Multi-line 2 AGC 150 Application Software

该软件适用于以下 DEIF 产品:

将要下载 1.05.0

自上一版本以来实现的主要变化如下:

PM compatibility: 1.22.0.

New features:

  • Support for the new input configuration interface.
  • DVC 550 PT100 measurements in display and selection in delta alarms.
  • EIC start/stop as a parameter.
  • M-Logic to start DG and close/inhibit close GB in auto mode. M-Logic to inhibit TB close.
  • Scania EMS2 S8 Engine I/F.
  • Configurable spinning reserve request using parameter 8930, not supported in BTB applications.
  • Ground breaker to CORE package
  • Shutdown override as new inhibit.
  • Parameter to use nominal frequency or rpm as reference for EIC speed offset.
  • Support for Volvo Penta EMS2.4.
  • New combined views with electrical data.

Changes:

  • Configurable multi inputs and new DM1 telegrams for JCB LiveLink. 
  • Racked out breaker On/off displayed in log.
  • Minimum level of "Frequency detection level (6165)" changed from 20hz to 10hz. 

Corrections:

  • Ground relay routine improved:
          - There is now always an overlap when transferring ground relays between DGs.
          - The best DG to hold the ground relay now keeps it closed during de-load and transfer of the ground relay happens when the de-loading DG is ready to open its GB.
          - Older versions with ground relay enabled are no longer compatible going forward.
  • AGC 150 Read log freezes controller. 
  • Phase calculations are now properly performed and transmitted to the DVC 550 & D550 when changed through M-Logic.
  • AC configuration in the D550/DVC 550 is now controlled by the AGC.
  • When configured for split phase operation, the nominal voltage setpoint is now correctly calculated for the DVC 550/D550.
  • New parameter #7746 DAVR AC config is introduced. This helps fix situations where the DAVR is not able to follow the AC configuration of the AGC.
  • Configuring a mains standalone application with the CAN bus set to OFF in the application configuration prevented the MB from closing. This has been corrected.
  • If a DG was running with its GB open and ground relay closed, and a mains then connected to the busbar, the ground relay would open. This has been corrected.
  • Alternative engine speed control for Volvo protocols including counter and checksum is added. Can be enabled with the new parameter 15110.
  • LTO now works correctly when unit is STAND-ALONE (non-sync).
  • Multi input alarm level 2 Min/Max now updates correctly when output limits are changed from multi input configuration in USW.

版本 日期 描述

1.05.0

30/11/2020

PM compatibility: 1.22.0.

New features:

  • Support for the new input configuration interface.
  • DVC 550 PT100 measurements in display and selection in delta alarms.
  • EIC start/stop as a parameter.
  • M-Logic to start DG and close/inhibit close GB in auto mode. M-Logic to inhibit TB close.
  • Scania EMS2 S8 Engine I/F.
  • Configurable spinning reserve request using parameter 8930, not supported in BTB applications.
  • Ground breaker to CORE package
  • Shutdown override as new inhibit.
  • Parameter to use nominal frequency or rpm as reference for EIC speed offset.
  • Support for Volvo Penta EMS2.4.
  • New combined views with electrical data.

Changes:

  • Configurable multi inputs and new DM1 telegrams for JCB LiveLink. 
  • Racked out breaker On/off displayed in log.
  • Minimum level of "Frequency detection level (6165)" changed from 20hz to 10hz. 

Corrections:

  • Ground relay routine improved:
          - There is now always an overlap when transferring ground relays between DGs.
          - The best DG to hold the ground relay now keeps it closed during de-load and transfer of the ground relay happens when the de-loading DG is ready to open its GB.
          - Older versions with ground relay enabled are no longer compatible going forward.
  • AGC 150 Read log freezes controller. 
  • Phase calculations are now properly performed and transmitted to the DVC 550 & D550 when changed through M-Logic.
  • AC configuration in the D550/DVC 550 is now controlled by the AGC.
  • When configured for split phase operation, the nominal voltage setpoint is now correctly calculated for the DVC 550/D550.
  • New parameter #7746 DAVR AC config is introduced. This helps fix situations where the DAVR is not able to follow the AC configuration of the AGC.
  • Configuring a mains standalone application with the CAN bus set to OFF in the application configuration prevented the MB from closing. This has been corrected.
  • If a DG was running with its GB open and ground relay closed, and a mains then connected to the busbar, the ground relay would open. This has been corrected.
  • Alternative engine speed control for Volvo protocols including counter and checksum is added. Can be enabled with the new parameter 15110.
  • LTO now works correctly when unit is STAND-ALONE (non-sync).
  • Multi input alarm level 2 Min/Max now updates correctly when output limits are changed from multi input configuration in USW.

1.04.2

22/09/2020

PM compatibility: 1.17.2.

Corrections:

  •    TEST type in StandAlone (option S1) is limited to SIMPLE TEST.
  •    Limit evaluation of multi-input 23 alarm for use in M-Logic is now working.
  •    Included CAN Start/Stop in the Hatz proprietary CM1 telegram.
  •    Current handling of TIER 4 icons for the Hatz protocol.
  •    Read Aftertreatment 1 Intake Gas telegram for the Hatz protocol.
  •    Necessary to force a regeneration until current feedback is received from ECU.
  •    Fuel optimization + running hours does not swap DG's at fixed load.

1.04.1

29/07/2020

Version 1.04.1 based on 1.04.0

PM compatibility: 1.17.2

Corrections:

  • Errors regarding powermanagement applications with PV, ASC and battery controller corrected.
 

