;</li>
<li>Number of possible Modbus connections changed from 20 to 100 on iE 250 and iE 350</li>
<li>Added write permission for "Priorities" when controller is in emulation.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue where changes made in the UI were not registered.</li>
<li>Fixed issue where the "IO configuration" menu would show empty slots.</li>
<li>Fixed issue where tree-structure menu groups could not be collapsed using touch.</li>
<li>Fixed issue where configuring a Modbus value to "true" made the value "255" instead of "1".</li>
<li>Fixed issue where measurements from multiple ECUs were not shown in UI for e.g. configuring alarms.</li>
<li>Fixed issue where display user could not clear DM2 logs.</li>
<li>Fixed issue where iE controller could not start without MIO module.&nbsp;</li>
<li>Fixed issue with missing alarm icons.</li>
<li>Fixed issue where user could enter parameter values outside of valid range. &nbsp;</li>
<li>Fixed checksum and counter for VP70.</li>
<li>Fixed issue where removing network cable would activate system NOK, IO service error and "temperature too high" alarms.&nbsp;</li>
<li>Fixed issue where CODESYS user management files were not included in the backup/restore.</li>
<li>Fixed issue where linked outputs in CODESYS was hidden in IO configuration.</li>
<li>Fixed issue where the Genset was not de-loading correctly when it was connected to the Mains.</li>
<li>Fixed issue where BUS TIE breaker could not de-load and open a ring connected busbar.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.9.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-9-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2d4f7a7a-6fd8-4153-a0a1-ee6f60d63a47</guid>
        <pubDate>2025-06-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.9.1</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>2.0.9.1 based on 2.0.9.0</h4>
<h3>Corrections:</h3>
<ul>
<li>Fixed issue where external and redundant breaker feedback could result in an incorrect breaker position state</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.10.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-10-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">84feb4b5-90ee-4fa3-96a4-7d8286496def</guid>
        <pubDate>2025-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.10.1</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>2.0.10.1 based on 2.0.9.1</h4>
<h3>New features:</h3>
<ul>
<li>Users can now read the device serial number in CODESYS</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>Opening I/Os in a backup or config file no longer results in an error pop-up</li>
<li>Resolved an issue with fieldbus connection handling that previously prevented correct connections from being displayed</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cd107e22-261a-4514-9409-77cf1e90061d</guid>
        <pubDate>2025-07-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Increased maximum delay time on all single-measurement alarms such as frequency, voltage, power, current, over and under alarms.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where entries on DM2Logs were missing text.</li>
<li>IOM3.2: Fixed an issue where PWM output was not usable. It can now be enabled with a fixed frequency and voltage on AO1 and AO2.</li>
<li>Fixed an issue where the display command drop-down list contained duplicate entries.</li>
<li>iE 250: Fixed an issue where the connection to the extension rack was lost when both the plug-in module and the extension rack were connected.</li>
<li>Fixed an issue where the Eventlog had missing text and missing attributes.</li>
<li>iE 250: Fixed an issue where the "Fieldbus connection missing" alarm was triggered even when the connections were OK.</li>
<li>Fixed an issue where it was not possible to set Port mode to RSTP External.</li>
<li>Dynamic Section Status is now available again in CODESYS Development System.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.11.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-11-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1c6e322d-a54a-4f91-b57d-b7aad058bf86</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.11.2</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>Corrections</h3>
<ul>
<li>Fixed issue where it was not possible to back up and restore user management</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6e6245a8-1f11-49df-94e8-0e04ebbd3dd6</guid>
        <pubDate>2025-10-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Added new average system frequency measurement.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added event log entry when time settings are changed.</li>
<li>Alarm timestamps are now only updated when being acknowledged.</li>
<li>Alarms are no longer sorted by last interaction.</li>
<li>iE250: Fixed issue where a custom name for an I/O on the controller would also name an I/O on an IOM3.1 module.</li>
<li>Fixed issue where the CustomTexts JSON endpoint returned inaccurate responses and corrected data format for POST.</li>
<li>Changed custom logic so the CB configuration failure alarm does not appear.</li>
<li>Fixed issue where Directional Overcurrent 1 and 2 were not enabled after power cycle if set point values were negative.</li>
<li>It is now possible to map both digital and analogue inputs/outputs to Modbus addresses, across all ranges of iEx50.</li>
<li>Corrected timing for transmission of CAN telegrams.</li>
<li>Fixed an issue where the 'Module update required' pop-up was not triggered as expected.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.16.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-16-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">90f04fe3-3833-42f1-ada8-731852e2efd1</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.16.1</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>Version 2.0.16.1 (based on version 2.0.15.0)</h4>
<h3>New feature</h3>
<ul>
<li>EtherCAT® performance improvements, enhancing communication between PCM2.1 and extension racks.</li>
</ul>
<h3>Correction</h3>
<ul>
<li>Fixed an issue where the selected display header did not remain active after a power cycle of the controller.</li>
<li>Fixed an issue which caused controller to restart if user did not take action</li>
</ul>
<h4>Version 2.0.15.0 (based on version 2.0.14.1)</h4>
<h3>New features</h3>
<ul>
<li>EIC: Added John Deere Stage V protocol.</li>
<li>Added Engine heater logic.</li>
<li>Added 16 analogue ICC values. These values are global, meaning all controllers can read and write to each of the 16 values.</li>
<li>Added the possibility to restore a different variant when the controller is not part of a plant.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Resolved an issue where the NTP server connection status intermittently failed to update, resulting in false alarms indicating no NTP servers were connected even when servers were actively synchronised. The system now correctly detects and reports NTP server status, including proper handling of transient connection states during normal NTP operation.</li>
<li>Added proprietary DEF level reading for Scania EMS2 S8 and Isuzu protocols.</li>
<li>Added missing alarm output from PMS network monitoring.</li>
<li>Resolved an issue where NTP could not be configured in PICUS.</li>
<li>Fixed the possibility to change brightness level.</li>
<li>Fixed an issue with backup to PICUS where the controller displayed an error.</li>
</ul>
<h4>Version 2.0.14.1 (based on version 2.0.14.0)</h4>
<h3>Corrections</h3>
<ul>
<li>Fixed authentication issue.</li>
</ul>
<h4>Version 2.0.14.0 (based on version 2.0.13.0)</h4>
<h3>Changes</h3>
<ul>
<li>Architectural updates in preparation for new power management.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where the bootloader was not updating correctly.</li>
<li>Fixed an issue that prevented IOM3.2 or IOM3.3 from operating, causing a System Not OK alarm.</li>
<li>Fixed an issue with GAM3.2 configuration when in stand-alone mode for analogue regulation.</li>
<li>Fixed an issue with synchronisation visualisation.</li>
<li>Fixed an issue where permissions were missing after a backup/restore cycle.</li>
<li>Fixed an issue affecting the performance of analogue regulation on the analogue bidirectional I/O terminals.</li>
<li>Fixed an issue with the logout message in WebConfig.</li>
<li>Fixed an issue with the new password error in User Management.</li>
<li>Fixed an issue where spurious information was occupying log entries, making it harder to see valid entries.</li>
<li>Fixed an issue where Chinese characters were not displayed correctly..</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE 350 Application SW (Flexible application) &#x2013; v2.0.17.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-flex/2-0-17-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4701ecd6-d884-42e6-b415-e0bcd7676371</guid>
        <pubDate>2026-04-17T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE 350 Application SW (Flexible application)</category>
        <category domain="version">2.0.17.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Improved system robustness with a workaround that prevents unexpected stoppage of the CODESYS OPC UA server channels.</li>
<li>Added support for reading the number of alarms in each alarm state.</li>
<li>Enhanced factory reset handling by ensuring that a valid default admin user is always present.</li>
<li>Improved traceability through additional log entries for function controls.</li>
<li>Introduced a preview function for rescaling CAN analogue input values.</li>
<li>Expanded diagnostic message support with all valid SAE J1939 SPN texts for DM1 and DM2 alarm descriptions.</li>
<li>Added RSTP support, enabling seamless switching between RSTP switches in a running system.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed a defect where the admin user could be missing after a factory reset.</li>
<li>Resolved an issue that prevented the emulation engine from starting after a previously configured start failure.</li>
<li>Fixed a defect where restoring older backups could block login to the controller from the CODESYS Development System (IDE).</li>
<li>Corrected incorrect Cummins gain scaling.</li>
<li>Fixed backup restore failures for backups larger than 50 MB.</li>
<li>Resolved a defect where the cooldown timer could be skipped when switching from MANUAL to AUTO mode while the AUTO / MANUAL preview function was active.</li>
<li>Fixed a defect that could cause the GAM3.2 AVR output to unexpectedly go to 100 % when disconnecting an extension rack or removing power from the main controller.</li>
<li>Corrected an issue that prevented breaker closure onto a black busbar after a start failure.</li>
<li>Fixed defects in EtherCAT configuration handling that could cause unexpected relay activation in an extension rack.</li>
<li>Corrected incorrect source addressing for TSC1 and CM1 for FPT / Iveco Stage V engines.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 CODESYS TSP (SP20) &#x2013; v1.3.2.0 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-codesys-tsp-sp20/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">804119db-9257-47da-b369-ec5eb1eca61f</guid>
        <pubDate>2025-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 CODESYS TSP (SP20)</category>
        <category domain="version">1.3.2.0 (SP20)</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 CODESYS TSP (SP20) &#x2013; v1.3.2.2 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-codesys-tsp-sp20/1-3-2-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c7e39eb6-ef12-4389-a285-0372d91f6653</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 CODESYS TSP (SP20)</category>
        <category domain="version">1.3.2.2 (SP20)</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<h2>[1.3.2.2] - 2025-01-21</h2>
<h3>Changes</h3>
<ul>
<li>Reversed the boolean level for negative input on iE 250 Local Digital IO.</li>
<li>In TSP, &nbsp;the names Input Positive and Input Negative are used on iE 250 local Digital IO.</li>
</ul>
<h2><br>[1.3.2.1] - 2025-01-15 Not Released</h2>
<h3>New features</h3>
<ul>
<li>Added recipe folder under PLCLogic.</li>
</ul>
<h3>Changes&nbsp;</h3>
<ul>
<li>Changed FilePath to PLCLogic for PCM21, PCM33 and PCM62.</li>
<li>Made codesys-services wanted by custom-$variant.service.</li>
</ul>
<h2>[1.3.2.0] - 2025-01-08&nbsp;</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE350 CODESYS TSP (SP20) &#x2013; v1.3.0.16 (SP18)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie350-codesys-tsp-sp20/13016/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ab7ef171-efa7-47cd-81c4-469218101004</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE350 CODESYS TSP (SP20)</category>
        <category domain="version">1.3.0.16 (SP18)</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p>&nbsp;</p>
<h3>Feature</h3>
<ul>
<li>Initial release of iE 350 CODESYS SP18 Target Support Package.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE250 CODESYS TSP  &#x2013; v1.3.2.0 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-codesys-tsp-sp20/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0bb1f8d9-85a4-46f0-9a54-a09fd20d714b</guid>
        <pubDate>2025-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE250 CODESYS TSP </category>
        <category domain="version">1.3.2.0 (SP20)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE250 CODESYS TSP  &#x2013; v1.3.2.2 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-codesys-tsp-sp20/1-3-2-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">df9b4115-b6cf-4f80-a28a-55342eec81d5</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE250 CODESYS TSP </category>
        <category domain="version">1.3.2.2 (SP20)</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<h2>[1.3.2.2] - 2025-01-21</h2>
<h3>Changes</h3>
<ul>
<li>Reversed the boolean level for negative input on iE 250 Local Digital IO.</li>
<li>In TSP, &nbsp;the names Input Positive and Input Negative are used on iE 250 local Digital IO.</li>
</ul>
<h2><br>[1.3.2.1] - 2025-01-15 Not Released</h2>
<h3>New features</h3>
<ul>
<li>Added recipe folder under PLCLogic.</li>
</ul>
<h3>Changes&nbsp;</h3>
<ul>
<li>Changed FilePath to PLCLogic for PCM21, PCM33 and PCM62.</li>
<li>Made codesys-services wanted by custom-$variant.service.</li>
</ul>
<h2>[1.3.2.0] - 2025-01-08&nbsp;</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE250 CODESYS TSP  &#x2013; v1.3.0.16 (SP18)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie250-codesys-tsp-sp20/1-3-0-16/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">44b1435b-4feb-4fee-9e59-ddc32edcc1d9</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE250 CODESYS TSP </category>
        <category domain="version">1.3.0.16 (SP18)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 PLC</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p>&nbsp;</p>
<h3>Feature</h3>
<ul>
<li>Initial release of iE 250 CODESYS SP18 Target Support Package.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 CODESYS TSP (SP20) &#x2013; v1.3.2.0 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-codesys-tsp-sp20/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3dc75766-be4e-4673-901f-0ef8041ba9b9</guid>
        <pubDate>2025-01-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 CODESYS TSP (SP20)</category>
        <category domain="version">1.3.2.0 (SP20)</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 CODESYS TSP (SP20) &#x2013; v1.3.2.2 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-codesys-tsp-sp20/1-3-2-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fb35ba6b-9f16-4c2f-9974-c8be82cf2d7e</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 CODESYS TSP (SP20)</category>
        <category domain="version">1.3.2.2 (SP20)</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h2>[1.3.2.2] - 2025-01-21</h2>
<h3>Changes</h3>
<ul>
<li>Reversed the boolean level for negative input on iE 250 Local Digital IO.</li>
<li>In TSP, &nbsp;the names Input Positive and Input Negative are used on iE 250 local Digital IO.</li>
</ul>
<h2><br>[1.3.2.1] - 2025-01-15 Not Released</h2>
<h3>New features</h3>
<ul>
<li>Added recipe folder under PLCLogic.</li>
</ul>
<h3>Changes&nbsp;</h3>
<ul>
<li>Changed FilePath to PLCLogic for PCM21, PCM33 and PCM62.</li>
<li>Made codesys-services wanted by custom-$variant.service.</li>
</ul>
<h2>[1.3.2.0] - 2025-01-08&nbsp;</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE650 CODESYS TSP (SP20) &#x2013; v1.3.0.16 (SP18)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie650-codesys-tsp-sp20/1-3-0-16/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">278b3cef-0442-4029-af63-7e17cc691289</guid>
        <pubDate>2024-06-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE650 CODESYS TSP (SP20)</category>
        <category domain="version">1.3.0.16 (SP18)</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p>Target Support Package for installation in CODESYS.</p>
<p>This version relates specific to CODESYS ver. 3.5.18.40</p>
<p>&nbsp;</p>
<h3>Feature</h3>
<ul>
<li>Initial release of iE 650 CODESYS SP18 Target Support Package.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 Mk II Lite firmware &#x2013; vR16.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mk-ii-lite-firmware/r16-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">533b1204-c0b7-4a02-81fa-a0ccdd7774ec</guid>
        <pubDate>2025-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 Mk II Lite firmware</category>
        <category domain="version">R16.00</category>
          <category domain="product">SGC 120 Mk II Lite</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Initial version, includes functions and features from SGC 120 Mk ll R16.00 except CAN and Modbus related functions.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 120 Mk II Lite firmware &#x2013; vR17.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-120-mk-ii-lite-firmware/r17-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">6c195fec-a089-401a-af3a-65794b65d4f4</guid>
        <pubDate>2025-04-08T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 120 Mk II Lite firmware</category>
        <category domain="version">R17.00</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 120 Mk II Lite</category>
        <content:encoded><![CDATA[
<h4>SGC120 R17.00 Lite</h4>
<h3>New features&nbsp;</h3>
<ul>
<li>Added ability to display customer details on the bootup screen through the display language tool.</li>
<li>Added live button implementation.</li>
<li>Added LTO, remote acknowledgement, auto mode, manual mode, digital inputs, and M-Logic events.</li>
<li>Added digital output for Louvre control command and pre-lube pump M-Logic command.</li>
<li>Added common screen for genset data.</li>
<li>Added analogue sensor value in live data.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Phase reversal handling updated during the stop sequence.</li>
<li>Overload protection time has been increased from 600 to 3600 seconds.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 Mk II Lite Firmware &#x2013; vR17.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mk-ii-lite-firmware/r17-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f6dce315-e497-4a6e-94f4-fd301a295060</guid>
        <pubDate>2025-02-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 Mk II Lite Firmware</category>
        <category domain="version">R17.00</category>
          <category domain="product">SGC 420 Mk II Lite</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Initial version, includes functions and features from SGC 420 Mk ll R17.00 except CAN and Modbus related functions.&nbsp;</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC 420 Mk II Lite Firmware &#x2013; vR18.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-420-mk-ii-lite-firmware/r18-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3bfe3f96-3c73-43e3-9bbf-79cb9823f540</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC 420 Mk II Lite Firmware</category>
        <category domain="version">R18.00</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 420 Mk II Lite</category>
        <content:encoded><![CDATA[
<h4>R18.00 based on R17.00</h4>
<h3>New Features</h3>
<div>
<ul>
<li><span>Common/Genset Data screen</span></li>
</ul>
</div>
<h3>Changes</h3>
<ul>
<li><span>Increase Overload Delay range (from 600 to 3600 seconds)</span></li>
<li><span>Change minimum Fuel Level Range (from 2L to 0L)&nbsp;</span></li>
<li><span>Modification of logic to display Fuel in litres on screen,</span>&nbsp;based on Fuel Level Value</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP20 Patch 40) &#x2013; v1.3.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp20-patch-40/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">57f20aa6-b57d-4765-8fe1-3116457351f2</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP20 Patch 40)</category>
        <category domain="version">1.3.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h2>[1.3.2.0] - 2025-01-08&nbsp;</h2>
<h3>New features</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
<p>&nbsp;</p>
<h2>[1.3.0.18] - 2024-06-10</h2>
<h3>Added</h3>
<ul>
<li>Updated CmpXml2 to v3.5.15.1.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue using CmpXml2 component on PCM6.2.</li>
<li>Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</li>
</ul>
<h2>[1.3.0.17] - 2024-05-15</h2>
<h3>Added</h3>
<ul>
<li>Added buildinfo manual step.</li>
</ul>
<h2>[1.3.0.16] - 2024-05-08</h2>
<h3>Added</h3>
<ul>
<li>Enforce HTTPS on webvisu.</li>
<li>Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.</li>
<li>Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.</li>
<li>Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</li>
</ul>
<h2>[1.3.0.15] - 2024-04-22</h2>
<h3>Added</h3>
<ul>
<li>Enable enforce user management on all targets.</li>
<li>Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
<li>Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</li>
</ul>
<h2>[1.3.0.14] - 2024-02-29</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime 3.5.19.60.</li>
</ul>
<h2>[1.3.0.13] - 2024-01-31</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
<li>Off by one.</li>
</ul>
<h2>[1.3.0.12] - 2024-01-35</h2>
<ul>
<li>HF release from branch.</li>
</ul>
<h2>[1.3.0.11] - 2024-01-25</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
</ul>
<h2>[1.3.0.10] - 2024-01-04</h2>
<h3>Added</h3>
<ul>
<li>Updated ACM31 devdesc to v5.1.0.0.</li>
<li>Updated IOM32 devdesc to v1.0.0.4.</li>
<li>Added LibModbus version 1.1.0.6. Fix connection return value truncated to 0.</li>
<li>Added CODESYS supplement for licences on iMX8.</li>
</ul>
<h2>[1.3.0.9] - 2023-10-24</h2>
<h3>Added</h3>
<ul>
<li>Added iE BSP component.</li>
<li>Updated TIM61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated AIO61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated DIM61 devdesc to v1.0.0.0, revision 2.</li>
<li>Updated DOM61 devdesc to v1.0.0.0, revision 3.</li>
<li>Updated DIO61 devdesc to v1.0.1.0, revision 2.</li>
<li>Updated DIO62 devdesc to v1.0.0.0, revision 2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP20 Patch 40) &#x2013; v1.3.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp20-patch-40/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">22ecadf5-060d-4661-8a25-2fe403c2ab9e</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP20 Patch 40)</category>
        <category domain="version">1.3.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h2>&nbsp;[1.3.2.0] - 2025-01-08</h2>
<h3>New features&nbsp;</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.&nbsp;</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
<h2>[1.3.0.18] - 2024-06-10</h2>
<h3>Added</h3>
<ul>
<li>Updated CmpXml2 to v3.5.15.1.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed issue using CmpXml2 component on PCM6.2.</li>
<li>Support for CODESYS runtimes older than v3.5.19.60 has been removed on pcm31bsp4, pcm52, pcm61, and pcm62bsp3.</li>
</ul>
<h2>[1.3.0.17] - 2024-05-15</h2>
<h3>Added</h3>
<ul>
<li>Added buildinfo manual step.</li>
</ul>
<h2>[1.3.0.16] - 2024-05-08</h2>
<h3>Added</h3>
<ul>
<li>Enforce HTTPS on webvisu.</li>
<li>Added IOM32 devdesc 1.0.0.2, Revision=16#01000003.</li>
<li>Added PCM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added PCM62 devdesc 1.0.1.0, Revision=16#00000001.</li>
<li>Added PCM62-bsp3 devdesc 1.0.1.0, Revision=16#00000002.</li>
</ul>
<h2>[1.3.0.15] - 2024-04-22</h2>
<h3>Added</h3>
<ul>
<li>Enable enforce user management on all targets.</li>
<li>Added MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
<li>Added MIO21 devdesc 1.0.0.0, Revision=16#00010000.</li>
</ul>
<h2>[1.3.0.14] - 2024-02-29</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime 3.5.19.60.</li>
</ul>
<h2>[1.3.0.13] - 2024-01-31</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
<li>Off by one.</li>
</ul>
<h2>[1.3.0.12] - 2024-01-35</h2>
<ul>
<li>HF release from branch.</li>
</ul>
<h2>[1.3.0.11] - 2024-01-25</h2>
<ul>
<li>Do not start CODESYS if licence is missing.</li>
</ul>
<h2>[1.3.0.10] - 2024-01-04</h2>
<h3>Added</h3>
<ul>
<li>Updated ACM31 devdesc to v5.1.0.0.</li>
<li>Updated IOM32 devdesc to v1.0.0.4.</li>
<li>Added LibModbus version 1.1.0.6. Fix connection return value truncated to 0.</li>
<li>Added CODESYS supplement for licences on iMX8.</li>
</ul>
<h2>[1.3.0.9] - 2023-10-24</h2>
<h3>Added</h3>
<ul>
<li>Added iE BSP component.</li>
<li>Updated TIM61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated AIO61 devdesc to v1.0.1.1, revision 4.</li>
<li>Updated DIM61 devdesc to v1.0.0.0, revision 2.</li>
<li>Updated DOM61 devdesc to v1.0.0.0, revision 3.</li>
<li>Updated DIO61 devdesc to v1.0.1.0, revision 2.</li>
<li>Updated DIO62 devdesc to v1.0.0.0, revision 2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 PLC CODESYS libraries &#x2013; v2.0.8.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-plc-codesys-libraries/2-0-8-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f25b081-be60-4c6e-91d7-af38c1d093d0</guid>
        <pubDate>2025-02-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 PLC CODESYS libraries</category>