1.04.0

29/06/2020

Version 1.04.0 based on 1.03.1

PM compatibility: 1.17.2

New features:

  • Controller type 'Hybrid DG unit' added with support of PV inverter and weather protocols.
             • Minimum genset load in island
             • Modbus master support
             • Communication RS485 menu/setup updated with Modbus Master
             • Load calculation in terms of solar power
             • POA and BOM for calculating P max
             • PV energy counters
             • PV breaker feedback
             • Monitoring of inverter
             • Inverter start/stop logic
             • Start/Stop logic for DG in MPE with PV 
             • PV semi start/stop from display

  • Support of the new input configuration interface introduced.
  • Added support for MAN engine protocol.
  • Added support for Hatz engine protocol.
  • Added support for Yuchai engine protocol.
  • Added support for Weichai engine protocol.

Corrections:

  • Unwanted appeareance of 30min data storage alarm on MAINS eliminated.
  • Error regarding CIO module communication after communication errors corrected.
 

1.03.1

14/05/2020

PM compatibility: 1.17.2.

Corrections:

  • Analog output limits for the transducer output are corrected.
  • Transducer input range is extended on multi inputs to support the setup of limits corrected in #1.
  • STOP button has always a lid on the genset when running German rule, V0108.

1.03.0

03/04/2020

PM compatibility: 1.17.2

New features:

  •    DVC 550 and D550 are now supported by the AGC.
  •    Configurable amount of units for triggering Fatal CAN Error alarm, added in menu 8800.

Changes:

  •    Emulated value for I>> alarms added.
  •    Easy Connect is no longer blocking DG start in single DG applications.

Corrections:

  •    In AMF situations where the mains had no TB, and #7065 mains fail ctrl was set to "Start engine" and the DGs had to connect through a BTB to supply the mains, the MB would not open as it did not have information about whether or not the DGs Hz/V OK timer had run out. And as the MB would not open the BTB would not close resulting in a deadlock. This has been corrected.
  •    TB power capacity overrule timer will now run if there is an active MB trip failclass or the MB cannot be closed.
  •    Ring bus applications: If BTBs were closed at and under application configuration, opening a BTB could cause a DG to start without a proper start signal.
  •    Fixed a situation where opening a semi BTB, in a plant with an active start signal, would cause a DG to briefly engange its start prepare relay.
  •    In a plant where all DGs are divided by open BTBs, if for example, DG1 is running and needs help from DG2, DG2 would start and close its breaker, then synchronize the BTB, and as the BTB would close, DG3 would briefly engange its start prepare relay. This has been fixed.
  •    PMS + ISLAND + SEMI + GUIDED MIMIC: Start/stop buttons LED visible when relevant on genset.

1.02.0

26/03/2020

PM compatibility: 1.17.0.

New features:

  •    Two new EIC aftertreatment alarms have been added: "High SOOT warning" and "High SOOT shutdown".

Changes:

  •    Vector jump, df/dt, positive busbar sequence and directional over-current are now available in CORE MAINS and CORE BTB.
  •    New TIER 4 icons for JCB EIC are added.

Corrections:

  •    Parameter handling could in special cases cause decimals to be handled incorrectly in the display menu. This is corrected.
  •    Problems with freeze and white screen are now prevented.
  •    Analogue values from CIO 308 are now shown correctly in view-lines.
  •    JUMP menu causing unwanted parameter change is corrected.
  •    JUMP menu freeze is now prevented.
  •    Overspeed 2 menu (4520) is now shown correctly.
  •    GUIDED mimic is corrected with external breaker, so GB ON/OFF buttons do not lit up.

1.01.0

19/12/2019

PM compatibility: 1.17.0.

New features:

  • EIC: JCB J1939 protocol is added.
  • EIC: DEF level shown on lower tiny line in measure views. 
  • Stand Alone (option S1) is implemented. Breaker selection is extended with 'No breaker' and 'External breaker'.
  • LED colors can now be changed. An option to select a different LED color behavior in parameter 6084.
  • Now it is possible to change the source address for PGN GC1 and CM1 independently of each other for all engine protocols.

Corrections:

  • BTB can now be part of a plant with CORE units.

1.00.3

22/10/2019

PM compatibility: 1.17.0

Corrections:

  • External BTB position feedbacks are now working again.
  • Phase sequence error alarms are now working 3W3 coupling.
  • Service timers can now be reset.
  • Translated texts for I/O texts in Service View are now shown correctly.

1.00.2

05/08/2019

Version 1.00.2 based on 1.00.1

PM compatibility: 1.17.0

Corrections:

  •    Deloading the TB is now properly handled in test mode when parameter #8273 "Deload TB back sync." is enabled
  •    Multi inputs could go into overflow when set to voltage type
  •    Internal analog outputs (52/55) now works correct when used with GP PID.
  •    Genset priority would update even though the user had not issued an update.
  •    If mains ATS is active, and TB is closed onto a healthy busbar, and the controller is powercycled, the TB no longer opens and closes on power up.
  •    When sending a stop command during idle start the idle relay is kept closed.
  •    Fixed situations where multi start would not work correctly in ISLAND and AMF applications.
  •    M-Logic flag "Run all available island DG's" starts all DG's when activated.
  •    Mimic for BTB and MAINS with External breaker updated, so the respective buttons (open/close) are not visible.
  •    Various parameters added to parameter tree
  •    Improved Easy Connect functionality:
          - Rapid menu changes prevented
          - Info text on removed units
          - Possibility to remove the other unit with pop-up when only 2 in plant
          - Better handling of fault situations (Appl. hazard or Duplicate CAN ID)
          - Removed units are no longer blocked from running
          - Faster indication of changes on the other units

1.00.0

30/04/2019

PM compatibility: 1.17.0

  • Initial release