        <category domain="version">2.0.8.0</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>[2.0.8.0] - 2025-01-21</h3>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Interface Libraries for iE 250/350/650.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 PLC CODESYS libraries &#x2013; v2.0.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-plc-codesys-libraries/2-0-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">d0392b9b-aad7-4b2b-9e08-4cd9e26c82a2</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 PLC CODESYS libraries</category>
        <category domain="version">2.0.10.0</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.0] - 2025-06-11</h4>
<h3>New feature</h3>
<ul>
<li>Enabled deprecated code in libraries</li>
</ul>
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.10.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 PLC CODESYS libraries &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-plc-codesys-libraries/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f385f116-e9cc-4c67-8785-965159244c27</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 PLC CODESYS libraries</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.11.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 PLC CODESYS libraries &#x2013; v2.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-plc-codesys-libraries/2-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">affc1aa8-4c6b-47af-a7d0-2d77b30e3098</guid>
        <pubDate>2025-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 PLC CODESYS libraries</category>
        <category domain="version">2.0.14.0</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>## [2.0.14.0] - 2025-10-30</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.14.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 PLC CODESYS libraries &#x2013; v2.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-plc-codesys-libraries/2-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">139917cd-78fd-4062-a2be-5f445c7a4df2</guid>
        <pubDate>2025-12-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 PLC CODESYS libraries</category>
        <category domain="version">2.0.15.0</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>## [2.0.15.0] - 2025-12-17</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.15.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 PLC CODESYS libraries &#x2013; v2.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-plc-codesys-libraries/2-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e950fc35-b2b7-4537-97de-1ca4c6356215</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 PLC CODESYS libraries</category>
        <category domain="version">2.0.16.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Databases changed to version 2.0.16.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.30.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-30-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5aa0caef-ee55-461d-b231-f6c415311df8</guid>
        <pubDate>2025-02-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.30.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.61.0</li>
<li>TDU version required: 1.4.3.1</li>
</ul>
<p>PM compatibility: 1.40.0</p>
<h3>New features</h3>
<ul>
<li>Marine GENSET: Able to synchronise and able to be a part of a marine power management system.</li>
<li>Marine SHORE: New product variant for marine power management system.</li>
<li>Marine BTB: New product variant for marine power management system.</li>
<li>Marine STORAGE: New product variant for marine power management system.</li>
<li>Marine SOLAR: New product variant for marine power management system.</li>
<li>STORAGE: Added new PCS protocol for YUNT PCS</li>
<li>EIC: Added support of Yanmar gas 4G.</li>
<li>EIC: Added support of TSC1 destination address and CVT.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>SEMI renamed to MANUAL.</li>
<li>MANUAL renamed to NO REGULATION.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed unintended relay hazard causing certain functions not to be configured.</li>
<li>STORAGE: Fixed issues where ASC 150 Storage could not change the ESS TCP port number.</li>
<li>STORAGE: Fixed issues where the SOC counters on the ASC 150 showed incorrect values both in read and write in specific cases.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.31.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-31-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">97b2f23c-3156-44a9-b8ad-32cf7cf73ad9</guid>
        <pubDate>2025-05-05T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.31.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.0</li>
<li>TDU version required: 1.4.3.1</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>New features</h3>
<ul>
<li>STORAGE: Added possibility of remote start over Modbus for DSE 8xxx, 7xxx, 6xxx, 4xxx power meter protocol.</li>
<li>STORAGE: Added global/local start of external genset(s) in open PMS.</li>
<li>STORAGE: Added possibility of remote start over Modbus for DEIF Genset control power meter protocol.</li>
<li>STORAGE: Added Lanli Tech BMS protocol.</li>
<li>STORAGE: Added Sicon VSG ESS protocol.</li>
<li>EIC: Added many new SPN texts for DM1 log.</li>
<li>STORAGE: Added Sungrow LC300 protocol support.</li>
<li>EIC: Added support for Scania S6 Industrial.</li>
<li>STORAGE: Added SYL Golden Shield Liquid-cooled (SYL G. S. Liq) BMS protocol.</li>
<li>STORAGE: Added new parameter 8043 "PMS Isochr. Q ctrl" which enables off-grid reactive power regulation in a PMS Isochronous master setup.</li>
<li>STORAGE: Added two new M-Logic outputs for skipping P ramp up and another for P ramp down.</li>
<li>STORAGE: Added three new parameters for following or skipping ramps.
<ul>
<li>Isochronous load share parameter: When the controller is isomaster and another storage controller is on the busbar it will no longer skip ramp if iso load share parameter is enabled.</li>
<li>Over-frequency and under-frequency ramp limit parameters: If measured frequency is above or below these limits the system will skip the ramp.</li>
</ul>
</li>
<li>STORAGE: Added new M-Logic events for when any other battery is charging and any other battery is not "Energy functionality OK" in power management.</li>
<li>STORAGE: Added ABB PCS100 ESS protocol.</li>
<li>STORAGE: ESS and BB nominal voltages are now selectable as set point to general purpose PID.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE: Renamed Ningbo BMS to SYL G. S. Air as it relates to the new protocol.</li>
<li>STORAGE MARINE/SOLAR MARINE: The auto start/stop signal as digital input or M-Logic is no longer needed for allowing hybrid marine variants to auto start.</li>
<li>GENSET: The M-Logic functionality for manual GOV/AVR pulse increase/decrease are now available in the shortcut menu under "Regulation shortcuts" but only works in NoReg mode.</li>
<li>GENSET MARINE: The M-Logic functionality for manual GOV/AVR pulse increase/decrease are now available in the shortcut menu under "Regulation shortcuts" for genset marine in PMS but only works in SWBD control.</li>
<li>M-Logic: 'Virtual toggle' renamed to 'Virtual event' and 'Virtual switch' renamed to 'Virtual toggle'.
<ul>
<li>Virtual events now works the same on Modbus and in M-Logic. The output of the virtual event will follow the input of the virtual event.</li>
<li>Virtual toggles work the same on Modbus and in M-Logic. If the input of the virtual toggle goes high, the output changes state once.</li>
</ul>
</li>
<li>STORAGE/SOLAR/DGHYBRID: Updated internal power ramps to be more precise and allow adjustment of internal delay between ramp updates in parameters 2681 and 2682.</li>
<li>Added parameter 7075, "Mains Fail Assumption", which enables the Mains controller to assume that the mains have just recovered at start-up, allowing it to run the OK timers.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>GENSET LAND &amp; MARINE: If idle run was active, RMI oil pressure alarms would be active before it was detected that the engine was running. This has been changed so that the engine must be running before the alarms can be active.</li>
<li>STORAGE: Fixed issue where the voltage set point does not take voltage transformer into account. Ratio between ESS Nom U (Ch 6004) and BB Nom U (Ch 6053) is now multiplied to take voltage transformer into account when calculating voltage set point to PCS.</li>
<li>STORAGE: Oztek OZpcs-rs40 protocol correction: P and Q set points are now sent in both on-grid and off-grid instead of only on-grid.</li>
<li>Gen stop and GB Off M-Logic command can now stop the genset during the start sequence.</li>
<li>Digital input texts are shown correctly in display menu.</li>
<li>GENSET: M-Logic output to change PMS priority selection (#8031) to fuel optimisation was missing.</li>
<li>Remote display: Supervision view should now work with a continuous display on the remote unit.</li>
<li>ATS: Fixed controller displaying engine symbols at start-up on supervision view page.</li>
<li>HYBRID: Empty parameters in display with parameter list setup is no longer shown.</li>
<li>EIC: Custom DM1 alarms was not triggered. This has been fixed.</li>
<li>Fixed an issue where unsupported application alarm values were incorrect for unsupported Open PMS applications.</li>
<li>GENSET MARINE: ISLAND setup with two gensets now automatically starts second genset based on LD start.</li>
<li>GENSET MARINE and SHORE: TEST function removed. Still available for EDG.</li>
<li>STORAGE: Fixed issue for ESS protocol Sungrow LC200 DPS where charge and discharge capacity scaling was incorrect.</li>
<li>STORAGE/STORAGE MARINE: Fixed an issue where controller could continuously start and stop in AUTO mode.</li>
<li>GENSET MARINE: GB open without deload corrected.</li>
<li>GENSET MARINE: Removed PID1 from shortcut menu when Genset Marine is not a single controller/EDG application.</li>
<li>In the USW parameter list, Mains and BTB controllers would show that an inhibit was applied, even though it was not. This has been fixed.</li>
<li>STORAGE: Kubank LEMS BCU - Fixed issue where DC current could not be shown as a negative value. Added 3 new measurement values for phase voltages.</li>
<li>STORAGE: Updated Nomad BCU protocol - Droop and grid mode logic changed, reading faults and warnings updated to new Modbus addresses and more.</li>
<li>STORAGE/SOLAR: Corrected wrong Modbus addresses like Active power in address 40034 to address 33 and other registers for Cummins PC3 x PCC3300 powermeter protocol.</li>
<li>GENSET: The frequency/voltage regulation mode is no longer dependent on the frequency detection level when running with the GB closed.</li>
<li>GENSET: Show DEF level on all measurement views.</li>
<li>STORAGE: SinExcel PWS2 30K and SinExcel 30P ESS protocols have been adjusted to comply with SinExcel Modbus communication requirements.</li>
<li>M-Logic virtual toggles (previously named switches) can now be read over Modbus.</li>
<li>STORAGE/SOLAR: Fixed an issue where analogue output measurements was not working when measurement origin was set to ESS/PV communication.</li>
<li>SOLAR: Fixed an issue where parameter 7553 "RTU broadcast ID" was not accessible in PV communication menu.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.32.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-32-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">75d43765-b964-4f8a-9b28-7823e5ffd5e3</guid>
        <pubDate>2025-06-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.32.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.1</li>
<li>TDU version required: 1.4.5.0</li>
</ul>
<p>PM compatibility: 1.41.0</p>
<h3>New features</h3>
<ul>
<li>STORAGE: Added new protocol, Kehua Tech Local Controller (KC541A)</li>
<li>STORAGE: Added Faro BCU protocol.</li>
<li>STORAGE: Added new BMS protocol "CATL EnerOne Plus"; renamed "CATL liquid cooled" to "CATL EnerOne".</li>
<li>STORAGE: Added a new parameter 17056 "SOC resolution" to allow changing the default resolution for SOC of 1% to 0.1% or 0.01%.</li>
<li>STORAGE: Added CubEnergy BCU and Lithion GB protocol.</li>
<li>EIC: Added fuel rate alarm based on active power.</li>
<li>EIC: Added Guascor GCS-e ECU protocol.</li>
<li>EIC: Added aftertreatment icons for ISUZU.</li>
<li>EIC: Added Volvo Penta D12 protocol.</li>
<li>GENSET: Added counter for a number of successful generator starts.</li>
<li>GENSET: Add support of digital load sharing with SmartGen in SEMI mode.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE: Renamed ESS protocol for Yingbo PCS to InPower PCS.</li>
<li>EIC: Added TSC1 to YC-ECU-A.</li>
<li>EIC: Updated crankcase pressure (SPN 101) to kPa unit in delta alarms.</li>
<li>EIC: Updated Cummins PGI to version 4.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>STORAGE: Fixed an issue where single controller in AMF would charge from Mains when energy functionality was OK and "SOC + plant assist charging" was used as Mains charging mode.</li>
<li>STORAGE: Fixed an issue for Sungrow LC300 where heartbeat was not working.</li>
<li>STORAGE: Fixed several issues for WEG BIW610 PCS and WEG BMS:
<ul>
<li>WEG BIW610 PCS registers which were interpreted as big endian are now interpreted as little endian byteswap.</li>
<li>WEG BIW610 PCS sends nominal voltage/frequency on registers 500 and 508.</li>
<li>WEG BIW610 PCS will only send start signal when PCS is in the "Waiting" state.</li>
<li>WEG BMS sends a pulse every 90 s to register 95 for connecting BMS clusters.</li>
<li>WEG BMS will trigger BMS warning on every 'minor' alarm register with function code 0x02 and BMS shutdown on every 'moderate' alarm register with function code 0x02.</li>
</ul>
</li>
<li>STORAGE/SOLAR: Fixed inaccessible menus in tree and parameter views on display.</li>
<li>STORAGE/SOLAR/DGHYBRID: Corrected scaling of active power set point with non-default parameter 9030.</li>
<li>Configured Droop curve 2 with power factor output, now functions correctly.</li>
<li>STORAGE/SOLAR: Prevented mix-up of readings when using multiple powermeter types.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.32.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-32-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bc0153ce-8f56-4308-8d2b-ef346d9573fb</guid>
        <pubDate>2025-06-20T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.32.1</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<p>Requirements</p>
<ul>
<li>USW version: 3.62.1</li>
<li>TDU version: 1.4.5.0</li>
</ul>
<h3>Corrections:</h3>
<ul>
<li>EIC: Added SPN 5579 to delta alarms</li>
<li>Updated the Megarevo MPS ESS protocol</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.33.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-33-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">722f9246-4e79-41e6-b877-6172b318b316</guid>
        <pubDate>2025-07-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.33.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.62.1 PDB rev 11714</li>
<li>TDU version required: 1.4.5.0</li>
<li>PM compatibility: 1.41.0</li>
</ul>
<h3>New features</h3>
<ul>
<li>EIC: Added Mitsubishi protocol.</li>
<li>EIC: Added MTU ECU9 EMINOX protocol.</li>
<li>EIC: Added VECV E694 CPCB IV protocol.</li>
<li>STORAGE: Added new protocol - Qualtech BMS.</li>
<li>STORAGE: Added new ESS protocol - Sungiga SCU.</li>
<li>STORAGE: Added SinExcel PDS1-750K protocol.</li>
<li>STORAGE: Added Nari PCS 9567AN protocol.</li>
<li>SOLAR: Added new weather station protocol - Seven Sensor 3S-CWS.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>EIC: Updated Kubota Stage V to show alarms and texts for PCD/NCD and request PGN AT1S.</li>
<li>EIC: Added jump from alarm log to DM1 log.</li>
<li>GENSET: Added alarm to detect if primary starter has failed and the double starter is used instead (#6192).</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed an issue where Droop Curve 2 did not calculate cos phi droop correctly when leaving the deadband with a cos phi of less than 1.0.</li>
<li>Fixed an issue where the transfer of ground relay from deloaded genset to battery did not overlap.</li>
<li>Racked-out breaker can now be used when the controller is in BLOCK mode.</li>
<li>When DGs are forced to analogue load-share in a PMS setup, they can now back synchronise to the mains when directed to.</li>
<li>J1939-75 DM1 alarms now work again.</li>
<li>Fixed an issue where the scaling of values in the DG supervision view was incorrect.</li>
<li>STORAGE: Fixed an issue for FARO BCU where the active power set point would not be set. A new register, Enable active power set point, has been added to allow the active power set point to be set.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.34.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-34-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bf9a6309-0756-4953-ab12-3c6a44ef4cae</guid>
        <pubDate>2025-10-06T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.34.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.64.0 PDB rev. 11948</li>
<li>TDU version required: 1.4.5.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New features</h3>
<ul>
<li>GENSET: Added support for digital load sharing with ComAp in MAN mode.</li>
<li>EIC: Added protocol Wise18B.</li>
<li>EIC: Added protocol Kingbang.</li>
<li>EIC: Added protocol SDEC F31.</li>
<li>EIC: Added protocol SDEC F36.</li>
<li>EIC: Added protocol Yunnei.</li>
<li>EIC: Added protocol Yanmar X11.</li>
<li>EIC: Engine values now available in the shortcut menu.</li>
<li>STORAGE: Added new power management feature “SOC balancing”, which balances power between paralleling batteries.</li>
<li>STORAGE: Add two more PIDs to the system.</li>
<li>STORAGE: Added new BMS CAN protocol "Volvo Penta BE-C-03-GE".</li>
<li>STORAGE: Added new protocol Jinko JKP-1xxxHN-CA PCS.</li>
<li>STORAGE: Added Greatpower BMS protocol.</li>
<li>STORAGE: Added Jinko Utility BMS protocol.</li>
<li>STORAGE: Added Sungrow EMS300CP protocol.</li>
<li>STORAGE/SOLAR: Added new power meter protocol ComAp InteliGen 500 G2 for hybrid variants.</li>
<li>STORAGE: Added new protocol Delta PCS 1000.</li>
<li>STORAGE: Added new options in parameter 15016 “Opt. GEN load set” for dynamic start/stop of gensets.</li>
<li>In sync configurable relay output added, based on frequency (f), voltage (U), and phase angle (phi). Uses the same evaluation as the M-Logic flags.</li>
<li>PMS Lite: Added support for up to 254 controllers. Version increased to 5 and is not backwards compatible with earlier versions.</li>
<li>PMS Lite: Added support for BTB controllers in MANUAL mode.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE: ESS protocol “SinExcel PWS1” now uses protocol custom input to switch between new and old voltage offset regulation.</li>
<li>SOLAR: PV protocol "Deye SUN 30-50k-G03" is using protocol custom input to change between registers 40/41 for old P/Q regulation registers and registers 290/291 for new P/Q regulation registers.</li>
<li>EIC: Added coolant pressure (SPN 109) to delta alarms.</li>
<li>EIC: Seawater pump pressure added to view lines.</li>
<li>EIC: Water in fuel 2 (SPN 6301) added to view lines and M-Logic.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>STORAGE: Modbus registers 2975 and 2986 for ESS protocol “EPC Power” can now be forced to enable via “Set mode to Droop” M-Logic command.</li>
<li>STORAGE: Added missing DC voltage and current readings for ESS protocol Sicon VSG when used without a selected BMS protocol.</li>
<li>STORAGE: Added missing Modbus register timings for ESS protocol “SinExcel PWS2 30K”.</li>
<li>STORAGE: Fixed issue where contactor control was sent too frequently for BMS protocols “CATL EnerOne BMS” and “CATL EnerOne Plus BMS”.</li>
<li>SOLAR/STORAGE: Fixed issue where M-Logic output for “Inh. inverter start” had no effect.</li>
<li>STORAGE: Fixed issue where Q reference ramped instantly to 0 during stop.</li>
<li>SOLAR: Fixed issue where Solis PV read incorrect serial numbers.</li>
<li>SOLAR: Removed division by 2 of P setpoint in FIMER PVS980 inverter. This adjustment was originally made to compensate for an error in the FIMER inverter, which has now been resolved in the latest inverter firmware.</li>
<li>BTB: Fixed issue where active power measurement was incorrectly displayed as reactive power measurement in application supervision.</li>
<li>Display: Multi inputs now show the specifically configured measurement unit instead of defaulting to the unit of multi input 20.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.34.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-34-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1b17421d-9b4d-4be9-9a89-d816e19353b0</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.34.1</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<ul>
<li>USW version required: 3.64.0 PDB rev. 11948</li>
<li>TDU version required: 1.4.5.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>MAINS: Fixed an issue where Mains OK Delay f and U timers were always overruled when only batteries in plant.</li>
<li>GENSET MARINE: Fixed an issue where a PMS CAN failure caused a blackout on the busbar and did not properly keep the controller in SWBD mode.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.35.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-35-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">bfe7c655-90c3-4722-9078-773b6dff7d26</guid>
        <pubDate>2025-10-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.35.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<p>Required versions and compatibility</p>
<ul>
<li>USW version required: 3.64.1 PDB rev. 12031</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New functions</h3>
<ul>
<li>EIC: Added Perkins CPCB IV.</li>
<li>EIC: Added Volvo Penta CPCB IV.</li>
<li>EIC: Added SPN 7831 to CM2358.</li>
<li>STORAGE: Added four M-Logic outputs for plant force discharging, plant force charging, plant freeze discharging, and plant freeze charging in SOC balancing mode.</li>
<li>STORAGE/SOLAR: Added new service view to check which individual power meter communication is active or inactive.</li>
<li>STORAGE: Added four new parameters for setting up droop/VSG deadband regions to be sent to ESS protocols. Added droop deadband registers 1249 and 1250 to be written for SinExcel PWS2 30K ESS protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>STORAGE/SOLAR: Added timer to parameter 7730 "GEN meter err.", parameter 7740 "ESS meter err.", and parameter 7750 "Mains meter err.".</li>
<li>STORAGE/SOLAR: Power meter data for the power meter losing communication is now reset when the corresponding meter error alarm is triggered.</li>
<li>STORAGE: All write registers for SinExcel PWS2 30K have been set to a minimum interval of 5 s, except for 1024, 1025, and 1217 which are set to a 10 ms interval.</li>
<li>STORAGE: Added custom input to SinExcel PWS2 30K for whether Droop/VSG mode is available. Setting droop through M-Logic now writes 1 to register 1236; disabling droop through M-Logic writes 0 to register 1236.</li>
<li>STORAGE: Changed "iE 150 Storage" to "iE 150 Battery".</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>EIC: Engine values in short-cut menu texts now display correctly.</li>
<li>Compact breaker: Breaker off relay now closes only once and remains closed for spring charging.</li>
<li>GENSET: Controllers with S1 configured with DVC 350 no longer experience 'illegal data value' when using the USW.</li>
<li>STORAGE: Megarevo MPS correction – start/stop commands, active power, and reactive power set points now update correctly.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.36.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-36-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">5171a7a8-a3d2-48e7-bde3-6820e01bc9f7</guid>
        <pubDate>2026-01-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.36.0</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<h4>Version 1.36.0 (based on 1.35.0)</h4>
<ul>
<li>USW version required: 3.64.3 PDB rev. 12236</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS Lite compatibility: 5</li>
</ul>
<h3>New features</h3>
<ul>
<li>BATTERY: Added new ESS CAN protocol EODev.</li>
<li>BATTERY: Moved updates to ESS protocol EPC Power from SIPC 0655. Added ESS protocol custom inputs to EPC Power for controlling autoforming and reconnect delay.</li>
<li>GENSET HYBRID/SOLAR/BATTERY: Added M-Logic events for PV/ESS running, starting, stopping, ramping, and derated.</li>
<li>BATTERY: Added M-Logic events for selected SOC balancing mode and “SOC above or equal to plant SOC ...” events.</li>
<li>BATTERY: Added M-Logic events for external genset on busbar.</li>
<li>Added Command Schedulers (previously available in ASC 150 Battery) to the following controller types: GENSET, GENSET HYBRID, GENSET MARINE, ATS, and GENSET PMS lite.</li>
<li>EIC: Added ACU CPCB IV protocol.</li>
<li>SOLAR: Updated Solis and Polycab PV protocols. Added more string power and current measurements. It is now possible to read up to 10 power and current measurements.</li>
<li>Added new predefined multi-input RMI water temperature curve: “CAT sensor-temp”.</li>
<li>Added new predefined multi-input VDC pressure curve: “CAT sensor GP-pressure”.</li>
<li>MAINS: Now supports negative fixed power setpoints for fixed import power when operating in parallel with batteries.</li>
<li>EIC: Added Farizon protocol.</li>
<li>Added new 32-bit Modbus register for reactive power load information at addresses 767 to 768 using function code 04h.</li>
<li>SOLAR: Added new PV protocol “Kehua Logger KM-ACU50”.</li>
<li>BATTERY: Added new ESS protocol EOS energy block v2.</li>
<li>SOLAR: Added new PV protocols: WEG SIW610, WEG SIW400g, and FOXEss R/V.</li>
<li>EIC: Added Wise10 protocol.</li>
<li>SOLAR: Added Sineng SACU Datalogger protocol.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>SOLAR: Changed read addresses for string power and voltage for Solis (Ginlong) and Polycab 50–60 kW.</li>
<li>Mult-input alarm setpoints are now converted upon change of parameter #9158 Engineering units, if the multi-input is of type RMI oil pressure or RMI water temperature.</li>
<li>When changing parameter 9158 "Engineering units", the predefined RMI water temperature, RMI oil pressure, and VDC pressure curves are converted to the configured engineering unit.</li>
<li>When changing parameter 9158 "Engineering units", the configurable curves for RMI water temperature and RMI oil pressure are converted to the configured engineering unit.</li>
<li>GENSET: Multi-inputs configured as mA or V can now be assigned a predefined use. These values are now shown in the supervision view.</li>
<li>BATTERY: AMF for single and PMS now supports plant assist charging. When SOC is below SOC threshold high and energy functionality is OK, the battery will charge according to the mains charging setpoint when the grid is normal and connected.</li>
<li>BATTERY: Parameter 17024 “PS charging limit” has been renamed to “Mains charging limit”, as it is now also supported for MPE and Fixed Power in both single and PMS configurations.</li>
<li>EIC: Added fault code texts for Yanmar x11.</li>
<li>EIC: Added pre-lube logic for Yanmar x11.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Added new parameter 2750 “Frequency recovery” for handling frequency recovery specifically for Volvo Penta engines during 100 % active power load jumps.</li>
<li>GENSET MARINE: Fixed an issue where the busbar was not restored from blackout during CAN failure in AUTO mode.</li>
<li>Fixed an issue where “Service view” was incorrectly shown as the submenu text in the “Ethernet setup” and “PM Ethernet setup” menus.</li>
<li>Fixed an issue where parameter 8930 “Spinning reserve” was unintentionally enabled in a power management setup after power cycling a single unit.</li>
<li>BATTERY: Fixed an issue where batteries in the stopping state did not overlap ground relays with other batteries or gensets.</li>
<li>SDU: During power cycle, the iE 150 now sends a reset after 3 s and also sends a reset when the status alarms disappear.</li>
<li>BATTERY: Fixed an issue where batteries charged from MAINS when MAINS was connected but had MAINS failure.</li>
<li>BATTERY: Fixed an issue where batteries in parallel with gensets charged more from MAINS when using parameter 17024.</li>
<li>SOLAR: Parameter 7960 “DEIF Generic offset” is no longer visible on Solar controllers.</li>
<li>BATTERY: Volvo Penta BMS protocol now reads the correct telegram with PGN 0xFFB0 for DC current and DC voltage.</li>
<li>BATTERY: Fixed an issue where protocol custom inputs were reset after power cycle.</li>
<li>SOLAR: Fallback timer for power limit on parameter 17180 "SunSpec" is now also written to reactive power.</li>
<li>BATTERY: Fixed an issue where ASC150 was sending start to incorrect registers and where starting in PQ mode was not always allowed.</li>
<li>BATTERY: Corrected Sungrow EMS300CP telegrams.</li>
<li>HYBRID: P and Q ramp now acts correctly after back synchronising of MB – both PMS and single controller (bug introduced in version 1.31.0).</li>
<li>The unit for RMI custom multi-inputs is now displayed correctly in the display.</li>
<li>Test mode is no longer cancelled when mode is issued.</li>
<li>PMS lite: Fixed an issue where the AVR regulator used the wrong setpoint for Q loadshare regulation.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iE150 Application SW &#x2013; v1.36.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/ie150-application-sw/1-36-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">35ca5002-5026-4071-9b19-f04d3574ef03</guid>
        <pubDate>2026-03-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iE150 Application SW</category>
        <category domain="version">1.36.1</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 150</category>
          <category domain="product">iE 150 Marine</category>
        <content:encoded><![CDATA[
<h3>Version 1.36.1 (based on 1.36.0)</h3>
<ul>
<li>USW version required: 3.64.3 PDB rev. 12236</li>
<li>TDU version required: 1.4.6.0</li>
<li>PM compatibility: 1.41.0</li>
<li>PMS lite compatibility: 5</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>EIC: Added fuel consumption to the requested PGN list for protocol Cummins PGI.</li>
<li>GENSET HYBRID/SOLAR: Fixed an issue where the controller restarted when Kehua SPI PV protocol was selected.</li>
<li>HYBRID: Fixed a Modbus client issue for hybrid protocols which required a restart of the controller after configuration.</li>
<li>GENSET MARINE: Fixed an issue where multi-start parameters were not taken into account for blackout recovery in AUTO.</li>
<li>PMS lite variants: Fixed an issue where menu 7050 was not available on PMS lite variants.</li>
<li>BTB: Fixed an issue where, if powered up with a breaker position failure, the controller could request gensets to start and close their breakers.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP20 Patch 40) &#x2013; v1.3.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp-sp20-patch-40/1-3-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f4044c8c-d6fc-42fe-8653-f4f66f4040e9</guid>
        <pubDate>2025-03-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP20 Patch 40)</category>
        <category domain="version">1.3.2.0</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h2>[1.3.2.0] - 2025-01-08</h2>
<h3>Added</h3>
<ul>
<li>Added CODESYS runtime v3.5.20.40.</li>
<li>Added info.json with CODESYS build information to PCM21, PCM33 and PCM62.</li>
<li>Increased persistent retain memory to 128 KB for PCM21, PCM33, PCM62 and PCM61.</li>
<li>Added AIM61 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added AIO61 devdesc 1.0.3.0, Revision=16#00000005.</li>
<li>Added AIO62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added DIM61 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.0.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.0.0, Revision=16#00000003.</li>
<li>Added DIM61 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DIO62 devdesc 1.0.1.0, Revision=16#00000002.</li>
<li>Added DOM61 devdesc 1.0.1.0, Revision=16#00000003.</li>
<li>Added AOM62 devdesc 1.0.3.0, Revision=16#00000001.</li>
<li>Added SIM61 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM62 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM63 devdesc 1.0.2.0, Revision=16#00000003.</li>
<li>Added SIM64 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added SIM65 devdesc 1.0.2.0, Revision=16#00000001.</li>
<li>Added Sys Util PCM61 library 1.0.0.0.</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed MIO21 devdesc 1.0.0.1, Revision=16#01000000.</li>
</ul>
<h2>[1.3.1.1] - 2024-10-31</h2>
<h3>Corrections</h3>
<ul>
<li>Changed DDS topic.</li>
</ul>
<h2>[1.3.1.0] - 2024-09-03</h2>
<h3>Added</h3>
<ul>
<li>Added support for PCM2.1 Local I/O.</li>
<li>Enabled support for runtime password policy.</li>
<li>Support for CODESYS Hotkeys.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP20 Patch 40) &#x2013; v1.3.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp-sp20-patch-40/1-3-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a5722715-b7ca-4399-9c1a-405671bb00dc</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP20 Patch 40)</category>
        <category domain="version">1.3.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h4>[1.3.4.0] - 2025-06-03</h4>
<h3>Corrections</h3>
<ul>
<li>Updated startup parameters for EIM3.1 device description version 2.1.0.1 (Revision = 16#02010000)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIM6.2 Software bundle &#x2013; v1.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aim62-software-bundle/1-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8fe89be8-cd8f-4a74-9223-4cb7e967a59a</guid>
        <pubDate>2025-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIM6.2 Software bundle</category>
        <category domain="version">1.0.3.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Added</h3>
<ul>
<li>Support for AIM6·2 (8 x analogue inputs)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIM6.2 Software bundle &#x2013; v1.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aim62-software-bundle/1-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">255e33a4-d288-4734-9177-c13214fd6e1a</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIM6.2 Software bundle</category>
        <category domain="version">1.0.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.0.4.0] - 2025-10-02</h4>
<h3>New features</h3>
<ul>
<li>Added support for -12 to 12 V and 0 to 12 V analogue inputs</li>
<li>Added support for -24 to 24 mA and 0 to 24 mA analogue inputs</li>
<li>Added support for 4 to 20 mA NAMUR NE43 analogue inputs</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Prevent polarity shift when voltages below -10 V are applied to 0 to 10 V analogue inputs</li>
<li>Fixed under-range detection for 4 to 20 mA with a 0.4% margin</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIM6.1 Software bundle &#x2013; v1.0.3.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aim61-software-bundle/1-0-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9f9d7808-3094-436b-83f3-a3e31367e5c6</guid>
        <pubDate>2025-03-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIM6.1 Software bundle</category>
        <category domain="version">1.0.3.0</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Added</h3>
<ul>
<li>Support for AIM6·1 (16 x analogue inputs)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 AIM6.1 Software bundle &#x2013; v1.0.4.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-aim61-software-bundle/1-0-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cbc21a06-b648-462e-b817-44a1e92eb9a2</guid>
        <pubDate>2025-10-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 AIM6.1 Software bundle</category>
        <category domain="version">1.0.4.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.0.4.0] - 2025-10-02</h4>
<h3>New features</h3>
<ul>
<li>Added support for -12 to 12 V and 0 to 12 V analogue inputs</li>
<li>Added support for -24 to 24 mA and 0 to 24 mA analogue inputs</li>
<li>Added support for 4 to 20 mA NAMUR NE43 analogue inputs</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Prevent polarity shift when voltages below -10 V are applied to 0 to 10 V analogue inputs</li>
<li>Fixed under-range detection for 4 to 20 mA with a 0.4% margin</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>MVR FW 250 series &#x2013; v2.5.7.1-245</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/mvr-fw-250-series/2-5-7-1-245/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f4509a83-671d-4279-97b5-022d5b53a948</guid>
        <pubDate>2025-03-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">MVR FW 250 series</category>
        <category domain="version">2.5.7.1-245</category>
          <category domain="release-status">current</category>
          <category domain="product">MVR-F255</category>
          <category domain="product">MVR-G257</category>
          <category domain="product">MVR-M255</category>
          <category domain="product">MVR-M257</category>
          <category domain="product">MVR-T256</category>
          <category domain="product">MVR-T257</category>
        <content:encoded><![CDATA[
<h3>New features&nbsp;</h3>
<ul>
<li>Hardware: Support for T option card (1 x mA output - 4 x mA input).</li>
<li>Function: DIF (Idx&gt;) [87T] and GMAG: Individual setting groups (SGS2).&nbsp;</li>
<li>Generator module: Nominal scaling manual mode.&nbsp;</li>
<li>VRG1 (Vreg) [90]: Parallel Voltage Regulator.</li>
<li>GMAG: Excitation current to mA Out channel selection.&nbsp;</li>
<li>HMI: Alarm view colour selector.&nbsp;</li>
<li>HMI: Arabic language to start screen.&nbsp;</li>
<li>HMI: Chinese font support for objects.&nbsp;</li>
<li>Communication: Ethernet GOOSE storm protection parameter.&nbsp;</li>
<li>Communication: Double Ethernet PRP ports parameter.</li>
<li>Communication: Support for PTP power profiles and VLAN-tagged frames.&nbsp;</li>
<li>Communication: Scaled analogue inputs to IEC 104.&nbsp;</li>
<li>Communication: CTS2 to IEC 61850 mapping.&nbsp;</li>
<li>Communication: URX1 and URX2 [21X] conditions to IEC 61850.&nbsp;</li>
<li>Communication: VHZ1 (2) conditions to IEC 61850.&nbsp;</li>
<li>Communication: Capacitor Protection Module Conditions COL1/2 and CNU1 to legacy protocols.&nbsp;</li>
<li>Communication: U3/U4 frequency to IEC 61850.&nbsp;</li>
<li>Communication: Switch positions added to GOOSE.</li>
<li>Communication: GOOSE analogue values added to HMI and programmable stages.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Pole Slip [78]: Function improvements.</li>
<li>Synchro check [25]: Added LL/DL/LD/DD mode, ability to select line or bus as reference, additional signals.&nbsp;</li>
<li>HMI: Default mimic updated to light theme.&nbsp;</li>
<li>HMI: Several menu item and text adjustments, addition of function ANSI codes.&nbsp;</li>
<li>Fault register: "Fault values register" and "Measurement value recorder" renamed to “Fault register”.</li>
</ul>
<p>&nbsp;</p>
<h3>Corrections</h3>
<ul>
<li>Synchro check [25]: SYN2 and SYN3 force status.&nbsp;</li>
<li>Current transformer supervision: Current transformer supervision functionality was not working if delay was not zero.&nbsp;</li>
<li>Directional overcurrent (Idir&gt;) [67]: Protection blocking set start to zero.&nbsp;</li>
<li>Current unbalance (I2&gt;) [46]: Adjustments to IDMT tripping time calculation.&nbsp;</li>
<li>Voltage regulation (Vreg) [90]: Scaling curve positions were not working.&nbsp;</li>
<li>Frequency measurement: Min/Max tracking frequency allowed limits were not working.&nbsp;</li>
<li>Frequent start FSP (N&gt;) [66]: Frequent start stage was not working correctly.</li>
<li>Logic: &gt;= comparator was also activated on negative values.&nbsp;</li>
<li>Objects: Default user level changed from operator to configurator.&nbsp;</li>
<li>HMI: Push buttons were in undefined state after reboot if set to toggle mode.&nbsp;</li>
<li>HMI: Reset to factory defaults will now reboot HMI and clear mimics and fault registers correctly.&nbsp;</li>
<li>HMI: Custom event description display on event list.&nbsp;</li>
<li>HMI: Vector and trip time characteristics.</li>
<li>HMI: Measurement bar scaling.&nbsp;</li>
<li>Disturbance recorder: Recording failed when device name was more than 28 characters.&nbsp;</li>
<li>Disturbance recorder: Issues saving digital outputs to "REC Digital channels" - selection.&nbsp;</li>
<li>Underexcitation protection (X&lt;) [40]: RX circle radius was renamed from diameter to radius to reflect intended functionality.</li>
<li>Frequency protection f&gt;/&lt; [81O/81U]: fmeas/fset value was always zero.&nbsp;</li>
<li>Harmonics measurement: Harmonic measurement percentage values were "Infinite".&nbsp;</li>
<li>NOC1 (I&gt;) [50/51]: Fault register was not showing fault phases correctly.&nbsp;</li>
<li>Communication/ IEC 61850: Energy measurement demand values not updating.&nbsp;</li>
<li>Communication/ IEC 61850: UCP1 (IUC&gt;) [46C]: UIC Testout event inconsistency.&nbsp;</li>
<li>Communication/ IEC 61850: SOTF: SOF1GGIO1 condition check not updating.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.9.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-9-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">85bfff14-928e-47e7-8fab-5424db20360f</guid>
        <pubDate>2025-05-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.9.0</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Interface Libraries</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">7aa49c05-7a38-4630-a439-307839c81230</guid>
        <pubDate>2025-06-30T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.10.0</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>[2.0.10.0] - 2025-06-11</h4>
<h3>New feature</h3>
<ul>
<li>Enabled deprecated code in libraries</li>
</ul>
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.10.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.11.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-11-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">b0f70b4c-d8a9-470d-9a8e-270ca8bd0573</guid>
        <pubDate>2025-08-11T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.11.1</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>Updates</h3>
<ul>
<li>Updated databases to version 2.0.11.1</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.13.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-13-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">eeae3ccc-8745-4d02-aa17-3f86ed321075</guid>
        <pubDate>2025-10-21T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.13.0</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>Changed</h3>
<ul>
<li>Databases changed to version 2.0.13.0</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.14.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-14-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">4197aaf7-c7cf-4ea9-b726-ed850a0bc14f</guid>
        <pubDate>2025-11-03T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.14.0</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>## [2.0.14.0] - 2025-10-30</h4>
<h3>Changes</h3>
<ul>
<li>Databases updated to version 2.0.14.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.15.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-15-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">50276093-0e8d-4c7d-ab7c-479c8002f938</guid>
        <pubDate>2025-12-29T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.15.0</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h4>## [2.0.15.0] - 2025-12-17</h4>
<h3>&nbsp;Changes&nbsp;&nbsp;</h3>
<ul>
<li>Databases updated to version 2.0.15.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 Flexible application CODESYS libraries &#x2013; v2.0.16.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-flexible-application-codesys-libraries/2-0-16-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">0762297c-79aa-4b90-b60c-e747c96bd7e8</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 Flexible application CODESYS libraries</category>
        <category domain="version">2.0.16.0</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 350</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Databases changed to version 2.0.16.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DIM6.3 software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dim63-software-bundle/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9ac933a7-f450-4bb0-9ed3-3d8938e5eba6</guid>
        <pubDate>2025-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DIM6.3 software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Support for DIM6·3</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 ROM6.1 software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-rom61-software-bundle/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e37ea9bb-6fe9-4be5-bfb6-271a58491c0b</guid>
        <pubDate>2025-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 ROM6.1 software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Support for ROM6·1 (8 x NO relay outputs)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 ROM6.2 software bundle &#x2013; v1.0.2.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-rom62-software-bundle/1-0-2-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3839d3cd-65f1-414e-ba85-8b47ba834a07</guid>
        <pubDate>2025-06-09T17:58:54&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 ROM6.2 software bundle</category>
        <category domain="version">1.0.2.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>New features</h3>
<ul>
<li>Support for ROM6·2 (4 x CO relay outputs)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP21 Patch 10) &#x2013; v1.3.5.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp21-patch-10/1-3-5-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ece7c2da-3fed-4b4d-bc7a-966cb1c43cc3</guid>
        <pubDate>2025-07-07T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP21 Patch 10)</category>
        <category domain="version">1.3.5.1</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.3.5.1] - 2025-06-24</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS runtime v3.5.21.10</li>
</ul>
<h4>[1.3.5.0] - 2025-06-20</h4>
<h3>Changes</h3>
<ul>
<li>Removed support for CODESYS runtime v3.5.20.40 from AMC 300, PCM52, PCM61, PCM21, PCM33 and PCM62</li>
<li>Added CODESYS runtime v3.5.21.0</li>
<li>Added DIM63 devdesc 1.0.2.0, Revision = 16#00000001</li>
<li>Added DOM63 devdesc 1.0.2.0, Revision = 16#00000001</li>
<li>Added ROM61 devdesc 1.0.2.0, Revision = 16#00000001</li>
<li>Added ROM62 devdesc 1.0.2.0, Revision = 16#00000001</li>
</ul>
<h4>[1.3.4.0] - 2025-06-03</h4>
<h3>Changes</h3>
<ul>
<li>Updated EIM31 devdesc 2.1.0.1 startup parameters, Revision = 16#02010000</li>
</ul>
<h4>[1.3.3.0] - 2025-04-04</h4>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS runtimes v3.5.18.40 from PCM21, PCM33 and PCM62</li>
<li>Merged TSP packages for PCM21, PCM33, and PCM62 into one .package file</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1. Added selection of termination for CAN ports</li>
<li>Modbus RTU, removed Pcm51Clib dependency, Modbus RTU is not included in TSPs</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
<h3>New features</h3>
<ul>
<li>TSP packages are now signed</li>
<li>Added IOM33 devdesc 1.0.0.2, Revision = 16#01000003</li>
<li>Added IOM33 devdesc 1.0.0.4, Revision = 16#01000004</li>
<li>Added iEBSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber, and ReadOSVersion</li>
</ul>
<h4>[1.3.2.2] - 2025-01-21</h4>
<h3>Changes</h3>
<ul>
<li>Reversed the Boolean level for negative input on iE250 Local Digital IO</li>
<li>In TSP, use names "Input Positive" and "Input Negative" on iE250 local Digital IO</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP21 Patch 10) &#x2013; v1.3.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp21-patch-10/1-3-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">37a1bffd-c4f4-47f5-afbb-37cfdb71b28b</guid>
        <pubDate>2025-09-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP21 Patch 10)</category>
        <category domain="version">1.3.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.3.6.0] - 2025-08-06</h4>
<h3>Changes</h3>
<ul>
<li>Added DOM6.3 device descriptions 1.0.2.1, Revision = 16#00000002</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed startup parameters IOM3.3 device description 1.0.0.2, Revision = 16#01000003</li>
<li>Fixed startup parameters IOM3.3 device description 1.0.0.4, Revision = 16#01000004</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP21 Patch 10) &#x2013; v1.3.5.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp21-patch-10/1-3-5-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">388e561b-2a1e-421f-be64-93331a686b82</guid>
        <pubDate>2025-07-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP21 Patch 10)</category>
        <category domain="version">1.3.5.1</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.3.5.1] - 2025-06-24</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System v3.5.21.10</li>
</ul>
<h4>[1.3.5.0] - 2025-06-20</h4>
<h3>Changes</h3>
<ul>
<li>Removed support for CODESYS Runtime System v3.5.20.40 from AMC 300, PCM52, PCM61, PCM21, PCM33 and PCM62</li>
<li>Added CODESYS Runtime System v3.5.21.0</li>
<li>Added DIM63 devdesc 1.0.2.0, Revision = 16#00000001</li>
<li>Added DOM63 devdesc 1.0.2.0, Revision = 16#00000001</li>
<li>Added ROM61 devdesc 1.0.2.0, Revision = 16#00000001</li>
<li>Added ROM62 devdesc 1.0.2.0, Revision = 16#00000001</li>
</ul>
<h4>[1.3.4.0] - 2025-06-03</h4>
<h3>Changes</h3>
<ul>
<li>Updated EIM31 devdesc 2.1.0.1 startup parameters, Revision = 16#02010000</li>
</ul>
<h4>[1.3.3.0] - 2025-04-04</h4>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS Runtime System v3.5.18.40 from PCM21, PCM33, and PCM62</li>
<li>Merged TSP packages for PCM21, PCM33, and PCM62 into one .package file</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1. Added selection of termination for CAN ports</li>
<li>Modbus RTU: Removed Pcm51Clib dependency. Modbus RTU is no longer included in TSPs</li>
<li>Removed debug entries from StdLogger.csv</li>
</ul>
<h3>New features</h3>
<ul>
<li>TSP packages are now signed</li>
<li>Added IOM33 devdesc 1.0.0.2, Revision = 16#01000003</li>
<li>Added IOM33 devdesc 1.0.0.4, Revision = 16#01000004</li>
<li>Added iEBSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber, and ReadOSVersion</li>
</ul>
<h4>[1.3.2.2] - 2025-01-21</h4>
<h3>Changes</h3>
<ul>
<li>Reversed the Boolean level for negative input on iE 250 local digital I/O</li>
<li>In TSP, use names “Input Positive” and “Input Negative” on iE 250 local digital I/O</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP21 Patch 10) &#x2013; v1.3.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp21-patch-10/1-3-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">16b62acd-e390-4afb-977d-e00d9a1a92e9</guid>
        <pubDate>2025-09-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP21 Patch 10)</category>
        <category domain="version">1.3.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.3.6.0] - 2025-08-06</h4>
<h3>Changes</h3>
<ul>
<li>Added DOM6.3 device descriptions 1.0.2.1, Revision = 16#00000002</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed startup parameters IOM3.3 device description 1.0.0.2, Revision = 16#01000003</li>
<li>Fixed startup parameters IOM3.3 device description 1.0.0.4, Revision = 16#01000004</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DOM6.3 software bundle &#x2013; v1.0.2.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dom63-software-bundle/1-0-2-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">f63beb11-7f20-44ab-9508-4126512ac6c8</guid>
        <pubDate>2025-08-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DOM6.3 software bundle</category>
        <category domain="version">1.0.2.1</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Added support for new DOM6·3 IO module</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 DOM6.3 software bundle &#x2013; v1.0.2.2</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-dom63-software-bundle/1-0-2-2/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">1379731a-7084-4d62-ba29-07c479cc7b0f</guid>
        <pubDate>2025-09-01T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 DOM6.3 software bundle</category>
        <category domain="version">1.0.2.2</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>[1.0.2.2] - 2025-08-14</h4>
<h3>Changes</h3>
<ul>
<li>Updated the group supply status in ESI XML for DOM6·3 hardware revision B</li>
<li>Updated the DOM6·3 EtherCAT® interface to v3</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>SGC Remote Display RDC 100 &#x2013; vR1.00</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/sgc-rdc-100/r1-00/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">37e79b19-7aa9-4682-8887-88e2d9ceeb42</guid>
        <pubDate>2025-08-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">SGC Remote Display RDC 100</category>
        <category domain="version">R1.00</category>
          <category domain="release-status">current</category>
          <category domain="product">SGC 120 Mk II</category>
          <category domain="product">SGC 420 Mk II</category>
        <content:encoded><![CDATA[
<h3>New feature&nbsp;</h3>
<ul>
<li>Initial version for remote display RDC 100.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS TSP (SP21) &#x2013; v1.3.5.0 (SP21)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-tsp-sp21/1-3-5-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">2a345772-ce58-4f4f-a15f-a22333fd62c8</guid>
        <pubDate>2025-08-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS TSP (SP21)</category>
        <category domain="version">1.3.5.0 (SP21)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>[1.3.5.0] - 2025-06-23</h4>
<h3>Changes</h3>
<ul>
<li>Updated to CODESYS runtime v3.5.21.0</li>
<li>Removed support for CODESYS runtime v3.5.20.40 from AMC 300, PCM52, PCM61, PCM21, PCM33 and PCM62</li>
</ul>
<h3>New features</h3>
<ul>
<li>Added DIM63 devdesc 1.0.2.0, Revision=16#00000001</li>
<li>Added DOM63 devdesc 1.0.2.0, Revision=16#00000001</li>
<li>Added ROM61 devdesc 1.0.2.0, Revision=16#00000001</li>
<li>Added ROM62 devdesc 1.0.2.0, Revision=16#00000001</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS TSP (SP21) &#x2013; v1.3.6.1 (SP21)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-tsp-sp21/1-3-6-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c99f14f7-a39b-4dc3-a624-34245011017b</guid>
        <pubDate>2025-09-18T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS TSP (SP21)</category>
        <category domain="version">1.3.6.1 (SP21)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>[1.3.6.1] - 2025-08-21</h4>
<h3>Changes</h3>
<ul>
<li>Added DOM6·3 devdesc v1.0.2.2, Revision = 16#00000003</li>
</ul>
<h4>[1.3.6.0] - 2025-08-06</h4>
<h3>Changes</h3>
<ul>
<li>PLC devdesc for PCM5·2, PCM6·1, PCM3.1, and AMC 300 now get generated the same way as the devdesc for iE x50</li>
<li>Added DOM6·3 devdesc v1.0.2.1, Revision = 16#00000002</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed startup parameters IOM3.3 devdesc v1.0.0.2, Revision = 16#01000003</li>
<li>Fixed startup parameters IOM3.3 devdesc v1.0.0.4, Revision = 16#01000004</li>
</ul>
<h4>[1.3.5.1] - 2025-06-24</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS runtime to v3.5.21.10</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS TSP (SP21) &#x2013; v1.3.3.0 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-tsp-sp21/1-3-3-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">89227663-12eb-435b-af82-90ecaaf47ad0</guid>
        <pubDate>2025-06-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS TSP (SP21)</category>
        <category domain="version">1.3.3.0 (SP20)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h2>[1.3.3.0] - 2025-04-04</h2>
<h3>New features</h3>
<ul>
<li>TSP packages are now signed</li>
<li>Added IOM3.3 devdesc 1.0.0.2, Revision=16#01000003</li>
<li>Added IOM3.3 devdesc 1.0.0.4, Revision=16#01000004</li>
<li>iE BSP v1.0.0.0, including GetDiskFree, GetPCMSerialNumber and ReadOSVersion</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Increased MaxChannels to 8 for the ChannelServer</li>
<li>Removed support for CODESYS runtimes v3.5.18.40, PCM2.1, PCM3.3 and PCM6.2</li>
<li>Merged TSP packages for PCM2.1, PCM3.3 and PCM6.2 into one .package file</li>
<li>Updated DEIF_SysUtil_PCM61 to v1.0.0.1, added selection of termination for CAN ports</li>
<li>Removed Debug entries from StdLogger.csv</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS TSP (SP21) &#x2013; v1.3.4.0 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-tsp-sp21/1-3-4-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">24eefaad-e860-4cb0-8319-0ea3272dbeac</guid>
        <pubDate>2025-07-02T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS TSP (SP21)</category>
        <category domain="version">1.3.4.0 (SP20)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>&nbsp;[1.3.4.0] - 2025-06-03</h4>
<h3>Corrections</h3>
<ul>
<li>Updated startup parameters for EIM3.1 device description version 2.1.0.1 (Revision = 16#02010000)</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS TSP (SP21) &#x2013; v1.3.7.1 (SP21)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-tsp-sp21/1-3-7-1-sp21/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">fe1263d6-8be1-4545-aa25-343d600abbe0</guid>
        <pubDate>2025-11-04T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS TSP (SP21)</category>
        <category domain="version">1.3.7.1 (SP21)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>## [1.3.7.1] - 2025-10-13</h4>
<h3>Improvements</h3>
<ul>
<li>Upgrade to CODESYS Runtime System version 3.5.21.10.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Added AIO6·1 devdesc v 1.0.4.0, Revision = 16#00000006.</li>
<li>Added AIO6·2 devdesc v 1.0.4.0, Revision = 16#00000002.</li>
<li>Added AIM6·1 devdesc v 1.0.4.0, Revision = 16#00000002.</li>
<li>Added AIM6·2 devdesc v 1.0.4.0, Revision = 16#00000002.</li>
<li>Added AOM6·2 devdesc v 1.0.4.0, Revision = 16#00000002.</li>
</ul>
<h4>## [1.3.7.0] - 2025-09-18</h4>
<h3>Improvements</h3>
<ul>
<li>Upgrade to CODESYS Runtime System version 3.5.21.10.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Added GAM3.2 devdesc v 2.0.1.0, Revision = 16#02000100.</li>
<li>Push analog value to local I/O on every CODESYS iteration.</li>
<li>Rewrote analogue I/O tests to support faster DDS.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>iEx50 CODESYS TSP (SP21) &#x2013; v1.3.8.0 (SP21)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/iex50-codesys-tsp-sp21/1-3-8-0-sp21/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">aa7378e5-45ab-4262-b3c3-da47ed7d3c2c</guid>
        <pubDate>2026-02-13T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">iEx50 CODESYS TSP (SP21)</category>
        <category domain="version">1.3.8.0 (SP21)</category>
          <category domain="release-status">current</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h4>## [1.3.8.0] - 2025-12-03&nbsp;</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System to v3.5.21.40.</li>
<li>Added MIO21 devdesc v1.1.0.0, revision = 16#01010000.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>CODESYS IDE V3.5 SP21 &#x2013; v3.5.21.10 (SP21)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/codesys-ide-v35-sp21/3-5-21-10/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">a08006f7-98cc-4332-89e5-9c7d5ba7077d</guid>
        <pubDate>2025-08-12T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CODESYS IDE V3.5 SP21</category>
        <category domain="version">3.5.21.10 (SP21)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p>Updated to CODESYS IDE V3.5 SP21 Patch 10.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>CODESYS IDE V3.5 SP21 &#x2013; v3.5.15.20 (SP15)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/codesys-ide-v35-sp21/351520/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">ab3cde5d-6f37-40ae-a583-58718766067d</guid>
        <pubDate>2021-02-25T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CODESYS IDE V3.5 SP21</category>
        <category domain="version">3.5.15.20 (SP15)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p><strong>IEC61131-3 PLC programming (ST, FDB, SFC, IL, LD)</strong></p>
<ul>
<li>CODESYS V3 based</li>
<li>Imports old PLC programs (.pro files) written in CODESYS V2</li>
<li>Integrated HMI/Web visualisation</li>
<li>Graphical PLC configuration</li>
<li>Online debugging</li>
<li>Multilanguage programming editor (unicode support) and help in Chinese, German and English</li>
<li>Monitoring of all variables</li>
<li>Writing and forcing of receipts (sets of variables) into the PLC</li>
<li>Debugging your complete project (breakpoints, stepping, single cycle, call stack))</li>
<li>Interrupt-free online changes of POUs and data</li>
<li>Sampling trace</li>
<li>Library management for user-defined libraries</li>
<li>Offline simulation</li>
<li>Graphic PLC configuration</li>
<li>OPC DA Server&nbsp;(required SL license from CODESYS store)</li>
</ul>
<p>&nbsp;</p>
<p>CODESYS V3.5 enables easy programming through all IEC 61131-3-supported languages and the extensions of CODESYS.</p>
<p>The main features of the CODESYS environment are introduced in our User Manual for the specific products eg. AWC 500, AMC 300 and PPU 300 CODESYS, and additional information can be found in the complete technical documentation available online.</p>
<p>Support for DEIF hardware is performed by installing our Target Support Packages, which includes Device Descriptions, EtherCAT Device descriptions and related libraries and tools.</p>
<p><strong>Programming editor and debug&nbsp;</strong><br>The advanced debugging interface gives complete control of all internal variables without the need for any additional tools. It is easy to set up and use the trace function to monitor time series of selected variables in the application.<br><br><strong>I/O configuration&nbsp;</strong><br>DEIFs Hardware modules are supported either as fixed I/O or as EtherCAT I/O.&nbsp; Fixed I/O is configured via the Device Tree. EtherCAT I/O is configured via the Devices under the EtherCAT master. An EtherCAT Scan automatically locates all DEIF Hardware modules available on the EtherCAT bus system.</p>
<p>There after I/O configuration and mapping to memory variables is performed the generic CODESYS way.</p>
<p><strong>Visualisation&nbsp;</strong><br>CODESYS V3 offers an advanced visualisation tool which is supported by every web browser environment. The visualisation tool is integrated in the CODESYS V3 environment and makes it easy to design the visualisation together with the application programming.</p>
<p>The visualisations can then be accessed via browsers featuring support for HTML5/JavaScript.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>CODESYS IDE V3.5 SP21 &#x2013; v3.5.20.40 (SP20)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/codesys-ide-v35-sp21/3-5-20-40/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">191ed361-9e48-4e2a-8b28-b8b218d3d39f</guid>
        <pubDate>2025-01-22T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CODESYS IDE V3.5 SP21</category>
        <category domain="version">3.5.20.40 (SP20)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p>Updated to CODESYS IDE V3.5 SP20 Patch 40.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>CODESYS IDE V3.5 SP21 &#x2013; v3.5.19.60 (SP19)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/codesys-ide-v35-sp21/3-5-19-60/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">8b093718-93e7-4fce-b580-7d147668b9a8</guid>
        <pubDate>2024-06-27T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CODESYS IDE V3.5 SP21</category>
        <category domain="version">3.5.19.60 (SP19)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p><strong>IEC61131-3 PLC programming (ST, FDB, SFC, IL, LD)</strong></p>
<ul>
<li>CODESYS V3 based</li>
<li>Imports old PLC programs (.pro files) written in CODESYS V2</li>
<li>Integrated HMI/Web visualisation</li>
<li>Graphical PLC configuration</li>
<li>Online debugging</li>
<li>Multilanguage programming editor (unicode support) and help in Chinese, German and English</li>
<li>Monitoring of all variables</li>
<li>Writing and forcing of receipts (sets of variables) into the PLC</li>
<li>Debugging your complete project (breakpoints, stepping, single cycle, call stack))</li>
<li>Interrupt-free online changes of POUs and data</li>
<li>Sampling trace</li>
<li>Library management for user-defined libraries</li>
<li>Offline simulation</li>
<li>Graphic PLC configuration</li>
<li>OPC DA Server&nbsp;(required SL license from CODESYS store)</li>
</ul>
<p>&nbsp;</p>
<p>CODESYS V3.5 enables easy programming through all IEC 61131-3-supported languages and the extensions of CODESYS.</p>
<p>The main features of the CODESYS environment are introduced in our User Manual for the specific products eg. AWC 500, AMC 300 and PPU 300 CODESYS, and additional information can be found in the complete technical documentation available online.</p>
<p>Support for DEIF hardware is performed by installing our Target Support Packages, which includes Device Descriptions, EtherCAT Device descriptions and related libraries and tools.</p>
<p><strong>Programming editor and debug&nbsp;</strong><br>The advanced debugging interface gives complete control of all internal variables without the need for any additional tools. It is easy to set up and use the trace function to monitor time series of selected variables in the application.<br><br><strong>I/O configuration&nbsp;</strong><br>DEIFs Hardware modules are supported either as fixed I/O or as EtherCAT I/O.&nbsp; Fixed I/O is configured via the Device Tree. EtherCAT I/O is configured via the Devices under the EtherCAT master. An EtherCAT Scan automatically locates all DEIF Hardware modules available on the EtherCAT bus system.</p>
<p>There after I/O configuration and mapping to memory variables is performed the generic CODESYS way.</p>
<p><strong>Visualisation&nbsp;</strong><br>CODESYS V3 offers an advanced visualisation tool which is supported by every web browser environment. The visualisation tool is integrated in the CODESYS V3 environment and makes it easy to design the visualisation together with the application programming.</p>
<p>The visualisations can then be accessed via browsers featuring support for HTML5/JavaScript.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>CODESYS IDE V3.5 SP21 &#x2013; v3.5.18.40 (SP18)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/codesys-ide-v35-sp21/3-5-18-40/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3188a1e8-29ef-479d-8441-791736a85951</guid>
        <pubDate>2023-06-26T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CODESYS IDE V3.5 SP21</category>
        <category domain="version">3.5.18.40 (SP18)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<p><strong>IEC61131-3 PLC programming (ST, FDB, SFC, IL, LD)</strong></p>
<ul>
<li>CODESYS V3 based</li>
<li>Imports old PLC programs (.pro files) written in CODESYS V2</li>
<li>Integrated HMI/Web visualisation</li>
<li>Graphical PLC configuration</li>
<li>Online debugging</li>
<li>Multilanguage programming editor (unicode support) and help in Chinese, German and English</li>
<li>Monitoring of all variables</li>
<li>Writing and forcing of receipts (sets of variables) into the PLC</li>
<li>Debugging your complete project (breakpoints, stepping, single cycle, call stack))</li>
<li>Interrupt-free online changes of POUs and data</li>
<li>Sampling trace</li>
<li>Library management for user-defined libraries</li>
<li>Offline simulation</li>
<li>Graphic PLC configuration</li>
<li>OPC DA Server&nbsp;(required SL license from CODESYS store)</li>
</ul>
<p>&nbsp;</p>
<p>CODESYS V3.5 enables easy programming through all IEC 61131-3-supported languages and the extensions of CODESYS.</p>
<p>The main features of the CODESYS environment are introduced in our User Manual for the specific products eg. AWC 500, AMC 300 and PPU 300 CODESYS, and additional information can be found in the complete technical documentation available online.</p>
<p>Support for DEIF hardware is performed by installing our Target Support Packages, which includes Device Descriptions, EtherCAT Device descriptions and related libraries and tools.</p>
<p><strong>Programming editor and debug&nbsp;</strong><br>The advanced debugging interface gives complete control of all internal variables without the need for any additional tools. It is easy to set up and use the trace function to monitor time series of selected variables in the application.<br><br><strong>I/O configuration&nbsp;</strong><br>DEIFs Hardware modules are supported either as fixed I/O or as EtherCAT I/O.&nbsp; Fixed I/O is configured via the Device Tree. EtherCAT I/O is configured via the Devices under the EtherCAT master. An EtherCAT Scan automatically locates all DEIF Hardware modules available on the EtherCAT bus system.</p>
<p>There after I/O configuration and mapping to memory variables is performed the generic CODESYS way.</p>
<p><strong>Visualisation&nbsp;</strong><br>CODESYS V3 offers an advanced visualisation tool which is supported by every web browser environment. The visualisation tool is integrated in the CODESYS V3 environment and makes it easy to design the visualisation together with the application programming.</p>
<p>The visualisations can then be accessed via browsers featuring support for HTML5/JavaScript.</p>
        ]]></content:encoded>
      </item>
      <item>
        <title>CODESYS IDE V3.5 SP21 &#x2013; v3.5.22.0 (SP22)</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/codesys-ide-v35-sp21/3-5-22-0-sp22/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f7881be-0456-4ae9-bf1e-7e06031c933d</guid>
        <pubDate>2026-04-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">CODESYS IDE V3.5 SP21</category>
        <category domain="version">3.5.22.0 (SP22)</category>
          <category domain="product">iE 250</category>
          <category domain="product">iE 250 Marine</category>
          <category domain="product">iE 250 PLC</category>
          <category domain="product">iE 350</category>
          <category domain="product">iE 350 Marine</category>
          <category domain="product">iE 350 PLC</category>
          <category domain="product">iE 650 PLC</category>
        <content:encoded><![CDATA[
<h3>Changes</h3>
<ul>
<li>Updated to CODESYS Development System (IDE) V3.5 SP22.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 300 CODESYS TSP (SP21 Patch 10) &#x2013; v1.3.6.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-300-codesys-tsp-sp21-patch-10/1-3-6-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">3f2470d5-410a-4ef8-9bf1-dd28fcbbbd6d</guid>
        <pubDate>2025-08-28T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 300 CODESYS TSP (SP21 Patch 10)</category>
        <category domain="version">1.3.6.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 300</category>
        <content:encoded><![CDATA[
<h4>[1.3.6.0] - 2025-08-06</h4>
<h3>Changes</h3>
<ul>
<li>Added DOM6·3 devdesc v1.0.2.1, Revision = 16#00000002</li>
</ul>
<h3>Corrections</h3>
<ul>
<li>Fixed startup parameters IOM3.3 devdesc v1.0.0.2, Revision = 16#01000003</li>
<li>Fixed startup parameters IOM3.3 devdesc v1.0.0.4, Revision = 16#01000004</li>
</ul>
<h4>[1.3.5.1] - 2025-06-24</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS runtime to v3.5.21.10</li>
</ul>
<h4>[1.3.5.0] - 2025-06-20</h4>
<h3>Changes</h3>
<ul>
<li>Removed support for CODESYS runtime v3.5.20.40 from AMC 300, PCM5·2, PCM6·1, PCM2.1, PCM3.3, and PCM6·2</li>
<li>Added CODESYS runtime v3.5.21.0</li>
<li>Added DIM6·3 devdesc v1.0.2.0, Revision = 16#00000001</li>
<li>Added DOM6·3 devdesc v1.0.2.0, Revision = 16#00000001</li>
<li>Added ROM6·1 devdesc v1.0.2.0, Revision = 16#00000001</li>
<li>Added ROM6·2 devdesc v1.0.2.0, Revision = 16#00000001</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>DVC 350 Application Software &#x2013; v1.0.9</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/dvc-350-application-software/1-0-9/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9ce2a139-9ef0-42a6-8faa-c09edc7048a8</guid>
        <pubDate>2025-10-15T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">DVC 350 Application Software</category>
        <category domain="version">1.0.9</category>
          <category domain="release-status">current</category>
          <category domain="product">DVC 350</category>
        <content:encoded><![CDATA[
<h4>Version 1.0.9 (based on 1.0.8)</h4>
<h3>Corrections</h3>
<ul>
<li>Created an offset on the EEPROM addresses of all parameters to recover products that run out of EEPROM.</li>
<li>Added a parameter to write RAM to EEPROM every X minutes.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 PCM5.2 Linux SDK &#x2013; v3.0.7.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-pcm52-linux-sdk/3-0-7-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">c2d6fa94-916d-40c5-9aab-dda3579b5e0a</guid>
        <pubDate>2025-12-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 PCM5.2 Linux SDK</category>
        <category domain="version">3.0.7.1</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>This release contains minor corrections and changes.</p>
<h3>Corrections</h3>
<ul>
<li>Bug causing link loss on EoE interfaces after EtherCAT rescan.</li>
<li>Fixed module list on the web interface.</li>
<li>Fixed selection of the time zone "(GMT-08:00) Pacific Time (US &amp; Canada)" in the web interface.</li>
<li>Problem with logc tail -f not showing new log lines.</li>
<li>Bug causing logc cat to fail with "too many open files" fail, and consequently also web interface syslog.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated to bingbang v1.0.2.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AWC 500 PCM5.2 OS &#x2013; v3.0.7.1</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/awc-500-pcm52-os/3-0-7-1/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">33e7e445-8fab-46a3-97c2-2d5a3ee92de4</guid>
        <pubDate>2025-12-16T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AWC 500 PCM5.2 OS</category>
        <category domain="version">3.0.7.1</category>
          <category domain="release-status">current</category>
          <category domain="product">AWC 500</category>
        <content:encoded><![CDATA[
<p>This release contains minor corrections and changes.</p>
<h3>Corrections</h3>
<ul>
<li>Bug causing link loss on EoE interfaces after EtherCAT rescan.</li>
<li>Fixed module list on the web interface.</li>
<li>Fixed selection of the time zone "(GMT-08:00) Pacific Time (US &amp; Canada)" in the web interface.</li>
<li>Problem with logc tail -f not showing new log lines.</li>
<li>Bug causing logc cat to fail with "too many open files" fail, and consequently also web interface syslog.</li>
</ul>
<h3>Changes</h3>
<ul>
<li>Updated to bingbang v1.0.2.0.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 MIM6.1 Software bundle &#x2013; v1.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-mim61-software-bundle/1-0-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">13a2f304-393f-44b0-8166-81cd0931310a</guid>
        <pubDate>2026-01-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 MIM6.1 Software bundle</category>
        <category domain="version">1.0.0.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>## [1.0.0.0] - 2025-12-16</h4>
<ul>
<li>&nbsp;Initial release of MIM6.1.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 MIM6.2 Software bundle &#x2013; v1.0.0.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-mim62-software-bundle/1-0-0-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">cff15a15-6511-4734-ad6b-77a692700a31</guid>
        <pubDate>2026-01-09T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 MIM6.2 Software bundle</category>
        <category domain="version">1.0.0.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>## [1.0.0.0] - 2025-12-16</h4>
<ul>
<li>Initial release of MIM6.2.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS TSP (SP22) &#x2013; v1.3.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-tsp-sp22/1-3-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">e679d0cc-37ed-4a09-9683-0f90581dd838</guid>
        <pubDate>2026-04-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS TSP (SP22)</category>
        <category domain="version">1.3.10.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>General release supporting the new CODESYS Runtime System v3.5 SP22</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System to v3.5.22.0.</li>
<li>Updated iEBSP to v2.0.1.0, including GetAvailableDiskStorage, GetAvailableMemory, GetCODESYSVersion, GetCPULoad, GetVariant, and RebootController.</li>
<li>The certificate for signing the TSP package expired. The TSP package is temporarily unsigned, until new signing method is implemented.</li>
</ul>
        ]]></content:encoded>
      </item>
      <item>
        <title>AMC 600 CODESYS run-time (SP22) &#x2013; v1.3.10.0</title>
        <link>https://www.deif.cn/&#x8F6F;&#x4EF6;/amc-600-codesys-run-time-sp22/1-3-10-0/</link>
        <atom:link href="https://www.deif.cn/documentationfeed.xml" rel="self" type="application/rss+xml" />
        <guid isPermaLink="true">9a24661d-25ad-4fe7-aeea-14d6111b0c67</guid>
        <pubDate>2026-04-10T00:00:00&#x2B;00:00</pubDate>
        <category domain="software">AMC 600 CODESYS run-time (SP22)</category>
        <category domain="version">1.3.10.0</category>
          <category domain="release-status">current</category>
          <category domain="product">AMC 600</category>
        <content:encoded><![CDATA[
<h4>New release supporting CODESYS Runtime System v3.5.22.0&nbsp;</h4>
<h3>Changes</h3>
<ul>
<li>Updated CODESYS Runtime System to v3.5.22.0.</li>
<li>Updated iEBSP to v2.0.1.0, including GetAvailableDiskStorage, GetAvailableMemory, GetCODESYSVersion, GetCPULoad, GetVariant, and RebootController.</li>
<li>The certificate for signing the TSP package expired. The TSP package is temporarily unsigned, until new signing method is implemented</li>
</ul>
        ]]></content:encoded>
      </item>

  </channel>
</rss>